Loading...
HomeMy WebLinkAbout03--A004 - CODE AND LIFE SAFETYCITY OF BOZEMAN, MT BUILDING CODES:2018 INTERNATIONAL BUILDING CODE (IBC)2018INTERNATIONAL EXISTING BUILDING CODE2018 INTERNATIONAL MECHANICAL CODE (IMC)2018UNIFORM PLUMBING CODE (UPC) 2017NATIONAL ELECTRIC CODE (NEC)2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)2018INTERNATIONAL FUEL GAS CODE (IFGC)2005 ICC A117.1. ACCESSIBLE AND USABLE BUILDINGS AND FACILITIESBUILDING CODE SUMMARYCHAPTER 3 -OCCUPANCY:303.1 ASSEMBLY GROUP A:GROUP A-3 OCCUPANCY INCLUDES ASSEMBLY USES INTENDED FOR WORSHIP, RECREATION OR AMUSEMENT AND OTHER ASSEMBLYUSES NOT CLASSIFIED ELSEWHERE IN GROUP A INCLUDING, BUT NOT LIMITED TO:GYMNASIUMS WITHOUT SPECTATOR SEATNGAPPLICATION:BOZEMAN PILATESLOBBY304.1 BUSINESS GROUP B.BUSINESS GROUP B OCCUPANCY INCLUDES, AMONG OTHERS, THE USE OF A BUILDING OR STRUCTURE, OR A PORTION THEREOF, FOR OFFICE, PROFESSIONAL OR SERVICE-TYPE TRANSACTIONS, INCLUDING STORAGE OF RECORDS AND ACCOUNTS. BUSINESS OCCUPANCIES SHALL INCLUDE, BUT NOT BE LIMITED TO, THE FOLLOWING:COFFEE SHOP WITH OCCUPANT LOAD LESS THAN 50APPLICATION:TENANT SPACE 2309.1 MERCANTILE GROUP MMERCANTILE GROUP M OCCUPANCY INCLUDES, AMONG OTHERS, THE USE OF A BUILDING OR STRUCTURE OR A PORTION THEREOF FOR THE DISPLAY AND SALE OF MERCHANDISE, AND INVOLVES STOCKS OF GOODS, WARES OR MERCHANDISE INCIDENTAL TO SUCH PURPOSES AND ACCESSIBLE TO THE PUBLIC. MERCANTILE OCCUPANCIES SHALL INCLUDE, BUT NOT BE LIMITED TO, THE FOLLOWING:RETAILAPPLICATION:TENANT SPACE 2OCCUPANCY TYPESRESIDENTIAL: GROUP R-2COMMERCIAL:GROUP A-3 (PRIMARY OCCUPANCY)GROUP B CHAPTER 10 -MEANS OF EGRESSSECTION 1005 MEANS OF EGRESS SIZING1005.3.2 OTHER EGRESS COMPONENTS. THE CAPACITY, IN INCHES, OF MEANS OF EGRESS COMPONENTS OTHER THAN STAIRWAYS SHALL BE CALCULATED BY MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH COMPONENT BY A MEANS OF EGRESS CAPACITY FACTOR OF 0.2 INCH (5.1 MM) PER OCCUPANT.APPLICATION: GROUND FLOOR EXITSSECTION 1016.2 EXIT ACCESS TRAVEL DISTANCEEXIT ACCESS TRAVEL DISTANCE SHOULD NOT EXCEED 250 FEET TO THE CLOSEST EXIT PER TABLE 1016.2CHAPTER 5 -GENERAL BUILDING HEIGHTS AND AREA: (CONTINUED)TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE:A/B/M OCCUPANCY:TYPE VA:50'-0" MAX HEIGHT.R OCCUPANCY:TYPE VA:50'-0" MAX HEIGHT.TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANEA-3 OCCUPANCY:2 STORIESB OCCUPANCY:3 STORIESR-2 OCCUPANCY:3 STORIESTABLE 506.2 ALLOWABLE AREA FACTORA-3 OCCUPANCY (NS)TYPE 5A:11,500 SFB OCCUPANCY (NS)TYPE 5A:18,000SFR-2 OCCUPANCY (NS)TYPE 5A:12,000SF*NO FRONTAGE INCREASE NEEDED**CHAPTER 5 -GENERAL BUILDING HEIGHTS AND AREA:TABLE 508.4 REQUIRED SEPERATION OF OCCUPANCIESADJACENT GROUPSFIRE RESISTANCE RATING (HOURS)A, B2A, RA, MM, R222A, B2CHAPTER 6 -TYPES OF CONSTRUCTION:FIRE RESISTANCE RATING FOR BLDG. ELEMENTS: (IBC TABLE: 601)TYPE VABUILDING ELEMENTBEARING WALLS -EXTERIORBEARING WALLS -INTERIOR ROOM SEPARATIONNONBEARING WALLS AND PARTITIONSFLOOR CONSTRUCTIONROOF CONSTRUCTION1 HOUR1 HOUR0 HOURS1 HOURS *1 HOURSPRIMARY STRUCTURAL FRAME1 HOURTABLE 602FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCETYPE VAGROUP A, B, R1 HOURGROUP M1 HOURFIRE SEPARATION DISTANCE: 10'-0"-15'-0"SECTION 906 -PORTABLE FIRE EXTINGUISHERSPORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED WITH A MAXIMUM TRAVEL DISTANCE OF 75'-0" TO AN EXTINGUISHER WITH ONE 2-A RATED EXTINGUISHER FOR EVERY 3,000 SQUARE FEET OF FLOOR AREA.CHAPTER 9 -FIRE PROTECTION AND LIFE SAFETY SYSTEMS2902.1 MINIMUM NUMBER OF FIXTURESPLUMBING FIXTURES SHOULD BE PROVIDED IN THE MINIMUM NUMBER AS SHOWN IN TABLE 2902.1 BASED ON THE ACTUAL USE OF THE BUILDING OR SPACE.CHAPTER 29 -PLUMBING SYSTEMSMONTANA STATE RULE 24.301.351 MINIMUM REQUIRED PLUMBING FIXTURESMONTANA STATE CODE 24.301.351Occupancy or UseWater Closets(Urinals - see footnotes g&mMale FemaleLavatories Bathtubs/ShowersDrinking FountainsBUSINESS1 per 25 1 per 251 per 2 water closetsNAMERCANTILE1 per 500 1 per 5001 per 750 NARESTAURANTS1 per 75 1 per 751 per 2 water closetsNAONE AND TWO FAMILY DWELLING1 PER DWELLING UNIT1 PER DWELLING UNIT1 PER DWELLING UNITMONTANA STATE CODE 24.301.351 REQUIREDOccupancy or UseWater Closets(Urinals - see footnotes g&mMale FemaleLavatories Bathtubs/ShowersDrinking FountainsBUSINESS1131ONE AND TWO FAMILY DWELLING2221MONTANA STATE CODE 24.301.351 PROVIDEDOccupancy or UseWater Closets(Urinals - see footnotes g&mUNISEXLavatories Bathtubs/ShowersDrinking FountainsBUSINESS 3 1ONE AND TWO FAMILY DWELLING522129 OCCUPANTS42 OCCUPANTS11229 OCCUPANTS42 OCCUPANTS22345678910FEDCBAGH1PROJECT NO:DATE:2100404/12/2022All reports, drawings, specifications, computer files, field data, notes, other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect, LocalElementArchitects, LLC. The Architect shall retain all common law, statutory and other reserved rights, including copyright thereto. The use of this drawing shall be restricted to the original site for which it was prepared and publication thereof is expressly limited to such use. Reuse, reproduction or publication by any method is prohibited without written consent from LocalElementArchitects, LLC. SITE PLAN REVIEW4/13/2022 10:07:03 AM C:\Users\chris\OneDrive\Documents\3753 Equestrian Lane--Central--LE_chrisTMMND.rvtBOZEMAN PILATES3753 EQUESTRIAN LANEBOZEMAN, MT. 59718A004CODE AND LIFESAFETYREVISIONSNO. DATE DESCRIPTION