Loading...
HomeMy WebLinkAbout143 ELECTRICAL COVER SHEETJ POWER DEVICES LIGHTING DEVICES F F F V W C B NA D ELECTRICAL ABBREVIATIONS ELECTRICAL LEGEND T INTERIOR MOUNTING HEIGHTS CB CO2 JJ FUSED DISCONNECT SWITCH NON-FUSED DISCONNECT SWITCH COMBINATION STARTER/DISCONNECT SWITCH LAY-IN OR RECESSED LIGHTING FIXTURE SURFACE MOUNTED LIGHTING FIXTURE DIRECT/ INDIRECT LIGHTING PENDANT MOUNTED FIXTURE. SURFACE MOUNTED OR CHAIN HUNG STRIP FIXTURE WALL BRACKET LIGHTING FIXTURE SURFACE MOUNTED CYLINDER FIXTURE WALL MOUNTED FIXTURE FILLED CENTER OR SLASH INDICATES FIXTURE IS AN EMERGENCY DEVICE WITH EMERGENCY BATTERY PACK OR CONNECTED TO EMERGENCY POWER. EXIT SIGN, BRACKET INDICATES WALL MOUNTING. NUMBER OF FACES AND DIRECTION INDICATED BY FILLED AREAS. DOUBLE HEAD WALL MOUNTED BATTERY PACK POWERED EGRESS FIXTURE. SQUARE HEAD POLE MOUNTED SITE LIGHT FIXTURE. ROUND HEAD POLE MOUNTED SITE LIGHT FIXTURE.1'-6"FINISHED CEILING FINISHED FLOOR COD COD COD TOD 44"54"74" TO TOP OF TRIMBOD 80" MINIMUM TO BOTTOM84" AFF TO BOTTOM OF DEVICE OR 6"BELOW CEILING TO TOP OF DEVICE,WHICHEVER IS LOWER.WATT MISER WITH WATT(S) WIRE VESTIBULE VOLT(S) UNIT HEATER UNDERGROUND TELEPHONE UNDERGROUND ELECTRICAL UNDERGROUND TYPICAL TELEVISION TELEPHONE BACK BOARD SWITCH STORAGE STEEL STANDARD SPECIFICATIONS SWITCH, PILOT SOLID NEUTRAL SHEET SUPPLY FAN SERVICE RAPID START RESTROOMS ROOM(S) ROOM REQUIRED REFRIGERANT REFRIGERATOR RECEPTACLES RECEPTACLE RETURN AIR FAN PROVIDE & INSTALL PRODUCE PREPARATION PANEL PHASE OVERHEAD OFFICE OVER CURRENT PROTECTION NUMBER NOT IN CONTRACT LIGHT WHITE LIGHTS KILOWATT(S) KILIVOLT AMPERE(S) KITCHEN WM W/ W W VEST V UH UGT UGE UG TYP TV TBD SW STOR STL STD SPECS SP SN SHT SF SER RS RR RMS RM REQD REFR REF RECPTS RECP RAF P/I PROD PREP PNL P OH OFF OCP NO NIC LW LTS KW KVA KIT JUNCTION BOX INCORPORATED HERTZ HOT WATER HEATER HEATERS HOT WATER HEIGHT HIGH INTENSITY DISCHARGE HIGH PRESSURE SODIUM HORSEPOWER GROUND FAULT CIRCUIT INTERRUPTER FOOT FULL LOAD AMPS FIXTURE FACILITY FIRE ALARM EXTERIOR ELECTRIC WATER COOLER ETCETERA ENGINEER EMERGENCY ESTIMATED MAXIMUM DEMAND ELECTRIC EXHAUST FAN COOL WHITE CABLE TELEVISION COPPER CONTRACTOR CONDENSER COMPRESSOR COMMISSARY CIRCUIT CABINET UNIT HEATER CUBIC FEET PER MINUTE CIRCUIT BREAKER CONDUIT BRITISH THERMAL UNIT/HOUR BREAKER BUILDING APPROXIMATE APPLIANCE AMPERE(S) AIR HANDLING UNIT ABOVE FINISH FLOOR ADMINISTRATION ADJUSTABLE AIR CONDITIONING UNIT AIR CONDITIONING CONDENSING UNIT AMP(S) J-BOX INC HZ HWH HTRS HW HT HID HPS HP GFCI FT FLA FIX FAC FA EXT EWC ETC ENGR EMER EMD ELEC EF CW CTV CU CONTR COND COMP COMM CCT CUH CFM CB C BTU/HR BRK BLDG APPROX APPL AMP AHU AFF ADMIN ADJ ACU ACCU A ALUMINUMAL VOLT AMPERESVA ATS AUTOMATIC TRANSFER SWITCH CWP COLD WATER PUMP HWP HOT WATER PUMP SDP SUB DISTRIBUTION PANEL KILOHERTZKHZ CCTV CLOSED CIRCUIT TELEVISION COM COMMUNICATION FACP FIRE ALARM CONTROL PANEL RA REMOTE ANNUNCIATOR GFI GROUND FAULT INTERRUPTER EC ELECTRICAL CONTRACTOR GENERAL CONTRACTORGC XFMR TRANSFORMER SPST SWITCH, SINGLE POLE- SINGLE THROW 48"COD SITE GROUND MOUNTED FLOOD FIXTURE REMOTE DOUBLE HEAD EGRESS FIXTURE WALL SCONCE FIXTURE COD 36"SPECIAL PURPOSE CONNECTION, BRACKET INDICATES WALL MOUNTING, BOX INDICATES FLOOR MOUNTING JUNCTION BOX, BRACKET INDICATES WALL MOUNTING, BOX INDICATES FLOOR MOUNTING RECESSED DOWN LIGHT, HALF MOON INDICATES WALL WASH TRIM AND DIRECTION. J POWER DEVICES LIGHTING DEVICES F F F V W C B NA D ELECTRICAL ABBREVIATIONS T INTERIOR MOUNTING HEIGHTS CB CO2 JJ PAD MOUNTED UTILITY TRANSFORMER FUSED DISCONNECT SWITCH NON-FUSED DISCONNECT SWITCH COMBINATION STARTER/DISCONNECT SWITCH LAY-IN OR RECESSED LIGHTING FIXTURE SURFACE MOUNTED LIGHTING FIXTURE DIRECT/ INDIRECT LIGHTING PENDANT MOUNTED FIXTURE. SURFACE MOUNTED OR CHAIN HUNG STRIP FIXTURE WALL BRACKET LIGHTING FIXTURE SURFACE MOUNTED CYLINDER FIXTURE WALL MOUNTED FIXTURE FILLED CENTER OR SLASH INDICATES FIXTURE IS AN EMERGENCY DEVICE WITH EMERGENCY BATTERY PACK OR CONNECTED TO EMERGENCY POWER. EXIT SIGN, BRACKET INDICATES WALL MOUNTING. NUMBER OF FACES AND DIRECTION INDICATED BY FILLED AREAS. DOUBLE HEAD WALL MOUNTED BATTERY PACK POWERED EGRESS FIXTURE. SQUARE HEAD POLE MOUNTED SITE LIGHT FIXTURE. ROUND HEAD POLE MOUNTED SITE LIGHT FIXTURE.1'-6"FINISHED CEILING FINISHED FLOOR COD COD COD TOD 44"54"74" TO TOP OF TRIMBOD 80" MINIMUM TO BOTTOMAC = MINIMUM 4" ABOVE BACKSPLASH TO BOTTOM OF DEVICE.84" AFF TO BOTTOM OF DEVICE OR 6"BELOW CEILING TO TOP OF DEVICE,WHICHEVER IS LOWER.WATT MISER WITH WATT(S) WIRE VESTIBULE VOLT(S) UNIT HEATER UNDERGROUND TELEPHONE UNDERGROUND ELECTRICAL UNDERGROUND TYPICAL TELEVISION TELEPHONE BACK BOARD SWITCH STORAGE STEEL STANDARD SPECIFICATIONS SWITCH, PILOT SOLID NEUTRAL SHEET SUPPLY FAN SERVICE RAPID START RESTROOMS ROOM(S) ROOM REQUIRED REFRIGERANT REFRIGERATOR RECEPTACLES RECEPTACLE RETURN AIR FAN PROVIDE & INSTALL PRODUCE PREPARATION PANEL PHASE OVERHEAD OFFICE NUMBER NOT IN CONTRACT LIGHT WHITE LIGHTS KILOWATT(S) KILIVOLT AMPERE(S) KITCHEN WM W/ W W VEST V UH UGT UGE UG TYP TV TBD SW STOR STL STD SPECS SP SN SHT SF SER RS RR RMS RM REQD REFR REF RECPTS RECP RAF P/I PROD PREP PNL P OH OFF OCP NO NIC LW LTS KW KVA KIT JUNCTION BOX INCORPORATED HERTZ HOT WATER HEATER HEATERS HOT WATER HEIGHT HIGH INTENSITY DISCHARGE HIGH PRESSURE SODIUM HORSEPOWER GROUND FAULT CIRCUIT INTERRUPTER FOOT FULL LOAD AMPS FIXTURE FACILITY FIRE ALARM EXTERIOR ELECTRIC WATER COOLER ETCETERA ENGINEER EMERGENCY ESTIMATED MAXIMUM DEMAND ELECTRIC EXHAUST FAN COOL WHITE CABLE TELEVISION COPPER CONTRACTOR CONDENSER COMPRESSOR COMMISSARY CIRCUIT CABINET UNIT HEATER CUBIC FEET PER MINUTE CIRCUIT BREAKER CONDUIT BRITISH THERMAL UNIT/HOUR BREAKER BUILDING APPROXIMATE APPLIANCE AMPERE(S) AIR HANDLING UNIT ABOVE FINISH FLOOR ADMINISTRATION ADJUSTABLE AIR CONDITIONING UNIT AIR CONDITIONING CONDENSING UNIT AMP(S) J-BOX INC HZ HWH HTRS HW HT HID HPS HP GFCI FT FLA FIX FAC FA EXT EWC ETC ENGR EMER EMD ELEC EF CW CTV CU CONTR COND COMP COMM CCT CUH CFM CB C BTU/HR BRK BLDG APPROX APPL AMP AHU AFF ADMIN ADJ ACU ACCU A ALUMINUMAL VOLT AMPERESVA ATS AUTOMATIC TRANSFER SWITCH CWP COLD WATER PUMP HWP HOT WATER PUMP SDP SUB DISTRIBUTION PANEL KILOHERTZKHZ CCTV CLOSED CIRCUIT TELEVISION COM COMMUNICATION FACP FIRE ALARM CONTROL PANEL RA REMOTE ANNUNCIATOR GFI GROUND FAULT INTERRUPTER EC ELECTRICAL CONTRACTOR GENERAL CONTRACTORGC XFMR TRANSFORMER SPST SWITCH, SINGLE POLE- SINGLE THROW 48"COD SITE GROUND MOUNTED FLOOD FIXTURE REMOTE DOUBLE HEAD EGRESS FIXTURE WALL SCONCE FIXTURE COD 36"SPECIAL PURPOSE CONNECTION, BRACKET INDICATES WALL MOUNTING, BOX INDICATES FLOOR MOUNTING JUNCTION BOX, BRACKET INDICATES WALL MOUNTING, BOX INDICATES FLOOR MOUNTING ELECTRICAL PANEL - SEE PANEL SCHEDULES FOR MOUNTING CONFIGURATION RECESSED DOWN LIGHT, HALF MOON INDICATES WALL WASH TRIM AND DIRECTION.DOOR POWER SUPPLY DISCONNECT DIAMETER DPS DISC DIA DISCONNECT DIAMETER DISC DIA DRAWINGDWG MFG MANUFACTURER MOUNTED MAIN PANEL MAIN LUGS ONLY MINIMUM MECHANICAL MAIN CIRCUIT BREAKER MOMENTARY CONTACT MTD MP MLO MIN MECH MCB MOC MAIN DISTRIBUTION PANELMDP MFA MINIMUM FEEDER AMPACITY MC MECHANICAL CONTRACTOR MFG MANUFACTURER MOUNTED MAIN PANEL MAIN LUGS ONLY MINIMUM MECHANICAL MAIN CIRCUIT BREAKER MOMENTARY CONTACT MTD MP MLO MIN MECH MCB MOC MAIN DISTRIBUTION PANELMDP MFA MINIMUM FEEDER AMPACITY MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPSMCA MAXIMUM OVERCURRENT PROTECTION MOCP MISCELLANEOUS LEGEND NORMAL CIRCUIT CONCEALED IN WALL OR EXPOSED UNDERGROUND OR BURIED CIRCUIT HOMERUN TO ELECTRICAL PANEL NUMBER OF HASH MARKS INDICATES NUMBER OF CURRENT CARRYING CONDUCTORS. NO MARKS INDICATES TWO. GROUNDING CONDUCTOR NOT SHOWN BUT SHALL BE INCLUDED IN ALL CONDUITS. W/WITH AC ABOVE COUNTER EC ELECTRICAL CONTRACTOR (E)EXISTING (R) RELOCATED (N) NEW DEVICE C BFG BELOW FINISHED GRADE UC UNDER COUNTER WP WEATHER PROOF MC MECHANICAL CONTRACTOR REFER TO ELECTRICAL NOTES AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE WM WIRE MOLD GC GENERAL CONTRACTOR GND GROUND UG UNDER GROUND BOD BOTTOM OF DEVICE TOD TOP OF DEVICE COD CENTER OF DEVICE BOF BOTTOM OF FIXTURE PC PLUMBING CONTRACTOR MISCELLANEOUS LEGEND NORMAL CIRCUIT CONCEALED IN WALL OR EXPOSED UNDERGROUND OR BURIED CIRCUIT HOMERUN TO ELECTRICAL PANEL NUMBER OF HASH MARKS INDICATES NUMBER OF CURRENT CARRYING CONDUCTORS. NO MARKS INDICATES TWO. GROUNDING CONDUCTOR NOT SHOWN BUT SHALL BE INCLUDED IN ALL CONDUITS. W/WITH AC ABOVE COUNTER EC ELECTRICAL CONTRACTOR (E)EXISTING (R) RELOCATED (N) NEW DEVICE C CONDUIT BFG UC UNDER COUNTER WP WEATHER PROOF MC MECHANICAL CONTRACTOR AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE WM WIRE MOLD GC GENERAL CONTRACTOR GND GROUND UG UNDER GROUND BOD BOTTOM OF DEVICE TOD TOP OF DEVICE COD CENTER OF DEVICE BOF BOTTOM OF FIXTURE PC PLUMBING CONTRACTOR 1 HAND HOLE CONNECT GROUND TO POLE LUG, GROUND LUG PROVIDED WITH POLE BUSH CONDUIT ENDS 1" CHAMFER 1 1/2" MIN. FINISH GROUT ANCHOR BOLT TO BE FURNISHED BY POLE MANUFACTURER 3-#3 TIES AT TOP OF FORM FINISH GRADE LINE 5 NO. 6 REBARS BELOW GRADE 5 NO. 3 TIE RODS REINFORCE CONCRETE BASE BY GENERAL CONTRACTOR 24" ROUND UNDISTURBED SOIL SEE SITE PLAN FOR BRANCH CIRCUIT WIRING 66" 24" 48" EDGE OF CURB OR PAVED AREA. 24" MIN. BASE COVER PROJECT ANCHOR BOLTS ABOVE TOP OF BASE. PROVIDE DOUBLE NUTS FOR LEVELING UNIT (ONE ABOVE AND BELOW BASE FLANGE) GROUT VOID BETWEEN BASE FLANGE AND TOP OF CONCRETE, HAND FINISH. TEMPLATE TO BE FURNISHED BY POLE MANUFACTURER. POLE TO BE 18' IN HEIGHT FINISH GRADE LINE 5 NO. 6 REBARS BELOW GRADE 5 NO. 3 TIE RODS REINFORCE CONCRETE BASE BY GENERAL CONTRACTOR 24" ROUND UNDISTURBED SOIL SEE SITE PLAN FOR BRANCH CIRCUIT WIRING 66" 24" BASE COVER PROJECT ANCHOR BOLTS ABOVE TOP OF BASE. PROVIDE DOUBLE NUTS FOR LEVELING UNIT (ONE ABOVE AND BELOW BASE FLANGE) GROUT VOID BETWEEN BASE FLANGE AND TOP OF CONCRETE, HAND FINISH. TEMPLATE TO BE FURNISHED BY POLE MANUFACTURER. 1" CHAMFER 1 1/2" MIN. FINISH GROUT ANCHOR BOLT TO BE FURNISHED BY POLE MANUFACTURER 3-#3 TIES AT TOP OF FORM HAND HOLE CONNECT GROUND TO POLE LUG, GROUND LUG PROVIDED WITH POLE BUSH CONDUIT ENDS POLE TO BE 12' IN HEIGHT ACE JOB 22BZ5529 12 N. BROADWAY SECOND FLOOR BELGRADE, MT 59714 406-388-3320 Sheet Number: © 2022 Solomon Cordwell Buenz Project Number: Drawn By:Checked By: ELECTRICAL COVER SHEET ES0.00 2022001.000 Author Checker Tschache Lane & 27 Ave. Bozeman, MT 59718 2695 TSCHACHE LANE ELECTRICAL SHEET LIST ES0.00 ELECTRICAL COVER SHEET ES0.31 ELECTRICAL SITE PLAN ES0.32 ELECTRICAL SITE PHOTOMETRIC PLAN ES1.01 ELECTRICAL CUTSHEETS I ES1.02 ELECTRICAL CUTSHEETS II ES1.03 ELECTRICAL CUTSHEETS III ES2.00 BUILDING ELECTRICAL SERVICE DETAILSNOT TO SCALE1POLE BASE DETAIL LUMINAIRE SCHEDULE CALLOUT MANUFACTURER MODEL MOUNTING LAMP ELECTRICAL DATA DESCRIPTION P1 LITHONIA RSX2 LED P3 30K R3 MVOLT ** HS ** POLE LED 120 V/1-147 VA SINGLE HEAD POLE LIGHT / COORDINATE FINISH WITH ARCHITECT, FULL-CUTOFF, 18' POLE, HOUSE SHIELD. P2 LITHONIA RSX2 LED P2 30K R3 MVOLT ** HS ** POLE LED 120 V/1-111 VA SINGLE HEAD POLE LIGHT / COORDINATE FINISH WITH ARCHITECT, FULL-CUTOFF, 18' POLE, HOUSE SHIELD. P3 LITHONIA RSX2 LED P3 30K R5 MVOLT ** ** POLE LED 120 V/1-147 VA SINGLE HEAD POLE LIGHT / COORDINATE FINISH WITH ARCHITECT, FULL-CUTOFF, 18' POLE. P4 LITHONIA RADPT LED P3 30K SYM MVOLT PT4 PIR HS ** POLE LED 120 V/1-48 VA ARCHITECTURAL POLE, FULL-CUTOFF, WITH HOUSE SHIELD, 12' HEIGHT. P5 LITHONIA RADPT LED P3 30K SYM MVOLT PT4 PIR ** POLE LED 120 V/1-54 VA ARCHTIECTURAL POLE, FULL-CUTOFF, 12' HEIGHT. S1 LITHONIA CLX L48 5000L SEF FDL WD MVOLT GZ10 30K 80CRI MB SURFACE CEILING LED 120 V/1-32 VA MOUNTING UNER PARKING CANOPY, *** HEIGHT W1 BROWNLEE 7075-24-**-H41-30K-ES P01 WALL LED 120 V/1-41 VA WALL PACK, FULL CUTOFF, 10' MOUNTING HEIGHT. NOT TO SCALE2ARCHITECTURAL POLE BASE DETAIL M O N T A N A PROFE SSIONA L E N G INEERLICENS E D T OOSTERHOUT DARIN VAN 62700 PE 08.31.2022 NO. DATE DESCRIPTION 08.31.2022 SITE PLAN REVIEW DOCUMENTS 09.23.2022 DESIGN DEVELOPMENT A 02.17.2023 SITE PLAN REVIEW - RC 1