HomeMy WebLinkAboutAG001ProjectInformationTV 3 OC DD NL DB SD DB S S H F SPA CR T TIMER SWITCH TIMER SWITCH NOTES - TOILET/BATH ACCESSORIES: GR GUESTROOM AGR ACCESSIBLE GUESTROOM FOR TYPICAL TOILET/BATH ACCESSORY MOUNTING HEIGHTS, REFER TO THE G400 SERIES SHEETS. PROVIDE WOOD BLOCKING FOR ALL TOILET ACCESSORIES MOUNTED IN GYPSUM BOARD PARTITIONS TO RESIST 250 LBS OF PULL FORCE IN ANY DIRECTION. MAINTAIN INTEGRITY OF FIRE RATING WHERE ACCESSORIES ARE LOCATED IN RATED WALL. REFER TO TOILET/ACCESSORY SCHEDULE IN CONSTRUCTION SPECIFICATIONS FOR ALL APPROVED BATH AND TOILET ACCESSORY SPECIFICATIONS. EYEWASH SINK OPTIONAL AT POOL EQUIPMENT ROOM AND LAUNDRY ROOM. 1. 2. 3. 4. 5. MATERIALS LEGEND: RIGID INSULATION BATT INSULATION CONCRETE MASONRY SHAFT WALL CONCRETE WOOD STUD FRAMING RIGID ROOF INSULATION FINISHED WOOD EARTH BACKFILL PLYWOOD BRICK MASONRY WOOD BLOCKING GLASS GYPSUM BOARD GRANITE & SIMULATED STONE EIFS GENERAL NOTES - GUESTROOMS: REFER TO 1/8" BUILDING FLOOR PLANS FOR OVERALL GUESTROOM DIMENSIONS, UNO AND WINDOW OPENING LOCATION ON EXTERIOR WALLS. DIMENSIONS ARE FROM GRIDLINES AND FROM FACE OF STRUCTURE, UNO. DEIMISING WALLS AND LOAD BEARING WALLS ARE CENTERED ON GRIDLINES UNLESS OTHERWIDE DIMENSIONED. WHEN NOTED WITH "FOF" DIMENSIONS ARE FROM FACE OF FINISH. DOOR AND WINDOW DIMENSIONS WHERE OCCUR ARE FROM FACE OF STUD TO CENTERLINE OF OPENING. CENTER SPRINKLER HEADS IN SPACES. PROVIDE BLOCKING FOR WALL MOUNTED FIXTURES, ACCESSORIES, EQUIPMENT, AND WINDOW TREATMENTS, INCLUDING BUT NOT LIMITED TO TV, MIRROR, SAFE, & HEADBOARD. MAINTAIN INTEGRITY OF FIRE RATING WHERE ACCESSORIES ARE LOCATED IN RATED WALL. FOR TYPICAL MOUNTING HEIGHTS, REFER TO THE G400 AND A700 SERIES SHEETS. PLUMBING CHASES SHALL HAVE FIRESTOPS AT EACH FLOOR. MAINTAIN, BY CODE, MINIMUM REQUIRED SEPARATION BETWEEN GUESTROOMS AT PLUMBING CHASE WALLS. PROVIDE CARPET BASE TOE KICK UNDER PTAC UNITS. ALL ACCESSIBLE AND HEARING IMPAIRED UNITS TO HAVE STROBE & SOUND ACTIVATING DOORBELL WITH A 5 SECOND RING. PROVIDE DOORBELL ON/OFF SWITCH WITHIN GUESTROOMS, OR PER APPLICABLE CODE. CENTER LIGHT FIXTURES IN CEILING, UNO. ACC GUESTROOM ENTRY DOOR CLEARANCE WIDER THAN TYP GUESTROOM. SEE SHEET A601. GUESTROOM CEILING HEIGHTS, UNO: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. LEVEL 1 LEVEL 2+ LEVEL GUESTROOM BATHROOM 8' - 0" 7' - 6" 8' - 0" 7' - 6" 15. 16. 17. 18. PROVIDE WALLS WITH AN STC RATING OF 60 MIN AT CONDITIONS WHERE GUESTROOM HEADBOARD WALL ADJOINS WITH PUBLIC SPACE OR WITH ADJACENT GUESTROOM'S TV WALL. REFER TO THE A600 SERIES SHEETS FOR THE FINISH SCHEDULE. FOR ALL GUESTROOMS, PROVIDE A MINIMUM OF TWO POWER SOURCE OUTLETS THAT ARE OPEN AND ACCESSIBLE FROM THE BED(S), ADJACENT TO THE BED(S), FREE OF OBSTRUCTION, CLEARLY VISIBLE, AND DEDICATED TO THE GUESTS ON A COMPLIMENTARY BASIS. OUTLETS ALREADY BEING UTILIZED BY THE HOTEL FOR FF&E (LAMPS, RADIOS, ETC.) WHICH ARE NOT AVAILABLE FOR GUESTS USE WILL NOT MEET THIS REQUIREMENT. PROVIDE PTAC SLEEVE EXTENDING 16"-18" TO SHIELD DRAPERY FROM BILLOWING (TYPICAL). KITCHEN 8' - 0" 8' - 0" LIGHT / POWER LEGEND: WALL SCONCE - INTERIOR RECESSED FLUORESCENT 2' x 4' & 2' x 2' DRAPERY & DRAPERY TRACK RECESSED DOWNLIGHT ACCESS PANEL TO SPACE ABOVE J BOX INDICATES WALLWASHER FIXTURE INDICATES ACCENT FIXTURE SURFACED MOUNTED FIXTURE (DASHED INDICATES UNDERCABINET FIXTURE) SUSPENDED PENDANT FIXTURE STRIP FLOURESCENT FIXTURE (DASHED INDICATES COVE FIXTURE) TRACK LIGHTING MONOPOINT TRACK FIXTURE SUSPENDED INDIRECT/ DIRECT FIXTURE SUSPENDED INDIRECT FIXTURE FIRE SPRINKLER RECESSED SHOWER DOWNLIGHT DRAPERY FIXED PANEL DESK / TABLE / FLOOR LAMP GFI RECEPTACLE DUPLEX RECEPTACLE QUADPLEX RECEPTACLE FLOOR MOUNTED RECEPTACLE DIRECTIONAL EXIT LIGHT TELEPHONE CONNECTION COMPUTER / DATA OUTLET CABLE TV CONNECTION SINGLE POLE SWITCH THREE WAY SWITCH WALL MOUNTED OCCUPANCY SENSOR W/ SWITCH WALL MOUNTED DIMMABLE SWITCH WALL MOUNTED SWITCH W/ INTERNAL NIGHTLIGHT TURN OFF SWITCH FOR DOORBELL SMOKE DETECTOR DOORBELL LIGHT SPA TIMER FIRE ALARM STROBE DEVICE FIRE ALARM HORN & STROBE DEVICE & SMOKE DETECTOR FIRE ALARM HORN & STROBE DEVICE FIRE ALARM PULL STATION SPECIAL PURPOSE RECEPTACLE/WIRING CARD READER DUPLEX RECEPTACLE & TELEPHONE OUTLET WITH COMMON PLATE DUPLEX RECEPTACLE & TELCOM OUTLET WITH COMMON PLATE GFI RECEPTABLE & SINGLE POLE SWITCH WITH COMMON PLATE THERMOSTAT (REMOTE)OR WALL SCONCE - EXTERIOR DUPLEX RECEPTACLE WITH USB PORTS & TELCOM OUTLET WITH COMMON PLATE USB RECESSED CEILING SPEAKER TIMMER SWITCH FIRE PROTECTION FEATURES: STRUCTURAL ELEMENT FIRE RATING -STRUCTURAL FRAMING -1 HOUR -BEARING WALLS (INT & EXT) -1 HOUR -FLOOR CONSTRUCTION -1 HOUR -ROOF CONSTRUCTION -1 HOUR FIRE BARRIER FIRE RATING FIRE PARTITION FIRE RATING -STAIR WALLS -2 HOUR -SHAFTS -2 HOUR -CORRIDOR -1 HOUR -GUESTROOM SEPARATION -1 HOUR -OFFICE AREA -1 HOUR -GUESTROOM SHEAR WALLS -1 HOUR SPRINKLER SYSTEM: EACH BUILDING SHALL BE EQUIPPED THROUGHOUT WITH A SUPERVISED AUTOMATIC SPRINKLER SYSTEM DESIGNED AND INSTALLED TO MEET ALL APPLICABLE STATE AND LOCAL BUILDING CODES. PLANS AND SPECIFICATIONS OF SPRINKLER SYSTEM SHALL BE SUBMITTED FOR AUTHORITY HAVING JURISDICTION REVIEW AND APPROVAL PRIOR TO CONSTRUCTION. THE ATTIC SPACES OF THE BUILDINGS ARE TO BE FULLY SPRINKLERED WITH A DRY PIPE SYSTEM. THIS SYSTEM SHALL BE A FULLY AUTOMATIC MONITORED SYSTEM AND THE SYSTEM SHALL SUPERCEDE THE REQUIREMENTS FOR ATTIC DRAFT STOPPING PARTITIONS, BUT NOT AREA SEPARATION PARTITIONS. IN ADDITION TO THE BUILDING, THE PORT COCHERE SHALL ALSO BE SPRINKLERED. PROGRAM AREA SUMMARY (GSF): 113 ROOM, 4 STORY FIRST FLOOR –15,782 SF SECOND FLOOR –15,442 SF THIRD FLOOR –15,442 SF FOURTH FLOOR – 15,442 SF TOTAL AREA –62,108 SF ROOM TYPE 1ST 2ND 3RD TOTAL %4THROOM TYPE 1ST 2ND 3RD TOTAL %4TH 1. (7) TOTAL HANDICAPPED ACCESSIBLE ROOMS SHALL BE PROVIDED. OF THE NUMBER OF REQUIRED ACCESSIBLE ROOMS (1) SHALL HAVE A ROLL-IN SHOWER WITH PERMANENTLY MOUNTED FOLDING SHOWER SEAT. 2. (12) TOTAL HEARING IMPARED ROOMS SHALL BE PROVIDED. GUESTROOM MIX: KING SUITE 11 17 17 62 55%17 DOUBLE QUEEN SUITE 6 11 10 37 32%10 1 2 2 7 6%2 0 0 1 2 2%1 ACC KING SUITE 2 1 1 0 2 2%0 ACC DOUBLE QUEEN SUITE GUESTROOM AREAS: *GROSS SQUARE FOOTAGE MEASURED FROM INTERIOR FINISH FACE OF DEMISING WALLS AND EXTERIOR WALLS. TOTAL 1 0 0 1 1%0 20 31 31 113 100%31 ACC 1-BEDROOM SUITE ACC KING SUITE 1 1-BEDROOM SUITE 0 0 1 2 2%1 ROOM TYPE GSF*ROOM TYPE KING SUITE 324 SF DOUBLE QUEEN SUITE 405 SF 658 SF 513 SF ACC KING SUITE 2 558 SF ACC DOUBLE QUEEN SUITE ACC 1-BEDROOM SUITE ACC KING SUITE 1 1-BEDROOM SUITE 558 SF 658 SF GENERAL NOTES - FINISHES: INSTALL ALL FINISHES PER MANUFACTURERS INSTRUCTIONS. PREPARE ALL FLOOR AND WALL SURFACES FOR NEW FINISHES. PROVIDE FLOOR LEVELING AS REQUIRED TO INSURE PROPER INSTALLATION OF PRODUCT(S). ALL FLOORING MATERIALS TRANSITIONS SHALL OCCUR AT THE CENTERLINE OF DOORS SEPARATING ROOMS, UNO. DOOR THRESHOLD REQUIREMENTS TO BE COORDINATED WITH DOOR HARDWARE SPECIFICATIONS. FINISHES IN ACCESSORY SPACES TO MATCH ADJACENT SPACES, UNO. 1. 2. 3. 4. GENERAL NOTES - FF&E: FOR TYPICAL MOUNTING HEIGHT, REFER TO THE G400 AND A700 SERIES SHEETS. PROVIDE BLOCKING FOR WALL MOUNTED FIXTURES, ACCESSORIES & EQUIPMENT. REFER TO THE A600 SERIES SHEETS FOR THE FINISH SCHEDULE. FOR FINISH PRODUCT DETAILS, REFER TO FF&E SPECIFICATIONS. 1. 2. 3. 4. GENERAL NOTES - FLOOR PLANS: WOOD BEARING WALLS ARE ASSUMED TO BE 2X6. DIMENSIONS ARE FROM GRIDLINES AND FROM FACE OF STRUCTURE, UNO. DEMISING WALLS AND LOAD BEARING WALLS ARE CENTERED ON GRIDLINES UNLESS OTHERWIDE DIMENSIONED. WHEN NOTED WITH "FOF" DIMENSIONS ARE FROM FACE OF FINISH. DOOR AND WINDOW DIMENSIONS WHERE OCCUR ARE FROM FACE OF STUD TO CENTERLINE OF OPENING. HINGES SIDE OF DOOR TO BE LOCATED 4" FROM ADJACENT WALL, UNO. SWING DOORS & FRAMES SHALL BE INSTALLED AS SHOWN BELOW, UNO. REFERENCE DOOR AND WINDOW MANUFACTURERS' SPECIFICATIONS FOR ACTUAL ROUGH OPENING SIZE. DOOR IN PATH OF EGRESS SHALL BE EQUIPPED WITH HARDWARE COMPLYING WITH CHAPTER 10 OF THE 2015 INTERNATIONAL BUILDING CODE AND ANY APPLICABLE CODES. DOOR REQUIRED TO BE ACCESSIBLE SHALL BE EQUIPED WITH HARDWARE COMPLYING WITH ICC/ANSI STANDARD 117.1 AND ANY APPLICABLE CODES. TO THE MAXIMUM EXTENT POSSIBLE, FLOOR CLEAN OUTS ARE TO BE LOCATED IN INCONSPICUOUS PLACES AND NOT IN GUESTROOMS. ALL FLOOR CLEAN OUTS LOCATED IN CARPETED AREAS ARE TO BE FITTED WITH CARPET INSERTS. ALL CLEANOUTS ARE TO BE FLUSH TO FLOOR/WALLS. ALIGN FINISHES WHERE DISSIMILAR WALL TYPES MEET, UNO. PROVIDE WALLS WITH AN STC RATING OF 60 MIN AT CONDITIONS WHERE GUESTROOM HEADBOARD WALL ADJOINS WITH PUBLIC SPACE OR WITH ADJACENT GUESTROOM'S TV WALL. PROVIDE ELECTRICAL OUTLETS IN UNIT ENTRY CORRIDOR AT 30' - 0" O.C. SWITCHING WALLS AT EVERY OTHER OUTLET. PROVIDE BLOCKING AT HARDWARE ATTACHMENT POINTS FOR ALL SLIDING DOORS. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 1' - 6" MIN 1' - 0" MIN 4" STD GENERAL NOTES - RCP: FOR ENLARGED PUBLIC SPACE, BACK OF HOUSE & GUESTROOM RCPS, REFER TO THE A500 SERIES SHEETS. CENTER ACOUSTIC CEILING GRID IN SPACE, UNO. CENTER RECESSED DOWN LIGHTS IN ACOUSTIC CEILING AT CORRIDORS. CENTER LIGHT FIXTURES IN SOFFITS AND IN ROOMS, UNO. ALL WALLS EXTEND TO BOTTOM OF STRUCTURE, UNO. CENTER VANITY FIXTURES OVER LAVATORY, UNO. COORDINATE FIXTURE INSTALLATIONS WITH ENGINEERING SYSTEMS. CENTER SMOKE DETECTORS IN ACOUSTIC CEILING TILES, WHERE OCCURS. CENTER SPRINKLER HEADS IN ACOUSTIC CEILING TILES, WHERE OCCURS. PAINT ALL DIFFUSERS TO MATCH ADJACENT FINISHES, UNO. CENTER CEILING MOUNTED SPEAKERS IN ACOUSTIC CEILING TILES, WHERE OCCURS. PROVIDE TEGULAR STYLE ACT IN ALL PUBLIC SPACE AREAS (TYPICAL). 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. GENERAL NOTES - ROOF PLAN: ALL SLOPES INDICATED FOR FLAT ROOF AREAS TO BE 1/4" PER FOOT MIN. PROVIDE ATTIC, ROOF AND PARAPET VENTILATION AS REQUIRED PER THE APPLICABLE CODE. PROVIDE ELEVATOR SHAFT AND LAUNDRY CHUTE VENTS AS REQUIRED BY AUTHORITY HAVING JURISDICTION. 1. 2. 3. RCP LEGEND: ACT - 2'-0" x 2'-0" (PUBLIC AREAS - TEGULAR) ACT - 2'-0" x 2'-0" CLEANABLE (BACK OF HOUSE - SQUARE EDGE) ACT - 2'-0" x 4'-0" (BACK OF HOUSE SQUARE EDGE) GYPSUM BOARD TEXTURED FINISH SLOT DIFFUSER (S, R INDICATES SUPPLY, RETURN) SUPPLY s SPRINKLER HEAD (CENTER IF LOCATED IN ACT TILE) SUPPLY RETURN DIFFUSER RETURN DIFFUSER GYPSUM BOARD SMOOTH FINISH GENERAL NOTES - EXTERIOR ELEVATIONS: FINISH OF ALL PTAC/VTAC LOUVERS TO MATCH ADJACENT FACADE MATERIAL FINISH UNO. FINISH OF ALL MECHANICAL LOUVERS AND APPURTENANCES TO MATCH ADJACENT FACADE MATERIAL FINISH UNO. SEE ENLARGED ELEVATION FOR TYPICAL PANEL JOINT LOCATIONS 1. 2. 3. SHEET NO. PROJECT NO. SHEET TITLE: REVISIONS / ISSUES DRAWN BY: PROFESSIONAL SEAL DATE: CHECKED BY: PROJECT: PROJECT ADDRESS COPYRIGHT AND OWNERSHIP OF DOCUMENTS NOTICE CONSULTANTS ARCHITECT OF RECORD: 8400 E. CRESCENT PARKWAY, SUITE 160 GREENWOOD VILLAGE, CO 80111 Tel: 720-881-1600 WWW.101ARCHITECTURE.COM ARCHITECTURE PLANNING INTERIOR DESIGN THIS DRAWING WAS PREPARED FOR A SPECIFIC USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH ITS ISSUE DATE AND IT IS NOT TO BE USED ON A DIFFERENT PROJECT. THIS DRAWING IS AN INSTRUMENT OF PROFESSIONAL SERVICE AND IS PROTECTED BY COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING COPYRIGHT. IT MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE WRITTEN CONSENT OF THE DESIGN PROFESSIONAL©2020 INDEX & PROJECT INFORMATION G-001 21-101A014 01/24/2022 EVERHOME SUITES - BOZEMAN 959 FOWLER AVENUE BOZEMAN, MT 59718 BG FM SITE PLAN PACKAGE NO. DESCRIPTION DATE BUILDING CODE: MECHANICAL CODE: ELECTRICAL CODE: PLUMBING CODE: ENERGY CODE: FIRE PROTECTION: FUEL GAS CODE: ACCESSIBILITY: ELEVATOR CODE: 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL MECHANICAL CODE 2017 NATIONAL ELECTRICAL CODE (NFPA 70) 2018 INTERNATIONAL PLUMBING CODE 2018 INTERNATIONAL ENERGY CONSERVATION CODE 2018 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL FUEL GAS CODE 2009 ICC A117.1 ACCESSIBILITY STANDARD ASME A17.1 -2013 SAFETY CODE FOR ELEVATORS & ESCALATORS ASME A17.3 -2013 SAFETY CODE FOR EXISTING ELEVATORS & ESCALATORS APPLICABLE CODES