Loading...
HomeMy WebLinkAbout017 - L2.1 IRRIGATION PLANDURSTAN ROAD NAHORNIAKBOZEMAN, MTDURSTAN ROADXIRRIGATION NOTES 2. Mainline piping shall be 1” SCH40 PVC. All lateral piping shall be SCH40 PVC and/or 100psi PE pipe. All pipe sizes are 1” on plan. Drip piping is acceptable at 3/4”. 3. Wiring is 18awg multi-strand. 1. The plan is diagrammatic for piping, wiring, and head locations. Adjust all piping and heads when obvious obstructions or grade changes exist. 4. Sprinkler head spacing and location dictate type of MP100 and MP2000 Rotator nozzle. 6. All electrical and manual valves are to be installed within 12” depth standard size or larger boxes. No more than four valves allowed per box. 5. A Rainbird ESP3ME controller shall be installed in the designated location (TBD). Power source for irrigation controller to be supplie by others and coordinated with general contractor. 7. An appropriate backflow assembly and exterior connection point shall be supplied and installed by others within approved mechanical room (TBD). It is the responsibility of the landscape contractor to coordinate installation per local codes and ordinaces as well as with architecture and all other trades. 8. Install a Rainbird WR2RFC Rain/Freeze sensor in a location where obvious overhead obstructions are absent and sensor will not be oversprayed by irrigation system 9. Turf valves to be line-size Rainbird DV100 and Drip valves to be Rainbird XCZLF-100-PRF. All isolation valves shall be line-sized ( 1” ). 10. Irrigation Contractor shall adjust all sprinklers to provide proper radius and to minimize overspray onto buildings, sidewalks, roads, etc. 11. All Sprinkler nozzles to be Hunter MP Rotators with Rainbird 1804SAM-P45 spray bodies or equal. 12. Planting beds shall be irrigated with point-source drip irrigation based on individual plant water-requirements. 13. All mixed shrub and tree plantings to be irrigated with dedicated drip tubing. Drip emitters to be adjusted per requirements of each individual plant. See Plant Water Schedule. 14. System designed to fall within opertating pressure of 60 psi. and 15 gpm. 15. ALL SLEEVING TO BE 4” SCH40 PVC. No Exceptions. Sleeving to be supplied and installed by others. It is the responsibility of the landscape contractor to coordinate installation with General Contractor. 16. All information to be field verified by Landscape Contractor prior to installation. 17. The contractor shall maintain an accurate and current ‘as-built’ on site at all times. Days Zone GPM Duration Minutes Initial GPD (2X Runtime) Estimated GPD Total Daily Initial Total Daily Established 1,3,5,7 2,4,6 1 2 3 4 5 6 7D 8D 6 4 4 14 11 11 3 2 30 30 30 30 30 30 15 45 180 120 120 420 330 330 45 90 360 240 240 840 660 660 90 180 3,270 gal.1,635 gal. - - - - - - - - 3,270 gal.0 gal. Proposed Irrigation Schedule System A 1 2 3 4 5 6 7D 8D 6 4 4 14 11 11 3 2 30 30 30 30 30 30 15 45 360 240 240 840 660 660 90 180 Days Zone GPM Duration Minutes Initial GPD (2X Runtime) Estimated GPD Total Daily Initial Total Daily Established 1,3,5,7 2,4,6 1 2 3 4 5D 6 14 13 11 2 30 30 30 30 15 180 420 390 330 30 360 840 780 660 60 2,700 gal.1,350 gal. - - - - - 2,700 gal.0 gal. Proposed Irrigation Schedule System B 1 2 3 4 5D 6 14 13 11 2 30 30 30 30 15 360 840 780 660 60 1” - 1.5” Caliper Tree irrigate w/ .25gpm bubbler 2” - 2.5” Caliper Tree irrigate w/ .25gpm bubbler 4’ Spruce irrigate with .25 gpm bubbler 6’ - 8’ Spruce irrigate with (2) .25 gpm bubbler 10’ - 12’ Spruce irrigate with (3) .25 gpm bubbler Trees in Turfgrass 1gal pot irrigate with (1) .5gph emitters 2gal pot irrigate with (1) 1gph emitters 5gal pot irrigate with (2) 1gph emitters 10gal pot irrigate with (2) 2gph emitters 1” - 1.5” Caliper Tree irrigate w/ (3) 2gph emitters 2” - 2.5” Caliper Tree irrigate w/ (4) 2gph emitters 4’ Spruce irrigate with (3) 2gph emitters 6’ - 8’ Spruce irrigate with (4) 2gph emitters 10’ - 12’ Spruce irrigate with (5) 2gph emitters Trees/Shrubs in Beds MP2000 - 180 = .77gpm @40psi. MP2000 - 360 = 1.48gpm @40psi. MP1000 - 90 = .21gpm @40psi. MP1000 - 180 = .42gpm @40psi. MP1000 - 360 = .84gpm @40psi. MP2000 - 90 = .43gpm @40psi. MPSS = .44gpm @40psi. MP3000 - 90 = .86gpm @40psi. MP3000 - 180 = 1.82gpm @40psi. MP3000 - 360 = 3.64gpm @40psi. MPCS = .22gpm @40psi. MP Rotator Performance Data Plant Water Schedule (2) 4” Sleeves C C 6A 1 4A 3 2A 8D 4A 214A 411A 5 11A 6 11B 4 13B 3 6B 1 14B 2 3A 7D 2B 5D OFF ON 3" MIN. BRICK (1 OF 4) (LENGTH AS REQUIRED) PVC MAINLINE PIPE RAIN BIRD VB-STDFINISH GRADE/TOP OF MULCH VALVE BOX WITH COVER: REMOTE CONTROL VALVE: PVC SCH 40 ELL 30-INCH LINEAR LENGTH OF WIRE, COILED ID TAG: RAIN BIRD VID SERIES WATERPROOF CONNECTION: RAIN BIRD SPLICE-1 (1 OF 2) HIDDEN) AND SCH 40 ELL PVC SCH 80 NIPPLE SCH 80 NIPPLE (2-INCH LENGTH, PVC SCH 40 TEE OR ELL 3.0-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL POLYETHYLENE LATERAL PIPE RAIN BIRD 100-DV-MB POLYETHYLENE PIPE CLAMP ELECTRIC REMOTE-CONTROL VALVE2N.T.S.DV SERIES 100-DV-MB QUICK-COUPLING VALVE: (LENGTH AS REQUIRED)PVC SCH 80 NIPPLE PVC MAINLINE PIPE (LENGTH AS REQUIRED)PVC SCH 80 NIPPLE 3-INCH MINIMUM DEPTH OF VALVE BOX WITH COVER: CLAMPS OR EQUIVALENT SUPPORT SYSTEM RAIN BIRD MODEL 3RC RAIN BIRD VB-6RND STAINLESS STEEL GEAR PVC SCH 40 TEE OR ELL PVC SCH 40 ELL 2" x 2" REDWOOD STAKE WITH FINISH GRADE/TOP OF MULCH 3/4-INCH WASHED GRAVEL PVC SCH 40 STREET ELL BRICK (1 OF 2) PVC SCH 40 STREET ELL NOMINAL QUICK COUPLING VALVE INLET SIZE.FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TONOTE: 4 QUICK COUPLING VALVE MODEL 3RCN.T.S. 12"18"12"18" FINISH GRADE LATERAL LATERAL MAIN LINE BEDDING LOW VOLTAGE WIRE LOW VOLTAGE WIRE SECTIONS SNAKE ALLLATERAL PIPEIN TRENCH PIPE, WIRE, TRENCHING5N.T.S. SWING PIPE, 12-INCH LENGTH: PVC/POLY LATERAL PIPE RAIN BIRD MODEL SP-100 BARB ELBOW: RAIN BIRD1/2-INCH MALE NPT x .490 INCH MODEL SBE-050 PVC SCH 40 TEE OR ELL MODEL SBE-050 1/2-INCH MALE NPT x .490 INCH BARB ELBOW: RAIN BIRD FINISH GRADE/TOP OF MULCH RAIN BIRD 1804POP-UP SPRAY SPRINKLER:-SAM-P45 3 POP-UP SPRAY SPRINKLER 1804 WITH SWING PIPEN.T.S. WITH RAIN BIRD ROTARY NOZZLE MP ROTATOR NOZZLE GALVANIZED TIEDOWN STAKE: PRESSURECOMPENSATING EMITTER MODULE " VINYL DISTRIBUTION TUBING DIFFUSER BUG CAP TREE XERI-TUBE ADAPTERFITTING AND RISER LATERAL PIPE FLUSH FITTINGTREE PLAN DIFFUSER BUG CAP: " TUBING STAKE: MULCH AS SPECIFIED WEED CONTROL FABRIC " VINYL DISTRIBUTION TUBING XERI-TUBE SINGLE-OUTLET EMITTER TREE SECTION NOTE: 1.EMITTERS SHOULD BE PLACED INSIDE TREE WELL, HALFWAYBETWEEN THE BASE OF THE TREE AND EDGE OF ITS CANOPY. 2.RUN XERI-TUBE DISTRIBUTION TUBING NOMORE THAN 250' LENGTH 3.RUN 14" VINYL DISTRIBUTION TUBING NOMORE THAN 5' LENGTH TREE AND SHRUB DRIP6N.T.S. 14 14 14 MOUNTING WALL RAIN BIRD ESP-ME3 -INCH PVC SCH 40 CONDUIT WIRES TO VALVES STANDARD MODULE FOR4-STATION CONTOLLERS OPTIONAL MODULES FOR22-STATION CONTROLLERSTANDARD 120 V PLUG ESP-ME3 MODULAR HYBRID CONTROLLER INSIDE FRONT COVER INSIDE CONTROLLER CHASSIS WIRES TO VALVES 120 VAC, 60 HZ INTERNALTRANSFORMER 1 N.T.S. 34 4” SCH40 Sleeving MP STRIP Zone Valve MP 1000/MP2000 Isolation Valve Quick Connect ZONE # GPMCONTROLLER## # 1” Mainline w/ multi-strand 3/4” or 1” Drip supply line IRRIGATION LEGEND 1” Lateral line MP3000 ControllerC