Loading...
HomeMy WebLinkAboutSite A_PH1 Lighting Details 2022-02-07VERIFY SCALE! THESE PRINTS MAY BE REDUCED. LINE BELOW MEASURES ONE INCH ON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY! 2022COPYRIGHT © MORRISON-MAIERLE, INC., SHEET NUMBER PROJECT NUMBER DRAWING NUMBER DATEDESCRIPTIONNO.BY N:\3638\009\DESIGN DOCS\CALCS\ELECTRICAL\EVERHOME\PHOTOMETRIC SHEETS\FEBRUARY 2022\E-PHOTOMETRICS.DWG PLOTTED BY:CELINE SAUCIER ON Feb/07/2022 REVISIONS DRAWN BY: DSGN. BY: APPR. BY: DATE: Q.C. REVIEW DATE: BY: 2880 Technology Blvd West Bozeman, MT 59718 406.587.0721 www.m-m.net engineers surveyors planners scientists MorrisonMaierle BOZEMAN GATEWAY PUD EVERHOME HOTEL BOZEMAN MT LIGHTING DETAILS 3638.009 1 PH-1 AG AG JAU FEBRUARY 7, 2022 LUMINAIRE SCHEDULE SYMBOL TYPE LAMPS DESCRIPTIONS MANUFACTURER CATALOG NO. OR SERIES MOUNTING/ VOLTAGE E1 63W LED FULL-CUTOFF, DECORATIVE, EXTRUDED ALUMINUM FIXTURE WITH BLACK FINISH MOUNTED TO AN ALUMINUM, ROUND, 5 INCH NON-TAPERED, 25' POLE WITH A 24" CANTELEVERED ARMTO MATCH EXISTING LUMINAIRES IN THE BOZEMAN GATEWAY DEVELOPMENT. SECURE POLE TO A CONCRETE BASE AS DETAILED. SEE DETAIL 1 ON THIS SHEET. POLE SHALL BE RATED TO HANDLE FIXTURE AND ARM EPA AT 80 MPH WIND WITH 30% GUST. PROVIDE WITH TWO PIECE DECORATIVE, PHILADELPHIA STYLE BASE COVER. POLE, BASE COVER AND ARM FINISH SHALL MATCH FIXTURE. REFLECTOR SHALL BE A TYPE III DISTRIBUTION. FUSE EACH FIXTURE AT POLE BASE HAND HOLE. PROVIDE 3000K COLOR TEMPERATURE. ANTIQUE STREET LAMPS FIXTURE: EH16RT-63LED 350MA-3K-GCF-R3- 208-1DS-ANBK ARM: EAC5/2 PNIP3-ANBK POLE: DS340-R450V200-BK-HH-AB-P9/ WHATLEY D21M BLK POLE/ 208 E1HS 63W LED SAME AS TYPE E1 WITH HOUSE SIDE SHIELD ANTIQUE STREET LAMPS FIXTURE: EH16RT-63LED 350MA-3K-GCF-R3 HS- 208-1DS-ANBK ARM: EAC5/2 PNIP3-ANBK POLE: DS340-R450V200-BK-HH-AB-P9/ WHATLEY D21M BLK POLE/ 208 E2 (2) 63W LED FULL-CUTOFF, DECORATIVE, EXTRUDED ALUMINUM FIXTURE WITH BLACK FINISH MOUNTED TO AN ALUMINUM, ROUND, 5 INCH NON-TAPERED, 25' POLE WITH A 24" CANTELEVERED ARMTO MATCH EXISTING LUMINAIRES IN THE BOZEMAN GATEWAY DEVELOPMENT. SECURE POLE TO A CONCRETE BASE AS DETAILED. SEE DETAIL 1 ON THIS SHEET. POLE SHALL BE RATED TO HANDLE FIXTURE AND ARM EPA AT 80 MPH WIND WITH 30% GUST. PROVIDE WITH TWO PIECE DECORATIVE, PHILADELPHIA STYLE BASE COVER. POLE, BASE COVER AND ARM FINISH SHALL MATCH FIXTURE. REFLECTOR SHALL BE A TYPE III DISTRIBUTION. FUSE EACH FIXTURE AT POLE BASE HAND HOLE. PROVIDE 3000K COLOR TEMPERATURE. ANTIQUE STREET LAMPS FIXTURE: EH16RT-63LED 350MA-3K-GCF-R3- 208-1DS-ANBK ARM: EAC5/2 PNIP3-ANBK POLE: DS340-R450V200-BK-HH-AB-P9/ WHATLEY D21M BLK POLE/ 208 E3 63W LED FULL-CUTOFF, DECORATIVE, EXTRUDED ALUMINUM FIXTURE WITH BLACK FINISH MOUNTED TO AN ALUMINUM, ROUND, 5 INCH NON-TAPERED, 25' POLE WITH A 24" CANTELEVERED ARMTO MATCH EXISTING LUMINAIRES IN THE BOZEMAN GATEWAY DEVELOPMENT. SECURE POLE TO A CONCRETE BASE AS DETAILED. SEE DETAIL 1 ON THIS SHEET. POLE SHALL BE RATED TO HANDLE FIXTURE AND ARM EPA AT 80 MPH WIND WITH 30% GUST. PROVIDE WITH TWO PIECE DECORATIVE, PHILADELPHIA STYLE BASE COVER. POLE, BASE COVER AND ARM FINISH SHALL MATCH FIXTURE. REFLECTOR SHALL BE A TYPE IV DISTRIBUTION. FUSE EACH FIXTURE AT POLE BASE HAND HOLE. PROVIDE 3000K COLOR TEMPERATURE. ANTIQUE STREET LAMPS FIXTURE: EH16RT-63LED 350MA-3K-GCF-R4- 208-1DS-ANBK ARM: EAC5/2 PNIP3-ANBK POLE: DS340-R450V200-BK-HH-AB-P9/ WHATLEY D21M BLK POLE/ 208 E4 27W WALL DOWN LIGHT AT 10 FT AFF. FIXTURE TO MATCH EXISTING WALL LIGHTING IN BOZEMAN GATEWAY. NOTE: THESE LUMINAIRES ARE MOUNTED UNDER CANOPY. REFER TO ARCHITECTURAL ELEVATIONS. PROVIDE WITH 0-10V DIMMING FC LIGHTING FCW1039-120-LED4K-700-BK WALL/ 120 E5 15W 6" RECESSED DOWNLIGHT GOTHAM EVO6-30/15-AR-ND-LD RECESSED/ 120 L-2 5W/FT 2FT WALL MOUNT LUMINAIRE. WITH NARROW BEAM FOR WALL GRAZING EFFECT. SEE ARCHITECTURAL DRAWINGS FOR DETAILS.PINNACLE WET-8030STANDARD-FL-U-OL2 WALL/ 120 L-3 5W/FT LINEAR RECESSED LUMINAIRE MOUNTED IN CANOPY, REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LENGTHS.PINNACLE WET-8030STANDARD-FL-U-OL2 RECESSED/ 120 NOTE: CONTRACTOR MUST USE FIXTURES AND LUMINAIRES THAT MEET BOTH BOZEMAN MUNICIPAL CODE SECTION 38.570 AND THE BOZEMAN GATEWAY DESIGN MANUAL STANDARDS. TYPE E1/E2 LIGHT POLE ELEVATION (TYP)POLE BASE DETAIL (TYP) LONG REINF. SEE SCHEDULE ANCHOR BOLTS FROM POLE MANF.2'-6"7' HORIZ. TIES SEE SCHEDULE PROVIDE LONG AT ALL FOUR CORNERS OF SQUARE PIER. PROVIDE SPACING OF S/2 AT TOP 1'-0" OF PEIR. DEPTH BELOW FINISHED GRADE. SPACE LONG. STEEL EVENLY AROUND PERIMETER. PROVIDE REINF. CLEARANCE PER ANCI 318. * ** *** **** ***** 3"FINISH GRADE 24" SEE SITE PLAN FOR CONDUIT SIZE 1" CHAMFER REINFORCED CONC. BASE BY E.C. BUSH CONDUITS BASE COVER PROVIDE FUSE(S) IN CKT. TO BALLAST. FUSE(S) SHALL BE BUSS TYP. BBS. FUSE HOLDERS SHALL BE BUSS "TRON" HEB WATERPROOF. SIZE OF FUSE SHALL BE AS REQUIRED BY LUMINAIRE MANUFACTURER. CONNECT GROUND TO POLE BASE W/ BOUNDRY #GB4C PROJECT ANCHOR BOLTS 3" MIN. ABOVE TOP OF BASE. PROVIDE DOUBLE NUTS FOR LEVELING UNIT (ONE ABOVE AND ONE BELOW BASE FLANGE). GROUT VOID BETWEEN BASE FLANGE AND TOP OF CONCRETE, LEAVING DRAIN HOLE. HAND FINISH. THWN CONDUCTOR AS SHOWN ON PLANS PROVIDE 1' OF COILED SLACK ON CONDUCTOR FEED THRU HANDHOLE - 4" X 6" (NOMINAL) LIGHT FIXTURE BASE SCHEDULE ***** POLE HEIGHT SIZE LONG STL HORIZONTAL STL ** 14' - 30' DEPTH ***HEIGHT AFG 7'-0"3"24" Ø (6) # 6 ****#3 AT 12" O.C. NOTES: FURNISH PULL BOXES AND COVERS MADE OF POLYMER CONCRETE WITH FIBERGLASS REINFORCEMENT. FURNISH PULL BOXES HAVING CONTINUOUS FIBERGLASS CLOTH REINFORCEMENT ON THE INSIDE AND OUTSIDE PERIMETERS. FURNISH COVERS HAVING A MINIMUM OF TWO LAYERS OF FIBERGLASS CLOTH REINFORCEMENT. ENSURE THE PULL BOXES AND COVERS COMPLY WITH ALL TEST PROVISIONS OF THE MOST CURRENT ANSI/SCTE 77 FOR TIER 22 APPLICATIONS. FURNISH PULL BOXES AND COVERS THAT HAVE BEEN TESTED AND CERTIFIED BY A NATIONALLY RECOGNIZE D THIRD PARTY INDEPENDENT TEST FIRM SUCH AND UL OR ETL VERIFYING THAT THE BOXES AND COVERS MEET ALL TEST PROVISIONS OF THE ANSI/SCTE 77. FURNISH PULL BOXES THAT HAVE MARKINGS SHOWING THE TIER 22 RATING LABELED OR STENCILED ON THE INSIDE AND OUTSIDE OF THE BOX. FURNISH COVERS THAT MARKING SHOWING THE TIER 22 RATING EMBOSSED IN THE TOP SURFACE OF THE COVER. FURNISH COVERS HAVING PULL SLOTS RATED FOR A MINIMUM PULL OUT OF 3,000 POUNDS. FURNISH 3/8-7 LAB THREAD HEX HEAD BOLTS TO SECURE THE COVER TO THE PULL BOX.DL W 38" HOLD DOWN BOLTS 23"6"3" BACKFILL TOP 6" WITH EXCAVATED TOP SOIL MATERIAL AND TAMP SECURE ELECTRICAL BOND, NO.6 AWG COPPER OR EQUAL NO. 30 FELT PAPERSEPARATION CONDUIT IN PLACE AS REQUIRED. PROVIDE STUB AND CAPCONDUIT FOR FUTURELUMINAIRES 1" CLEAN STONE DRAINAGE CONCRETE POLYMERPULL BOX MINIMUMINSIDE DIMENSIONS TYPE I TYPE II TIER 22 RATED W = 12" L = 18" D = 12" W = 12" L = 24" D = 12" PULLBOX DETAIL