HomeMy WebLinkAbout053 E0.1 General Notes  SHEET NUMBERPROJECT CODEPROJECT ADDRESSARCHITECT RETAINS COPYRIGHT TO THESE DRAWINGS.DRAWINGS ARE ONLY FOR USE FOR PROJECT NAMED ONDRAWING SHEET AND MAY NOT BE REPRODUCED OR USEDFOR OTHER PURPOSES WITHOUT WRITTEN PERMISSIONFROM ARCHITECT.NWBWEST PARKNEIGHBORHOODLOT R1A NORTONRANCH SUBDIVISIONSITE PLAN REVIEW106 EAST BABCOCK STREETSUITE 1ABOZEMAN, MT 59715SHEET NAMEPROJECT NAMEDRAWING REVISIONSDRAWING ISSUE DATEDRAWING ISSUED FORPHONE: (406) 582-8988E0.1GENERALNOTES12-01-2022GENERAL NOTES:1.IN GENERAL, EXISTING STRUCTURES AND FACILITIES ARE NOTED AS "EXISTING" AND ARE SHOWN IN LIGHT LINE WEIGHTS OR AS SCREENED BACKGROUND. NEW STRUCTURES OR FACILITIESARE SHOWN IN HEAVY LINE WEIGHTS.2.PRIOR TO BID, CONTRACTOR SHALL VISIT THE SITE. NOT ALL WORK REQUIRED TO COMPLETE THE PROJECT IS SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL BE COME THOROUGHLYFAMILIAR WITH ALL THE WORK REQUIRED TO COMPLETE THE PROJECT IN ADDITION TO THE LOCAL CONDITIONS AND INCLUDE SAID WORK IN THE BID.3.GENERAL WORK PRACTICES FOR ELECTRICAL CONSTRUCTION SHALL BE IN ACCORDANCE WITH NECA 1, "STANDARD PRACTICES FOR GOOD WORKMANSHIP IN ELECTRICAL CONTRACTING."THIS PUBLICATION IS AVAILABLE FROM NCSA BY TELEPHONE AT 301-215-4521 OR ON-LINE AT WWW.NECA-NEIS.ORG.4.THE CONTRACTOR SHALL NOTIFY THE MONTANA ONE CALL CENTER @ 811 OR (800) 551-8344 FOR ON-SITE UTILITY LOCATION. ALL KNOWN EXISTING UTILITIES SHALL BE MARKED BEFOREDIGGING.5.CONTRACTOR SHALL HAVE APPROVAL FROM ALL GOVERNING AGENCIES HAVING JURISDICTION OVER ANY UTILITY SYSTEM PRIOR TO INSTALLATION.CONSTRUCTION NOTES:1.THE LOCATION, DEPTH, AND SIZE OF EXISTING UTILITIES SHOWN ON THESE PLANS IS APPROXIMATE. THE CONTRACTOR SHALL FIELD VERIFY THE EXISTENCE, LOCATION, DEPTH, SIZE, LINEAND GRADE OF EXISTING UTILITY CONNECTIONS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY DAMAGE TO THE EXISTING FACILITIES DUE TOFAILURE TO LOCATE OR PROVIDE PROPER PROTECTION WHEN LOCATION IS KNOWN.2.LOCATION OF SITE UTILITIES SHALL BE VERIFIED BY CONTRACTOR AND THE UTILITY COMPANY PROVIDING SERVICE. ANY PROPOSED ADJUSTMENTS TO DRY UTILITY LOCATION SHALL BECOORDINATED WITH UTILITY COMPANIES.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL ELECTRICAL SERVICE WORK WITH NORTHWESTERN ENERGY. OWNER PAYS ALL FEES, CONTRACTOR DOES ALLSCHEDULING AND COORDINATION OF NORTHWESTERN ENERGY WORK. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE ALL SCHEDULES ARE MET.4.ALL IMPROVEMENTS ON THIS PROJECT SHALL BE COMPLETED IN ACCORDANCE WITH THE MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS, SEVENTH EDITION DATED APRIL 2021(MPWSS); THE CITY OF BOZEMAN MODIFICATIONS TO THE MPWSS; AND THE PROJECT SPECIFICATIONS.5.CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE DIVISION OF INDUSTRIAL REGULATIONS (OSHA) SAFETY STANDARDS. IF REQUESTED BY THE INSPECTOR, THE CONTRACTOR SHALLPROVIDE PROOF OF A PERMIT FROM SAID DIVISION.6.THE CONTRACTOR'S OPERATIONS SHALL BE CONFINED WITHIN THE PROJECT LIMITS. MATERIALS AND EQUIPMENT SHALL BE STORED ON THE PROJECT SITE WHERE APPROVED BY THEOWNER. IT SHALL BE UNDERSTOOD THAT THE RESPONSIBILITY FOR PROTECTION AND SAFEKEEPING OF EQUIPMENT AND MATERIALS ON OR NEAR THE SITE WILL BE ENTIRELY THAT OF THECONTRACTOR AND THAT NO CLAIM SHALL BE MADE AGAINST THE OWNER BY REASON OF ANY ACT OF AN EMPLOYEE OR TRESPASSER.7.CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION. ANY DISCREPANCIES FOUND ARE TO BE BROUGHT TO THE ENGINEER'S ATTENTION PRIOR TOCOMMENCEMENT OR CONTINUATION OF CONSTRUCTION ACTIVITIES.8.REFERENCE ALL SURVEY MONUMENTS, SECTION CORNERS, 1/4 CORNERS, AND PROPERTY CORNERS PRIOR TO BEING DISTURBED BY CONSTRUCTION. ANY MONUMENTS AND CORNERSDISTURBED DURING CONSTRUCTION SHALL BE REPLACED BY A PROFESSIONAL LAND SURVEYOR (PLS) REGISTERED IN THE STATE OF MONTANA.9.A PRE-CONSTRUCTION MEETING (AS REQUIRED) SHALL BE HELD WITH THE GENERAL CONTRACTOR, SITE SUBCONTRACTOR,CITY OF BOZEMAN, OWNER, AND MORRISON-MAIERLE, INC. PRIORTO THE START OF CONSTRUCTION.10.THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND THE CITY, COUNTY, AND/OR STATE INSPECTOR 48 HOURS PRIOR TO COMMENCING CONSTRUCTION AND 24 HOURS IN ADVANCE OFSPECIFIC INSPECTION NEEDS DURING THE COURSE OF THE WORK. ALL WORK SHALL BE PERFORMED DURING NORMAL WORKING HOURS AND SUBJECT TO THE AVAILABILITY OF ANINSPECTOR AND APPROVED BY THE ENGINEER. THE CONTRACTOR WILL BE BILLED FOR SAID INSPECTION SERVICES AS PROVIDED IN THE MOST RECENTLY ADOPTED FEES FOR SUCHSERVICES.11.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL PUBLIC AND PRIVATE PROPERTY INSOFAR AS IT MAY BE AFFECTED BY THESE OPERATIONS, ALL COSTS FOR PROTECTING,REMOVING, AND RESTORING EXISTING IMPROVEMENTS SHALL BE BORNE SOLELY BY THE CONTRACTOR.12.THE CONTRACTOR SHALL IMMEDIATELY CLEAN UP ANY CONSTRUCTION MATERIALS INADVERTENTLY DEPOSITED ON EXISTING STREETS, SIDEWALKS, OR OTHER PUBLIC RIGHTS-OF-WAY ANDMAKE SURE STREETS AND WALKWAYS ARE CLEANED AT THE END OF EACH WORKING DAY.13.CONSTRUCTION WORK ZONE TRAFFIC SIGNS SHALL BE FURNISHED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH APPLICABLE REQUIREMENTS OF THE REGULATORY AGENCIESHAVING JURISDICTION. A TRAFFIC CONTROL PLAN, PREPARED BY THE CONTRACTOR, MAY BE REQUIRED BY THE CITY OR STATE. "CONSTRUCTION AHEAD" WARNING SIGNS ARE TO TO BEINSTALLED ALONG ADJACENT ROADS OR DRIVEWAYS. FLASHERS WITH CAUTION TAPE ARE TO BE INSTALLED WHERE ANY CONSTRUCTION ACTIVITY CROSSES A SIDEWALK OR PEDESTRIANPATH IN ACCORDANCE WITH THE SPECIFICATIONS AND ANY OR ALL LOCAL REGULATIONS.14.THE CONTRACTOR SHALL RESTORE ALL ROADWAY SURFACES TO EQUAL OR BETTER CONDITION THAN EXISTED PRIOR TO EXCAVATION AS DETERMINED BY AGENCY, OWNER, AND/ORENGINEER.15.THE CONTRACTOR SHALL UTILIZE COMPACTION EQUIPMENT SUITABLE FOR THE SOIL TYPES AND SURFACE MATERIALS ENCOUNTERED ON THE PROJECT.16.CONTRACTOR IS RESPONSIBLE FOR PROJECT DUST CONTROL.Know what'sbelow.before you dig.CallRINCOMING ELECTRICAL SERVICEDIVISION OF RESPONSIBILITYELEC.CONTR.UTILITYCO.PRIMARY CONDUITXPRIMARY CONDUCTORSXPOLE MOUNTTRANSFORMERXPOLE RISERXTRANSFORMERCONNECTIONSXSECONDARY CONDUITXSECONDARYCONDUCTORSXDISCONNECTXMETER BASEXMETERXNOTES:1. CONTACT AND COORDINATE ALL REQUIREMENTS AND RESPONSIBILITIES WITH SERVING UTILITY COMPANIES PRIOR TO SUBMITTING BID2. ALL SERVICE INSTALLATION WORK SHALL BE IN STRICT COMPLIANCE WITH THE REQUIREMENTS OF THE SERVING UTILITIES.MORRISON MAIERLE, INC. HAS CONTACTED THE UTILITIES BUT HAS NOT RECEIVED INWRITING THE FINAL REQUIREMENTS FROM THE POWER UTILITY.THESE DRAWINGS INDICATE OUR BEST ESTIMATION OF THEIR REQUIREMENTS. PRIOR TOBID CONTACT THE UTILITIES AND OBTAIN IN WRITING THEIR REQUIREMENTS.ELECTRICAL SYMBOL LEGENDSYMBOLDESCRIPTIONSMOUNTINGHEIGHT, UNOBRANCH CIRCUIT WIRING. ARROW INDICATES HOME RUN TO PANEL WITH CIRCUITS AS NOTED. WIRESIZE IS #12 UNLESS NOTED OTHERWISE. SHORT TICK MARKS INDICATE PHASE CONDUCTORS. LONGTICK MARKS INDICATE NEUTRAL CONDUCTORS. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOREACH 120V BRANCH CIRCUIT. A SINGLE INSULATED GREEN GROUND CONDUCTOR SHALL BE PROVIDEDWITH EACH HOME RUN.RACEWAY BELOW FLOOR OR BELOW GRADERACWAY STUB-OUT OR STUB-UP WITH BUSHED ENDPAD MOUNTED TRANSFORMERUTILITY ELECTRIC METER SEE DETAIL 2/E0.3.METERLINE BREAKHANDHOLE SEE DETAIL 3/E0.2KEY NOTE. REFER TO SPECIFIC NOTE ON SAME DRAWING SHEET.POLE MOUNTED LUMINAIRE ASSEMBLY SECURED TO CONCRETE BASE. LETTER INDICATES FIXTURETYPE.PHOTOCELLDUPLEX RECEPTACLE.18"SPECIAL PURPOSE OUTLET, LETTER INDICATES TYPE. SEE SPEC.18"JUNCTION BOXFUSED DISCONNECT SWITCHBRANCH CIRCUIT PANELBOARD BREAKERCONTACTOR1. THESE SYMBOLS COMPRISE A STANDARD LIST; NOT ALL SYMBOLS APPEAR ON THIS PROJECT.2. ALL MOUNTING HEIGHTS ARE TO CENTER OF DEVICE ABOVE FINISHED FLOOR. MOUNTING HEIGHTSINDICATED ON ARCHITECTURAL WALL ELEVATIONS OR AS NOTED SPECIFICALLY ON THE DRAWINGSOR IN THE SPECIFICATIONS SHALL TAKE PRECEDENCE OVER MOUNTING HEIGHTS LISTED.P-1,3,5MMHH1PAJCABBREVIATIONSA or AMPAMPERESACALTERNATING CURRENTA/CAIR CONDITIONINGAFAMP FUSEAFFABOVE FINISHED FLOORAFGABOVE FINISHED GRADEALALUMINUMASAMP SWITCHBASBUILDING AUTOMATION SYSTEMBKRBREAKERCRACEWAY/CONDUITCBCIRCUIT BREAKERCCTVCLOSED CIRCUIT TELEVISIONCKTCIRCUITC.O.RACEWAY/CONDUIT ONLY, WITH PULL STRINGCNTRLCONTROLCUCOPPERDISCDISCONNECTDISTDISTRIBUTIONDPDTDOUBLE POLE DOUBLE THROWDWGDRAWINGEAEACHEFEXHAUST FANELECELECTRICEMTELECTRICAL METALLIC TUBINGEQUIPEQUIPMENTEX OREXISTEXISTINGFDFUSED DISCONNECTFLRFLOORFOFIBER OPTICFVNRFULL VOLTAGE NON-REVERSINGFVRFULL VOLTAGE REVERSINGGECGROUNDED ELECTRODE CONDUCTORGFIGROUND FALUT INTERRUPTERGNDGROUNDGRCGALVANIZED RIGID CONDUITHIDHIGH INTENSITY DISCHARGEHOAHAND-OFF-AUTOMATICHPHORSEPOWERHPSHIGH PRESSURE SODIUMHTRHEATERHZHERTZJ-BOXJUNCTION BOXKVAKILOVOLT AMPERESKWKILOWATTSLTGLIGHTINGMAXMAXIMUMMHMETAL HALIDEMINMINIMUMNNEUTRALNCNORMALLY CLOSEDNECNATIONAL ELECTRICAL CODENEMANATIONAL ELECTRICAL MANUFACTURERSASSOCIATIONNFDNON-FUSED DISCONNECTNICNOT IN CONTRACTNONORMALLY OPEN#NUMBEROCON CENTEROHOVERHEADPPOLEPBPUSHBUTTONPNLPANELPVCPOLYVINYL CHLORIDE CONDUITPWRPOWERRECEPTRECEPTACLERGSRIGID GALVANIZED STEELRMROOMRVNRREDUCED VOLTAGE NON-REVERSINGRVRREDUCED VOLTAGE REVERSINGSPSINGLE POLE TOGGLE SWITCHSPECSPECIFICATIONSPSTSINGLE POLE SINGLE THROWSSPBSTART-STOP PUSHBUTTONSWSWITCHTCTIME CLOCKTDTIME DELAYTSPTWISTED SHIELDED PAIRTTBTELEPHONE TERMINAL BOARDTYPTYPICALUGUNDERGROUNDUHUNIT HEATERUNOUNLESS NOTED OTHERWISEUONUNLESS OTHERWISE NOTEDVVOLTVAVOLT AMPERESWWATTSWPWEATHERPROOFW/OWITHOUTXFMRTRANSFORMERYWYE CONNECTEDDELTA CONNECTEDPHASE*THESE ABBREVIATIONS COMPRISE A STANDARD LIST;NOT ALL ABBREVIATIONS APPEAR ON THIS PROJECT.ENTITYPOWER & GASPROJECT CONTACT LISTFIRM OR AGENCYADDRESSCONTACTPHONE & EMAILNORTHWESTERN ENERGY121 EAST GRIFFINBOZEMAN, MT 59715JACOB FARWELL(406) 582-0573jacob.farwell@northwestern.comCITYENGINEERINGCITY OF BOZEMANENGINEERING DIVISION20 EAST OLIVE STREETBOZEMAN, MT 59715LANCE LEHIGH(406) 582-2284llehigh@bozeman.netCITY PLANNING& ZONINGCITY OF BOZEMANPLANNING DEPARTMENTNAKEISHA LYON(406) 582-2963nlyon@bozeman.netWATER &SANITARY SEWERCITY OF BOZEMANWATER & SEWER DIVISION121 NORTH ROUSE AVENUEBOZEMAN, MT 59715NICK PERICICH(SUPERINTENDENT)(406) 582-3200pericich@bozeman.netENGINEER OFCONTENTMORRISON-MAIERLE, INC.2880 TECHNOLOGY BLVD WPO BOX 1113BOZEMAN, MT 59771-1113JAMES NICKELSON,PE(406) 587-0721jnickelson@m-m.netENVIRONMENTALMORRISON-MAIERLE, INC.2880 TECHNOLOGY BLVD WPO BOX 1113BOZEMAN, MT 59771-1113CHRISTINE PEARCY(406) 587-0721cpearcy@m-m.net20 EAST OLIVE STREETBOZEMAN, MT 59715PROJECTARCHITECTJDS Architects719 W MENDENHALL STREETBOZEMAN, MT 59715JESSE SOBREPENA(406) 556-8080jesse@jdsarchitectsbozeman.comOWNER8FC, LLCPO BOX 11388BOZEMAN, MT 59719PATRICK EIBS(406) 539-1366peibsk9@yahoo.comPLANNERINTRINSIK106 EAST BABCOCK STREET, ST 1ABOZEMAN, MT 59715TYLER STEINWAY(406) 426-9568tsteinway@intrinsikarchitecture.comREPRESENTATIVEKILDAY & STRATTON2880 TECHNOLOGY BLVD WSUITE 271BOZEMAN, MT 59771-1113GREG STRATTON(406) 599-5603greg@kildaystratton.com