Loading...
HomeMy WebLinkAbout014-G1-2 - GENERAL NOTESPROJECT DESCRIPTION: 1. APPLICABLE CODES: 2021 INTERNATIONAL ENERGY CONSERVATION CODE 2021 INTERNATIONAL BUILDING CODE 2021 INTERNATIONAL FUEL GAS CODE 2020 NATIONAL ELECTRICAL CODE 2021 UNIFORM PLUMBING CODE 2021 INTERNATIONAL MECHANICAL CODE 2017 ICC/ANSI A117.1 PROJECT INFO & CODE ANALYSIS: ZONING SUMMARY: INTERIOR ENVIRONMENT: JURISDICTION: CITY OF BOZEMAN ZONING: R-3 - CATTAIL CREEK SUBDIVISION PH3 *ALLOWABLE BLDG. HEIGHT: 40 FEET BUILDING LOT AREA: 23,958 SF, 0.555 ACRES LEGAL LOT AREA ALLOWED (ZONING CODE REFERENCE): FULL COVERAGE OF BLOCK EXCEPT FOR YARD SETBACKS YARD SETBACKS (ZONING CODE REFERENCE): FRONT YARD: 15 FT. SIDE YARD: 5 FT. BACK YARD: 20 FT. DENSITY: FOOT PRINT: 3,760 SF NET AREA: 11,205SF PER 5-PLEX FAR OF THE SITE: 94% EXISITNG BUILDIGN AREA: N/A NET RESIDENTAL DENSITY: 10 UNITS 18.02 UNITS PER ACRE VENTILATION (1202): NATURAL VENTILATION REQUIRED (1202.5) TEMPERATURE CONTROL (1203): HEATING SYSTEM MUST BE CAPABLE OF MAINTAINING AN INDOOR TEMPERATURE OF ≥68° F. LIGHTING (1204): 8% MIN. OF NATURAL LIGHT REQUIRED (1204.2) 10 FOOTCANDLES AVG ARTIFICIAL LIGHTING REQ'D (1204.3) SOUND TRANSMISSION (1206): 50 MIN. SOUND TRANSMISSION CLASS REQ'D BETWEEN SLEEPING UNITS AND OTHER SLEEPING UNITS OR COMMON AREAS (1206.2) ACCESS TO UNOCCUPIED SPACES (1208): PROVIDE MIN. 18" x 24" CRAWLSPACE ACCESS (1208.1) PROVIDE MIN. 20" x 30" ATTIC SPACE ACCESS (1208.2) USE AND OCCUPANCY: BUILDING HEIGHT AND AREA:TYPE OF CONSTRUCTION: OCCUPANCY GROUP(S): R-3 INCIDENTAL USES: *ALL INCIDENTAL USE AREAS PROVIDED WITH AUTOMATIC FIRE- EXTINGUISHING SYSTEMS - ROOMS w/ B0ILERS OVER 15 PSI AND 10 HORSEPOWER (SMOKE PARTITION) - STORAGE ROOM > 100 SF. (SMOKE PARTITION) - WASTE COLLECTION ROOM > 100 SF. (SMOKE PARTITION) OCCUPANCY SEPARATIONS (TABLE 508.4) SEPARATED BUILDING OCCUPANCIES TO CONFORM w/ SECTION 508.4 OCCUPANCY SEPARATION ARE REQUIRED - MAX. AREA PER MOST RESTRICTIVE USE OCCUPANCY LOADS/AREA (TABLE 1004.5): ALLOWABLE HEIGHTS / AREAS (TABLE 506.2): TYPE VB CONSTRUCTION GROUP R-3: UNLIMITED ACTUAL HEIGHT: 40'-0", 3 STORIES ACTUAL BUILDING AREAS: MAIN LEVEL: 3,550 SF SECOND LEVEL: 3,225 SF THIRD LEVEL: 3,605 SF TYPE VB - FULLY SPRINKLED-NFPA 13 (903.3.1.1) FIRE RESISTIVE REQUIREMENTS (TABLE 601): STRUCTURAL FRAME: 0 HR EXTERIOR BEARING WALL: 0 HR INTERIOR BEARING WALL: 1 HR INTERIOR NON-BEARING WALLS: 0 HR FLOOR CONSTRUCTION: 0 HR ROOF CONSTRUCTION: 1 HR EXTERIOR NON-BEARING WALLS BASED ON FIRE SEPARATION DISTANCE (TABLE 602): FSD ≥30': 0 HR 10' ≤FSD < 30': 0 HR 5' ≤FSD < 10': 1 HR FSD < 5': 1 HR 7'-6" MIN. CEILING HEIGHTS (1207.2) FLASHING REQUIRED TO PREVENT MOISTURE (1404.4) ROOF FLASHING REQUIRED (1503.2, 1507.5.7) NFPA 13 FIRE SPRINKLERS NOT REQUIRED THROUGHOUT (903.3.1.1) SMOKE ALARMS REQUIRED THROUGHOUT (907.2.10) PORTABLE FIRE EXTINGUISHERS REQUIRED THROUGHOUT (906.1) FIRE PROTECTION SYSTEMS: FIRE RATED CONSTRUCTION: MAX AREA OF EXTERIOR WALL OPENINGS (TABLE 705.8): OPENING PROTECTION: UNPROTECTED, SPRINKLERED FSD < 3': 0% 3' ≤FSD < 5': 15% 5' ≤FSD < 10': 25% 10' ≤FSD < 15': 45% 15' ≤FSD < 20': 75% 20' ≤FSD < 25': UNLIMITED 25' ≤FSD < 30': UNLIMITED FSD ≥30': UNLIMITED PARAPET (705.11): NOT REQUIRED - EXCEPTION 1: THE WALL IS NOT REQUIRED TO BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH TABLE 602 BECAUSE OF FIRE SEPARATION DISTANCE (<45%). SHAFT ENCLOSURE (713.4): CONNECTING 3 STORIES OR LESS: 1 HR CONNECTING 4 STORIES OR MORE: 2 HR FIRE PARTITION (708.4): 1 HR CONTINUOUS FROM THE TOP OF FOUNDATION TO UNDERSIDE OF THE ROOF SHEATHING OR ROOF CEILING ASSEMBLY WITH A FIRE RATING OF NOT LESS THAN THE FIRE RATING OF THE FIRE PARTITION HORIZONTAL ASSEMBLIES (711.2): N/A OPENING REQUIREMENTS (TABLE 716.5): 1 HR FIRE BARRIERS: 1 HR OPENING (SHAFTS, EXITS) 1 HR FIRE PARTITION: 45 MIN. OPENING (DEMISING WALLS, ELEV. LOBBY) 30 MIN FIRE PARTITIONS: 20 MIN OPENING (CORRIDORS) DESIGN AND CONSTRUCTION OF A 3 STORY RESIDENTIAL 6-PLEX. WOOD FRAME STRUCTURE WITH WOOD TRUSSES AND CONCRETE FOUNDATION. REQUIRED PLUMBING: 1 1 1 1 1 1 LEGEND: 1 HR FIRE RATED WALL / ASSEMBLY 2 HR FIRE RATED WALL / ASSEMBLY FIRE PROTECTION 1. 10 UNITS, 4 BEDROOMS EACH 2. 20 PARKING SPACES REQUIRED (2 PER UNIT) PROPOSED PARKING: 20 PARKING SPACES, 10 GARAGE SPACES 3. 150 SF OPEN SPACE REQUIRED PER UNIT = 1,500 SF (50% OF THE OPEN SPACE CAN BE PROVIDED BY USING BALCONIES IF THE BALCONIES HAVE A 6' MINIMUM INSIDE DIMENSION.) PROPOSED OPEN SPACE : 1,142 SF GROUND AND 480 SF OF BALCONY SPACE PARKING/ OPEN SPACE: ADA ACKNOWLEGDMENT: THIS PLAN SET ACKNOWLEDGES THE STATE AND LOCAL ACCESSIBLITY REQUIREMENTS ARCHITECTURE · PLANNING · DEVELOPMENT · INTERIORS1425 WEST MAIN ST. · SUITE A · BOZEMAN, MONTANA · 59715TELEPHONE: (406) 587-1204 · EMAIL: FHA@FHARCHITECTS.COM© 2022 FHA. It is unlawful to use any or all of these document without the expressed written consecnt of Faure Halvorsen Architects PC.DATE: 2022F A U R EH A L V O R S E N4/27/2023 9:31:27 AMG1.2DELPARK HOMESCATALYST by DELPARK HOMES3326 WARBLER WAY, BOZEMAN MT 59715GENERAL NOTES JOB NO: 22-919BUILDINGS 1&2DESCRIPTION:AREA: Not Placed GARAGE 0 SF 0 LIVING 0 SF 0 MAIN LEVEL LIVING 850 SF 0 SECOND LEVEL LIVING 874 SF 0 THIRD LEVEL LIVING 926 SF 0 TOTAL:2,650 SF 0 DESCRIPTION:PROVIDED:REQUIRED: 4 LAVATORY 16 MAIN LEVEL SHOWER STALL 4 WATER CLOSET 4 SECOND LEVEL WATER CLOSET 4 THIRD LEVEL 4 SHOWER STALL 4 WATER CLOSET 8