Loading...
HomeMy WebLinkAbout015_L600 IRRIGATION PLANPVC MAINLINE, SCH 40 PVC SYMIRRIGATION LEGENDIRRIGATION CONTROLLERBACKFLOW PREVENTER1.5"WEATHER STATIONCONTROL VALVESEE PLANDRIP CONTROL VALVE1800 SERIES SPRAY WITHR-VAN14 NOZZLE1"SIZE BFWCISOLATION VALVEQUICK COUPLER2"S= OVERHEAD SPRAY OR ROTORD= DRIP IRRIGATION1.5 IRR1.5 IRRIWIRRIGATION WELLNADESCRIPTION1800 SERIES SPRAY WITHR-VAN18 NOZZLE5000 SERIES ROTOR WITHMPR-35 NOZZLEDDDRIP LATERAL LINEPOLYETHYLENE (PE)1"1-D0.4MFGR./MODELLATERAL LINE, SCH 40 PVC1800 SERIES SPRAY WITHR-VAN24 NOZZLENAFEBCO/825YHUNTER/HCCHUNTER/RAIN-CLIKRAINBIRD/PEBNIBCO/TI-8RAINBIRD/44LRCRAINBIRDRAINBIRDRAINBIRDRAINBIRDIRRIGATION SLEEVE,SCH 40 PVCNANANANANANA1.5"4" MIN.ZONE# AND TYPEGPMVALVE SIZE1" MIN. SEE PLANRAINBIRD/XCZ-100-PRB-LC1"SEE IRRIGATION NOTES SHEET L600IRRIGATION NOTES1.POINT OF CONNECTION: CONNECT NEW MAINLINE TO THE EXISTINGWELL IN THE FENCED AREA TO THE NORTH OF THE DETENTIONCENTER. REPLACE THE EXISTING CONTROLLER LOCATED IN THEMECHANICAL ROOM. RUN NEW CONTROL WIRES INTO THEMECHANICAL ROOM THROUGH THE EXISTING SLEEVE IF POSSIBLEOR PROVIDE A NEW SLEEVE INTO THE MECHANICAL ROOM.2.SYSTEM IS DESIGNED TO OPERATE AT 65 PSI AND 30 GPM. THEIRRIGATION WELL PUMP MUST OPERATE WITHIN THE THEALLOWABLE RANGE OF EXEMPT WELLS OF 35GPM AND 10ACRE-FEET PER YEAR.3.ALL VALVE BOXES TO BE STANDARD SIZE OR LARGER4.IRRIGATION MAIN LINE TO BE 1.5" SCH 40 PVC PIPE.5.ALL TREES TO BE IRRIGATED THROUGH DEDICATED BUBBLERSEVENLY DISTRIBUTED AROUND BASE OF TREE WITH FOUR (4)EVENLY SPACED 1 GPH EMITTERS.6.TREES AND SHRUBS PLACED WITHIN PLANTING BEDS MAY UTILIZEDRIP IRRIGATION ADJUSTED PER INDIVIDUAL PLANT REQS.7.ALL SHRUBS OUTSIDE OF DEDICATED PLANTING BEDS TO HAVEDEDICATED EMITTERS EVENLY DISTRIBUTED AROUND BASE, WITHTWO (2) EVENLY SPACED 1 GPH EMITTERS.8.ALL MIXED SHRUB AND PERENNIAL PLANTINGS TO BE IRRIGATEDWITH DEDICATED DRIP TUBING W/ EMITTERS ADJUSTED PERINDIVIDUAL PLANT REQUIREMENTS.9.LAWN AND SEED AREAS TO BE IRRIGATED WITH SPRAY OR ROTOROVERHEAD IRRIGATION AS INDICATED PER PLAN.10.ALL HEADS MUST ACHIEVE HEAD-TO-HEAD COVERAGE FOR SODAREAS. ALL HEADS MUST ACHIEVE ARC-TO-ARC COVERAGE FORSEED AREAS.11.SYSTEM SHALL UTILIZE WEATHER / MOISTURE MONITOR.12.BACKFLOW ASSEMBLY AND BLOWOUT ASSEMBLY SHALL BELOCATED IN AN APPROVED LOCKING ENCLOSURE, AND IT IS THERESPONSIBILITY OF THE LANDSCAPE CONTRACTOR TOCOORDINATE INSTALLATION PER LOCAL CODES AND ORDINANCES,WITH ARCHITECTURE AND WITH ALL OTHER TRADES.13.DO NOT INSTALL IRRIGATION SYSTEM WHEN OBVIOUSOBSTRUCTIONS OR GRADE CHANGES ARE PRESENT.14.ALL INFORMATION TO BE FIELD VERIFIED BY CONTRACTOR PRIORTO INSTALLATION.15.THE CONTRACTOR SHALL MAINTAIN AN ACCURATE & CURRENT'AS-BUILT' IRRIGATION PLAN ON SITE AT ALL TIMES.16.ALL SPRAY AND ROTOR HEADS WITHIN SOD LAWN AREAS TOPROVIDE A PRECIPITATION RATE OF 0.4-0.8"/HR.**1800 SERIES SPRAY BODIES DESIGNED TO REGULATE PRESSURESAT 40PSI AND 30PSI PER HEAD, HEADS TO BE ADJUSTED TO ACHIEVEPROPER ARC RADIUS.OOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOESESESESESESESES///51.4'BPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPG GG G G G G G G G G G G G G GGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGESESESESESESESESWVGREGREGREGREGREGREGREGREAMUAMUAMUAMUAMUAMUAMUAMUAMUAMUNORNORNORNORNORGRENORNORNORNORGRENOR1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR 1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 I R R 1. 5 I R R 1. 5 I R R 1.5 I R R1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR 1.5 IRR 1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRRDDDDD D D DD D D DDDDDDDDDDDDDDDD DDDDDDDDDDDDDDD DDDDDDD DDDDD D DDDDDDDDDDDDD1"16-D3.571"17-S11.521"18-D1.271.5"19-S23.041"21-D1.11.5"22-S26.671.5"23-S26.311"24-D1.81"25-D0.631.5"26-S22.861"20-S18.991.5"1.25"1.5"1.5"1.25"1.25"1.5"1.5"1.5"1.25"1.25"Project Number:Drawn By:Reviewed By:Approved By:21-311GHUGHUGHUGallatin CountyCourtsIssue:Date06 June 202290% CD Internal Review26 October, 2022ADD-0328 April 2022COB Site Plan Application615 SOUTH 16TH AVENUEBOZEMAN, MONTANA 5971521-311Gallatin CountyGallatin County Commission311 West Main StreetBozeman, MT, 59715Telephone: 406-582-2300ThinkOne Architects101 E Main St. Studio 1Bozeman, MT, 59715T: 406-586-7020ArchitectAndersonMasonDale Architects, P.C.3198 Speer BoulevardDenver, CO 80211T: 303-294-9448Associate ArchitectMorrison-Maierle, Inc.2880 Technology Blvd.Bozeman, MT 59715T: 406-587-0721Civil EngineerMorrison-Maierle, Inc.2880 Technology Blvd.Bozeman, MT 59715T: 406-587-0721Structural EngineerMorrison-Maierle, Inc.2880 Technology Blvd.Bozeman, MT 59715T: 406-587-0721Mechanical EngineerMorrison-Maierle, Inc.2880 Technology Blvd.Bozeman, MT 59715T: 406-587-0721Plumbing EngineerMorrison-Maierle, Inc.2880 Technology Blvd.Bozeman, MT 59715T: 406-587-0721Electrical EngineerDesign 5 Landscape Architecture111 North Tracy AvenueBozeman, MT 59715T: 406-587-4873Landscape ArchitectMorrison-Maierle, Inc.2880 Technology Blvd.Bozeman, MT 59715T: 406-587-0721Fire Protection EngineerMorrison-Maierle, Inc.2880 Technology Blvd.Bozeman, MT 59715T: 406-587-0721Technology EngineerSeal:08 July 2022CDL-600Irrigation Plan2010040N1L6001" = 20'-0"Irrigation Plan