Loading...
HomeMy WebLinkAbout045.1 Irrigation Details 1WGMGROUPWWW.WGMGROUP.COMIRRIGATION DETAILS 14TH & PATRICK AFFORDABLE HOUSING BOZEMAN, MONTANAMAY 26, 2023L2.2NTSWALL MOUNTED CONTROLLER1DETAILNotes:1- Common and controller wire to be bundled using electrical tape at 10'-0" on center.2- Grounding rods shall be located between 8"- 0" to 12'- 0" away from the controller. Grounding rods shall be 38" in diameter x 8' in length. Connectthe grounding rod to the controller using 6 gauge bare copper wire or per the manufacturer's specifications.See grounding rod detail.3- ET Station shall be installed no further than 90' away from the controller and a minimum of 15' off of the ground, out from under any overheadobstructions such as, but not limited to, building overhangs, trees, or utilities.Wall, fence, or building.Wall mounted controller. Install permanufacturer's specifications andrecommendations. (See irrigation legendfor controller make and model number).34" knockout for earth ground wire.2" PVC electrical conduit for irrigationvalves, master valve, and flow sensor wires.Optional 3" knockout if more wires are needed.Secure conduit to wall using stainless steel clamp.1" PVC electrical conduit for electrical power perlocal and national electrical codes.1" PVC electrical conduit for ET sensor.(optional).SIDE VIEWSECTION VIEWFinishedgrade.18" Min.212"MULCHFINISH GRADEGRATED CAPHUNTER 0.25 GPMPCB BUBBLERHUNTER HVCCHECK VALVE (OPTIONAL)PATENTED STRATAROOT ASSEMBLYHUNTER SWING JOINT(OPTIONAL)LATERAL TEE OR ELLLATERAL PIPEROOT INTRUSION BARRIERCOMPRESSION FITTING.PLANT GRAPHICDRIPLINE EDGE.TYPICAL 1/4" TUBE STAKE WITH EMITTER OR CAP.TYPICAL 1/4" DISTRIBUTION TUBING, 48" MAX. LENGTH.TYPICAL 1/2" DRIP TUBING STAKE.MULTI-OUTLET EMITTER OR TRANSFER.EMITTER OR BUBBLERON 12" DRIP STAKE.TRANSFER BARB TEEFOR DOUBLE EMITTER.TYPICALCOMPRESSIONFITTING.TYPICAL 12"DRIP TUBING.NOTE:1. PLACE EMITTERS 34 BETWEEN THE TRUNK AND OUTTER DRIPLINE.2. EVENLY SPACE EMITTERS AROUND PLANT.3. STAKE THE DRIP TUBING AT EACH TEE, ELL, COUPLER, AT EACH EMITTER OR TRANSFER, AND AT 6'-0" MAX O.C.NTS18" ROOT ZONE WATERING SYSTEM3DETAILNTSTYPICAL DRIP TUBING2DETAIL18" MIN. LENGTH OF FLEXIBLEPOLYETHYLENE PIPE TOCORRESPOND WITH MNF. OFHEAD. ALL FITTINGS TO BE BYSAME MNF.TOP OF HEAD TO BE 12" - 1" ABOVEGRADE IN TURF AREAS.SPECIFIED MULCH1'-0"LATERAL LINEBARB ELLSCH. 40 PVC -TEE OR ELL ATLAT. LINEPOP-UP SPRAY SPRINKLERSPECIFIED TOPSOILPVC SCH. 40 - 90-DEG. STREET ELLBARB ELL2"NTSMP ROTATOR POP UP SPRINKLER7DETAILNTSSLEEVING6DETAILNTSDRIP VALVE INSTALLATION8DETAILNTSDRIP DRAIN VALVE DETAIL9DETAILPAVEMENT FINISH GRADEPAVEMENT SECTIONDETECTABLE METALLIC UNDERGROUNDWARNING TAPE CENTERED OVER HORIZONTALLOCATIONS OF MAIN AND LATERAL LINESTRENCH BACKFILL, 6" MIN. SAND FILL ABOVESLEEVESPECIFIED SLEEVEMAIN OR LATERAL LINEUNDISTURBED SUBGRADE18-24" COILED WIREWATERPROOF CONNECTORS (2)JUMBO VALVE BOXDRIP ZONE KITMODEL ICZ-151-XL-40 WITHFILTER (TIP 45 DEGREES)REGULATOR 25 OR 40 PSISCH 80 T.O.E. NIPPLE(2)MAIN LINE PIPE & FITTINGSBRICK SUPPORTS (4)3/4" MINUS WASHED GRAVELFINISH GRADENOTE: PROVIDE DRAIN ATDEAD-END LOCATIONS ONALL DRIP SUPPLY LINES.SEE PLANS1/2"DRAIN VALVEVALVE BOX8" DIA.FINISH GRADE4" PEAGRAVEL6"1" DRIPSUPPLY TYP.FINISH GRADENOTE:1.FURNISH FITTINGS ANDPIPING NOMINALLY SIZEDIDENTICAL TO NOMINALQUICK COUPLING VALVEINLET SIZE.SPECIFIED TOP SOILTOP OF BOX 12" ABOVEFINISH GRADE IN TURF. 1"ABOVE FINISH GRADE INGROUNDCOVER AREAS10"∅ ROUND PLASTIC VALVEBOX WITH LOCKING LIDPVC SCH. 80 NIPPLE(LENGTH AS REQ.)4" MIN DEPTH OF 34"WASHED GRAVELPVC SCH. 40 TEE OR ELLMAINLINEPVC SCH. 40 STREET ELLNO. 4 GALVANIZED STEEL REINFORCING BAR(DEFORMED) WITH 2 STAINLESS STEEL GEARCLAMPS SECURED TO QUICK COUPLERASSEMBLY AS SHOWN.NTSQUICK COUPLER4DETAILPVC SCH. 80 NIPPLE(LENGTH AS REQ.)NOTE: ROTATOR MODEL TO BEBASED ON ACHIEVINGHEAD-TO-HEAD COVERAGE:MP1000: 8' - 15' RADIUSMP2000: 13' - 21' RADIUSMP3000: 22' - 30' RADIUSMP35000: 30' - 35' RADIUSNTSREMOTE CONTROL VALVE DETAIL5DETAILVALVE BOX WITH LOCKING LID, TOP OFBOX 12" ABOVE FINISH GRADE IN TURF.1" ABOVE FINISH GRADE INGROUNDCOVER AREASCONTROLLERVALVE IDENTIFICATION TAGREMOTE CONTROL VALVEPVC UNION TYPICAL OF 2LATERAL LINESPECIFIED TOP SOILCOMMON BRICK, ONE REQUIRED ATEACH CORNER OF VALVE BOX34" WASHED GRAVELBALL VALVE, LINE-SIZED TOMATCH REMOTE CONTROLVALVESCH. 40 45-DEG. ELLADDED SHEET8/22/23PRELIMINARYPLOTTED:SAVED:8/22/238/22/23