Loading...
HomeMy WebLinkAbout060 Roof Lighting Plan - NorthOS11 11 1 1 3 3 A A 10 10 6 6 12 12 13 13 7 7 8 8 C C 2 2 5 5 9 9 B B 4 4 D D E E W2 H1-9C1C1 C1C1 C1 C1 H2-9 ACE JOB 23HL5778 3060 CABERNET DR. SUITE 3 HELENA, MT 59601 406-204-2400 N S SHEET NO.: TITLE: COPYRIGHT 2023 SMA, P.C. REVISIONS: KEYMAP: ARCHITECT/ENGINEER SEAL: PROJECT: PROJECT LOCATION: PREPARED FOR: OWNER LOGO: CONSULTANT LOGO/CONTACT: PROJECT NUMBER: DRAWN BY: CHECKED BY: TEAM: PHASE: DATE: SMA PROJECT NUMBER:Plot Date:NOT FOR CONSTRUCTION AHJ APPROVAL: HELENA P: 406-442-4933 BOZEMAN P: 406-219-2216 www.sma.design 11/21/2023 2:24:18 PME3.60 22-099 2023-11-21 ROOF LIGHTING PLAN - NORTH NP DV 811 WEST MENDENHALL APARTMENTS 22-099 811 West Mendenhall Street Bozeman, MT 59175 Arel Capital / Boundary Development SPR FIRST CYCLE RESPONSES ELECTRICAL LIGHTING GENERAL NOTES A REFER TO ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION ON DEVICE LOCATIONS, DIMENSIONS, ETC. CAREFULLY EXAMINE ARCHITECTURAL FLOOR PLANS, CEILING PLANS, ELEVATIONS, ETC. FOR INFORMATION THAT AFFECTS ELECTRICAL WORK. NOTIFY ARCHITECT/ENGINEER IMMEDIATELY OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL AND ELECTRICAL PLANS. B ALL DARK ITEMS ARE NEW, UNLESS NOTED OTHERWISE. ALL SHADED ITEMS ARE EXISTING TO REMAIN. C ALL ITEMS DENOTED WITH AN (R) ARE RELOCATED OR REINSTALLED. ALL ITEMS DENOTED WITH AN (E) ARE EXISTING TO REMAIN. D MODIFY AND REUSE EXISTING CIRCUITS WHERE POSSIBLE. CIRCUITING SHALL BE AS SHOWN BUT CIRCUIT NUMBERS MAY BE CHANGED TO MAKE USE OF EXISTING AVAILABLE CIRCUITS. PROVIDE NEW BREAKERS AND WIRING AS NEED TO ACCOMMODATE NEW CIRCUITING. E CONNECT ALL LIGHTING FIXTURES TO EXISTING LIGHTING CIRCUITS UNLESS NOTED OTHERWISE. VERIFY EXISTING LOAD PRIOR TO CONNECTING ADDITIONAL LIGHTING FIXTURES. F CONNECT ALL EXIT SIGNS AND EMERGENCY FIXTURES TO EXISTING EMERGENCY CIRCUITS SUPPLYING AREA UNLESS NOTED OTHERWISE, WIRING NOT SHOWN. G LOW VOLTAGE WIRING FOR OCCUPANCY SENSORS AND POWER PACKS NOT SHOWN. PROVIDE POWER PACKS AND WIRING AS REQUIRED FOR ALL OCCUPANCY SENSORS. H VERIFY VOLTAGE OF EXISTING LIGHTING CIRCUITS PRIOR TO SUBMITTALS. COORDINATE ANY MODIFICATIONS TO LIGHTING CIRCUITS OR FIXTURES WITH ENGINEER. I PROVIDE UNSWITCHED HOT CONDUCTOR FROM LOCAL LIGHTING CIRCUIT TO ALL EMERGENCY AND EXIT FIXTURES. J WHEN LIGHT SWITCHES ARE SHOWN LOCATED ON THE WALL THAT IS COMMON WITH THE END OF THE DOOR SWING INTO A SPACE, DO NOT LOCATE THE SWITCHES BEHIND THE DOOR BUT RATHER A MINIMUM OF 6” FROM THE END OF THE SWING. VERIFY EXACT DOOR SWING PRIOR TO ROUGH-IN. K FIRE SEAL ALL PENETRATIONS IN FIRE RATED WALLS. COORDINATE WITH ARCHITECTURAL FOR LOCATIONS. ELECTRICAL KEYNOTES NO.DATE REVISION DESCRIPTION N 1/8" = 1'-0"E3.60 1 ROOF LIGHTING PLAN - NORTH SITE PLAN REVIEW