HomeMy WebLinkAbout007 A0.1 L18 Code Plans68'-8"TOTAL EGRESS DISTANCE. TO MAIN LEVEL9 3 '-2 " T O T A L E G R E S S D IS T A N C E . T O M A IN L E V E L B OCCUPANCY: 13OCCUPANTS(FACTOR= 100 GROSS)MEZZANINE1,228 SF NETB.O. REFLECTIVE SURFACEADA LAVATORIESKNEE CLEARANCEMIRRORADA WATER CLOSETADA WATER CLOSETTPHGBGB1GB2 GB1GB248" MAX15" MIN33" - 36"12" MAX42" MIN3' - 0"TPH12" TO CL6" MAX3' - 0"17" -19"ADA COMPLIANT WRAP AT ALL EXPOSED PIPES8" MIN6" MAX17" MIN9" MIN27" MIN2'-9" MIN34" MAX40" MAXT.O. SEAT18"7"-9"39" - 41"39" - 41"GB3HK48" MAXRECEPTACLE15" MIN48" MAXELECTRICAL CONTROLSWALL SWITCHADA DOOR OPERATOR48" MAX15" MIN8"-10"33" - 36"15" MAXHEAD END WALLCONTROL END WALL12" MAXGB 1GB 2GB 324" MIN. LENGHTNOTE: CONTROLS TO BE LOCATED BETWEEN THE BATHTUB RIM AND GRAB BAR, AND BETWEEN THE OPEN SIDE OF THE BATHTUB AND THE CENTERLINE OF THE WIDTH OF THE BATHTUB. PROVIDE LEVER STYLE CONTROLS PER SECTION 309.4.ADA URINAL15" CLR.15" CLR.17" MAX TO RIMREACH HEIGHTSCONTROL WALL1' - 6"3' - 0"3' - 0"1' - 0"36 X 48 CLEAR FLOOR SPACEFOLDING SEAT17"-19" HT18" VERTICAL GRAB BARTWO WALL GRAB BARSHOWER REQUIREMENTSCONTROLS REQUIRED TO BE LOCATED ON CONTROL WALL. LOCATE 15" MAX DISTANCE FROM C.L. OF BENCH.MAX1' - 3" 4" MAXMIN1' - 8"MIN2' - 10"1/2" MAXBENCH -OPPOSITE CONTROL WALL3" MAXHANDHELD SHOWER HEAD1' - 6"ADA DIMENSION GUIDE AND REQUIREMENTS ADA TUBACCESSORIES ABBREVIATIONS:DCSDIAPER CHANGING STATIONDFDRINKING FOUNTAINFECFIRE EXTINGUISHER CABINETHDHAND DRYERHKHOOKGBGRAB BARMMIRRORPTDPAPER TOWEL DISPENSERSCDSEAT COVER DISPENSERSDSOAP DISPENSERSNDSANITARY NAPKIN DISPENSERSNRSANITARY NAPKIN RECEPTACLETPHTOILET PAPER HOLDERWRWASTE RECEPTACLENOTE: THIS IS FOR GENERAL REFERENCE ONLY OF TYPICAL MOUNTING HEIGHTS.VERIFY ALL MOUNTING LOCATIONS IN FIELD TO MEET THESE GUIDELINES PRIOR TO INSTALLATION.THIS IS A GENERAL REVIEW OF UNIVERSAL DESIGN STANDARDS FOR COMPLIANCE WITH THE ADA GUIDELINES AND IS INTENDED TO BE APPLIED TO MEET THE BARRIER FREE DESIGN STANDARDS. THIS INTENDED TO BE USED TO PROVIDE ADEQUATE ACCESS BY MEANS OF UNIVERSAL DESIGN AND ADA REQUIREMENTS. CAREFUL CONSIDERATION SHOULD BE USED WHILE APPLYING THESE GUIDELINES DURING CONSTRUCTION.1. PROVIDE 1/2" PLYWOOD AT ALL SHOWERS AND WATER CLOSETS FOR GRAB BAR MOUNTING.2. PROVIDE FLUSH THRESHOLDS OR ADA STANDARD SADDLE THRESHOLDS AT ALL EXTERIOR DOORS.3. PROVIDE FLUSH TRANSITION BETWEEN BATHROOM FLOOR AND SHOWER.4. PROVIDE PERMANENT FOLD DOWN SEAT WITH BATHTUBS AND GRAB BARS PER SECTION 607.4.5. DOORS TO HAVE CLEAR WIDTH OF 32". PROVIDE LEVER HANDLES AT ALL SWING DOORS.6. HALLS TO BE 36" MIN. CLEAR WIDTH. ALCOVES SHALL BE 36" WIDE MIN. WHERE DEPTH IS EXCEEDS 24 INCHES.7. PROVIDE ROCKER SWITCHES FOR ALL FIXTURES. PROVIDE ADEQUATE LIGHTING LEVELS FOR VISION IMPAIRED.8. FLOORS AND GROUND SURFACES SHALL BE STABLE, FIRM, AND SLIP RESISTANT. CARPET SHALL HAVE A MINIMUM PILE HEIGHT OF 1/2" PER SECTION 3029. GUARD RAIL OPENING SHALL NOT ALLOW PASSAGE OF A 1/2" SPHERE.10. INSTALL FLOOR MATERIALS TO BE NO GREATER THAN A 1/4" LEVEL CHANGE PER SECTION 303 OR PROVIDE BEVELED EDGE WITH NOT GREATER THAN 1:2 SLOPE WITH A MAX HEIGHT OF 1/2". 11. CHANGES IN LEVEL GREATER THAN 1/2" SHALL MEET RAMP REQUIREMENTS PER SECTION 405AND 406. RAMPS WITH SLOPE 1:48 ARE PERMITTED. SEE SECTION REQUIREMENTS FOR RAMPS LENGTHS AT 1:20 OR 1:12.12. NO CHANGES IN LEVEL AT TURN AROUND SPACE IN BATHROOMS AND KITCHENS.13. PROVIDE TURNING RADIUS OF 5' DIA. OR PER T SHAPED SPACE PER SECTION 304.14. TYPICAL CLEAR FLOOR SPACE TO BE 30" X 48".15. PROTRUDING OBJECTS GREATER THAN 27" AND LESS THAN 80" FROM FINISH FLOOR SHALL NOT EXCEED 4" FROM THE ADJACENT VERTICAL SURFACE.16. SEE REACH RANGES PER SECTION 308 FOR FRONT REACH OF 44" AND SIDE REACH OF 48" REQUIREMENTS.17. DOORS SHALL HAVE CLEAR WIDTH OF 32" AND CLEAR APPROACH DISTANCES. PROVIDE 18" AT ALL FRONT APPROACH DOORS FROM PULL SIDE, AND 12" FROM PUSH SIDE. SEE SECTION 404.18. PROVIDE 48" BETWEEN DOORS IN A SERIES PER SECTION 404.19. SLOPE GARAGE FLOOR FOR POSITIVE DRAINAGE FROM RESIDENCE ENTRY.20. STAIRWAYS TO CONFORM WITH SECTION 504.21. GRAB BARS SHALL COMPLY WITH SECTION 604.22. LAUNDRY MACHINES SHALL HAVE A MAXIMUM HT. OF 36" TO THE OPERABLE DOOR PER SECTION 611.23. PASS THROUGH KITCHENS TO HAVE 40" CLEAR WIDTH AND U SHAPED KITCHENS TO PROVIDE 60" CLEAR WIDTH.GENERAL UNIVERSAL DESIGN NOTES (PER ADA GUIDELINES 2010):CODE SUMMARYUSE: (B) BUSINESS & (S-1) STORAGETYPE: V-B NON-RATED CONSTRUCTIONFIRE SPRINKLER: NOTHE FOLLOWING IS A SUMMARY OF CODE-RELATED ISSUES FOR THIS PROJECT PER IBC 2021:FLOOR AREA (GROSS):MAIN LEVEL 8,544 SF OFFICE/ADMIN. & WAREHOUSEUPPER LEVEL (MEZZANINE)1,228 SF OFFICE/ADMIN.BUILDING FOOTPRINT: 8,544 SF ALLOWABLE PER IBC TABLE 503 = 9,000 SFTOTAL EXIT DISTANCE PERMITTED: 200' (NON SPRINKLER) (100' COMMON PATH)NOTE: ALL NEW CORRIDOR WALLS TO BE 1-HR. FIRE-RATED ASSEMBLIES PER IBC TABLE 1020.1ALL DOORS WITHIN NEW CORRIDORS TO BE 20-MIN. FIRE-RATED PER IBC TABLE 716.5ALL WINDOWS WITHIN NEW CORRIDORS TO BE 45-MIN. FIRE-RATED PER IBC TABLE 716.6EXTGR.EXTINGUISHER REQUIREMENTS4A:80-B:C FIRE EXTINGUISHERS LOCATED AT A MAXIMUM TRAVELDISTANCE OF 50' PER PLAN TO HANDLE CLASS A AND B FIRES, ASMARKED BY 'EXTGR.' LOCATIONSIF COMBUSTIBLE METALS WILL BE UTILIZED IN THE LAB, PROVIDE DRY POWDER FIRE EXTINGUISHERS IN EACH LAB WITHIN 50' TRAVEL DISTANCE OF LAB WORK, AS MARKED BY 'EXTGR. D' LOCATIONSNOTE: COMPLIANCE FOR COMBUSTIBLES AND VENTING IS THE RESPONSIBILITY OF THE CONTRACTOR AND SUBCONTRACTOR AND THE USE OF THESE DOCUMENTS CERTIFIES USERS UNDERSTAND REQUIREMENTS FOR PROVIDING COMPLIANCE WITH ALL CODES. ANY DISCREPANCIES IN THE DESIGN SHALL BE IDENTIFIED TO THE ARCHITECT PRIOR TO CONSTRUCTION. ALL ASSEMBLIES, MECHANICAL DESIGN, AND ELECTRICAL REQUIREMENTS ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.CODE PLAN LEGENDTRAVEL DISTANCEMAXIMUM DISTANCE POINT TO EXITEXIT SIGN -ILLUMINATEEXIT2A10 MULTI FIRE EXTINGUISHER4TOTAL EXIT OCCUPANCY1-HOUR RATED WALL ASSEMBLYEXITEXITEXIT14'-8" + 53'-5"= 68'-2"TOTAL EGRESS DISTANCE200'-0" ALLOWED PER TABLE 1017.262'-0"TOTAL EGRESS DISTANCE71'-8"TOTAL EGRESS DISTANCE 200'-0" ALLOWED PER TABLE 1017.267'-2"TOTAL EGRESS DISTANCE 39'-8"TOTAL EGRESS DISTANCE 56'-6"TOTAL EGRESS DISTANCE 56'-6"TOTAL EGRESS DISTANCE 1818WAREHOUSE5,013 SFS-1 OCCUPANCY : 10 OCCUPANTS(FACTOR= 500 GROSS)B OCCUPANCY: 23 OCCUPANTS(FACTOR= 100 GROSS)OFFICE/ADMIN 2,304 SF24EXTGR.EXTGR.BRADLEY EYEWASH STATION -WALL MOUNT -S19_220BF2A10 MULTI FIRE EXTINGUISHERBRADLEY EYEWASH STATION WALL MOUNT -S19_220BFFIRE EXTINGUISHERWALL MOUNT -4A:80-B:C 48'-4"TOTALEGRESS DISTANCE71'-3"TOTALEGRESS DISTANCE200'-0" ALLOWED PER TABLE 1017.269'-8"TOTAL EGRESS DISTANCE69'-10"TOTAL EGRESS DISTANCEB OCCUPANCY: 13 OCCUPANTS(FACTOR= 100 GROSS)OFFICE/ADMIN1,228 SFNOTE:UNLESS A SPRINKLER SYSTEM IS INSTALLED NO HIGH-PILED STORAGE OF COMBUSTIBLE MATERIALS IN CLOSELY PACKED PILES OR COMBUSTIBLE MATERIALS ON PALLETS, IN RACKS OR ON SHELVES WHERE THE TOP OF STORAGE IS GREATER THAN 12 FEET (3658 MM) IN HEIGHT. HIGH-PILED COMBUSTIBLE STORAGE ALSO INCLUDES CERTAIN HIGH-HAZARD COMMODITIES, SUCH AS RUBBER TIRES, GROUP A PLASTICS, FLAMMABLE LIQUIDS, IDLE PALLETS AND SIMILAR COMMODITIES, WHERE THE TOP OF STORAGE IS GREATER THAN 6 FEET (1829 MM) IN HEIGHTDRAWING NUMBER:PHASE:DATE:DRAWING TITLE:PROJECT NUMBER:DRAWN BY / CHECKED BY:REVISIONS:0"1"2"9/27/2022 5:17:59 PMA0.1CODE PLANS20-39NELSONMEADOWS9.27.2022ML CCRCD3555 ROYALWOLF WAY,BOZEMAN, MT1/8" = 1'-0"MEZZANINE - CODE PLAN21/8" = 1'-0"MAIN LEVEL - CODE PLAN1FLOOR AREA TABLE BY USE TYPEUSE LEVEL AREA COMMENTSOFFICE/ADMIN. MAIN LEVEL 3532 SFOFFICE/ADMIN. T.O. FLOOR AT MEZZ. 1228 SFWAREHOUSE MAIN LEVEL 5013 SF9772 SFIIIIINO. DESCRIPTION DATE1 Revision 1: SPPrescreen1/28/223 Revision 3: SP 8/9/224 Revision 3: SP 9/27/22