Loading...
HomeMy WebLinkAbout003-C-2 UTILITY4 W4 W4 WSSSSSSSSSSSS SS SS S S SS SSSSSSSSWSWSWS WS WSWSWSWSWS4 W4 W4 W4 WWSWSWSWSWSWSWSWSEEEEEEE E E SDSDSDSDSDSDSDSDSDSD SD SD 4 W 4 W4 W4 WFDC FDC 4 WWSWSWSWSWSWSWSEEEEEEEEFDCFDCFDCFDCG GGGGGGGGGGGGGGGGGGGGGGGGGGG GGGGGT TTTTTTTTTTTTTTTTTTTTTTTTT TTTTTE E E E E E E E E E E EEEEEEEEEEEEEEEE EEEEETTTTTTTTTTTTTTEET24 SS 24 SS 24 SS 24 SS 24 SS 24 SS 24 SS 24 SS 24 SS 24 SS 24 SS 24 SS 24 SS 24 SS 24 SS 24 SS 24 SS 24 SS 24 SS 24 SS8 SS8 SS8 SS8 SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS 8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 WWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS 8 W12 SD 12 SDWSEEEEESSSSSSWSWSWSWSWSGGGGGTTTTTNGRAPHIC SCALE1 inch = ft.0( IN FEET )10202020H:\1086\019\ACAD\SHEETS\C-2 UTILITY PLAN.dwg Plot Date: 6/1/2023 7:35 AMEXISTINGDUPLEXEXISTINGFOURPLEXEXISTINGTRIPLEXEXISTINGTRIPLEXEXISTINGFOURPLEXCATALYST STREETNORTH 27TH AVENUE287.32' S89°46'08"E PROPERY BOUNDARY368.22' S00°13'52"W287.47' S89°44'49"W PROPERTY BOUNDARY186.71' N00°13'45"E 184.14' N00°16'38"E 5' SIDE YARD SETBACK10' FRONT YARD SETBACK10' FRONT YARD SETBACK EXISTING HYDRANTEXISTING SIDEWALKEXISTING SIDEWALK 8" D.I.P. WATER MAIN8" PVC SEWER MAIN12" D.I.P. WATER MAIN 24" PVC SEWER MAIN EXISTING HYDRANTINSTALL 12' OF NEW D.I.P.AND MOVE HYDRANTEXISTINGHYDRANTEXISTING 4" PVC SEWERSERVICES(4)EXISTING 1.5" COPPERWATER SERVICES, TO BECAPPED AT MAIN(4)EXISTING 1.5" COPPERWATER SERVICES TO BECAPPED AT THE MAINEXISTING 4" PVCSEWER SERVICESINSTALL 36' OF 4" D.I.P. &OS&Y VALVE8" D.I.P. WATER MAIN MIXED BLOCK FRONTAGEMIXED BLOCK FRONTAGE CONNECT TO EXISTING 4"SDR 26 PVC SEWER STUB& EXTEND 20' AT 2.0%BUILD ING 1BUI LD ING 2BUI LD ING 3BUI LD ING 4 SIGHT TRIANGLESIGHT TRIANGLESI G H T T R I A N G L EPROPOSED TRASHENCLOSUREINSTALL 192' OF SDR 26PVC STORM PIPE, S=1.0%HYDRODYNAMIC SEPARATORCDS2015-4-CRIM=4668.80INV IN & OUT=4664.70EXISTING GAS,POWER ANDCOMMUNICATIONSH:\1086\019\ACAD\SHEETS\C-2 UTILITY PLAN.dwg Plot Date: 6/1/2023 7:35 AM190 NORTHSTAR LANE, BOZEMAN, MT 59718 HEADWATERSMT.NET 406-581-5730 PROPOSED BURIEDELECTRICAL TOBUILDINGS 1 & 2.EXISTINGBUILDINGEXISTINGBUILDINGEXISTINGBUILDINGEXISTINGBUILDINGEXISTINGBUILDINGEXISTING EDGEASPHALTPROPOSED COVEREDPARKING STRUCTUREEXISTING WELLTO BE UTILIZED FORIRRIGATIONLEGENDUNDERGROUND ELECTRICSEWER PIPEWATER SERVICE LINEEASEMENT OR SETBACK AS LABELEDUNDERGROUND GAS LINEUNDERGROUND COMMUNICATION LINEEXISTING CONTOURS 0.5' INTERVAL4" IRRIGATION CONDUITPROPOSED SIDEWALKEXISTING CURBCONNECT TO EXISTING 4"SDR 26 PVC SEWER STUB& EXTEND 47' AT 20.0%INSTALL 42' OF 2" COPPERWATER SERVICE & 2" METER9'X5' MECHANICAL/RISER ROOMPROPERTY BOUNDARY PROPERTY BOUNDARYSNOWSTORAGESNOW STORAGELIVE TAP EXISTING 8" D.I.P.INSTALL CURB STOP30' WATER PIPELINE &ACCESS EASEMENT PERDOC#2273769CONNECT TO EXISTING 4" STUBAT VALVE &11.25° BEND, INSTALL CURB INLETTBC=4668.20INV OUT=4664.85INSTALL 6" PVC STUB TOBUILDING FOR GUTTERCORE INTO BACK OF EXISTINGCURB INLETINV OUT=4662.81(NEW) INV IN=4662.91INSTALL 6" PVC STUB TOBUILDING FOR GUTTEREXISTING STREETLIGHTELECTRIC METERSELECTRIC METERSPROPOSED BURIEDELECTRICAL TOBUILDINGS 3 & 4.PROPOSED TRASHENCLOSURE12' EXISTING P.U.E.12' EXISTING P.U.E.REMOVE 45° BEND ANDREPLACE WITH 22° BEND W/M.R.ENSURE RESTRAINED AT MAININSTALL 45° BENDS& CLEANOUTS9'X5' MECHANICAL/RISER ROOM9'X5' MECHANICAL/RISER ROOM9'X5' MECHANICAL/RISER ROOMINSTALL 114' OF 2" COPPERWATER SERVICE & 2" METERLIVE TAP EXISTING 12" D.I.P.INSTALL CURB STOPLIVE TAP EXISTING 12" D.I.P. &INSTALL 4" VALVELIVE TAP EXISTING 12" D.I.P.LIVE TAP EXISTING 12" D.I.P. &INSTALL 4" VALVEINSTALL 108' OF 4" D.I.P. &OS&Y VALVECONNECT TOEXISTING 4"PVC SEWERSERVICESINSTALL 109' OF 2" COPPERWATER SERVICE & 2" METERINSTALL 102' OF 4" D.I.P. &OS&Y VALVECONNECT TO EXISTING 4"SDR 26 PVC SEWER STUB& EXTEND 68' AT 13%CONNECT TO EXISTING 4"SDR 26 PVC SEWER STUB& EXTEND 186' AT 4.8%INSTALL 45° BEND& CLEANOUTINSTALL 45° BEND& CLEANOUTINSTALL 86' OF 4" D.I.P. &OS&Y VALVE INSTALL 4" 90° BEND W/M.R.REPLACE EXISTING 1.5"SERVICE W/2" COPPERSERVICE, L=110'INSTALL CURB STOP12" RCP STORM PIPE5' SIDE YARD SETBACK20' REAR YARD SETBACK20' REAR YARD SETBACK GENERAL NOTES:1.CONTRACTOR TO SCHEDULE LIVE TAPS AND VALVE OPERATIONS WITH THE CITY OFBOZEMAN A MINIMUM OF 24 HOURS IN ADVANCE.2.ALL CONSTRUCTION, MATERIALS, AND TESTING SHALL CONFORM TO MPWSS, CURRENTEDITITION, AND THE CITY OF BOZEMAN'S (COB) MODIFICATIONS TO MPWSS.3.COB DETAILS SHOWN ARE INCORPORATED FOR REFERENCE, AND ARE NOTALL-INCLUSIVE. THE CURRENT EDITION OF MPWSS AND COB MODIFICATIONS DETAILSAND SPECIFICATIONS SHALL GOVERN ALL APPLICABLE ITEMS OF WORK.4.SEWER SERVICES TO HAVE A MINIMUM OF 4' OF COVER FROM THE FIRST FLOORELEVATION OF ALL BUILDINGS.5.ALL SEWER SERVICES SHALL BE INSULATED PER DETAIL ABOVE IN AREAS WITH LESSTHAN 5 FEET OF COVER.6.ALL WATER SERVICES TO BE TYPE "K" COPPER PIPE AT INSTALLED AT A MINIMUM OF 6.5'DEEP.7.SEPARATE PLANS AND SPECIFICATIONS MUST BE SUBMITTED TO THE CITY ANDAPPROVED PRIOR TO INSTALLATION OF ALL FIRE SERVICE LINES.8.HYDRANT MOVE INSTRUCTIONS: EXISTING CONDOS WILL NEED TO BE TAKEN OUT OFSERVICE SO IN ORDER TO GET SERVICE BACK AS FAST AS POSSIBLE, ENTIRE HYDRANTLEAD SHALL BE RESTRAINED OR OTHER METHODS OF IMMEDIATE RESTRAINT UTILIZED.ALL NEW PIPE AND FITTINGS TO BE SWABBED WITH BLEACH DURING INSTALLATION. NOBAC-T WILL BE REQUIRED FOR THIS WORK PRIOR TO TURNING ON THE WATER AGAINSINCE IT IS LESS THAN 20' OF NEW PIPE PER NICK PERICICH WITH THE BOZEMAN WATERDEPARTMENT.MOVE EXISTING COMM. LINESAWCUT EXISTING ASPHALTABANDON EXISTING 1.5"SERVICE AT MAINCONNECT TO EXISTING 4"D.I.P. FIRE STUB AT VALVEEXISTING FDC87'22.5° BEND22.5° BENDSINGLE PHASETRANSFORMER TO BEREMOVEDFDC FOR BLDG 1