Loading...
HomeMy WebLinkAbout021 A101 Building A - Floor Plan - Level 1UP D D 1 1 4'-0 1/2"4'-0 1/2" 24'-9"3'-2"12'-8"3'-2"6'-4"12'-6" 5 15/16" 5'-6 1/16" STORAGE 107 MAINTENANCE 105 BIKE/SKI REPAIR 106 FIRE RISER 101 B2 A302 D2 A301 4'-0"D4 A352 SPA MECHANICAL 104 CHEMICAL 103 CHEMICAL 102 B B 74'-4" 4 4 2 2 3 379'-3"37'-1"5'-1"37'-1"5 15/16"11'-2"9'-1"11'-10"1'-8"1'-10"1'-6"1'-6"1'-10"1'-8"10'-10"16'-1"5'-2"74'-4" 5'-0"11"17'-2"1'-8"3'-2"12'-8"3'-2"18'-10"79'-3"37'-1"5'-1"37'-1"1'-6"1'-10"1'-8"11'-10"8'-9"1'-8"9'-10"20'-5"11'-8"1'-8"1'-10"1'-6"1'-0"1'-0"1'-6" 11'-9" 7'-0" 1'-6" 2'-6" 7'-0" 7'-0"1'-0"1'-0"8"6'-0" 9" B2 A301 C C BA BB B AD C C C C B B B D A D D E A A C C A101 A106A107 A105 A104A103A102 AD2 AD1 AD1 AD1 AD2 AD2 D1 A352 D3 A352 6'-0"62'-7"5'-9" 6'-0"62'-7"5'-9" A102 2-1000 TYPE B A101 3-1263 TYPE B A104 2-1000 TYPE B BEDROOM CLOSETMECHBATHROOM LAUNDRY MASTER BATH CLOSET PANTRY LIVING KITCHEN KITCHEN LIVING BATHROOM LAUNDRY BEDROOM MASTER BEDROOM CLOSET MASTER BATH MECH PANTRYPANTRY MASTER BATH 2 MASTER BEDROOM 2 BEDROOM 1 MASTER BEDROOM 1 CLOSET MASTER BATH 1LAUNDRY BATHROOM MECH LIVING KITCHEN CLOSETCLOSET AD5 AD3 AD5 AD4 AD4 AD5 AD3 AD5 AD4 AD3 AD4 AD5 AD5 AD4 AD5 AD4 AD3 AD3 AD5AD4 AD5 AD7 4'-0" AD6 AD6AD6 AD7 AD7 AD3AD5 AD3 5'-9 3/4" 3'-8 1/4" 3'-0" 6 1/2" 2'-4 1/2" 3'-5"1'-7"1'-7"1'-6" 2'-0" 3'-0" 2'-8" 2'-3 3/16" 1'-2 13/16" 1'-7" 1'-2 5/8" 4 3/8" 3'-8" 2'-4 5/8" 3'-4 3/8" 7'-9" 3'-10" 2 3/4" 3'-6 1/4" 6 1/2" 5'-2 1/2"5'-3 1/2"3 1/2"5'-7"3'-4"2'-8"2'-8 3/4"4 1/4"2'-6"3'-5"3'-5"2'-6"2'-0"3'-5"3'-5"2'-0"1'-0 13/16"5'-4 3/4"9'-7 7/16"2'-6"2'-8"3'-4" 2'-8" 5'-10" 3'-8 1/16" 3'-6 3/4" 2'-4 1/4" 3'-5" 1'-7"1'-7" 1'-6 1/4" 1'-11 3/4" 3'-0" 2'-4" 3'-10" 1'-7"1'-7"4'-7 3/8"5'-2 5/8"5'-10"6'-0"3'-2"5'-7"2'-5" 3'-5" 3'-5" 2'-5" 1'-5" 2'-7" 2'-9 3/4"2'-4 3/4"3'-2 1/2" 8'-0" B 3'-2 5/16" 8'-6 1/2" 5'-5 3/16" CB B D A D D C C C D F G E HH H HH B A 5'-2 15/16" 6'-0 13/16" 4'-0 3/4" 4'-0 3/4" 6'-0" 4 3/4" 2'-8"4'-4 3/4"6'-0 3/4"3'-1 1/8" 6" 5'-4 3/4" 2'-4 3/4" D D F G E D DE G F D A A A C C D A C D J D G G G A C G G G A D D F G E H H H H D L L L 4'-3" 4'-2"3'-8"N N Q Q N N N N N N MM N Q Q N QQ N N N L L L Q Q C N Q Q N N NN N Q Q N N N M N N N M Q P N QQ N N QQQ N N N N NN N MJ Q N Q N N N N N N NN N Q N M N N QQ N N N 2'-9 13/16" 1 3/4"6'-0"4'-0 3/4" 4'-4 3/4" 6'-4 3/4" 2'-6" 1'-9 1/8"6"2'-0 5/16"3'-4 7/16" 4'-4 3/4"6'-9 3/4" 2'-4 3/4" 5'-4 3/4"8"2'-11 1/8"2'-5 9/16" 2'-6 5/8" 6'-3 13/16" 4'-0 3/4" 4'-0 3/4"6'-0" 4 3/4" 2'-7 3/4" NN J J J J K K K K K K6'-0 3/4"4'-4 3/4"D D D 1'-10"1'-10"1'-10" 1'-10" D1 A353 01.02 01.02 04.22 04.22 01.0104.31 04.31 02.54 02.54 02.54 PATIO PATIO PATIO CORRIDOR Q H D D 03.13 03.13 03.13 ONE-HALF-HOUR CORRIDOR (FIRE PARTITION) ONE-HOUR-FIRE-RESISTANT CONSTRUCTION (TYPE V-B) ONE-HALF-HOUR DWELLING SEPARATION (FIRE PARTITION) ONE-HOUR-FIRE-RESISTANT CONSTRUCTION (TYPE V-B) SEPARATION LEGEND A. GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR CONSTRUCTION. REPORT ANY SIGNIFICANT DISCREPANCIES TO THE ARCHITECT. B. COORDINATE INSTALLATIONS OF ALL "AFTER CONTRACT" ASSEMBLIES WITH OWNER PRIOR TO CONSTRUCTION OF ADJOINING OR RELATED STRUCTURES. C. PROVIDE 18" MINIMUM CLEAR FLOOR SPACE AT PULL SIDE OF ALL DOORS. PROVIDE 12" MINIMUM CLEAR FLOOR SPACE AT PUSH SIDE OF ALL DOORS. D. UNLESS OTHERWISE NOTED OR DIMENSIONED, LOCATE DOORS AS FOLLOWS: • MASONRY WALLS- OUTSIDE OF FRAME 8" FROM FACE OF WALL (ON BLOCK MODULE), • FRAMED WALLS-INSIDE OF JAMB 4" FROM FINISHED WALL (ADJUST FOR TILE WHERE SHOWN). E. CONCRETE FOUNDATION WALLS RETAINING EARTH TO RECEIVE TWO COATS OF BITUMINOUS DAMP PROOFING MATERIAL. F. AN AUTOMATIC FIRE SPRINKLER SYSTEM IS TO BE INSTALLED THROUGHOUT THE ENTIRE BUILDING PER NFPA 13R. G. SEE STRUCTURAL, MECHANICAL, AND ELECTRICAL SHEETS FOR ADDITIONAL INFORMATION H. SEE INTERIOR ELEVATIONS ON AI201 AND MILLWORK DETAILS ON AI551 FOR FINISHES OF MILLWORK BASES, AND COUNTERTOPS SEE SHEETS A151, A152 FOR REFLECTED CEILING PLAN INFORMATION. I. SEE SHEETS AI101, AI102, FOR FINISH INFORMATION. CONFIRM FINISHES WITH OWNER PRIOR TO ORDERING. J. SEE A601, A602, AND A603 FOR DOOR AND WINDOW INFORMATION. K. GENERAL CONTRACTOR SHALL REVIEW AND APPROVE ALL APPLIANCES WITH OWNER PRIOR TO PURCHASING EQUIPMENT AND FABRICATING MILLWORK. L. SEE THE SPECIFICATION FOR ADDITIONAL INFORMATION. M. SEE G000 FOR LEGENDS, SYMBOLS, ABBREVIATIONS AND OTHER ARCHITECTURAL GENERAL INFORMATION. N. SEE G003 FOR WALL TYPES. O. PROVIDE BACKING/BLOCKING FOR WALL MOUNTED ITEMS-INCLUDING GRAB BARS, HANDRAILS, SIGNAGE AND EQUIPMENT AS REQUIRED. P. TILE IS TO BE SET OVER CEMENTITIOUS BACKER BOARD UNDERLAYMENT. RECESS SLAB AS/IF REQUIRED. VERIFY WITH OWNER. Q. DO NOT SCALE DRAWINGS. GENERAL NOTES SCALE: 3/16" = 1'-0"A101 FLOOR PLAN - LEVEL 1D2 233 SOUTH PLEASANT GROVE BLVD. SUITE #105 PLEASANT GROVE, UTAH 84062 PHONE: (801) 769-3000 core@corearch.com NOT FOR CONSTRUCTION THE INFORMATION HEREIN IS THE PROPERTY OF CORE ARCHITECTURE AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2023 CORE ARCHITECTURE, LLC PROFESSIONAL STAMP SHEET NUMBER SHEET TITLE A 1 REVISIONS DATE: PROJECT #: PM / PA: PIC: PROJECT INFORMATION DESCRIPTION DATE THIS DRAWING SET IS INTENDED TO BE PRINTED IN COLOR CONSULTANT INFORMATION DRAWING SET STATUS B C D 2 3 4 5 6 PROJECT TITLE AND ADDRESS8/3/2023 12:22:52 PMAutodesk Docs://23-029 Bozeman Multifamily/23-029 Bozeman Multifamily Building A.rvtFLOOR PLAN - LEVEL 1 A101 28 JULY 2023 23-029 MRR MMA PERMIT REVIEW & BID DOCUMENTSBOÖTES - BUILDING AOPPORTUNITY WAY AND SOUTH11TH AVEBOZEMAN, MONTANA 59718KEYNOTES 01.01 ADA COMPLIANT SEMI RECESSED FIRE EXTINGUISHER CABINET WITH 2A10BC FIRE EXTINGUISHER INSIDE. SEE DETAIL D1/A701. 01.02 ADA COMPLIANT "STAIRWAY" SIGN. SEE SHEET G002. 02.54 42" HIGH PATIO GUARDRAIL. SEE DETAILS ON SHEET A505. 03.13 STRUCTURAL COLUMN. SEE STRUCTURAL. 04.22 PREFINISHED METAL HANDRAIL 36" ABOVE FINISHED FLOOR OR NOSE OF STAIRS. SEE TYPICAL APT DETAILS ON SHEET A452. 04.31 27" MAXIMUM TALL GUARDRAIL, TO PROVIDE BLIND CANE DETECTION. EXTEND WHERE MINIMUM 84" OVERHANG CLEAR IS NOT PROVIDED. N