Loading...
HomeMy WebLinkAbout033 A301 Building B - Building SectionsONE-HALF-HOUR CORRIDOR (FIRE PARTITION) ONE-HOUR-FIRE-RESISTANT CONSTRUCTION (TYPE V-B) ONE-HALF-HOUR DWELLING SEPARATION (FIRE PARTITION) ONE-HOUR-FIRE-RESISTANT CONSTRUCTION (TYPE V-B) SEPARATION LEGEND 100'-0" LEVEL 1 FLOOR 111'-2 3/4" LEVEL 2 FLOOR 132'-5 3/4" TOP OF ROOF 96'-0" T.O. FOOTING A 121'-2 7/8" TRUSS BEARING D2 A301 A351 D1 C A352 D4 MASTER BEDROOM 1 B BEDROOM 1CLOSETMASTER BEDROOM 2 A351 D3 MASTER BEDROOM 1BEDROOM 1 CLOSETMASTER BEDROOM 2MASTER BEDROOM MASTER BEDROOM CLOSET CLOSET BEDROOM BEDROOM 03.0103.01 03.05 03.05 09.05 09.05 09.06 09.06 09.06 09.06 100'-0" LEVEL 1 FLOOR 111'-2 3/4" LEVEL 2 FLOOR 132'-5 3/4" TOP OF ROOF 96'-0" T.O. FOOTING 1 121'-2 7/8" TRUSS BEARING B2 A301 B1 A302 A351 D2 423 A352 D3 MASTER BEDROOM MASTER BATH CLOSETKITCHENMASTER BEDROOM MASTER BATHCLOSET KITCHEN MASTER BEDROOM MASTER BATHCLOSET KITCHEN MASTER BEDROOM MASTER BATH CLOSETKITCHEN 03.01 03.01 06.03 03.0503.05 09.05 09.05 04.26 03.01 03.01 09.06 09.06 09.06 09.06 04.26 04.24 04.24 GENERAL NOTES A. GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS, DIMENSIONS, AND ASSEMBLIES PRIOR TO CONSTRUCTION. REPORT ANY SIGNIFICANT DISCREPANCIES TO THE ARCHITECT. B. AN AUTOMATIC FIRE SPRINKLER SYSTEM IS TO BE INSTALLED THROUGHOUT THE ENTIRE BUILDING PER NFPA 13R. C. CONCRETE FOUNDATION WALLS RETAINING EARTH TO RECEIVE TWO COATS OF BITUMINOUS DAMP PROOFING MATERIAL. D. MINIMUM ROOF CLASSIFICATION TO BE CLASS 'C'. E. MINIMUM ROOF SLOPE TO BE 1/4" PER FOOT. F. INSULATE ENTIRE FLAT ROOF AREAS WITH R-49 POLYISOCYANURATE ABOVE ROOF DECKING. G. EXPOSED FOUNDATION WALLS TO RECEIVE RUBBED FINISH. H. SEE ENGINEERING SHEETS FOR ADDITIONAL INFORMATION. I. MASONRY TO HAVE CONTROL JOINTS AT 30'-0" O.C. MAXIMUM. J. NOT ALL INTERIOR ELEMENTS ARE NOTED FOR CLARITY. SEE WALL SECTIONS, DETAILS, AND WALL TYPES FOR ADDITIONAL INFORMATION. 233 SOUTH PLEASANT GROVE BLVD. SUITE #105 PLEASANT GROVE, UTAH 84062 PHONE: (801) 769-3000 core@corearch.com NOT FOR CONSTRUCTION THE INFORMATION HEREIN IS THE PROPERTY OF CORE ARCHITECTURE AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2023 CORE ARCHITECTURE, LLC PROFESSIONAL STAMP SHEET NUMBER SHEET TITLE A 1 REVISIONS DATE: PROJECT #: PM / PA: PIC: PROJECT INFORMATION DESCRIPTION DATE THIS DRAWING SET IS INTENDED TO BE PRINTED IN COLOR CONSULTANT INFORMATION DRAWING SET STATUS B C D 2 3 4 5 6 PROJECT TITLE AND ADDRESS9/1/2023 11:32:09 AMAutodesk Docs://23-029 Bozeman Multifamily/23-029 Bozeman Multifamily Building B.rvtBUILDING SECTIONS A301 28 JULY 2023 23-029 MRR MMA PERMIT REVIEW & BID DOCUMENTSTHE BOÖTES -BUILDING BOPPORTUNITY WAY AND SOUTH11TH AVEBOZEMAN, MONTANA 59718KEYNOTES 03.01 CONCRETE FOUNDATION WALL. SEE STRUCTURAL. 03.05 CONCRETE SLAB OVER 4" OVER 10 MIL VAPOR RETARDER OVER FREE DRAINING GRAVEL. SEE STRUCTURAL FOR SLAB THICKNESS AND REINFORCING. 04.24 STRUCTURAL WOOD ROOF TRUSS. 04.26 ATTIC TO BE INSULATED THROUGHOUT WITH R-38 BLOWN-IN INSULATION. PROVIDE BAFFLES AT EAVE LINE AS REQUIRED. 06.03 SINGLE-PLY ROOF MEMBRANE OVER ROOF 1" POLYISOCYANURATE OVER ONE LAYER ATLAS FR-10 SLIP SHEET OVER STRUCTURAL WOOD SHEATHING. MINIMUM ROOF CLASSIFICATION TO BE AS NOTED ON THE CODE ANALYSIS. INSTALL PER MANUFACTURER'S REQUIREMENTS FOR MECHANICALLY FASTENED SYSTEM. FULLY ADHERE TO VERTICAL SURFACES AND CONTINUOUS BENEATH METAL PARAPET CAP AND DOWN FRONT SIDE 1" MIN. SINGLE-PLY TPO ROOFING. WHITE, 60 MIL. 15 YEAR WARRANTY MATERIALS. 09.05 1" GYPCRETE OVER SHEATHING GLUED AND NAILED OVER FLOOR JOIST. SEE FRAMING PLANS FOR SIZE AND SPACING. 09.06 WOOD BEAM OR HEADER. SEE FRAMING PLANS. SCALE:3/16" = 1'-0"A301 BUILDING SECTION 1B2 SCALE:3/16" = 1'-0"A301 BUILDING SECTION 2D2