HomeMy WebLinkAbout012 ELECTRICAL DETAILS 2REINFORCEDHAND HOLE & COVERSINGLE MEMBER TYPEMASTARM2'-0"2'-0" MIN.30'MAST ARMTYPE E1 - 6 FTFINISHED GRADESIDEWALKLONG REINF.SEESCHEDULEANCHORBOLTS FROMPOLE MANF.2'-6"7'HORIZ. TIESSEESCHEDULEPROVIDE LONG AT ALL FOUR CORNERS OF SQUARE PIER.PROVIDE SPACING OF S/2 AT TOP 1'-0" OF PEIR.DEPTH BELOW FINISHED GRADE.SPACE LONG. STEEL EVENLY AROUND PERIMETER.PROVIDE REINF. CLEARANCE PER ANCI 318.*** ************FINISHGRADE24"SEE SITE PLANFOR CONDUIT SIZE1" CHAMFERREINFORCED CONC.BASE BY E.C.BUSH CONDUITSBASE COVERPROVIDE FUSE(S) IN CKT. TOBALLAST. FUSE(S) SHALL BEBUSS TYP. BBS. FUSE HOLDERSSHALL BE BUSS "TRON" HEBWATERPROOF. SIZE OF FUSESHALL BE AS REQUIRED BYLUMINAIRE MANUFACTURER.CONNECT GROUND TO POLEBASE W/ BOUNDRY #GB4CPROJECT ANCHOR BOLTS 3" MIN.ABOVE TOP OF BASE. PROVIDEDOUBLE NUTS FOR LEVELING UNIT(ONE ABOVE AND ONE BELOW BASEFLANGE). GROUT VOID BETWEENBASE FLANGE AND TOP OFCONCRETE, LEAVING DRAIN HOLE.HAND FINISH.THWN CONDUCTOR AS SHOWN ON PLANSPROVIDE 1' OF COILED SLACK ONCONDUCTOR FEED THRUHANDHOLE - 4" X 6" (NOMINAL)LIGHT FIXTURE BASE SCHEDULE *****POLEHEIGHTSIZELONGSTLHORIZONTALSTL **14' - 30'DEPTH ***HEIGHT AFG7'-0"24" Ø(6) # 6 ****#3 AT 12" O.C.BOLT COUPLING(BREAKAWAY TYPE)BREAKAWAY BOLTCOUPLINGBOLT COVERBREAKAWAY BOLTCOUPLING (ONEOF FOUR)NOTE:CONTRACTOR SHALL COORDINATE AND PROVIDEBOLT COVER FROM THE POLE MANUFACTURER TOENSURE THE CLEANEST LOOK POSSIBLE.6"TYPE IMINIMUM INSIDE DIMENSIONSW = 12 INCHESL = 18 INCHESD = 12 INCHESPULL BOX COMPOSITE1" CLEAN STONEDRAINAGECOPPER OR EQUALCONCRETE SIDEWALK OR PAVERSCONDUIT IN PLACEAS REQUIRED. ELECTRICAL BOND, NO.6 AWGPROVIDE STUB 4-6" ABOVE BOTTOM OF PULL BOX AND CAP CONDUIT FOR FUTURE LUMINAIRESNOTES:FURNISH PULL BOXES AND COVERS MADE OF POLYMER CONCRETE WITH FIBERGLASS REINFORCEMENT.FURNISH PULL BOXES HAVING CONTINUOUS FIBERGLASS CLOTH REINFORCEMENT ON THE INSIDE ANDOUTSIDE PERIMETERS. FURNISH COVERS HAVING A MINIMUM OF TWO LAYERS OF FIBERGLASS CLOTHREINFORCEMENT.ENSURE THE PULL BOXES AND COVERS COMPLY WITH ALL TEST PROVISIONS OF THE MOST CURRENTANSI/SCTE 77 FOR TIER 22 APPLICATIONS. FURNISH PULL BOXES AND COVERS THAT HAVE BEEN TESTED ANDCERTIFIED BY A NATIONALLY RECOGNIZE D THIRD PARTY INDEPENDENT TEST FIRM SUCH AND UL OR ETLVERIFYING THAT THE BOXES AND COVERS MEET ALL TEST PROVISIONS OF THE ANSI/SCTE 77. FURNISH PULLBOXES THAT HAVE MARKINGS SHOWING THE TIER 22 RATING LABELED OR STENCILED ON THE INSIDE ANDOUTSIDE OF THE BOX. FURNISH COVERS THAT MARKING SHOWING THE TIER 22 RATING EMBOSSED IN THE TOPSURFACE OF THE COVER. FURNISH COVERS HAVING PULL SLOTS RATED FOR A MINIMUM PULL OUT OF 3,000POUNDS.FURNISH 3/8-7 LAB THREAD HEX HEAD BOLTS TO SECURE THE COVER TO THE PULL BOX.CITY LIGHTINGHOLD DOWN BOLTS LUMINAIRE SCHEDULESYMBOLTYPELAMPSLUMENSDESCRIPTIONSMANUFACTURERCATALOG NO. OR SERIESMOUNTING/VOLTAGEE138WLED4,138 RATED (3,972 WITHADJUSTABLEWATTAGESELECTOR)FULL CUTOFF AREA LIGHT WITH TYPE II DISTRIBUTION. MOUNT FIXTURE ON 30FT ROUNDTAPERED STEEL POLE WITH 6FT ARM. MOUNT ON CONCRETE BASE PER CITY REQUIREMENTS.PROVIDE HUNTER GREEN FINISH (RAL#6005) PER CITY OF BOZEMAN STANDARDS. PROVIDE ARMAND POLE PER CITY OF BOZEMAN STANDARDS. LUMINAIRE SELECTION AND PLACEMENT ISBASED ON NEW DRAFT STANDARD FOR OUTPUT. SET FIELD ADJUSTABLE WATTAGE SELECTORTO .9PHILIPSRFS-35W-16LED-2.7K-G2-R2M-UNV-FAWS-DMG-RCD7-HS-CUSTOMCOLOR RAL 6005POLE/2401PULL BOX DETAILNOT TO SCALE2TYPE E1 LUMINAIRE DETAILNOT TO SCALE4POLE BASE DETAILNOT TO SCALE3BREAKAWAY BOLT COUPLING DETAILNOT TO SCALESheetNumber:© 2022 Solomon Cordwell BuenzProjectNumber:Drawn By:Checked By:Tschache Lane & 27 Ave.Bozeman, MT 597182695 Tschache Lane2022001.000NO.DATEDESCRIPTIONSITE PLAN REVIEW - RC 102.17.2023ASITE PLAN REVIEW SUBMISSION08.31.20224SITE PLAN REVIEW - RC 205.10.2023BELECTRICALDETAILS 2CCFWEHC1-10SITE PLAN RC-2 05/2023