Loading...
HomeMy WebLinkAbout082 C405_OffsiteUtilityPlanMW TV WV WV WV DYH S 8S8S8S8SDYH 8W8W8W8W8WWSWSWS 8W 8W 8W 8W 8W 8W 8W 8W 8W8W8W8W8W8W8W8W8W8W8WE E E BPBPBPBPBP BP BP BP BP BP BP BP BP BP UTIL UTILUTILUTIL UTIL UTILBPBPBPBPPROPOSED BUILDING O PROPOSED BUILDING N PROPOSED SANITARY SEWER MANHOLE, (TYP) PROPOSED FIRE HYDRANT, (TYP) PROPOSED ELECTRIC UTILITY METER, (TYP) 10' PUBLIC UTILITY EASEMENT 10' PUBLIC UTILITY EASEMENT 30' PUBLIC ACCESS & UTILITY EASEMENT CONNECT TO EXISTING 8" WATER MAIN SAW CUT EXISTING ASPHALT ROADWAY (APPROX.27 LF & 75 SF) VERIFY SCALE! THESE PRINTS MAY BE REDUCED. LINE BELOW MEASURES ONE INCH ON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY! 2021COPYRIGHT © MORRISON-MAIERLE, INC., SHEET NUMBER PROJECT NUMBER DRAWING NUMBER DATEDESCRIPTIONNO.BY N:\6475\005 - BUFFALO RUN - SITE PLAN\ACAD\SHEETS\6475.005 - C400 UTILITY PLAN SHEETS.DWG PLOTTED BY:LEE HAGEMAN ON Nov/12/2021 REVISIONS DRAWN BY: DSGN. BY: APPR. BY: DATE: Q.C. REVIEW DATE: BY: 2880 Technology Blvd West Bozeman, MT 59718 406.587.0721 www.m-m.net engineers surveyors planners scientists MorrisonMaierle THE HOMESTEAD AT BUFFALO RUN BOZEMAN MONTANA OFFSITE UTILITY PLAN (5 OF 5) 6475.005 20 C405 DAH LRH MEE 10/2021 30 6015300 SCALE IN FEET SITE PLAN SUBMITTAL 10/2021 MATCH LINE C404 Know what's below. before you dig.Call R 10/20/2021 1.ALL IMPROVEMENTS ON THIS PROJECT SHALL BE COMPLETED IN ACCORDANCE WITH THE MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS, 6TH EDITION DATED APRIL 2010 (MPWSS); THE CITY OF BOZEMAN MODIFICATIONS TO THE MPWSS; AND THE PROJECT SPECIFICATIONS. 2.THE CONTRACTOR SHALL RESTORE ALL ROADWAY SURFACES TO EQUAL OR BETTER CONDITION THAN EXISTED PRIOR TO EXCAVATION AS DETERMINED BY AGENCY, OWNER, AND/OR ENGINEER. 3.ASPHALT, CONCRETE CURB, AND SIDEWALK SHALL BE SAW CUT OR NEAT CUT AS APPROVED BY AGENCY AND/OR ENGINEER. 4.ALL TEXT AND FEATURES SHOWN SHADED ARE EXISTING. SEE SHEET C017 FOR MORE COMPLETE DEPICTION OF EXISTING CONDITIONS. 5.THE LOCATION, DEPTH, AND SIZE OF THE EXISTING UTILITIES SHOWN ON THESE PLANS IS APPROXIMATE. THE CONTRACTOR SHALL VERIFY THE EXISTENCE, LOCATION, DEPTH AND SIZE OF THE UTILITIES PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY DAMAGE TO THE EXISTING FACILITIES DUE TO FAILURE TO LOCATE OR PROPERLY PROVIDE PROTECTION WHEN LOCATION IS KNOWN. 6.ALL WATER VALVES OWNED AND OPERATED BY THE CITY OF BOZEMAN SHALL BE OPERATED BY AUTHORIZED CITY OF BOZEMAN PERSONNEL ONLY. 7.SEWER AND WATER CONNECTIONS SHALL BE PERFORMED BY A LICENSED PLUMBER. 8.GENERAL CONTRACTOR TO COORDINATE DRY UTILITY AND IRRIGATION REQUIREMENTS. 9.DOMESTIC SERVICE SIZES PROPOSED (VERIFY WITH ARCHITECTURAL/MECHANICAL) DUPLEX = 1.25"; COMMUNITY CENTER = 1.25"; BUILDINGS A-F & H = 4"; BUILDINGS G, J, K, L &N = 2"; BUILDINGS I, M, & O = 1.25" GENERAL NOTES: