Loading...
HomeMy WebLinkAbout036 - SP129 - APARTMENT EXTERIOR ELEVATIONST.O. SLAB 100' -0" T.O. SUBFLOOR (L2) 114' -4 3/4" T.O. FOOTING 96' -0" 8 115 1361210219 T.O. SUBFLOOR (L3) 125' -0 1/8" T.O. SUBFLOOR (L4) 135' -7 1/2" T.O. PLATE (L4) 144' -10 1/8" 4 73 2 8 3 10 11 88 8 9' - 2 1/2"10' - 7 1/2"10' - 7 1/2"14' - 5"11 11.38.8 1 6 9 T.O. SLAB 100' -0" T.O. SUBFLOOR (L2) 114' -4 3/4" 811 51361210 2 19 T.O. SUBFLOOR (L3) 125' -0 1/8" T.O. SUBFLOOR (L4) 135' -7 1/2" T.O. PLATE (L4) 144' -10 1/8" 47 3 2 8 388 5 111 10 3 9' - 2 1/2"10' - 7 1/2"10' - 7 1/2"14' - 5"11.3 8.8 TRANSPARENCY NORTH FACADE TOTAL FACADE AREA - 4,677 SF TRANSPARENT AREA -802 SF TRANSPARENCY % = 17.1% *PER B.M.C. / TABLE 38.510.030.C NORTH ELEVATION -TRANSPARENCY DIAGRAM FACADE TRANSPARENCY FROM 30" TO 10' -0" TRANSPARENCY LEVEL ONE -FROM (30") TO (10') TOTAL FACADE AREA - 934 SF TRANSPARENT AREA -302 SF TRANSPARENCY % = 32.3% *PER B.M.C. / TABLE 38.510.030.C TRANSPARENCY SOUTH FACADE TOTAL FACADE AREA - 4,689 SF TRANSPARENT AREA -389 SF TRANSPARENCY % = 8.3% *PER B.M.C. / TABLE 38.510.030.C SOUTH ELEVATION -TRANSPARENCY DIAGRAM FACADE TRANSPARENCY FROM 30" TO 10' -0" TRANSPARENCY LEVEL ONE -FROM (30") TO (10') TOTAL FACADE AREA - 930 SF TRANSPARENT AREA -40 SF TRANSPARENCY % = 4.3% *PER B.M.C. / TABLE 38.510.030.C SIDING LEGEND HORIZONTAL BOX RIB CORRUGATED SIDING METAL SIDING, 22 GA. 7/8" CORRUGATED, BRIDGER STEEL "GALVALUME" METAL SIDING, 22 GA. 7/8" CORRUGATED, BRIDGER STEEL "VINTAGE" FIBER CEMENT PANEL, SMOOTH, PAINTED BLACK 1"x6" NATURAL WOOD SHIPLAP SIDING W/ NICKEL GAP VINYL WINDOWS & DOORS FRAME FINISH: BLACK GLASS: CLEAR STOREFRONT GLAZING SYSTEM FRAME FINISH: BLACK GLASS: CLEAR CMU BLOCK VENEER C CHANNEL STEEL AWNING FINISH: BLACK PAINT STEEL FINISH: BLACK PAINT 1 2 3 4 5 6 7 8 9 10 11 METAL SIDING, 22 GA. 7/8" CORRUGATED, BRIDGER STEEL "WHITE" SHEET NUMBER PROJECT CODE PROJECT ADDRESS ARCHITECT RETAINS COPYRIGHT TO THESE DRAWINGS. DRAWINGS ARE ONLY FOR USE FOR PROJECT NAMED ON DRAWING SHEET AND MAY NOT BE REPRODUCED OR USED FOR OTHER PURPOSES WITHOUT WRITTEN PERMISSION FROM ARCHITECT. PRELIMINARY NOT FOR CONSTRUCTION 106 EAST BABCOCK STREET SUITE 1A BOZEMAN, MT 59715 SHEET NAME PROJECT NAME DRAWING REVISIONS DRAWING ISSUE DATE DRAWING ISSUED FOR PHONE: (406) 582-8988 BIM 360://WPM - Wentworth/WPM - MIXED USE 42 UNIT.rvt9/16/2022 9:45:47 AMSP129 WPM Wentworth Mixed Use Multi-Family EXTERIOR ELEVATIONS SOUTH UNIVERSITY DISTRICT SUB. 2 SITE PLAN REVIEW 2022-06-23 1/8" = 1'-0"SP129 1 NORTH ELEVATION 1/8" = 1'-0"SP129 2 SOUTH ELEVATION 1 1 1 1 1 RC #01 2022-09-16