Loading...
HomeMy WebLinkAbout037 - E001 - ONE LINE, LEGEND, & SCHEDULES1.ALL CONDUIT SHALL BE SCHEDULE 40 PVC UL LISTED ELECTRICALCONDUIT. (PVC WATER PIPE IS NOT ACCEPTABLE). BURY MIN. 24" BELOWGRADE.2.ALL WORK SHALL BE IN CONFORMANCE WITH THE NEC.3.MINIMUM CONDUIT SIZE SHALL BE 1".4.CONDUIT AND CONDUCTOR SIZE/QTY CALLED OUT IN THE HOME RUNSHALL BE CARRIED THROUGHOUT THE ENTIRE CIRCUIT.5.ALL CONDUCTORS SHALL BE COPPER.6.ELECTRICAL PLANS ARE DIAGRAMMATIC. SEE CIVIL PLANS FOR EXACTCONDUIT ROUTING. PROVIDE FLUSH IN GRADE PULL BOXES WHEREREQUIRED. COORDINATE PULL BOX LOCATION WITH LANDSCAPEARCHITECT.GENERAL NOTESLEGENDSHEET WORK NOTESSURFACE MOUNTED WALL PACK/SCONCEBOLLARD LIGHTRECESSED CAN LIGHTPOLE LIGHTBRANCH CIRCUIT CONDUIT/WIREHOME RUN TO PANEL MP (1,3,5 = CIRCUIT NUMBER)-1,3,5LUMINAIRE SCHEDULETYPEDESCRIPTIONMANUF.CATALOG NUMBERHEIGHTLAMPCRIKELVINNO.VOLTAGEWLUMENSDIMMINGFINISHNOTESB1PATHWAY BOLLARDSTRUCTURALBL-S-24-L30-SO-4-CX-PX/XX-UNV-GFCI-STD2'LED9030003120-277V117250-10VN/A 1C1RECESSED SEATING AND ENTRANCE LIGHTLITHONIA LIGHTINGWF6-LED-30K40K50K-MVOLT-90CRI-XX12'LED9030007120-277V1410900-10VN/A 1P1PARKING LOT POLE LIGHTLITHONIA LIGHTINGDSX1-LED-P1-30K-70CRI-BLC3-MVOLT-RPA-DDBXD16'LED7030003120-277V515300N/ADARK BRONZEP2POOL POLE LIGHTLITHONIA LIGHTINGDSX1-LED-P2-30K-70CRI-BLC3-MVOLT-RPA-DDBXD10'LED7030003120-277V686814N/ADARK BRONZEP3POOL POLE LIGHT - WIDE DISTRIBUTIONLITHONIA LIGHTINGDSX1-LED-P3-30K-70CRI-T5LG-MVOLT-RPA-DDBXD10'LED7030001120-277V10213830N/ADARK BRONZES1DECORATIVE WALL SCONCESEAGULL LIGHTING8531701-128'BULBN/AN/A10120V65N/AN/ABRONZE 2W1POOL WALL PACKRABSLIM17FA15ADJ11' 6"LED7030005120V1417610-10VBRONZEW2DECORATIVE POOL WALL PACKLITHONIA LIGHTINGWPX2-LED-30K-MVOLT-DDBXD14LED7030002120-277V476000N/ADARK BRONZENOTES:1.FINISHES TO BE SELECTED BY ARCHITECT.2.FURNISH WITH MEDIUM BR30 65W MAX. 120V BULB, NOT INCLUDED WITH FIXTURE.SLOPE TO DRAINNO. 4 HORIZONTALBARS @ 12" O.C.4 NO. 4 VERTICALBARSSEE SITE PLANFOR BRANCHCIRCUIT WIRINGSUBGRADE TO 95%PROCTOR DENSITYGROUT AFTER LEVELING1/2" X12" ANCHOR BOLT MIN 1 1/2"ABOVE TOP OF CONCRETE BUTLESS THAN 2 1/2" TYP. (3) PLACESMOUNTING BASE1" CONDUIT24"10"POLE B A S E DIAM E T E R PROJECT ANCHOR BOLTS ABOVE TOP OFBASE. PROVIDE DOUBLE NUTS FORLEVELING UNIT (ONE ABOVE AND ONEBELOW BASE FLANGE). GROUT VOIDBETWEEN BASE FLANGE AND TOP OFCONCRETE. HAND FINISH. TEMPLATE TOBE FURNISHED BY POLE MANUFACTURER.BASE COVERREINFORCEDCONCRETE BASE, BYELECTRICALCONTRACTORSEE SITE PLANFOR BRANCHCIRCUIT WIRINGFINISHEDGRADE LINEANCHOR BOLTS TOBE FURNISHED BYPOLE MANUFACTURER3 -#3 TIES ATTOP OF FORMSTUB SEPARATE 1" CONDUITFOR SECURITY. EXTEND TOPULLBOX. PROVIDE STUB OUTWHEN NO CAMERA EXISTS.1 1/2" MIN. FINISH GROUT45 DEGREE CHAMFERBUSH CONDUIT ENDSHAND HOLEPROVIDE FUSE(S) IN CIRCUIT TOBALLAST. FUSE SIZE AS REQUIREDBY LUMINAIRE MANUFACTURER#3 TIES1'-7" LAPVERTICAL BARS3"CLRVERTICAL BARS#3 TIES @12"RESTRAINED AT BASERIGID SURFACE SURROUNDS POLE AT GROUNDLINE3" MIN "A"2"1 1/2" 18" MIN 30" "C"5#5 TIESPOLEHEIGHT20' OR LESS30' OR LESS40' OR LESSPOLE BASEDIAMETERVERTICALBARSDEPTH BELOW GRADERESTRAINEDDEPTH BELOW GRADEUNRESTRAINED"A""B""C""C1""20"5-#54'-6"6'-0""24"6-#65'-6"7'-0""30"8-#66'-6"9'-0"(MIN. 3" LARGER THAN OUTER MOST PORTION OF BASE COVER)NOTE: PROVIDE 8' OF #6 AWG BARE COPPER WIRE WITHIN POLE BASEAND TIE TO VERTICAL/HORIZONTAL BARS AND BOND TO POLE ASREQUIRED.06.29.17 11:09 PM | L:\SRXBZN_LIGHT\BIMCAD\Elec\SRX_CLUB E001 - SCHEDULES, LEGEND, ONE LINE.dwgE001ONE LINE, LEGEND,& SCHEDULESEGOLF-BRONEC1E001BOLLARD CONCRETE FOUNDATION DETAIL NTS5E001RESTRAINED POLE CONCRETE FOUNDATION DETAIL NTSDRAWN BY |REVISIONS©| ALL RIGHTS RESERVEDCHECKED BY |®PROJECT #|SOUTH RANGE CROSSING CLUBHOUSE SRXBZN_LIGHT BOZEMAN, MT 59715CONSTRUCTIONDOCUMENTS07.14.20232020SRXBZN_LIGHT