Loading...
HomeMy WebLinkAbout016 A0.2 North Wallace Residence SPECIFICATIONSROOF DIVISION 07 4113 METAL PANEL:MANUF BASIS OF DESIGN: GREAT NORTHERN METAL COMPANYTYPE: BOX RIBTHICKNESS: 24 GA.COLOR: BLACK RAWHIDE FASTENERS: EXPOSED, WITH NEOPRENE WASHER.PREDRILL ALL PANELS TO PREVENT OIL CANNING.LENGTH: PROVIDE FULL LENGTH SHEETS WITH NO SEAMS. METAL TRIMS AND DRIPEDGE TO MATCH COLOR OF METAL ROOF U.N.O. SEE X/A5.1 FOR PROFILES AND COORDINATE WITH WINDOW AND DOOR TRIMS PROFILES.THICKNESS: 26 GA MIN. (BEND BACK AT LOCATIONS VISIBLE) METAL SOFFIT:MANUF BASIS OF DESIGN: GREAT NORTHERN METAL COMPANYTYPE: 0.5" V SOFFITSOFFIT PANELS - MATTE BLACK SIDING DIVISION 07 4213 METAL WALL PANELSMANUFACTURER: GREAT NORTHERN METAL (BASIS OF DESIGN)FINISH: WEATHEREDPROFILE: CORRUGATEDORIENTATION: VERTICALTHICKNESS: 24 GAUGEFASTENERS: EXPOSED, MATCH COLORS WITH NEOPRENEWASHER. PREDRILL ALL PANELS TO PREVENT OIL CANNINGLENGTH: PROVIDE FULL LENGTH SHEETS WITH NO SEAMS DIVISION 07 4600 EXTERIOR BOARD AND BATTEN:MANUFACTURER: SUBSTITUTIONS APPROVED BY ARCHITECT. PRODUCT: WOODSPACING: RANDOM WIDTHS ORIENTATION: VERTICALFINISH: SHOSHUGIBANCAULKING: COLOR MATCH OR BLACK. EXTERIOR BOARD AND BATTEN:MANUFACTURER: SUBSTITUTIONS APPROVED BY ARCHITECT. PRODUCT: WOODSPACING: 12" PANELS WITH 2X4 BATTENSORIENTATION: VERTICALFINISH: STAIN TBD PER OWNER AND ARCHITECTCAULKING: COLOR MATCH OR BLACK. EXTERIOR BOARD AND BATTEN:MANUFACTURER: SUBSTITUTIONS APPROVED BY ARCHITECT. PRODUCT: WOODSPACING: 8" PANELS WITH 1X4 BATTENSORIENTATION: HORIZONTALFINISH: PAINT BLACK - SHERWIN WILLIAMS TRICORN BLACK OR SIMILARCAULKING: COLOR MATCH OR BLACK. EXTERIOR PINE SIDING:THERMALLY MODIFIED PINEMANUFACTURER: THERMORY (AESTHETIC BASIS)- BASIS OF DESIGN - RECOMMEND PRICING SUBSTITUTIONS ALLOWED WITH REVIEW BY ARCHORIENTATION: HORIZONTALFINISHES: OILEDSIZE: 1 X 6 DIVISION 07 4646 METAL TRIMS AND DRIPEDGE:IF SEAMS ARE REQUIRED, USE BEAD MASTIC AT SEAMSTYPICAL TRIMS: J METAL WITH 1" EXPOSED FINLOCATIONS FOR TRIMS: CORNERS, WINDOW HEAD SILL AND JAMBS, TOP AND BOTTOM OF PANELS, EXPOSED OR ABUTTED TO ADJACENT MATERIALS.THICKNESS: 29 GA MIN. (BEND BACK AT LOCATIONS VISIBLE)PREFINISHED BLACK FINS AND DRIPEDGE FOR ALL METAL TRIM LOCATIONS AROUND WINDOWS AND DOORS. SEE HARDIE PANELS FOR REVEAL TRIMS. WOOD TRIM:LOCATION: WINDOWS AND DOORS 1 X 6 PREFINISHED STAIN. COLOR: PER ELEVATIONSSUBSTITUTE: APPROVED BY OWNER, ARCHITECT, AND GC LOCATION: BASE AND BELLY BANDS 1 X 10 PREFINISHED STAIN. COLOR: PER ELEVATIONSSUBSTITUTE: APPROVED BY OWNER, ARCHITECT, AND GC DOOR AND WINDOW DIVISION 08 1113 EXTERIOR DOORS:BASIS OF DESIGN: 100 SERIES ANDERSEN SUBSTITUTE: APPROVED BY OWNER, ARCHITECT, AND GC INTERIOR DOORS:BASIS OF DESIGN: EIGHTDOORS. SHAKER WHITE PRIMED SOLID CORE WOOD INTERIOR SLAB DOORSUBSTITUTE: APPROVED BY OWNER, ARCHITECT, AND GC ACCESSORIES: DIVISION 08 5413 EXTERIOR WINDOWS:MANUFACTURER BASIS OF DESIGN: ANDERSENPRODUCT: 100 SERIESTYPE: VINYL (this manuf only, substitutions shall be fiberglass or aluminum clad wood windows)GLAZING: TINTEDCOLOR: BLACK INTERIOR: BLACKINSULATION: HIGH ALTITUDE ARGON FILLED LOW E 366 ANNEALED GLASSU FACTOR: .26SHGC: .22 minENERGY RATING: 12JAMB: 6 9/16", 4/4 THICK ACCESSORIESGRILLES: PER ELEVATION, MATCH SASH COLOR (BETWEEN GLASS)NAIL FIN: ATTACH PER MANUF.CAULK: AS REQUIRED PER MANUF.CAULK COLOR: BLACKHARDWARE: BLACKSCREEN: BETTER VUE (HIGH VIABILITY OUT) OVERHEAD DOORS:MANUFACTURER BASIS OF DESIGN: CLOPAYPRODUCT: PER OWNER BY LOCATIONTYPE: OVERHEAD DOORCOLOR: MATTE BLACKINTERIOR: MATTE BLACKINSULATION: R-9 SUBGRADE DIVISION 07 1113 DAMPPROOFING MEMBRANE:BASIS DESIGN: PRODUCT PER GENERAL CONTRACTORFLUID APPLIED FOUNDATION WALLS - COORDINATE WITH WATERPROOFING AREASFIBERED EMULSION DAMPPROOFING: BRUSH OR SPRAY APPLIED, GENERAL PURPOSE COATING. MANUFACTURED WITH REFINED ASPHALT, CLAY EMULSIFIERS, AND NON - ASBESTOS FIBERS. CURES TO A TOUGH FLEXIBLE, DURABLE FINISH AND RESISTS VARIATIONS IN TEMPERATURE - LOW ODOR. COVERAGE 4 TO 6 GALLONS PER 100 SFCOLOR: BLACKPERMEANCE: .5 PERMS MINIMUMCURE TIME 24-48 HOURSTEMPERATURE -5 TO 180 DEGREES F.CHEMICAL RESISTANCE: ACIDS, ALKALINE, SALTS.WATERPROOFING REQUIREMENTS WITH GEOTECHNICAL REPORT SEE CIVIL , LANDSCAPE, MECHANICAL, ELECTRICAL, AND SEE CIVIL , LANDSCAPE, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR MORE SPECIFICATIONS.PLUMBING DRAWINGS FOR MORE SPECIFICATIONS. INTERIOR FINISH DIVISION 07 4113 FLOORING: TBD BY OWNER DIVISION 08 MISC ACCENT WD INTERIOR FINISH: NONE PROPOSED LOCATIONS: NONE COUNTERTOPS:TBD BY OWNER CABINETS:TBD BY OWNER PAINT:COLOR PER OWNERS SELECTIONS - AW ALABASTER WHITE - CONFIRM TONAL MOCK - UPS WITH OWNERSATIN ON WALLSFLAT ON CEILINGS GWB FINISH:LEVEL 4 TROWELED FINISH. PROVIDE ONSITE SAMPLES OF TOWELING OPTIONS. BATHROOM CLEANABLE WALL SURFACE PER IRC TBD BY OWNER TYPICAL BASE TRIM: TBD BY OWNER CONSTRUCTION SPECIFICATIONS DIVISION 01 ---- GENERAL REQUIREMENTS: 01-2000SUBSTITUTION REQUIREMENTS:SUBSTITUTION REQUESTS REPRESENT SUBMITTER:1) HAS INVESTIGATED PROPOSED SUBSTITUTIONS TO DETERMINE IT MEETS OR EXCEEDS SPECIFIED;2) AGREES TO PROVIDE SAME WARRANTY FOR SUBSTITUTION AS FOR SPECIFIED;3) AGREES TO COORD. INSTALL. AND MAKE CHANGES TO OTHER WORK AS REQ'D TO COMPLETE WORK, AT NO ADD'L COST TO OWNER;4) SHALL DETERMINE ANY COST OR SCHEDULE CHANGES DUE TO SUBSTITUTION, AND SHALL NOTIFY ARCHITECT FOR APPROVAL THEREOF. REQUESTS SHALL BE DOCUMENTED BY SUBMITTER. INCL. ALL INFO REQ'D FOR TRACKING REQUEST, & NEEDED FOR ACTIONABLE RESPONSE. LIMIT EACH REQUEST TO A SINGLE PROPOSED SUBSTITUTION ITEM, WITH ELECTRONIC DOCUMENT SUBMITTED TO ARCHITECT. ARCHITECT MAY REQUEST FURTHER INFO & DOCUMENTATION PRIOR TO DECISION, & SHALL NOTIFY CONTRACTOR IN WRITING OF DECISION. ACCEPTED SUBSTITUTIONS CHANGE THE WORK OF THE PROJECT, & WILL BE DOCUMENTED & INCORPORATED INTO THE WORK OF THE PROJECT AS PROVIDED FOR IN THE CONTRACT. 01-4000QUALITY REQUIREMENTS:ANY INDIVIDUAL RESPONSIBLE FOR DESIGN-RELATED SERVICES PROVIDED BY CONTRACTOR WILL BE SUBMITTED TO ARCHITECT FOR APPROVAL, INCLUDING FULL NAME, PROFESSIONAL LICENSURE, & EXTENT OF RELEVANT EXPERIENCE IN DESIGN OF ITEMS ASSIGNED TO CONTRACTOR. DESIGN CONCEPT AND DESIGN, INCL. ALL REQ'D PRODUCT DATA, SHOP DRAWINGS, & DETAILS, SUBMITTED TO ARCHITECT FOR APPROVAL. QUALITY WILL BE CONTROLLED BY:1) MONITORING TO MEET SPECIFIED QUALITY;2) COMPLYING WITH MANUF. INSTRUCTIONS;3) REQUESTING CLARIFICATION FROM ARCHITECT;4) COMPLYING WITH SPECIFIED STANDARDS EXCEPT WHERE HIGHER STANDARDS INDICATED BY TOLERANCES, CODES, OR REQ'S;5) HAVING WORK PERFORMED BY QUALIFIED PERSONS;6) VERIFYING FIELD MEASUREMENTS;7) SECURING PRODUCTS. 01-6000PRODUCT REQUIREMENTS:SUBMIT MANUF'S STANDARD DATA FOR ALL PRODUCTS; MARK EACH COPY TO IDENTIFY APPLICABLE PRODUCTS, MODELS, OPTIONS, AND OTHER DATA, & SUPPLEMENT WITH ANY INFO REQ'D TO SUIT THIS PROJECT; SUBMIT SHOP DRAWINGS PREPARED SPECIFICALLY FOR THIS PROJECT, & INDICATE UTILITY & ELECTRICAL CHARACTERISTICS, CONNECTION REQUIREMENTS, & LOCATION OF OUTLETS; ILLUSTRATE FUNCTIONAL & AESTHETIC CHARACTERISTICS OF PROJECT WITH SUBMITTED SAMPLES, WITH INTEGRAL PARTS & ATTACHMENT DEVICES; COORD FOR INTERFACING WORK. PROVIDE THE FOLLOWING PRODUCT INFORMATION FOR REVIEW AND APPROVAL BY THE ARCHITECT:1) WINDOWS AND DOORS, & RELATED HARDWARE2) SIDING MATERIALS3) TRIM4) COLORS FOR FINISHES OF STAINS & PAINTS5) PLUMBING FIXTURES6) SHOWER ENCLOSURES & HARDWARE7) ANY STEEL FAB. OR PRODUCTS FOR RAILS8) Interior Finish Samples or product data to confirm design intent and selection with owner PRODUCTS SPECIFIED BY REFERENCE STANDARDS OR DESCRIPTION ONLY SHALL USE ANY PRODUCT MEETING THOSE STANDARDS OR DESCRIPTION; PRODUCTS SPECIFIED BY NAMING ONE OR MORE MANUFACTURERS SHALL USE ONE OF THE NAMED MANUFACTURERS AND MEETINGS SPECIFICATIONS, WITH NO OTHER SUBSTITUTIONS ALLOWED; PRODUCTS SPECIFIED BY NAMING ONE OR MORE MANUFACTURERS WITH A PROVISION FOR SUBSTITUTIONS SHALL SUBMIT A REQUEST FOR SUBSTITUTION FOR ANY MANUFACTURER NOT NAMED. 01-7000EXECUTION AND CLOSEOUT REQUIREMENTS:EXECUTE WORK TO AVOID CUTTING OR PATCHING, ONLY PERFORMING WHAT IS NECESSARY TO:1) COMPLETE THE WORK2) FIT PRODUCTS TOGETHER WITH OTHER WORK3) PROVIDE OPENINGS FOR PENETRATIONS4) MATCH CUT WORK TO ADJACENT WORK5) REPAIR AREAS ADJ. TO CUTS TO REQ'D CONDITION6) REPAIR NEW WORK DAMAGED BY LATER WORK7) REMOVE SAMPLES OF INSTALLED WORK FOR TESTING WHEN REQUESTED8) REMOVE & REPLACE DEFECTIVE & NON-COMPLYING SUBMIT WRITTEN REQUEST IN ADVANCE OF ALTERATION AFFECTING STRUCTURAL INTEGRITY OF ANY ELEMENT, INTEGRITY OF WEATHER-EXPOSED OR MOISTURE-RESISTANT ELEMENTS, OR EFFICIENCY, MAINTENANCE, OR SAFETY OF ANY OPERATIONAL ELEMENT. PATCHING MAT'LS SHALL MATCH EXISTING PRODUCTS & WORK AS SPECIFIED IN PRODUCT SECTIONS; DETERMINE QUALITY BY INSPECTING & TESTING WHERE NEEDED, WITH EXISTING WORK AS STANDARD. INSTALL PRODUCTS AS SPECIFIED IN INDIV. SECTIONS, PER MANUF. INSTRUCTIONS, AND SO AS TO AVOID WASTE DUE TO NECESSITY FOR REPLACEMENT; ALL VERTICAL ELEMENTS TO BE PLUMB, AND HORIZONTAL ELEMENTS TO BE LEVEL, UNLESS NOTED OTHERWISE; INSTALL EQUIPMENT AND FITTINGS PLUMB AND LEVEL, NEATLY ALIGNED WITH ADJACENT VERTICAL & HORIZONTAL LINES, UNLESS NOTED OTHERWISE; MAKE CONSISTENT TEXTURE ON SURFACES, WITH SEAMLESS TRANSITIONS, UNLESS NOTED OTHERWISE; MAKE NEAT TRANSITIONS BETWEEN DIFFERENT SURFACES, MAINTAINING TEXTURE AND APPEARANCE. EXECUTE WORK TO AVOID DAMAGE TO OTHER WORK AND TO PROVIDE APPROPRIATE SURFACES TO RECEIVE PATCHING AND FINISHING; MINIMIZE DAMAGE TO EXISTING WORK, AND RESTORE TO ORIGINAL CONDITION. FINISH PATCHED SURFACES TO MATCH FINISH PRIOR TO PATCHING; ON CONTINUOUS SURFACES, REFINISH TO NEAREST INTERSECTION OR NATURAL BREAK; FOR AN ASSEMBLY, REFINISH ENTIRE UNIT. MAINTAIN AREAS FREE OF WASTE, DEBRIS, AND RUBBISH; MAINTAIN SITE IN CLEAN AND ORDERLY CONDITION. PROTECT INSTALLED WORK FORM DAMAGE BY CONSTRUCTION; PROVIDE SPECIAL PROTECTION WHERE SPECIFIED IN INDIV. SPEC. SECTIONS; REMOVE PROTECTIVE COVERINGS WHEN NO LONGER NEEDED (REUSE OR RECYCLE IF POSSIBLE). USE CLEANING PRODUCTS THAT ARE NON-HAZARDOUS; CLEAN INT. & EXT. GLASS, SURFACES EXPOSED TO VIEW, REMOVE TEMP. LABELS, STAINS, AND FOREIGN SUBSTANCES, POLISH TRANS. & GLOSSY SURFACES, AND VACUUM CARPETED OR SOFT SURFACES. REMOVE ALL NON-PERMANENT LABELS; DO NOT PAINT OR OTHERWISE COVER FIRE TEST LABELS OR NAMEPLATES ON MECH. OR ELECT. EQUIPMENT. CLEAN EQUIPMENT AND FIXTURES TO SANITARY CONDITION WITH CLEANING MATERIALS APPROPRIATE TO SURFACE AND MATERIAL BEING CLEANED. NOTIFY ARCHITECT WHEN WORK IS CONSIDERED READY FOR SUBSTANTIAL COMPLETION INSPECTION; SUBMIT WRITTEN CERT. CONTAINING CONTRACTOR'S CORRECTION PUNCH LIST, THAT CONTRACT DOCUMENTS HAVE BEEN REVIEWED, WORK HAS BEEN INSPECTED, AND WORK IS COMPLETE IN ACCORDANCE WITH CONTRACT DOCUMENTS AND READY FOR ARCHITECT'S SUBSTANTIAL COMPLETION INSPECTION; NOTIFY ARCHITECT WHEN WORK IS CONSIDERED FINALLY COMPLETE AND READY FOR ARCHITECT'S SUBSTANTIAL COMPLETION FINAL INSPECTION; COMPLETE ITEMS OF WORK DETERMINED BY ARCHITECT LISTED IN EXECUTED CERTIFICATE OF SUBSTANTIAL COMPLETION. EXTERIOR COLOR AND MATERIAL PALETTE 11 WINDOWS AND DOORS:BLACK COLOR 100 SERIES ANDERSEN TRIMS:STAINED WOOD TRIMS AT WINDOWS, AND DOORS, TYPICAL. - COLORS PER ELEVATIONS SEALANT: BLACK 22 33 ROOFING: BOX RIB 1 1/2" - 7.2" CENTERSCOLOR: MATTE BLACK 55 44 77 OVERHEAD DOOR:COLOR: MATTE BLACK88 66 TRELLIS ARMATUREMATERIAL: COLD ROLLED STEELFINISH: POWDER COATEDCOLOR: MATTE BLACK SIDING: BOARD AND BATTEN PROFILE: 2X4 OVER 12" PANELSFINISH: STAIN COLOR PER OWNER SIDING: THERMALLY MODIFIED PINEPROFILE: 6" WITH 1/8" REVEALFINISH: STAIN COLOR PER OWNER SIDING: BOARD AND BATTEN PROFILE: RANDOM WIDTHSFINISH: SHOSHUGIBAN SIDING: CORTENPROFILE: CORRUGATEDFINISH: WEATHERES 99 SIDING: BOARD AND BATTEN HORISONTAL PROFILE: 1X4 OVER 8" PANELSFINISH: PAINT TRICORN BLACK DRAWING NUMBER: REVISIONS:0"1"2"PHASE: DATE: DRAWING TITLE: PROJECT NUMBER: DRAWN BY / CHECKED BY:10/6/2023 3:50:40 PMA0.2 NORTHWALLACERESIDENCES 428 NORTH WALLACEBOZEMAN, MT SPECIFICATIONS 21-23 OCT 6, 2023 ML CCR SITE PLAN APP 4 4 44 1 1 1 11 2 2 2 7 1 3 5 6 8 8 8 9 NO.DESCRIPTION DATE 1 SP PreScreenR1 10/31/22