Loading...
HomeMy WebLinkAbout026 C030 WATER DETAILSMJ GLANDMJ VALVEMJ GLANDD.I.PIPED.I.PIPEMJ TEED.I. PIPED.I. PIPEMJ GLANDCONCRETE THRUSTBLOCK (TYP)UNDISTURBEDEARTH (TYP)MJ GLANDMJ VALVED.I. PIPE3/4" MIN. CORROSION RESISTANT ALL THREADRESTRAINING ROD, CONFORMING TO ASTM A242-81,INSTALLED IN HALF THE AVAILABLE MECHANICAL JOINTBOLT HOLES (TYP) WHERE NECESSARY, CLAMPINGLUGS (ROMAC "DUCTILE LUG" OR EQUAL) DESIGNEDTO FIT DUCTILE IRON (D.I.) PIPE, AND CONFORMINGTO ASTM 536-80 MAY BE USED IN CONJUNCTIONWITH THE RESTRAINING RODS."C""B""A"6""C"REBARANCHORCONCRETEANCHORSNOTE: COAT ROADS WITH "KOPPERS" BITUMASTIC NO. 50 COATING OR EQUAL.THRUST BLOCK DIMENSIONSANCHORROD SIZEVALVESIZE100 PSIABC150 PSIABC200 PSIABC250 PSIABC300 PSIABC1/2"6" & 8"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-7"1/2"10"2'-0"2'-0"2'-0"2'-6"2'-6"2'-0"2'-9"2'-6"2'-6"3'-0"3'-0"3'-0"3'-7"3'-0"3'-0"1/2"12"2'-3"2'-0"2'-0"3'-0"3'-0"2'-8"3'-5"3'-0"3'-0"4'-3"3'-0"3'-0"5'-1"3'-0"3'-0"1"14"2'-3"2'-0"2'-0"3'-5"3'-0"3'-0"4'-6"3'-0"3'-0"4'-0"4'-0"4'-0"4'-9"4'-0"4'-0"1-1/8"16"3'-0"3'-0"3'-0"4'-4"3'-0"3'-0"4'-1"4'-0"4'-0"5'-1"4'-0"4'-0"6'-1"4'-0"4'-0"1-1/4"18"3'-8"3'-0"3'-0"5'-5"3'-0"3'-0"5'-1"4'-0"4'-0"6'-4"4'-0"4'-0"5'-9"5'-0"5'-0"1-3/8"24"4'-4"4'-0"4'-0"6'-5"4'-0"4'-0"6'-6"5'-0"5'-0"6'-5"6'-0"6'-0"7'-8"6'-0"6'-0"NOTE: PRESSURES SHOWN ABOVE ARE MAXIMUM WORKING PRESSURES IN THE SYSTEM.THRUST BLOCKING AND ANCHORS ARE REQUIRED ON ALL 6" VALVES AND LARGER UNLESS SPECIFIED BY THE ENGINEER.MEGA-LUG OR APPROVED EQUAL JOINT RESTRAINTS MAY BE USED IN LIEU OF CONCRETE THRUST BLOCKS.THRUST BLOCKS NOT REQUIRED ON TAPPING VALVES.11METER &STRAINERSPOOLSPOOLBACKFLOWPREVENTIONASSEMBLYPRESSUREREDUCINGVALVENO FITTINGS BETWEENMETER AND BACKFLOWPREVENTION ASSEMBLY2' MIN CLEARTO OTHERMECHANICAL LINESINSTALLVALVEWITH STEMPARALLELTO WALLOS&YVALVE90°BENDPLAN VIEW2234NOTES:1.STANDPIPE FLANGE TO BE ONE FOOT (1') MINIMUM TO INTERIOR WALL AND TWO FOOT (2')MAXIMUM TO EXTERIOR WALL.2.A MINIMUM OF FOUR (4) PIPE DIAMETERS OF STRAIGHT RUN PIPE IS REQUIRED UPSTREAM ANDDOWNSTREAM OF THE METER / STRAINER ASSEMBLY.3.METER MUST BE INSTALLED HORIZONTAL. STRAINER IS REQUIRED.4.BACKFLOW PREVENTION ASSEMBLIES MUST BE UL OR FM LISTED AND APPROVED BY USCFCCCHR.5.ALL PIPE SHALL BE DUCTILE IRON UP TO PRESSURE REDUCING VALVE.NOT TO SCALETYPICAL VALVE / TEE RESTRAINT DETAIL02660-10NOT TO SCALETHRUST BLOCKING FOR WATER MAIN VALVES DETAIL02660-3NOT TO SCALETYPICAL RISER CONFIGURATION02660-12ANOT FOR CONSTRUCTION03/2021VERIFY SCALE!THESE PRINTS MAY BE REDUCED.LINE BELOW MEASURES ONE INCHON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY!2022COPYRIGHT © MORRISON-MAIERLE, INC.,SHEET NUMBERPROJECT NUMBERDRAWING NUMBERDATEDESCRIPTIONNO.BYN:\4192\025 - THE BOULDERS SITE DEVELOPMENT\ACAD\SHEETS\PHASE 2\4192025 C030 WATER DETAILS.DWG PLOTTED BY:CELINE SAUCIER ON Apr/06/2022REVISIONSDRAWN BY:DSGN. BY:APPR. BY:DATE:Q.C. REVIEWDATE:BY:2880 Technology Blvd WestBozeman, MT 59718406.587.0721www.m-m.netengineers surveyors planners scientistsMorrisonMaierleBOULDERS CREEK APARTMENTS PHASE 24192.025MONTANAWATER DETAILS4C030 CMSCMSMEE03/2021 BOZEMANNOT FOR CONSTRUCTION03/2021Know what'sbelow.before you dig.CallRKnow what'sbelow.before you dig.CallR