Loading...
HomeMy WebLinkAbout022 A102 Building A - Floor Plan - Level 2D D 1 1 7'-0"7'-0" B2 A302 D2 A301 D2 A301 D4 A352 B B 4 4 2 2 3 3 74'-4" 5 15/16"79'-3"37'-1"5'-1"37'-1"1'-6"1'-10"1'-8"11'-11 3/8"9'-1 5/8"11'-0"5 15/16"5 15/16"11'-2"9'-1"11'-10"1'-8"1'-10"1'-6"12'-11 15/16"6'-4"3'-2"12'-8"3'-2"6'-4"12'-6"5 15/16" 68'-4"1'-6"1'-10"1'-8"11'-10"9'-1"11'-2"5 15/16"79'-3"37'-1"5'-1"37'-1"5 15/16"12'-3"8'-2"11'-8"1'-8"1'-10"1'-6"2'-0 15/16"1'-0"13'-9"14'-2 7/8"14'-2 11/16"14'-4 7/16"1'-0"1'-0"B2 A301 4'-0 1/2" 4'-0 1/2" BA BB B A D C AD2 C C AD2 C D A B B B B A D C C AD2 C AD2 C A AD1 AD1AD1 AD1 A A C C D1 A352 D3 A352 A201 3-1263 TYPE B A204 2-1000 TYPE B CLOSETCLOSETCLOSETMASTER BEDROOM 2 BEDROOM 1 MASTER BEDROOM 1 LIVING KITCHENKITCHENPANTRYPANTRY MECHMASTER BATH 2 CLOSETCLOSET MASTER BATH BATHROOM LAUNDRY MASTER BATH 1 CLOSET MASTER BEDROOM BEDROOM LAUNDRY BATHROOM MECH KITCHEN KITCHEN LIVING BEDROOM MASTER BEDROOM MECH MASTER BATH CLOSET BATHROOM LAUNDRY CLOSET MASTER BATHMECH MASTER BEDROOMBEDROOM LAUNDRY BATHROOM LIVING LIVINGA203 2-1000 TYPE B A202 2-1000 TYPE B AD6AD6 AD6 AD6 AD3 AD5 AD5 AD4 AD3 AD5 AD5 AD3 AD4 AD5 AD3AD3 AD5AD4 AD7AD7 PANTRYPANTRY AD7AD7 AD4 AD5 AD3 AD5 AD4 AD5 AD5 AD4 AD3 AD5 AD3 AD4 AD5CLOSETAD4 AD4 AD3 A451 B1A451 B4 5'-9 3/4" 3'-8 1/4" 3'-0" 6" 2'-5" 3'-5"1'-7"1'-7"1'-6" 2'-0" 3'-0" 2'-8" 2'-3 3/16" 1'-2 13/16" 1'-7" 1'-2 5/8" 4 3/8" 3'-8" 2'-5 7/8" 3'-3 1/8" 7'-9" 10" 3'-0" 2 3/4" 3'-6 1/4" 6 1/2" 5'-2 1/2" 6'-0"62'-7"5'-9" 6'-9"18'-0"3'-2"12'-8"3'-2"6'-4"12'-6"5'-3 1/2"3 1/2"5'-7"3'-4"2'-8"2'-8 3/4"4 1/4"2'-6"3'-5"3'-5"2'-6"2'-0"3'-5"3'-5"3'-1 3/8"5'-10" 3'-8 1/16" 3'-0" 6 1/4" 2'-4 3/4" 3'-5"1'-7"1'-7" 1'-6 1/4" 1'-11 3/4" 3'-0" 2'-8" 3'-6" 1'-7"1'-7" 3'-8" 2'-5" 3" 3'-0" 3'-11 1/4" 6'-0 11/16"2'-6"3'-5"3'-5"2'-6"1 3/8"3'-0"2'-4 3/4"3'-6 7/8"5'-8"5'-6"2'-5" 3'-5" 3'-5" 2'-5" 1'-5" 2'-7" 2'-9 3/4"1'-4 1/4"1'-0 1/2"3'-2 1/2" 8'-0"3'-0"2'-4 3/4"3'-8 7/8"7'-5"3'-7"N Q Q N N N N N Q Q M N N N N M Q NN Q N N NN N N N Q Q N N N N M N N N N M Q N Q P N N N N N QQQ N N Q N B C C A D D C A C B B C CD F G E HH H HH E G F D D A B B H H H H H D E G FD D A B B BCCD A DD A C Q CB B B A D D F G E D D N N N NN N N N Q Q N N N N N N N N N QQ N N N N Q Q N N N M N N N N N Q Q N N N N N Q N Q Q N6'-0 3/4" 4'-4 3/4" 4'-11 15/16" 6'-3 13/16" 4'-0 3/4" 4'-1 3/8" 5'-11 3/8" 4 3/4" 2'-8"2'-4 3/4"5'-4 3/4"6"3'-1 1/8"2'-6 13/16" 4 3/4" 6'-0" 4'-0 3/4" 4'-4 3/4" 6'-4 3/4" 2'-6" 1'-9 1/8"6"2'-0 5/16"3'-4 7/16" 4'-4 3/4" 4'-9 3/4" 2'-5 9/16" 2'-6 5/8" 6'-3 13/16" 4'-0 3/4" 4'-0 3/4" 6'-0" 4 3/4" 2'-7 3/4"6'-9 3/4" 2'-4 3/4" 5'-4 3/4"8"2'-11 1/8"Q AD5 01.0201.02 D K D 1'-2 1/2"1'-8"D K D 1'-2 1/2" 1'-8" 02.03 04.22 02.03 04.22 04.223'-5"3'-5"D1 A353 01.0106.07 02.06 02.06 02.0602.06 06.01 PATIO PATIO PATIO PATIO CORRIDOR D D D DD 03.13 03.13 03.13 03.13 06.02 ONE-HALF-HOUR CORRIDOR (FIRE PARTITION) ONE-HOUR-FIRE-RESISTANT CONSTRUCTION (TYPE V-B) ONE-HALF-HOUR DWELLING SEPARATION (FIRE PARTITION) ONE-HOUR-FIRE-RESISTANT CONSTRUCTION (TYPE V-B) SEPARATION LEGEND A. GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR CONSTRUCTION. REPORT ANY SIGNIFICANT DISCREPANCIES TO THE ARCHITECT. B. COORDINATE INSTALLATIONS OF ALL "AFTER CONTRACT" ASSEMBLIES WITH OWNER PRIOR TO CONSTRUCTION OF ADJOINING OR RELATED STRUCTURES. C. PROVIDE 18" MINIMUM CLEAR FLOOR SPACE AT PULL SIDE OF ALL DOORS. PROVIDE 12" MINIMUM CLEAR FLOOR SPACE AT PUSH SIDE OF ALL DOORS. D. UNLESS OTHERWISE NOTED OR DIMENSIONED, LOCATE DOORS AS FOLLOWS: • MASONRY WALLS- OUTSIDE OF FRAME 8" FROM FACE OF WALL (ON BLOCK MODULE), • FRAMED WALLS-INSIDE OF JAMB 4" FROM FINISHED WALL (ADJUST FOR TILE WHERE SHOWN). E. CONCRETE FOUNDATION WALLS RETAINING EARTH TO RECEIVE TWO COATS OF BITUMINOUS DAMP PROOFING MATERIAL. F. AN AUTOMATIC FIRE SPRINKLER SYSTEM IS TO BE INSTALLED THROUGHOUT THE ENTIRE BUILDING PER NFPA 13R. G. SEE STRUCTURAL, MECHANICAL, AND ELECTRICAL SHEETS FOR ADDITIONAL INFORMATION H. SEE INTERIOR ELEVATIONS ON AI201 AND MILLWORK DETAILS ON AI551 FOR FINISHES OF MILLWORK BASES, AND COUNTERTOPS SEE SHEETS A151, A152 FOR REFLECTED CEILING PLAN INFORMATION. I. SEE SHEETS AI101, AI102, FOR FINISH INFORMATION. CONFIRM FINISHES WITH OWNER PRIOR TO ORDERING. J. SEE A601, A602, AND A603 FOR DOOR AND WINDOW INFORMATION. K. GENERAL CONTRACTOR SHALL REVIEW AND APPROVE ALL APPLIANCES WITH OWNER PRIOR TO PURCHASING EQUIPMENT AND FABRICATING MILLWORK. L. SEE THE SPECIFICATION FOR ADDITIONAL INFORMATION. M. SEE G000 FOR LEGENDS, SYMBOLS, ABBREVIATIONS AND OTHER ARCHITECTURAL GENERAL INFORMATION. N. SEE G003 FOR WALL TYPES. O. PROVIDE BACKING/BLOCKING FOR WALL MOUNTED ITEMS-INCLUDING GRAB BARS, HANDRAILS, SIGNAGE AND EQUIPMENT AS REQUIRED. P. TILE IS TO BE SET OVER CEMENTITIOUS BACKER BOARD UNDERLAYMENT. RECESS SLAB AS/IF REQUIRED. VERIFY WITH OWNER. Q. DO NOT SCALE DRAWINGS. GENERAL NOTES SCALE: 3/16" = 1'-0"A102 FLOOR PLAN - LEVEL 2D2 233 SOUTH PLEASANT GROVE BLVD. SUITE #105 PLEASANT GROVE, UTAH 84062 PHONE: (801) 769-3000 core@corearch.com NOT FOR CONSTRUCTION THE INFORMATION HEREIN IS THE PROPERTY OF CORE ARCHITECTURE AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2023 CORE ARCHITECTURE, LLC PROFESSIONAL STAMP SHEET NUMBER SHEET TITLE A 1 REVISIONS DATE: PROJECT #: PM / PA: PIC: PROJECT INFORMATION DESCRIPTION DATE THIS DRAWING SET IS INTENDED TO BE PRINTED IN COLOR CONSULTANT INFORMATION DRAWING SET STATUS B C D 2 3 4 5 6 PROJECT TITLE AND ADDRESS8/3/2023 12:22:57 PMAutodesk Docs://23-029 Bozeman Multifamily/23-029 Bozeman Multifamily Building A.rvtFLOOR PLAN - LEVEL 2 A102 28 JULY 2023 23-029 MRR MMA PERMIT REVIEW & BID DOCUMENTSBOÖTES - BUILDING AOPPORTUNITY WAY AND SOUTH11TH AVEBOZEMAN, MONTANA 59718KEYNOTES 01.01 ADA COMPLIANT SEMI RECESSED FIRE EXTINGUISHER CABINET WITH 2A10BC FIRE EXTINGUISHER INSIDE. SEE DETAIL D1/A701. 01.02 ADA COMPLIANT "STAIRWAY" SIGN. SEE SHEET G002. 02.03 42" GUARDRAIL WITH ACCESS GATE. SEE DETAILS ON SHEET A456. 02.06 42" HIGH GUARDRAIL. SEE DETAILS ON SHEET A504. 03.13 STRUCTURAL COLUMN. SEE STRUCTURAL. 04.22 PREFINISHED METAL HANDRAIL 36" ABOVE FINISHED FLOOR OR NOSE OF STAIRS. SEE TYPICAL APT DETAILS ON SHEET A452. 06.01 PRIMARY AND SECONDARY ROOF DRAINS. MOUNT ROOF DRAINS 2'-0" MINIMUM FROM CLOSEST VERTICAL SURFACE. TIE PRIMARY ROOF DRAINS TO STORM DRAIN SYSTEM. PROVIDE PIPING FOR SECONDARY DRAINS TO BRASS SCUPPERS AT EXTERIOR WALLS AS SHOWN. MOUNT BRASS SCUPPERS 6" ABOVE TRUSS BEARING. SEE DETAILS ON A701. 06.02 PRE-FINISHED METAL PARAPET CAP. COORDINATE COLOR WITH EXTERIOR ELEVATIONS AND FINISH MATERIALS. 06.07 ROOF ACCESS HATCH AND LADDER. SEE DETAIL B1/A701. N