Loading...
HomeMy WebLinkAbout034 A201 18PLEX SECOND FLOOR PLANW/D W/D WH WH DN UP UP REF.REF.DW DW W/D W/D WH WHREF.REF.DW DWREF.REF.DW DW W/DREF.REF.WH WHW/DUP DN DN DNUP 1 A301 1 A300 2 A300 2 A301 174 SF M. BEDROOM 201 BEDROOM 202 BATH 203 M. BATH 204 LIVING ROOM 205 KITCHEN 206 BEDROOM 207 M. BEDROOM 208 BATH 209 M. BATH 210 KITCHEN 211 LIVING ROOM 212 LIVING ROOM 213 KITCHEN 214 M. BATH 215 BATH 216 M. BEDROOM 217 BEDROOM 218 KITCHEN 219 LIVING ROOM 220 BATH 221 M. BATH 222 BEDROOM 223 M. BEDROOM 224 1 A501 R&SSHLVS R&S R&S R&SR&S6' - 9"6' - 6"6' - 5"6' - 1 1/2"6' - 9 1/2"6' - 9"4' - 0"26' - 0"26' - 0"4' - 0"60' - 0"5' - 3 3/4"5' - 8 1/4"5' - 9"6' - 3"2' - 1"5' - 9 1/4"4' - 8 1/4"2' - 11 1/2" 1' - 6"11' - 0"12' - 0"15' - 6" 40' - 0" 5' - 9 3/4"6' - 8 1/4"6' - 0"5' - 9 1/4"4' - 8 1/4"2' - 11 1/2" 12' - 6"12' - 0"15' - 6"60' - 0"5' - 0"2' - 0"3' - 11 1/2"16' - 4"3' - 0"2' - 5 3/4"2' - 9 1/4"3' - 2"16' - 4"3' - 11 1/2"2' - 0"5' - 0"1' - 0"8' - 9 1/2"3' - 5 1/2"3' - 9"5' - 5 3/4"3' - 9"3' - 2 3/4"5' - 6 1/2"3' - 5 1/2"3' - 9"4' - 3 1/2"4' - 0 1/2"1' - 0"10' - 8"3' - 10"4' - 2 1/2"3' - 10" 3' - 9"4' - 3 1/2" 12' - 1 1/2"2' - 6 1/2"5' - 4 3/4"1' - 2 3/4"11' - 10"2' - 8"3' - 9" 12' - 7"2' - 6 1/2"6' - 7 1/2"2' - 9"4' - 0 1/8"7' - 8"3' - 4 3/8" STOR. 227 STOR. 225 STOR. 226 STOR. 228 DECK DECK DECKDECKR&SR&SR&S R&S R&SSHLVS SHLVS SHLVS R&S R&S R&S R&SR&SR&SR&SR&SR&S R&S UNIT 7 UNIT 8 UNIT 11 UNIT 12 ELEC. F.P. ELEC. F.P. ELEC. F.P. ELEC. F.P. 2 A501 B C A B D A E F F E 1 A500 2 A500 3' - 5 1/2"1,179 S.F. 1,058 S.F. 1,079 S.F. 1,058 S.F. 200 201202203 204 205 206 207208209210 211 212213 214 215216218217219 220221 222223224225W2 3' - 6"5' - 10 7/8"5' - 11 3/8"3' - 6"11' - 1"2' - 6 1/2"6' - 7 1/2"2' - 9"4' - 0 1/8"7' - 8"3' - 9 7/8" 12' - 2"3' - 10"4' - 2 1/2"3' - 10" PROVIDE FIRE EXTINGUISHER ON EACH LANDING, MIN. SIZE 2A:10BC, HUNG NO HIGHER THAN 48" OFF FLOOR, TYP. A204 1 ELECTRIC WATER HEATER PROVIDE 1-HOUR WALL AT ALL STORAGE UNIT COMMON WALLS. PROVIDE 5/8" TYPE X ON EA. SIDE OF FRAMING, W/ MIN. FIRE TAPE FINISH PROVIDE 20 MIN. RATED DOORS AT ALL STORAGE & FIRE RISER ROOMS 36"X48" ROLL-IN SHOWER ELEC. PANEL ELEC. PANEL PROVIDE GRAB BAR BLOCKING 36"X48" ROLL-IN SHOWER PROVIDE 20 MIN. RATED DOORS AT ALL STORAGE & FIRE RISER ROOMS UNIT 9 UNIT 10 667 S.F. 677 S.F. 12' - 0"12' - 0" 24' - 0"3' - 0"2' - 5 3/4"2' - 9 1/4"3' - 2"20' - 3 1/2"2' - 0"5' - 0"9' - 7 3/4"2' - 8"3' - 5 1/4" 2' - 8 1/4"5' - 6 3/4"9' - 7 3/4"2' - 8"3' - 5 1/4" 7' - 11 1/2"3' - 10 1/2" 12' - 0"12' - 0" 24' - 0" 2' - 1 1/8"4' - 6"5' - 4 7/8"12' - 8 1/8"4' - 2"3' - 11"6' - 8 7/8"2' - 9 7/8"2' - 9 7/8"6' - 4 7/8"3' - 11"4' - 2"12' - 6 5/8"R&SR&SR&S5' - 11 3/4"6' - 0 1/4"2' - 1 1/4"4' - 6"5' - 4 3/4" 7' - 11 1/2"3' - 10 1/2" R&S R&SR&S3' - 0"SHLVS SHLVS 3' - 9 1/2"4' - 5 5/8"2' - 3 3/8"3' - 5 3/4"6' - 0"3' - 11 3/4" 3' - 9 1/2"4' - 5 1/2"2' - 3 1/2"3' - 4 5/8"6' - 0"4' - 0 7/8"3' - 6"5' - 11 3/8"5' - 10 7/8"3' - 6"348 351467 468 469 470 478477452 456 476454453 457 A K G G 381 385 E B C A350450 459 A K G G 383 379E 337352342 338 336 403353355354340341 F A D B 388346 343345 349 344347 F 339 455 6' - 9"6' - 6"6' - 5"6' - 1 1/2"6' - 9 1/2"6' - 9"4' - 0"26' - 0"26' - 0"4' - 0"60' - 0"5' - 9 3/4"5' - 2 1/4"5' - 9"6' - 3"2' - 1"5' - 9 1/4"4' - 8 1/4"2' - 8 3/4" 1' - 6"11' - 0"12' - 0"15' - 3 1/4" 39' - 9 1/4" 6' - 3 3/4"6' - 2 1/4"6' - 0"8' - 1"5' - 9 1/4"4' - 8 1/4"2' - 11 1/2" 12' - 6"12' - 0"15' - 6"5' - 0"2' - 0"3' - 11 1/2"16' - 4"3' - 0"2' - 5 3/4"2' - 9 1/4"3' - 2"16' - 4"3' - 11 1/2"2' - 0"5' - 0"1' - 0"8' - 9 1/2"3' - 5 1/2"3' - 10 3/4"5' - 4"3' - 9"3' - 2 3/4"5' - 6 1/2"3' - 5 1/2"3' - 9"4' - 8 1/2"3' - 7 1/2"1' - 0"10' - 8"3' - 10"4' - 2 1/2"3' - 10" 3' - 8 1/2"4' - 4" 12' - 1 1/2"2' - 6 1/2"5' - 4 1/8"1' - 3 3/8"11' - 10"2' - 8"3' - 9" 12' - 7"2' - 10 5/8"6' - 3 3/8"2' - 9"3' - 6"7' - 8"3' - 10 1/2"3' - 5 1/2"3' - 6"5' - 10 7/8"5' - 11 3/8"3' - 6"11' - 1"2' - 10 5/8"6' - 3 3/8"2' - 9"3' - 6"7' - 8"4' - 4" 12' - 2"3' - 10"4' - 2 1/2"3' - 10"5' - 0"2' - 0"20' - 3 1/2"10' - 0"40' - 0"40' - 0"10' - 0" 6' - 0"2' - 1" 5' - 11 15/16"6' - 0 1/16" 4436' - 4"6' - 4"G 6' - 4"6' - 4"G BEDROOM 137 LIVING ROOM 138 BATH 139 KITCHEN 140 BEDROOM 141 LIVING ROOM 142 BATH 143 KITCHEN 144 DECK 124' - 0"2' - 9 7/8"2' - 9 7/8"2' - 9 7/8"2' - 9 7/8"FLOOR AREAS FIRST FLOOR 5,618 S.F. SECOND FLOOR 5,618 S.F. THIRD FLOOR 5,618 S.F. TOTAL 16,854 S.F. UNIT AREAS UNIT 7 1,079 S.F. UNIT 8 1,058 S.F. UNIT 9 667 S.F. UNIT 10 677 S.F. UNIT 11 1,079 S.F. UNIT 12 1,058 S.F. 3/16" = 1'-0"A201 1 SECOND FLOOR PLAN NOTE: TOILETS MUST BE WATERSENSE LABELED (1.28 GAL/FLUSH) SHOWERS MUST BE WATERSENSE LABELED (1.5 GPM) CLOTHES WASHERS MUST BE CEE TIER RATED (WATER FACTOR OF 4.0 OR LESS) PENETRATIONS OF FIRE-RESISTIVE WALLS, FLOOR-CEILINGS, AND ROOF-CEILINGS SHALL BE PROTECTED AS REQ'D IN IBC SECTION 714 NOTE: THRESHOLDS IN ROLL-IN TYPE SHOWER COMPARTMENTS SHALL BE 1/2" MAX. IN HEIGHT IN ACCORDANCE WITH SECTION 30 NOTE: OPERABLE PARTS SHALL BE PLACED WITHIN ONE OR MORE OF THE REACH RANGES SPECIFIED IN SECTION 308. ICC A117.1-2017 UNOBSTRUCTED FORWARD REACH IS 48" MAX. ABOVE FLOOR AND 15" MIN. ABOVE FLOOR FOR TYPE UNIT A ONLY: INSTALL FIRE ALARM SYSTEM SMOKE DETECTORS INSTEAD OF RELAY AND 120V NON-FIRE ALARM SYSTEM DETECTORS. REASONING IS THAT FIRE ALARM SYSTEM DETECTORS WILL ACTIVATE FIRE ALARM SYSTEM VISUAL NOTIFICATION DEVICES ON BATTERY BACK-UP POWER. WHEREAS NON-FIRE ALARM SYSTEM DETECTORS ONLY HAVE AUDIBLE NOTIFICATION ON BATTERY BACK-UP POWER. ALL "B" TYPE UNITS SHALL HAVE THE ABILITY TO REPLACE APPLIANCES WITH COMBINATION AUDIBLE AND VISIBLE ALARMS FOR OCCUPANT NOTIFICATION. NWB WEST PARK NEIGHBORHOOD LOT R1A NORTON RANCH SUBDIVISION SITE PLAN REVIEW 05-02-2022 ARCHITECT RETAINS COPYRIGHT TO THESE DRAWINGS.DRAWINGS ARE ONLY FOR USE FOR PROJECT NAMED ONDRAWING SHEET AND MAY NOT BE REPRODUCED OR USEDFOR OTHER PURPOSES WITHOUT WRITTEN PERMISSIONFROM ARCHITECT. 106 EAST BABCOCK STREET SUITE 1A BOZEMAN, MT 59715 PHONE: (406) 582-8988 SHEET NUMBER PROJECT CODE PROJECT ADDRESS SHEET NAME PROJECT NAME DRAWING REVISIONS DRAWING ISSUE DATE DRAWING ISSUED FOR 18-PLEX A201 SECOND FLOOR PLAN