Loading...
HomeMy WebLinkAbout030 LS3.1 Lantern Park S. SideCONTRACTOR TO VERIFY EXACT LOCATION OF P.O.C. AND WELL- SEE DETAIL LS6.1/9 IRRIGATION, MAINLINE, VALVES, ETC. SHOWN HERE FOR DRAWING CLARITY. LOCATE IN LAWN AREA, TYP. 3 4"34"34" 34" 114" 114" 34"1" 1" 34"34" 1" 114" 112" 34" 112" 2" 2" 34" 114" 3 4" 112" 34" 34" 2" 112" 34" 34" 1" 114" 114" 112" 2" 2" 'A' 34" 3 4" 1" 114" 34" 112" 112" 2" 34" 114" 34" 114" 114" 2"114" 1" 34" 1" 114" 112" 3 4" 34" 114" 114" 112" 34" 34" 112" 114" 114" 3 4" 34" 34" 34" ALLOW THESE HEADS TO SPRAY NATIVE GRASSES. ALLOW THESE HEADS TO SPRAY NATIVE GRASSES. 1" 114" 3 4" 34" 12" POP-UP. PLACE 1.5' AWAY FROM EDGING TO THE EAST. SEE 2131 GRAF PLANS FOR ADJACENT IRRIGATION. 'B' SEE NEXUS POINT PLANS FOR ADJACENT IRRIGATION. 3 4" 3 4" 34" 34" 34" 34" 1" 34" 112" 3 4" 34" 1" 1" 114" 112" 34" 1" 114" 34" 114" 34" 1" 34" 34" 34" 34" 34" 34" 114" 34" 34"34"1" 34"34"114" 34"114" 34" 112" 112" 112" 1" 34" 3 4" 34" 112" 34" 3 4" 34" 2" 114"114" 34" 1" 114" 3 4" 34" 34"114" 34" 34" 3 4" 34" 34" 3 4" 114" 3 4" 34" 112" 34" 114"34" 112"34" 112" 112" 34" 34"1" 114" 114" 34" 1" 34"1" 114" 34" 34"114" 112" 112" 34" 34" 114" 34" 114" 114" 34"1" 34" 34" 34" 112" 112" 3 4" 1" 34" 1" 34" 34" 112" 43" 43" "1 2" "2 CONTRACTOR TO VERIFY EXACT LOCATION OF P.O.C. AND WELL- SEE DETAIL LS6.1/9 "1 43" 411" 43" "1 43 " 43" 43" 43" 411" 43" "1 411" 211" 211" 211" 411" 43" 43" 211" 43" 43" 411" 43" "1 411" 211" 211" 211" 211" 411" 43" "1 43" 411" 43"411" 43" 411" 211" 211" 211" 411" 43" 43" 43" 411" 411" 211" 43" "1 43" 411" 43" 211" 211"211" 43" 43" 43" 211" 43" 211" 43"43" "1 43" "1 411" 43" 411" 211" 43" "1 43" 411" "1 "1 43" IRRIGATION NOTES 1.ALL WORK SHALL BE IN ACCORDANCE WITH APPLICABLE CITY AND/OR COUNTY CODES. THE CONTRACTOR SHALL APPLY AND PAY FOR ALL NECESSARY PERMITS. 2.CONTRACTOR SHALL HAVE ALL UTILITIES BLUE STAKED BEFORE DIGGING. ANY DAMAGE TO THE UTILITIES SHALL BE REPAIRED AT THE EXPENSE OF CONTRACTOR WITH NO EXTRA COST TO THE OWNER. 3.PROVIDE AN AS-BUILT, REPRODUCIBLE DRAWING TO OWNER SHOWING ALL DRAINS, HEADS, VALVES, AND PIPES. PROVIDE INSTRUCTIONS TO MAINTENANCE PERSONNEL FOR WINTERIZATION. SPRINKLER SYSTEM TO BE BLOWN OUT WITH AN AIR COMPRESSOR EACH FALL. 4.CONTRACTOR SHALL ONLY USE COMMERCIAL GRADE PRODUCTS AND IS RESPONSIBLE FOR ENSURING ACCURATE COUNTS AND QUANTITIES OF ALL IRRIGATION MATERIALS FOR BIDDING AND INSTALLATION PURPOSES. 5.CONTRACTOR SHALL BUILD IRRIGATION SYSTEM WITH HEAD TO HEAD COVERAGE AT A MINIMUM FOR ALL LAWN AREAS. ADJUST FOR CLOSER SPACING IF WINDS ARE PREVALENT. VAN AND/OR U-SERIES NOZZLES SHALL BE USED WHERE NECESSARY TO PROVIDED HEAD TO HEAD COVERAGE AND/OR TO MINIMIZE OVER SPRAY ONTO STREETS, SIDEWALKS AND/OR BUILDINGS. 6.LANDSCAPE CONTRACTOR (L.C.) SHALL PROVIDE AND INSTALL SLEEVES FOR ALL PIPES AND WIRES UNDER PAVEMENT AND SIDEWALKS. SLEEVES SHALL BE 2 SIZES LARGER THAN PIPE INSIDE. ALL WIRE SHALL BE IN SEPARATE SLEEVES (NOT SHOWN). ALL CONTROL WIRE SHALL BE INSTALLED IN CLASS 200 PIPE. PLACE JUNCTION BOXES WHERE NECESSARY TO MINIMIZE LONG RUNS OR AT DIRECTIONAL CHANGES AS NECESSARY. 7.ALL SLEEVES INSTALLED SHALL BE DUCT TAPED TO PREVENT DIRT OR OTHER DEBRIS ENTERING PIPE. ALL SLEEVES SHALL BE IDENTIFIED BY WOOD OR PVC STAKES AND BE SPRAY PAINTED WITH MARKING PAINT. REMOVE STAKES ONCE IRRIGATION SYSTEM IS COMPLETE. 8.MAIN LINE SHALL BE 2". LATERAL LINES SHALL BE NO SMALLER THAN 3/4" UNLESS NOTED ON PLAN. PIPES SHALL CARRY NO MORE THAN THE FOLLOWING: 1/2" MAX. 4 GPM, 3/4" PIPE MAX. 8GPM, 1" PIPE MAX. 13GPM, 1-1/4" PIPE MAX. 23GPM, 1-1/2" PIPE MAX. 30GPM, 2" PIPE MAX. 50 GPM. ADJUST LOCATION OF MAINLINE AND LATERAL LINES AS NECESSARY IN ORDER TO AVOID PLACING BOULDERS, TREES AND SHRUBS DIRECTLY OVER MAINLINE AND LATERAL LINES. 9.MAIN LINES SHALL BE 18" DEEP MIN. AND LATERAL LINES 12" DEEP MIN. NO ROCK GREATER THAN 3/4" DIAMETER SHALL BE ALLOWED IN TRENCHES. 10.PLACE PIPES, VALVE BOXES AND ALL OTHER SPRINKLER CONSTRUCTION IN LANDSCAPE AREAS. ALL PIPES SHALL BE ON PROPERTY OF OWNER. MODIFY LOCATION OF VALVE BOXES AS NECESSARY IN ORDER TO AVOID TREES AND SHRUBS PER PLANTING PLAN. DO NOT LOCATE VALVE BOXES IN LAWN AREAS IF POSSIBLE. 11.AT OWNERS REQUEST AND FOR AN ADDITIONAL FEE, LANDSCAPE ARCHITECT SHALL VISUALLY INSPECT ALL TRENCHES PRIOR TO BACKFILLING. CONTRACTOR SHALL GIVE LANDSCAPE ARCHITECT MIN. 72 HR. NOTICE BEFORE INSPECTION IS TO BE MADE. CONTRACTOR SHALL PRESSURE TEST MAINLINE FOR LEAKS PRIOR TO BACKFILLING. 12.ALL SPRINKLERS SHALL BE ADJUSTED ON-SITE AS NECESSARY TO AVOID ANY WATER SPRAYING ONTO STREETS, SIDEWALKS AND/OR BUILDINGS. 13.ACTUAL INSTALLATION OF IRRIGATION SYSTEM MAY VARY SOMEWHAT FROM PLANS. CONTRACTOR IS RESPONSIBLE TO MAKE NECESSARY ADJUSTMENTS TO ENSURE PROPER COVERAGE OF ALL LANDSCAPED AREAS. 14.LANDSCAPE CONTRACTOR SHALL MATCH PRECIPITATION RATES AS MUCH AS POSSIBLE FOR ALL LANDSCAPED AREAS. 15.INSTALL ALL HEADS 2" AWAY FROM ALL WALKS AND WALLS. VALVE BOXES SHALL BE INSTALLED SQUARED TO AND 6" MIN. AWAY FROM WALKS AND WALLS. 16.DRIP LINES SHALL BE FLEXIBLE AR PVC TUBING BY GPH. FOR DRIP AREAS REQUIRING 0-4 GPM USE 1/2" TUBING. FOR DRIP AREAS REQUIRING 4-8GPM USE 3/4" TUBING AND FOR DRIP AREAS REQUIRING 8-13 GPM USE 1" TUBING. CONTRACTOR TO VERIFY PLANT QUANTITIES ON EACH DRIP LINE AND SIZE PIPE ACCORDINGLY. 17.CONTRACTOR TO INSTALL NETAFIM ON-SURFACE DRIP LINE FOR TREES AS SHOWN IN THE DETAILS. MODIFY DRIP ZONES AS NECESSARY TO PROVIDE ADEQUATE COVERAGE TO ALL LANDSCAPED AREAS. 18.POWER TO CONTROLLER AND WELL TO BE PROVIDED BY ELECTRICAL CONTRACTOR PER BOZEMAN CITY STANDARDS. OWNER TO SPECIFY EXACT LOCATION OF CONTROLLER. CONTROLLER TO BE MOUNTED IN WEATHERPROOF LOCKING WALL MOUNTED OR PEDESTAL CABINET PER MANUFACTURERS INSTRUCTIONS. LANDSCAPE CONTRACTOR SHALL ENSURE THE CONTROLLER IS GROUNDED PER LOCAL CODE AND PER MANUFACTURER SPEC. 19.IF THE STATIC PRESSURE AT THE POINT OF CONNECTION EXCEEDS 110 PSI, INSTALL A BRASS PRESSURE REDUCER PER MANUFACTURER SPECS AND ADJUST PRESSURE AS REQUIRED FOR NORMAL OPERATION OF THE IRRIGATION SYSTEM. 20.THE IRRIGATION SYSTEM SHALL BE CONNECTED TO A WELL ON-SITE. THE MAX. FLOW RATE FOR THE WELL SHALL BE 35 GPM. THE WELL PUMP SHALL BE CAPABLE OF PUMPING 35 GPM AT 70-75 PSI AND WILL NEED TO MAINTAIN A MIN OF 45PSI AT FURTHEST ROTOR HEAD FROM THE POINT OF CONNECTION. IF THE PRESSURE AT FURTHEST ROTOR HEAD FALLS BELOW 45PSI, A BOOSTER PUMP OR LARGER HORSE POWER WELL PUMP WILL BE NEEDED. IF A BACKFLOW PREVENTOR IS REQUIRED BY BOZEMAN CITY, THEN THE PRESSURE COMING OUT OF THE WELL HEAD WILL NEED TO BE AT LEAST 85-90 PSI. THE CONTRACTOR SHALL CONFIRM WITH BOZEMAN CITY IF A BACKFLOW PREVENTOR IS REQUIRED OR NOT (PRIOR TO BEGINNING CONSTRUCTION). WELL HEAD AND EQUIPMENT SHALL BE PLACED INSIDE AN APPROPRIATE SIZED INSULATED ENCLOSURE. 21.THE CONTRACTOR SHALL TEST THE WATER AT THE WELL TO DETERMINE IF A FILTER IS REQUIRED OR NOT FOR THE IRRIGATION SYSTEM TO OPERATE AS DESIGNED. IF A FILTER IS NEEDED, THE CONTRACTOR SHALL PROVIDE A COST TO THE OWNER TO PURCHASE AND INSTALL A FILTER THAT IS CAPABLE OF FILTERING THE WATER PER RAINBIRD AND NETAFIM SPECS FOR THE SPECIFIED EQUIPMENT CALLED OUT IN THE PLANS. 22.ALL HEADS SHALL BE WATER CONSERVING WITH PRESSURE REGULATION. 23.INSTALL THE PRS-D OPTION FOR SPRAY VALVES IF THE STATIC PRESSURE AT SPRAY HEADS EXCEEDS 70 PSI. INSTALL PRS-D FOR ROTOR ZONES IF THE STATIC PRESSURE EXCEEDS 75 PSI. SYMBOL MANUFACTURER-MODEL NUMBER PAT. RD. PSI VALVE ID TAG ZONEVALVE PRESSUREGPM SIZE GPM Q T H TT TQ F DETAILS REMARKSDRIP GPH IRRIGATION LEGEND ------------2.030F DRIP CONTROL ZONE KIT: RAINBIRD XCZ-100-PRB COM NOT SHOWN NOT SHOWN LATERAL LINE: PVC SCH. 40 (SIZE PER PLAN) 'A' RAIN BIRD PESB-PRSD AUTOMATIC CONTROL VALVE (SIZE AS NOTED ON PLAN). INSTALL PRS-D OPTION IF REQ. PER SPECS/DETAILS. -- SLEEVE (SIZE TO BE A MIN. OF TWICE THE DIAMETER OF THE MAIN, LATERAL) ROUTE WITH MAINLINE 1" RAINBIRD QUICK COUPLER VALVE, MODEL #44LRC. FOR IRRIGATION SYSTEM BLOWOUT. COORDINATE WITH ALL TRADES 1.00 1.38 1.98 ----3.82 --25'45 1.40 1.85 2.96 ----5.78 --30'45 Q,T,H,F Q,T,H,F 1.92 2.46 3.81 --------35'45 Q,T,H,F ADJUST ARC AS NEEDED WELL WITH 2" POINT OF CONNECTION. INSTALL WELL HEAD ABOVE GRADE AND SLOPE GRADE AWAY FROM WELL PER CODE. WIRE CHASE, SIZE TO BE TWICE THE DIAMETER OF THE WIRE BUNDLE WITHIN, 1" DIA. WC IS THE MINIMUM SIZED ALLOWED.COORDINATE WITH ALL TRADESNOT SHOWN ADJUST ARC AS NEEDED ADJUST ARC AS NEEDED Q,H,F,HE-V 1.3012'.5930 2.37 14 GAUGE SINGLE STRAND SOLID COPPER CONTROL WIRE. INCLUDE 2 EXTRA HOME RUN WIRES FOR FUTURE USE. GPH INC. GPSCV2M DRIP EMITTER ADJUST ARC AS NEEDED-- INSTALL PER LOCAL CODE 10 1 912,13,17 2,12,13 9,14,15 8 14,15 14,15 16 SEE IRRIGATION DETAILS4,5 COORDINATE EXACT LOCATION WITH OWNER. FLUSH VALVE: 1/2" PVC BALL VALVE. INSTALL AT END OF ALL DRIP LINES IN 10" ROUND VALVE BOX REFERENCE DETAILS3 DRIP LATERAL: PVC SCH 40, OR STICKY-STRIP PVC HOSE BY GPH. CONTRACTOR SHALL SIZE PIPE PER DETAILS AND SPECS. 2" SCH. 40 PVC MAINLINE UNLESS OTHERWISE NOTED. ------------5.030FNOT SHOWN --RAINBIRD PC-05 EMITTER WITH DIFFUSER CAP SEE IRRIGATION DETAILS5,6 SEE IRRIGATION DETAILS 14,15 SEE IRRIGATION DETAILS SEE IRRIGATION DETAILS5,6,7,14,15 SEE IRRIGATION DETAILS CONTROLLER: RAINBIRD ESP-LXMEF (SIZE CONTROLLERS AS REQUIRED). LOCATION T.B.D. BY OWNER. INSTALL RAINBIRD RAIN SENSOR. INSTALL PER BOZEMAN CITY STANDARDS. Q,H,F,HE-V VAN 1.85.93 3.70 2.661.33 5.32 -- ---- -- ---- -- -- -- -- -- 30 30 15' 18' ADJUST ARC AS NEEDED ADJUST ARC AS NEEDED NOT SHOWN DRIPLINE: NETAFIM TLCV26-18 .26/18"F --30 ------------SEE IRRIGATION DETAILS7,18 11 11 11 10 10 ROOT WATERING SYSTEM SEE IRRIGATION DETAILS6 WATER WISE PERENNIALS/GRASSES 1 GPSTCV2M (1GPH) NON WATERWISE PERENNIALS/GRASSES 1 GPSTCV2M (2GPH) ALL WATER WISE SHRUBS 2 GPSTCV2M (1GPH) ALL NON WATER WISE SHRUBS 2 GPSTCV2M (2GPH) TREES IN PLANTERS 3 PC-05 (5GPH) NOTES: 1.EMITTERS LISTED ARE AVAILABLE FROM GPH AND RAINBIRD. 2.INSTALL NETAFIM TLCV IN ADDITION TO PC-05 EMITTERS PER DETAILS ON SHEET LS6.1/7. 3.INSTALL PC-DIFFUSER CAP ON ALL PC-05 EMITTERS. 4.CONTRACTOR SHALL ADJUST QUANTITY OF EMITTERS AND/OR RUNTIMES OF DRIP ZONES AS NECESSARY DURING THE PLANT ESTABLISHMENT PERIOD. CONTRACTOR SHALL HAND WATER PLANTS AS NECESSARY DURING ESTABLISHMENT PERIOD IN ORDER TO ENSURE THAT OVER OR UNDER WATERING DOES NOT OCCUR. 4.INSTALL PC-05 EMITTER IN RAINBIRD ROOT WATERING CANISTER. INSTALL (1) RWS PER EACH TREE LOCATED IN LAWN AREAS. PLANT TYPE EMITTER QTY EMITTER TYPE DRIP EMITTER LEGENDRAIN BIRD 1804-PRS-NP POP-UP SPRAY 12 SERIES Q,H,F,HE-V 1.3012'.5930 2.37 -- RAIN BIRD 1804-PRS-NP POP-UP SPRAY 15 SERIES RAIN BIRD 1804-PRS-NP POP-UP SPRAY 18 SERIES VAN 1.85.93 3.70 2.661.33 5.32 -- ---- -- ---- -- -- -- -- -- 30 30 15' 18' RAIN BIRD 1804-PRS-NP POP-UP SPRAY 8 SERIES Q,H,F,HE-V .528'.2630 1.04 --RAIN BIRD 1804-PRS-NP POP-UP SPRAY 10 SERIES Q,H,F,HE-V 1.85.93 3.70 ---- ---- -- -- --3010'11 11 ADJUST ARC AS NEEDED ADJUST ARC AS NEEDED RAIN BIRD R-VAN18 1804-P45-NP ROTARY SERIES 45°-270°1.01.50 ----1.51----4513'-18'11 RAIN BIRD 5004-PL-PC,FC-MPR-NP-SS WITH 30 SERIES NOZZLES RAIN BIRD 5004-PL-PC,FC-MPR-NP-SS WITH 25 SERIES NOZZLES RAIN BIRD 5004-PL-PC,FC-MPR-NP-SS WITH 35 SERIES NOZZLES RAIN BIRD R-VAN14 1804-P45-NP ROTARY SERIES* *4" POP-UP UNLESS OTHERWISE NOTED. SEE ZONE A22. RAIN BIRD 1804-PRS-NP POP-UP SPRAY 15 STRIP SERIES 45°-270°.63.32 1.27 --.94----458'-14' LCS,RCS,SST 30 11 11 ADJUST ARC AS NEEDED ADJUST ARC AS NEEDED ADJUST ARC AS NEEDED 'B' PLANT TYPE # GALLONS # OF PLANTS TOTAL GALLON/YEAR WATER CONSUMPTION SOUTH (May-Oct.) PERENNIAL/GRASS WATER WISE PERENNIAL/GRASS NON-WATER WISE SHRUB WATER WISE SHRUB NON-WATER WISE ALL TREES LAWN AREA/NATIVE AREA TOTAL PLANTING : TOTAL WITH LAWN: 1.25 GAL/WEEK 2.5 GAL/WEEK 2.5 GAL/WEEK 5 GAL/WEEK 20 GAL/WEEK 22.5 IN/YEAR 36 15 22 6 36 1,080 900 1,320 720 17,280 21,300 64,710 SF 1,289,578 1,310,878 SCALE: 0 1"=20'-0" ON 24X36 SHEET 20'20'40'60'THIS DRAWING IS THE INTELLECTUAL PROPERTY OF IN-SITE DESIGN GROUP. DO NOT COPY OR REPRODUCE IN ANY WAY WITHOUT THE EXPRESS WRITTEN PERMISSION OF IN-SITE DESIGN GROUP. COPYRIGHT© 2006architects@in-sitedesigngroup.com17 North 470 West American Fork, Utah 84003801.756.5043 www.in-sitedesigngroup.comCITY SUBMITTALTSETAOTNFOMCETIHCRA EPACSDNALDESNECILT Cory B.Whiting# 10629ANA08-21-20BOZEMAN - MONTANABLACKRIDGE COMPANIES LLCLANTERN PARK S. SIDEPLANIRRIGATIONLS 3.1 19-114 08-21-20 05-14-20 TGM JES NORTH PARK AREA BY OTHERS NORTH PARK AREA BY OTHERS 1 1 1