HomeMy WebLinkAbout013 A2.1.1 LEVEL 1 DIMENSION PLAN5 64 C.1 C B 3 A5.1.1 1 A5.1.1 1 A D 7 E A5.2.1 16 A5.1.1 11 A5.1.1 11 NOT IN SCOPE WAITING 101 STAFF BREAK 124 CONSULT 123 CONSULT 122 CORRIDOR 132 PUBLIC TOILET 125 IT 121 MECH 120B LAB 126 STAFF TOILET 119 LAUNDRY 117 CONSULT 102 COMFORT SAFE ROOM 103 PATIENT 104 PATIENT 105 PATIENT 106 PATIENT 107 STORAGE 108 SALLY PORT 109 RESTRAINT ROOM 110 TOILET 111 TOILET 112 VESTIBULE 116 INVOL. PATIENT 113 INVOL. PATIENT 114 CATERING/FOOD PREP 115 CLEAN LINEN 118 DAY ROOM / DINING 129 CORRIDOR 130 CORRIDOR 131 ENV 120A EXISTING CRAWL SPACE ACCESS 101.0102.0 124.0102.1103.0E E E E E 109.0107.0 106.0 105.0111.0112.0113.0114.0115.0117A.0 119.0 121.0122.0125.0 128A.0 127.0126.0128.1132.0 104.0 108.0 130.0 109.1110.0 120.0131.0118.0116.0MEDS 127 CLINIC STATION 128 112B.0112A.0 117.0 SOIL HOLD 117A WP-2 WP-2 TOILET 112A TOILET 112B A-6A2 A-6A2 A-3A1 A-3A1 A-3A1 A-6A1 ATS A-3A1A-3A1 WALL MOUNTED TE CABCLEAR 1' - 5 3/8" WORKSTATION ADAPTABLE ADA WORK AREA 128A WP-2 WP-2 A-3A1 A-6A2 A-6A2 A-3A1 A-3A1 A-3A1 A-3A1 A-6A1 A-3A1 A-3A1 WP-2 A-3A1 A-3A1 A-3A1 A-3 A-3A1 A-3A1 A-3A1 A-3A1 A-3 A-3 A-3 A-6 A-3 A-3 A-3 A-3 A-3 A-3 A-3 A-6 A-3 A-3 A-3 A-3 A-3 A-3 A-6 A-3 A-3 A-3 B-3 B-3 B-3 A-3 A-3 A-3 A-3 A-3 A-3 A-3 A-3 A-6 A-3 A-3 A-6 B-3 A-3 A-3 A-3 A-3 A-6 A-3 A-3 A-3 A-3 A-3 4' - 7 1/2"4' - 6 5/8"135° 1 3 5 °135°135° 135° 7' - 9" R.O.4' - 11 1/2"8"4' - 9"5"5"2' - 9 3/8"8"7' - 4"2' - 2"1' - 11"4' - 2 3/4"2' - 4 7/8"2' - 8 1/4"8"5' - 11 1/2"1' - 7 1/2"10' - 9 3/8" R.O.10' - 4 1/2" R.O.9' - 3 3/4" R.O.IN EXISTING OPENING 9' - 4 1/2" R.O. B-1 WP-2 1' - 7 7/8"3' - 10 1/8"5' - 0"10"1' - 6"10' - 7 3/4"12' - 9 1/2" 4' - 4 1/4" 1' - 2 1/4" 3' - 3"5' - 9 5/8"6 3/8"11' - 2 5/8" 1 1/2"2' - 8 3/4" A-3 A-6 A-3 4' - 5"B-3A-3 9' - 2"2' - 6"3' - 0"A-3 B-2P4' - 9"1' - 5 1/2"3' - 9 3/4" 1 1/8"4 7/8" 5' - 2 7/8"12' - 11" A-3 A-6 A-3 A-3 A-34 1/8"3' - 1"5' - 3 1/4"6 1/8"4' - 11 5/8"1' - 7"4' - 1 3/4"10 7/8"7' - 3"4' - 10 5/8"7 3/4"4' - 5 1/4"1' - 5 3/8"09-08 128.05' - 7 3/4"7' - 2"2' - 9 1/2"1' - 1 1/2" 1' - 1 5/8"6"45°A-3 A3.3.1 10 A3.3.1 4 A3.3.1 15 A3.3.1 12 A3.3.1 3 A3.3.1 16 1A-3 1A-3 1B-2 PHASE 1 1' - 7 5/8"8' - 5"9' - 7 1/2"7' - 11 1/2"2' - 4"B-3 B-3 B-3 B-3 SCALE: 1/4" = 1'-0" 4'3'2'1'4'8'0' NORTH3' - 8 3/8"5' - 3 1/4"4' - 11 5/8"6 1/8"5' - 3 1/4"3' - 4 5/8"8' - 0 7/8"1' - 6 3/8"W-06 5 EQUAL SPACES 14' - 0"3"10°10°10° 1 0° 1 0° 10° 10° 10° 10°5' - 0"2' - 0"2' - 0"2' - 0"2' - 0"1' - 2 1/2"9 1/2"2' - 0"10' - 5 5/8" (OD STUD)6' - 0 1/8" W-02 5' - 6"3"1' - 5 7/8"3' - 6" W-03 W-01 WORK POINT OF CURVED WALL 1' - 6"3' - 0 3/8" W-07 W-04 W-05 4 1/2"7' - 9" R.O. B-3 09-17 09-17 09-17 09-17 B-3 124.1 117.1 B-3 4' - 10 1/8"1' - 8 3/8"1 1/2"5' - 4 1/2"3' - 0"8' - 9 7/8"12' - 5"6' - 1 1/2"4' - 9"4' - 8"4 7/8" 1' - 6 1/8"6' - 8 3/4"5' - 9 5/8"5 3/8"4' - 9"4' - 7 3/4"5"8 1/2"A3.3.1 2 7' - 9 3/8"1' - 10"4' - 2 3/8"123.0A3.3.1 1 09-17116.17"5"A3.3.1 16 A-3A1 A-3A1 5' MIN CLEAR SIM. OPP. SIDE 09-23 09-23 09-23 09-23 09-2309-23 A5.2.1 15 A5.2.1 13 A-3 08-03 08-03 SOFFIT ABOVE SOFFIT ABOVE 5' - 0 3/8"1. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. ALL INFORMATION REGARDING EXISTING CONDITIONS IS BASED UPON OWNER-SUPPLIED DOCUMENTS AND MAY NOT PRECISELY REFLECT FIELD CONDITIONS. 2. THE CONTRACTOR SHALL NOT CONSIDER CONSTRUCTION NOTES TO BE ALL-INCLUSIVE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSPECT AND ASSESS EACH AREA AND TO FULFILL THE INTENT OF THE CONTRACT DOCUMENTS. CONTRACTOR SHALL COORDINATE ARCHITECTURAL CONSTRUCTION DRAWING AND NOTES WITH CIVIL, STRUCTURAL AND MECHANICAL, ELECTRICAL & PLUMBING NOTES AND DRAWINGS. 3. FIELD VERIFY ALL DIMENSIONS. DO NOT SCALE DRAWINGS. 4. ALL FINISHES AND MATERIALS SHALL BE PROPERLY INTEGRATED TO ENSURE A UNIFORM APPEARANCE AND SEAMLESS TRANSITION. 5. PROVIDE ALL BLOCKING FOR MILLWORK, GRAB BARS, MONITORS, CRASH RAILS AND ANY AND ALL WALL MOUNTED EQUIPMENT OR ACCESSORIES; COORDINATE LOCATIONS. 6. ALL DIMENSIONS ARE FROM STRUCTURAL OR UNFINISHED FACE OF STUD, UNLESS OTHERWISE NOTED. 7. GENERAL CONTRACTOR SHALL COORDINATE ALL ASPECTS OF THE BUILDING CONSTRUCTION. 8. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND REPAIR ALL INCONSISTENCIES IN FLOOR ELEVATIONS. 9. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO PROVIDE SUITABLE SUBSTRATE FOR FINISHES. 10. U.L. ASSEMBLIES DESCRIBED ARE FOR REFERENCE ONLY. THE GENERAL CONTRACTOR SHALL COORDINATE AND VERIFY THE INSTALLATION OF THE DESCRIBED SYSTEM(S) . 11. 12. REFER TO DOOR AND FRAME SCHEDULE FOR DOORS REQUIRING ADA ACCESS CONTROL. 13. LOCATE THE HINGE SIDE JAMB OF DOORS 4" FROM ADJACENT PERPENDICULAR WALL, UNLESS NOTED OTHERWISE. 14. PROVIDE ACOUSTICAL SEALANT AROUND WALL EDGES, TOP AND BOTTOM, AND PENETRATIONS, AND INSTALL PUTTY PADS AROUND ELECTRICAL BOXES WHERE PARTITION CONTAINS ACOUSTICAL INSULATION. 15. REFER TO SPECIFICATIONS FOR CODE REQUIRED SIGNAGE. PROVIDE ADDITIONAL SIGNAGE AS MAY BE REQUIRED BY REQUEST OF THE FIRE MARSHAL AND/OR BUILDING CODE OFFICIAL. FLOOR PLAN NOTES 1-HOUR FIRE RATED PARTITION NON-RATED SECURITY PARTITION EXTEND FROM FLOOR TO UNDERSIDE OF STRUCTURE WITH GYPSUM BOARD BOTH SIDES OF PARTION WALL PARTITION LEGEND EXISTING NON-RATED WALL CONVERTED TO UL DES NO. 465, 1-HOUR FIRE RATED PARTITION issue date project # phasesheet projectownerrevision dateaddress PERMIT SET8/29/2022 5:31:17 PMA2.1.1 08/29/2022LEVEL 1 DIMENSION PLAN22006.00 PERMIT SETSPANISH PEAKSCONNECTIONS HEALTH SOLUTIONS120 19TH AVE. SUITE HBOZEMAN, MONTANA 597181/4" = 1'-0"13 LEVEL 1 - DIMENSION KEY NOTES 08-03 1/2" MINIMUM THICKNESS POLYCARBONATE WINDOW PROTECTION. PROVIDE 2" WIDERED THAN EDGE AT PERIMETER OF OPENING; MECHANICALLY FASTENED WITH TEMPER PROOF FASTENERS; AT 8" O.C. AT PERIMETER; INSTALL SAND BLASTED FILM-3 IN FULL POLYCARBONATE MATERIAL FACING THE STOREFRONT 09-08 ALIGN FINISHED GYPSUM BOARD SURFACES 09-17 MAINTAIN ACOUSTICAL WALLS A HIGH PRIORITY AND UNINTERRUPTED ENVELOPE 09-23 INSTALL GBI-1 OVER EXISTING LAYER OF GYPSUM BOARD, AT EXTERIOR WALL