HomeMy WebLinkAbout098 IR2.2 - IRRIGATION DETAILS - 20211027Site Plan Submittal Date:NOVEMBER 12, 2021SITE PLAN SUBMITTALTHE HOMESTEAD AT BUFFALO RUN5400 FOWLER LANES23, T02 S, R05 E, N2SW4SW4, CITY OF BOZEMAN, GALLATIN COUNTY, MONTANA.Revision 1 Date:MAY 10, 2022FINISH GRADERECTANGULAR VALVE BOX WITHEXTENSION - BRAND "MV" INTOVALVE BOX LID. REFER TOTECHNICAL SPECIFICATIONS.SLIPxMIPT SCH. 40 PVC ADAPTER (2)PRESSURE MAINLINE34" CRUSHED GRAVEL SUMP - 2 C.F.ELECTRIC MASTER CONTROLVALVEMASTER VALVE1324V - Small - TypicalNO FITTINGS INCLUDING REDUCER BUSHINGS, TEES,ELLS, ETC, SHALL BE INSTALLED WITHIN "METERRUN" DISTANCE. DIAMETER OF FLOW SENSOR TEEAND "METER RUN" PIPING SHALL BE EQUAL. NOREDUCER BUSHINGS, ADAPTERS, ETC. SHALL BEINSTALLED WITHIN FLOW SENSOR TEE.DATA CABLE SPLICE CONSISTING OFWIRE NUTS AND PREFORMED SUPERSERVISEAL SPLICE KIT.FINISH GRADERECTANGULAR VALVE BOX WITH EXTENSIONSAS REQUIRED. BRAND "FS" INTO VALVE BOXLID. REFER TO TECHNICAL TO TECHNICALSPECIFICATIONS SPECIFICATIONS. VALVE BOXSHALL NOT REST DIRECTLY ON FLOW SENSORCABLE.TEE STYLE FLOW SENSOR. REFERTO PLAN & SCHEDULE FOR SIZING,MANUFACTURER, & MODEL.DATA CABLE TO CONTROLLER SENSORINPUTS PER MANUFACTURERRECOMMENDATION. PROVIDE ADDITIONALCABLE WITHIN BOX TO ALLOW REMOVALOF SENSING UNIT FROM BOX FORMAINTENANCE PURPOSES.3/4" GRAVEL SUMP - 2 CU. FT.PVC PRESSURE MAINLINE - REFERTO PLAN FOR DIAMETER.FLOW10x PIPE DIA.5x PIPE DIA.METER RUNFLOW SENSOR14VIA DATA CABLE - TEE STYLE4-6" BODIES: 18"12" BODIES: 24"CONTROL WIRE BUNDLE OR TWOWIRE COMMUNICATION CABLE (PERSPECIFICATIONS)24"SPRAY HEAD LATERALPIPING OR DRIP LINEHEADER.FINISHGRADEROTOR LATERALPIPINGBACKFILL MATERIAL (TYP.)4-6" BODIES: 14"12" BODIES: 18"MAINLINENOTE: REFER TO TECHNICALSPECIFICATIONS FOR MINIMUMTRENCH WIDTHS.1524" MAINLINETRENCHBAROUGH GRADECNOTE:·ALL SLEEVE MATERIAL PER IRRIGATION SCHEDULE, SIZE AS NOTED ONPLAN.·INSTALL SLEEVES IN SIDE-BY-SIDE CONFIGURATION WHERE MULTIPLESLEEVES ARE TO BE INSTALLED. SPACE SLEEVES 4" TO 6" APART. DONOT STACK SLEEVES VERTICALLY.·CONTRACTOR TO COORDINATE WITH FLATWORK INSTALLER TO BRAND A"V" IN SIDEWALK OR CURB AT BOTH ENDS OF SLEEVE CROSSING.·SLEEVING THROUGH OR UNDER RETAINING WALLS, PLANTER WALLS, PONDLINING, OR WATER QUALITY AREAS SHALL BE COORDINATED WITH CIVILWORK AT APPROXIMATE LOCATIONS SHOWN.PAVED SURFACECURB AND GUTTER(IF APPLICABLE)2" PVC PIPE SLEEVE MARKER -INSTALL AT BOTH ENDS OF EACHSLEEVE LOCATION AND EXTEND ATLEAST 3' ABOVE GRADE. SPRAYEXPOSED PORTION OF MARKER WITHGREEN FLUORESCENT PAINT. REMOVEAT FINAL INSTALL.SEAL ENDS OF SLEEVE WITHCLOTH DUCT TAPE (TYPICAL)PVC SLEEVING (TYPICAL)24" MIN.12" MIN.36" MIN.IRRIGATION SLEEVING16TYPICALPLANT SIZEEMITTERFLOW RATEEMITTER QTY. AT MULCHEDBED LOCATIONSEMITTER QTY. AT NATIVESEED LOCATIONS1 - 2 GALLON MATERIAL0.5 GPHONE EACHONE EACH5 GALLON MATERIAL0.5 GPHTWO EACHTWO EACH112" CALIPER TREE1.0 GPHTHREE EACHFOUR EACH2" CALIPER TREE1.0 GPHFOUR EACHSIX EACH212" CALIPER TREE1.0 GPHSIX EACHEIGHT EACH3" CALIPER TREE1.0 GPHEIGHT EACHTEN EACH312" CALIPER TREE1.0 GPHNINE EACHELEVEN EACH4" CALIPER TREE1.0 GPHTEN EACHTWELVE EACH6 FT. CONIFEROUS TREE1.0 GPHFOUR EACHSIX EACH8 FT. CONIFEROUS TREE1.0 GPHSIX EACHNINE EACH10 FT. CONIFEROUS TREE1.0 GPHEIGHT EACHTWELVE EACH12 FT. CONIFEROUS TREE1.0 GPHTEN EACHFOURTEEN EACHNOTES:·INSTALL EMITTERS ON OPPOSING SIDES OF ROOTBALL. THREE OR MORE EMITTERSSHALL BE EQUALLY SPACED AROUND ROOT BALL.·EMITTERS ARE TO BE INSTALLED TO CLEAR SURFACE BY A MINIMUM OF 1" AND AMAXIMUM OF 2".·FLUSH ALL LINES THOROUGHLY, INCLUDING EMITTER MICRO-TUBING PRIOR TOEMITTER INSTALLATION.·IF PLANTING ON A 4:1 SLOPE OR STEEPER, INSTALL BOTH EMITTERS ON UPHILL SIDEOF ROOT BALL.·EMITTERS SHALL BE SELF-FLUSHING, PRESSURE COMPENSATING-TYPE UNLESSNOTED OTHERWISE WITHIN TECHNICAL SPECIFICATIONS.·DRIP VALVE ZONES ARE DESIGNED TO ACCOUNT FOR DIFFERENCES IN PLANTREQUIREMENTS (HYDROZONES) AND SUN EXPOSURE.·CONTRACTOR SHALL ENSURE HYDROZONES ARE VALVED SEPARATELY AS SHOWNON PLAN.·SITE CONDITIONS MAY DICTATE THAT MULTIPLE SUN EXPOSURES ARE VALVEDTOGETHER DURING THE DESIGN PROCESS. CONTRACTOR SHALL ADJUST EMITTERSCHEDULE AS FOLLOWS:··EMITTER QUANTITIES SHALL REMAIN THE SAME BUT EMITTER GALLONAGES SHALLBE DOUBLED FOR PLANTS WITH SOUTH AND WEST EXPOSURES.··EMITTER QUANTITIES AND GALLONAGE SHALL BE AS SHOWN IN SCHEDULE FORPLANTS WITH NORTH AND EAST EXPOSURES.··PLANTINGS WITH NORTH AND EAST EXPOSURE SHALL DICTATE VALVE RUN-TIMESAND CONTRACTOR SHALL ADJUST SCHEDULING ACCORDINGLY.DOWN4:1(+)-SLOPESECTION10" MIN4"-6"PLANTING BACKFILL MATERIALPOLY DRIP TUBINGPLANT ROOTBALLEMITTER - STAKE TO EDGE OFROOTBALLEMITTER MICRO-TUBING - 60"MAXIMUM LENGTHPLANT MATERIALEMITTER - REFER TO SCHEDULE FOREMITTER QUANTITY. REFER TOSPECIFICATIONS FOR MANUFACTURERAND MODEL NUMBER.MULCH LAYEREMITTER MICRO-TUBINGPOLY DRIP TUBING - RE:TECHNICAL SPECIFICATIONS6" 10 GAUGE JUTE STAKE ORAPPROVED EQUALPLAN18DRIP EMITTERBELOW GRADEFINISH GRADEDEFLECT TUBING TO PERMITENTRY THROUGH BOTTOM OFVALVE BOX.12" POP-UP SPRAY HEAD WITHCHECK VALVE, GPH GDFNINDICATOR NOZZLE, & SWING PIPE(ZONE OPERATIONAL INDICATOR)PLANT MATERIAL34" PVC BALL VALVE WITH 34" PVCINSxMIPT ADAPTER AND S.S. CLAMP34" DRIP TUBING - COIL SUFFICIENTLENGTH IN BOX TO EXTEND HOSEADAPTER OUTSIDE OF VALVE BOX.34" WASHED RIVER ROCK SUMP (1CU. FT.)INSERT TEE WITH CLAMPS10" ROUND VALVE BOX WITH COVER- BRAND "DB" INTO VALVE BOX LID.REFER TO TECHNICALSPECIFICATIONS.SECTIONPLANDISTANCES VARY: CONTRACTOR SHALLLOCATE FLUSH VALVE BOX TO BESCREENED BY PLANT MATERIAL ANDACCESSIBLE. OPERATIONAL INDICATORSHALL BE LOCATED FOR EASYVISIBILITY DURING OPERATIONPLANT MATERIALINDICATOR HEADPLANTER BEDWALL OR EDGERFLUSH VALVEPOLY PIPE FROMEXHAUST HEADEROR DRIP LATERALDRIP FLUSH VALVE19WITH OPERATIONAL INDICATORPVC MAINLINEPVC SCH. 40 TEE OR ELL2" PVC SCH. 80 NIPPLE ANDPVC SCH. 40 ELL3" MIN. DEPTH 34" WASHED GRAVELVALVE SIZE MIPTxINS. PVC ADAPTERJUMBO VALVE BOX - BRAND BOXLID W/ CONTROLLER ANDSTATION NUMBER - REFER TOTECHNICAL SPECIFICATIONS.PVC SCH. 80NIPPLEPVC SCH.40 ELLFINISH GRADELINE SIZE PVC BALL VALVE3" MIN.DRIP VALVE ASSEMBLY(SEE SCHEDULE)STAINLESS STEEL WORM GEAR ORPINCH CLAMPVALVE SIZE POLY PIPING -SWEEP TO SPECIFIED DEPTHTWO BLACK WIRES TO VALVE SOLENOIDDECODERDBR-6 (2)PROVIDE 60" CONTINUOUS COILS OFALL "MAINTENANCE" SPARECONTROL/COMMON WIRING WITHINVALVE BOX (PER DECODER)TWO-WIRE PATH TO NEXT DECODERTO EARTH GROUND INSTALLED INSEPERATE LOCATION PER ASICGUIDELINES. 1 PER 12 DECODERSOR EVERY 1000 ftTWO-WIRE PATH TO NEXT DECODERDBR-6 (2)DBR-6NOTE:INSTALL ASSEMBLY TO REST ON GRAVEL SUMP. CONTAIN ENTIREASSEMBLY WITHIN BOX. NO VALVE BOX EXTENSIONS WILL BEACCEPTED. PROVIDE 3"-4" CLEARANCE BETWEEN TOP OF CONTROLVALVE SOLENOID AND BOTTOM OF VALVE BOX LID. TOP OF VALVEBOX TO BE FLUSH WITH FINISH GRADE. VALVE BOX SHALL NOT RESTON DRIP TUBING.DRIP VALVE17TWO-WIRE SYSTEM - KIT - POLY PIPEFINISH GRADESUBGRADERECTANGULAR VALVEBOX WITH CONTROLVALVE AND DECODERSECURE DECODER TO 6"x1" PVC PIPEWITH PIPE CAP VIA. NYLON WIRE TIE(2)REBAR STAKE1" MINIMUM12" MINIMUMWIRE PATH FROM CONTROLLER ALLOW 5FT. SLACK PER DECODER. ALL WIRE TO BETO 14 UAG STANDARDS. REFER TO TWOWIRE PLAN FOR CONTROLLER WIREMANUFACTURE AND MODEL NUMBER.DECODER, WIRE END DOWN (REFERTO SCHEDULE FOR MODEL NUMBER)ID WIRE PATH TO NEXTDECODER (3M) DBY (2)DECODER INSTALLATION20TWO-WIRE SYSTEMFINISH GRADEUSE WIRE CLAMP TO HOLDGROUNDING WIRE TO RODDURING CADWELD.34" CRUSHEDGRAVELSUMP (2 CU.FT.)8 FT COPPER GROUNDING RODOR PLATE (SEE NOTES & SPECS).3"#6 SOLID COPPER WIRE FROMARRESTOR TO GROUNDING RODOR PLATE (SEE NOTES & SCHEDULE).LIGHTNINGARRESTORWATER PROOFCONNECTORPER SPECS.TWO-WIRECABLE TONEXT DEVICE(DECODER, ORARRESTOR)MAINLINE & WIRE PATHGROUNDING RODPLAN VIEW, TYPICALCROSS SECTION VIEW8'-12' MIN.NOTE:·ALL GROUNDING PER ASIC GUIDELINES.·GROUNDING ROD MUST BE INSTALLED INSIDEAN IRRIGATED AREA.·GROUNDING TO 10 OHMS MAXIMUM.·GENERAL LAYOUT OF ROD AS SHOWN.·NO ELECTRONIC EQUIPMENT SHALL BE PLACEDWITHIN THE GROUNDING ROD BUFFER AREA.·IF MINIMUM BUFFER AREA CANNOT BEACHIEVED DUE TO NARROW LANDSCAPE AREAOR OTHER PHYSICAL RESTRICTIONS,CONTRACTOR TO USE GROUNDING PLATE PERMANUFACTURER'S RECOMMENDATIONS.10" ROUNDVALVE BOXTWO-WIRE SYSTEM - TYPICALARRESTOR GROUNDING21GROUNDING MUST MEET ALL MANUFACTURER'S REQUIREMENTS. IN ADDITION,GROUNDING PLATE DESIGN CONSISTS OF ONE VERTICAL 8-FOOT COPPER CLADGROUNDING ROD (AT LEAST EIGHT FEET FROM THE EQUIPMENT), AND ONE COPPERGROUNDING PLATE PER 40 STATIONS REQUIRING GROUNDING. INSTALL GROUNDINGPLATE HORIZONTALLY, THREE FEET DEEP AND 15' FROM THE GROUNDING ROD.SHOULD MULTIPLE RODS/PLATES BE REQUIRED, THEY SHALL BE PLACED A MINIMUMOF 3 LINEAR FEET FROM EACH OTHER. PERFORM CADWELD CONNECTION TOGROUNDING ROD(S) AND PLACEMENT OF GROUNDING PLATE(S) IN OWNER'SPRESENCE PRIOR TO BACKFILL. REFER TO ASIC STANDARDS FOR MOREINFORMATION.FINISH GRADESATELLITE CONTROLLER(S)#6 CONTINUOUS SOLID BARE COPPER WIRE (TYPICAL)CADWELD GT1161G "ONE SHOT" WELD58" x 8FT COPPER-CLAD GROUNDING ROD#6 CONTINUOUS SOLID BARE COPPER WIRE (TYPICAL)COPPER GROUNDING PLATE 4"x96"x0.0626"GROUND ENHANCEMENT MATERIAL PERMANUFACTURER'S RECOMMENDATIONS1'8'15'3'22CONTROLLER GROUNDINGTWO-WIRE SYSTEM - Pedestal MountFINISH GRADERECTANGULAR VALVE BOX WITHEXTENSION - BRAND "MV" INTOVALVE BOX LID. REFER TOTECHNICAL SPECIFICATIONS.FIPTxFIPT SCH. 80 PVC UNIONS (2)PRESSURE MAINLINE34" CRUSHED GRAVEL SUMP - 2 C.F.Y-STARINER23Y-STRAINERRKnow what's below.Call before you dig.orwww.UNCC2.orgDIRECTORYIRRIGATION SCHEDULE IR1.0IRRIGATION NOTES IR1.0IRRIGATION PLANS IR1.1 - IR1.6IRRIGATION DETAILS IR2.1 - IR2.313949 W. Colfax Ave,, Suite 260 Lakewood, Colorado 80401o: 303.980.5327 www.hydrosystemskdi.comIrrigation Consulting & Water ManagementNTSIR2.2 - IRRIGATION DETAILS