Loading...
HomeMy WebLinkAbout02--A001 - PROJECT INFORMATIONPARCEL AND SITE COVERAGE INFORMATIONLOT COVERAGESITEAREA %FLOOR AREAPROJECTAREA %F.A.R.SITE 13,391.4 SF / .3074 ACRES ----OVERALL BUILDING3,656 SF27%9,933SF100%.74 FARRESIDENTIAL UNITS----2,874 SFCOVERED PARKING----0 SFPUBLIC/CIRCULATION/LOBBY1,261 SFOPEN SPACESHARED COM. OPEN SPACE600SFNAPUBLIC PARK LAND DEDICATION TRACKING TABLE -B2 ZONINGSUBDIVISION NAMEEXEMPT FROM PARKLAND REQUIREMENTS PER FINAL PLATE COMPLETED 7/4/2004OPEN SPACE/PATIOS2,001 SFSITE/BUILDING AREASFORM/INTENSITY STANDARDSPROVIDEDMAX PER TABLE 38.320.050MAX LOT COVERAGEBUILDING HEIGHTFARSETBACKS3,656 SF -27%100%COMPLIES.74 FARNACOMPLIES35'-0"--COMPLIESSEE SITE PLANCOMPLIESSEE SITE PLANMIN. FLOOR TO CEILING HT.13'-0"COMPLIES13'-0"GROUND FLR COMMERCIAL5,789 SFSHARED RES. OPEN SPACE1,269 SF SHARED150 SF PER UNITPROVIDEDREQUIREDBAXTER MEADOWSSHAFT ENCLOSURES:NONEROOF/ ROOF CEILING:CLASS A ZONING DISTRICT:B2OCCUPANCY:A-3,ECONSTRUCTION TYPE:TYPE VABUILDING JURISDICTION:CITY OF BOZEMANADDRESS:3753 EQUESTRIAN LANE, BOZEMAN, MT 59718SITE AREA:13,391.4 SFPARKING REQ.:SEE PARKING CALCS ON SHEET A1.1USE:ASSEMBLY/RESIDENTIAL/LEGAL DESCRIPTION:BAXTER MEADOWS SUB PH 2A, S34, T01 S, R05 E, BLOCK 16, LOT 5, ACRES 0.307, PLAT J-3832345678910FEDCBAGH1PROJECT NO:DATE:2100405/12/2022All reports, drawings, specifications, computer files, field data, notes, other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect, LocalElementArchitects, LLC. The Architect shall retain all common law, statutory and other reserved rights, including copyright thereto. The use of this drawing shall be restricted to the original site for which it was prepared and publication thereof is expressly limited to such use. Reuse, reproduction or publication by any method is prohibited without written consent from LocalElementArchitects, LLC. SITE PLAN REVIEW5/12/2022 8:03:38 PM C:\Users\chris\OneDrive\Documents\3753 Equestrian Lane--Central--LE_chrisTMMND.rvtBOZEMAN PILATES3753 EQUESTRIAN LANEBOZEMAN, MT. 59718A001PROJECTINFORMATIONGENERALA0.0 COVER SHEETA001 PROJECT INFORMATIONA002 STANDARD ADA DETAILSA003 STANDARD ADA DETAILSA007 PERSPECTIVESCIVILC1.0 COVER SHEETC2.0 EXISTING SITEC2.1 OVERALL SITEC2.2 SITE GRADING & DRAINAGEC2.3 UTILITY PLANC3.0 CIVIL DETAILSC3.1 STORMTECH CHAMBER DETAILSARCHITECTURALA100 NOTED/DIMENSIONED SITE PLANA201 DIMENSIONED FOUNDATION PLANA202 DIMENSIONED FIRST FLOOR PLANA203 DIMENSIONED SECOND FLOOR PLANA204 NOTED FIRST FLOOR PLANA205 NOTED SECOND FLOOR PLANA401 ROOF PLANA502 BUILDING SECTIONSA503 BUILDING SECTIONSA601 BUILDING ELEVATIONSA602 BUILDING ELEVATIONSA903 SITE DETAILSELECTRICALE0.0 SITE ILLUMINANCE CALCULATION PLANE0.1 SITE CATALOG SHEETSE0.2 SITE LIGHTING CATALOG SHEETSLANDSCAPEL1.0 SITE OVERVEIWL2.0 PLANTING NOTES + LEGENDL2.1 PLANTING PLANL3.0 IRRIGATION PLANL4.0 SITE DETAILSOWNER:EMILY SMITH-WILSON315 STAFFORD AVE.BOZEMAN MT, 59718CONTACT: EMILY SMITH-WILSONARCHITECT:LOCAL ELEMENT ARCHITECTS23 APEX DR. STE #100BOZEMAN MT, 59718P: 406.600.0408CONTACT:CHRIS YELEYCIVIL:WGM GROUP 109 E. MAIN STREET SUITE BBOZEMAN, MT 59715CONTACT: GARY FOX PE, LUKE STEINP: 406-728-4611CONTRACTOR:TBDSTRUCTURAL ENGINEER:DCI ENGINEERING106 S. FOWLER AVER SUITE 202. BOZEMAN, MT 59718P: 406.556.8600CONTACT: SAM FOXLANDSCAPE ARCHITECT:BYLA ARCHITECTS323 LEWIS ST. N, KETCHUM, ID 83340P: 208-726-5907CONTACT: KENDRA PIEDALUECONDITIONEDCOMMERCIAL TENANTTENANT #1 MLE PILATES 2876 SFTENANT SPACE #2 1909 SFTENANT SPACE #4 379 SFTENANT SPACE #3 635 SFCOMMERCIAL TENANT: 4 5798 SFCOMMON AREACOMMON AREA/LOBBY 249 SFCOMMON AREA/LOBBY 1012 SFCOMMON AREA: 2 1261 SFRESIDENTIAL TENANTRESIDENTIAL UNIT 1 1393 SFRESIDENTIAL UNIT 2 1480 SFRESIDENTIAL TENANT: 2 2874 SF9933 SFCOVERED PATIOCOMMON AREACOVERED EXIT 190 SFCOVERED ENTRY 542 SFCOMMON AREA: 2 732 SF732 SFPATIOCOMMON AREAROOF DECK 1269 SFCOMMON AREA: 1 1269 SF1269 SFTOTAL SF 11934 SFNORTHVICINITY MAP3753 EQUESTRIAN LANEBOZEMAN, MT 59718PROJECT LOCATIONEQUESTRIAN LN.CABALLO AVE.VAQUERO PKWY.DAVIS LN.GALLATIN GREEN BLVD.MILKHOUSE AVE.GALLOWAY ST.NORTHD2AE4111AE2031234AE204LOBBY10590123.B2?#1111AE2012AE3033AE30331TO FACE OF FRAMING OR CENTERLINE OF STRUCTURELEVELFINISH FLOOR100'-0"12'-0"CONSTRUCTION LIMITSELEVATION/DATUM REFERENCECOLUMN OR GRID LINECONSTRUCTION LIMITSKEY FOR ENLARGED PLANREVISIONMATCH LINEEXTERIOR ELEVATIONPARTITION TYPEINTERIOR ELEVATIONWINDOW IDENTIFICATIONDOOR IDENTIFICATIONKEYNOTE REFERENCEROOM NAME AND NUMBERDIMENSION LINENORTH ARROWBUILDING SECTIONWALL SECTIONDETAILNEWSIDE MATCHED TOSHEET NUMBER-SHEET NUMBERSECTION DESIGNATIONSECTION DESIGNATIONELEVATION DESIGNATIONSHEET NUMBERSHEET NUMBERDETAIL NUMBERSHEET NUMBERSHEET NUMBERROOM NUMBERDOOR #ROOM NAMETRUE NORTHMATCH LINEAE303105ELEVATION CHANGE REFERENCEMATERIAL CHANGE REFERENCE1'-0"CPTCT3ELEVATION DESIGNATIONCARD READER / KEY PAD / PUSH PLATEWINDOW ELEVATION TYPEKEYNOTESCITY OF BOZEMAN BUILDING CODE:2018 INTERNATIONAL BUILDING CODE (IBC)2018 INTERNATIONAL RESIDENTIAL (IRC) BUILDING CODE (ONE AND TWO FAMILY DWELLINGS) 2018INTERNATIONAL EXISTING BUILDING CODE2018 INTERNATIONAL MECHANICAL CODE (IMC)2018UNIFORM PLUMBING CODE (IPC) 2017NATIONAL ELECTRIC CODE (NED) 2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2018 INTERNATIONAL FUEL GAS CODE2009 ICC A117.1. ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES1. FIRE ALARM2. SIGNAGE3. HEALTH DEPARTMENTNEW MIXED USE BUILDING WITH 2-4 PRIMARY TENANT SPACES AND TWO RESIDENTIAL UNITS WITH ROOFTOP PATIOS1. COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES. 2. DISTRIBUTE CONSTRUCTION DOCUMENTS TO BIDDERS AND SUBCONTRACTORS IN COMPLETE SETS INCLUDING SPECIFICATIONS. INCLUDE DRAWINGS AS INDICATED BY THE SHEET INDEX. ENSURE THAT SUBCONTRACTORS BID ON ALL ITEMS ASSOCIATED WITH THEIR RESPECTIVE TRADE.3. VISIT THE JOB SITE AND INSPECT THE PREMISES TO CHECK EXISTING WORKING CONDITIONS. SHOULD CONDITIONS BE DISCOVERED WHICH WOULD IMPEDE THE WORK, REPORT IMMEDIATELY THOSE CONDITIONS TO THE ARCHITECT. COMMENCEMENT OF THE WORK IS A REPRESENTATION THAT THE EXISTING CONDITIONS ARE ACCEPTABLE. FAILURE TO NOTIFY ARCHITECT OF ANY ADVERSE CONDITIONS PRIOR TO COMMENCING CONSTRUCTION CONSTITUTES FULL SATISFACTION WITH THE EXISTING CONDITIONS AND THE INTENTION TO PERFORM THE WORK WITH NO INCREASE EITHER IN TIME OR MONEY FOR ANY IMPEDIMENTS TO THE WORK.4. CHECK ALL DIMENSIONS, INSPECT AND FIELD MEASURE PROJECT PRIOR TO FABRICATION OF ANY COMPONENT OR ORDERING ANY MATERIAL TO ENSURE PROPER FITTING OF THE WORK. REPORT ANY DISCREPANCIES BETWEEN THE DRAWINGS AND THE SITE TO THE ARCHITECT BEFORE PROCEEDING. COMMENCEMENT OF WORK OF ANY TRADE INDICATES ACCEPTANCE OF EXISTING CONDITIONS AND THE WORK OF PREVIOUS TRADES.5. VERIFY ALL DIMENSIONS AND CONDITIONS AT THE BUILDING SITE. IF A DIMENSIONAL DISCREPANCY IS NOTICED OR A CONDITION NOT COVERED IN THE DRAWINGS IS ENCOUNTERED, NOTIFY THE ARCHITECT BEFORE COMMENCING WITH THAT PORTION OF THE WORK.6. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO START OF CONSTRUCTION AND FOLLOW UP IN WRITING WITHIN TWO WORKING DAYS.DIMENSIONS TAKE PRECEDENCE OVER SCALE ON CONSTRUCTION DOCUMENTS. DO NOT SCALE DRAWINGS.7. PLANS AND SPECIFICATIONS ARE COMPLEMENTARY AND ARE INTENDED TO INCLUDE OR IMPLY ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF WORK. ANY ITEM OR WORK MENTIONED IN THE SPECIFICATIONS AND NOT SHOWN ON THE DRAWINGS, OR SHOWN ON THE DRAWINGS AND NOT MENTIONED IN THE SPECIFICATIONS, SHALL BE PROVIDED AS IF INCLUDED BY BOTH.8. BECOME FAMILIAR WITH OWNER'S OR FACILITY'S REQUIREMENTS PRIOR TO BIDDING AND COMPLY WITH THESE REQUIREMENTS. THIS INCLUDES, BUT IS NOT LIMITED TO BUILDING AND SITE SECURITY.9. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE APPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED AND CONDITIONED IN ACCORDANCE WITH THE MANUFACTURERS' WRITTEN SPECIFICATIONS OR INSTRUCTIONS UNLESS HEREINAFTER SPECIFIED TO THE CONTRARY.10. SUPERVISE AND DIRECT THE WORK USING SKILL AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION AND/OR INSTALLATION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK PROVIDED UNDER THE CONTRACT.11. EXECUTE ALL WORK IN A NEAT AND PROFESSIONAL MANNER, ACCEPTABLE TO OWNER.12. COORDINATE THE REMOVAL AND LEGAL DISPOSAL OF MATERIALS AND RUBBISH WITH THE BUILDING MANAGEMENT. COORDINATE ALL PARTS OF THE WORK SO THAT NO WORK SHALL BE LEFT IN AN UNFINISHED OR INCOMPLETE CONDITION.13. ITEMS NOT INDICATED IN THESE DOCUMENTS THAT CAN BE LEGITIMATELY AND REASONABLY INFERRED TO COMPLETE THE WORK AT HAND SHALL BE FURNISHED AS THOUGH IT WAS DETAILED HEREIN USING THE BEST MATERIALS AND WORKMANSHIP.14. INCLUDE IN BID THE HIGHEST QUALITY AND GREATEST QUANTITY FOR PURPOSE OF RESOLVING CONFLICTS IN THE CONSTRUCTION DOCUMENTS WHICH ARE IMPLIED OR UNDEFINED.15. NO SUBSTITUTIONS FOR ITEMS SPECIFIED WILL BE ACCEPTED WITHOUT PRIOR WRITTEN APPROVAL FROM THE ARCHITECT. SUPPLY THE ARCHITECT WITH ALL SAMPLES AND COMPARATIVE PRODUCT DATA REQUIRED TO EVALUATE PROPOSED SUBSTITUTIONS IN A TIMELY MANNER SO AS NOT TO PRECLUDE PROCUREMENT OF THE PRODUCT ORIGINALLY SPECIFIED OR ANY PROPOSED SUBSTITUTE.16. PROTECT EXISTING CONDITIONS AND NEW WORK FROM DAMAGE DURING CONSTRUCTION. REPAIR AT NO COST TO THE OWNER ANY DAMAGE TO ALL EXISTING CONDITIONS, COMPLETED WORK OR WORK BY OTHERS INCURRED WHILE FULFILLING THE OBLIGATIONS OF THIS CONTRACT.17. PATCH, REPAIR, REPLACE & FINISH ANY FLOOR, WALL, OR CEILING TO MATCH ADJACENT DUE TO ANY DEMOLITION.18. JUNCTURES OF NEW AND EXISTING OR OTHER WORK SHALL BE REPAIRED AND PATCHED TO MATCH ADJACENT EXISTING SURFACES. EXISTING WALLS REQUIRING MODIFICATIONS OF ANY KIND SHALL BE REFINISHED TO THE NEAREST OUTSIDE OR INSIDE CORNER.19. ALL EXISTING WALLS TO REMAIN ARE TO BE PATCHED AND MADE PAINT READY TO A LEVEL 4 FINISH FOR NEW WALL FINISHES.20. PATCH AND REPAIR ALL FIREPROOFING, IF PRESENT, THAT IS DAMAGED OR REMOVED BY CONSTRUCTION OR DEMOLITION.21. COORDINATE WITH ALL TRADES THE STORAGE OF BUILDING MATERIALS ON THE SITE TO AVOID OVERLOADING. COMPLY WITH LOCAL ORDINANCES AND OWNER OR FACILITY REQUIREMENTS FOR STORAGE OF MATERIALS.22. TAKE MEASURES TO ELIMINATE AIRBORNE PARTICLES IN ADJACENT SPACES NOT COVERED UNDER THE WORK OF THIS CONTRACT.23. PROVIDE A WRITTEN TWO YEAR WARRANTY FOR ALL WORK PROVIDED UNDER THE CONTRACT IN ADDITION TO INDIVIDUAL PRODUCT AND MANUFACTURER WARRANTIES. SUCH WARRANTY SHALL NOT LIMIT ANY OTHER WARRANTY, GUARANTY OR REMEDY REQUIRED BY LAW OR BY THE CONSTRUCTION DOCUMENTS. 24. PROVIDE AND PAY FOR ALL LABOR, MATERIALS, EQUIPMENT, TOOLS, CONSTRUCTION EQUIPMENT AND MACHINERY, TRANSPORTATION, PERMITS, FEES AND OTHER FACILITIES AND SERVICES NECESSARY FOR PROPER EXECUTION AND COMPLETION OF THE WORK.25. SUBMIT SHOP DRAWINGS AND PRODUCT DATA TO ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR PURCHASING.26. ALL MATERIALS AND EQUIPMENT FURNISHED UNDER THIS CONTRACT SHALL BE NEW UNLESS OTHERWISE SPECIFIED. ALL WORK SHALL BE GOOD QUALITY, FREE FROM FAULTS AND DEFECTS AND IN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS. ALL WORK NOT CONFORMING TO THESE STANDARDS MAY BE CONSIDERED DEFECTIVE. NO INFERIOR OR NON-CONFORMING WORK OR MATERIALS WILL BE ACCEPTED WHETHER DISCOVERED AT THE TIME THEY ARE INCORPORATED IN THE WORK OR AT ANY TIME BEFORE OR AFTER THE FINAL ACCEPTANCE. FURNISH SATISFACTORY EVIDENCE AS TO THE KIND AND QUALITY OF MATERIALS AND EQUIPMENT AT THE ARCHITECTS REQUEST.27. IF APPLICABLE, ALL OPENINGS IN FLOOR SLABS, INCLUDING THOSE FOR DUCTS, CONDUIT, PIPING, ETC. (EXCEPT THOSE COMPLETELY ENCLOSED BY FIRE-RESISTIVE SHAFT CONSTRUCTION) MUST BE SLEEVED OR OTHERWISE SEALED AT THEIR PERIMETER WITH APPROVED METHODS TO MAINTAIN THE FIRE-RATING CONTINUITY OF THE FLOOR CONSTRUCTION.28. ALL OPENINGS IN FIRE-RATED WALLS AND FLOOR / CEILING ASSEMBLIES INCLUDING DUCTS, CONDUIT, PIPING, ETC. MUST BE FILLED WITH APPROVED MATERIALS IN FIRE RATED ASSEMBLIES TO MAINTAIN THE FIRE-RATING CONTINUITY OF THE WALL CONSTRUCTION.29. WALL AND/OR CEILING ASSEMBLIES THAT ARE IDENTIFIED WITH A FIRE-RESISTANCE RATING SHALL BE CONSTRUCTED PER U.L. REQUIREMENTS, MANUFACTURER'S SPECIFICATIONS AND THE REQUIREMENTS OF ALL APPLICABLE CURRENT CODES.30. PATCH ALL EXISTING OPENINGS AND STUB-OUTS THAT WILL CONFLICT WITH NEW WORK.31. PROVIDE EMPTY CONDUIT AND JUNCTION BOXES FOR TELEPHONE / DATA SYSTEMS.PROVIDE PROPER SHORING AND DISCONNECTION OF ALL UTILITIES BEFORE COMMENCING DEMOLITION.32. COORDINATE, LOCATE AND CONFIRM THE LOCATION OF UNDERGROUND, BELOW FLOOR, AND OVERHEAD PLUMBING, MECHANICAL AND ELECTRICAL.33. PROVIDE "NO SMOKING" OR "SMOKE FREE" SIGNAGE AT ALL POINTS OF ENTRY TO THE BUILDING. SIGNS SHALL STATE THAT THIS IS A NO SMOKING ESTABLISHMENT OR HAVE THE INTERNATIONAL NO SMOKING SYMBOL WITH LETTERS OR SYMBOLS NOT LESS THAN 3" IN HEIGHT.34. ALL DOORS TO BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT.35. ALL INTERIOR OR EXTERIOR GLASS SUBJECT TO HUMAN IMPACT SHALL CONFORM TO STANDARDS SET FORTH BY THE IBC AND THE SAFETY STANDARD FOR ARCHITECTURAL GLAZING MATERIALS, TITLE 16 CFR PART 1201 AS ISSUED BY THE CONSUMER PRODUCT SAFETY COMMISSION, EFFECTIVE JULY 6, 1972, INCLUDING ALL AMENDMENTS TO DATE. IN CASE OF CONFLICT THE MORE STRINGENT REQUIREMENTS SHALL APPLY.36. PROVIDE BLOCKING AND ELECTRICAL CONNECTIONS FOR ALL MILLWORK, CASEWORK, ART, LIGHTING, PLUMBING AND OTHER WALL HUNG ITEMS. PROVIDE 2 X WOOD BLOCKING OR 6" X 16 GA. CONCEALED SHEET METAL BLOCKING FOR ALL WALL HUNG ITEMS UNLESS NOTED OTHERWISE. 37. ALL SIGNS REQUIRE SEPARATE PERMITS AND APPROVALS.38. NO EXTERIOR VENDING OR DISPLAY SHALL BE ALLOWED.39. THERE SHALL BE NO ROOF-MOUNTED OR GROUND-MOUNTED MECHANICAL, UTILITY, AND COMMUNICATION EQUIPMENT INSTALLED OR PERMITTED WITH THIS APPROVAL.40. ALL EQUIPMENT, UTILITIES, OR OTHER APPURTENANCES ATTACHED TO THE BUILDING SHALL BE AN INTEGRAL PART OF THE BUILDING DESIGN IN TERMS OF FORM, COLOR, AND TEXTURE.41. GENERAL CONTRACTOR IS RESPONSIBLE TO FOLLOW ALL APPLICABLE CODES AND STANDARDS AS ADOPTED BY THE LOCAL JURISDICTION. ANY OMISSIONS OR DISCREPANCIES WITHIN THE CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF THAT PORTION OF WORK.CFCI Contractor Furnished Contractor InstalledCFOI Contractor Furnished Owner InstalledC.L. Center Line CLR Clear CMU Concrete Masonry UnitCATV Cable TV CER. Ceramic CONC. ConcreteCONST. ConstructionCIM. DimensionDWG DrawingEQ EqualFE Fire ExtinguisherFF Finish Floor ElevationGA Gauge GC General ContractorGL Glazing HR Hour MAX MaximumMECH MechanicalMEP Mechanical Electrical & PlumbingMIN MinimumMO. Masonry OpeningN North NIC Not in ContractN.T.S. Not to scaleOC. On CenterOFCI Owner Furnished Contractor InstalledOFOI Owner Furnished Owner InstalledPLYWD PlywoodPREFAB PrefabricatedR.O. Rough OpeningR.O.W. Right of WaySF Square FeetSIM SimilarSTC Sound Transmission CoefficientSTD StandardSTRU StructuralTOJ Top of JoistTYP TypicalUNO Unless Noted OtherwiseVIF Verify in FieldPROJECT DIRECTORYPROJECT DATAADOPTED CODESDEFERRED SUBMITTALSPROJECT DESCRIPTIONABBREVIATIONSSYMBOLSARCHITECTURAL GENERAL GENERALAREA CALCULATIONSSHEET INDEXZONING: B2REVISIONSNO. DATE DESCRIPTION