Loading...
HomeMy WebLinkAboutA201aElevationsFront&RearLEVEL 1 0" LEVEL 2 10' -0" LEVEL 3 20' -0" TRUSS BEARING 38' -2" 8 7910 11121314151 61720 619 5 4 2 LEVEL 4 30' -0" 18 3 12221 14 13 12 4 4 3 7 1 2 55 5 5 6 6 6 6 6 7 7 222 3 3 3 4 4 4 4 1 4 7 7 4 12 1 12 1 7 13 15 15 12 ART MURAL 13 15 12 12 L-2 LINEAR WALL WASH LIGHT, TYP. FOR CORTEN FINS L1 L-1 L-2 TYP10' - 0"L1 L-2 L-1 THRU-WALL SCUPPER (TYP.) THRU-WALL SCUPPER (TYP.) 61' - 5" A-201.c 1 RECESSED 6'-4" 27' - 0 1/4" 27' - 10 3/4" RECESSED 6'-4" 26' - 1 1/4" 24' - 4 1/8" 4' - 0" 13' - 4 1/4" RECESSED 6'-4" 25' - 9 5/8" 27' - 10 3/4" RECESSED 6'-4" 26' - 1 1/4" 27' - 10 3/4" RECESSED 6'-4" 20' - 8"1' - 6"1' - 6"2' - 2"3' - 4"2' - 6"3' - 0"1' - 6"1' - 6"1' - 6"9' - 10"7' - 5"5' - 6"1' - 7 1/2" 3' - 6 5/8" 4' - 0"9' - 6"4' - 0" 1' - 6" 3' - 8 5/8"1' - 7 1/2" 3' - 6 5/8" 4' - 0"9' - 6"4' - 0" 1' - 6" 3' - 8 5/8" 11' - 3 3/8" 13' - 6" 1' - 3 7/8"10' - 11 3/4"13' - 6"1' - 3 7/8"11' - 3 3/8" 13' - 6" 1' - 3 7/8" TYP 3' - 0" 1' - 7 1/2" 3' - 6 5/8" 4' - 0"9' - 6"4' - 0" 1' - 6" 3' - 8 5/8" 12' - 2 3/8" 13' - 6" 1' - 3 7/8" BLANK WALL 12' - 11 3/4" 16 4 7 14 17 17 17 MECH LOUVER LEVEL 1 0" LEVEL 2 10' -0" LEVEL 3 20' -0" TRUSS BEARING 38' -2" 87 9 10 11 12 13 14 15 1 6 17 20619542 LEVEL 4 30' -0" 18 3 1 2221 2 3 1 2 10 3 105 1 7 44 4 4 4 44 4 1111 10 3 3 3 7 15 6 6 65 5 5 7 12 13 15 12 11 10 7 13 15 33 3 2 7 13 15 L-2 LINEAR WALL WASH LIGHT, TYP. FOR CORTEN FINS L-1 L-1 L-2 14 L-1 L-1 L-2 10 4 61' - 5" 16 5' - 0" 9' - 7 7/8" RECESSED 6'-4" 63' - 4"27' - 10 3/4" RECESSED 6'-4" 26' - 1 1/4" 26' - 8 5/8" 4' - 0" 10' - 10 1/2" 10' - 3 5/8" RECESSED 6'-4" 57' - 0"9' - 4 1/4" 6' - 6"3' - 0"15' - 9"2' - 2 5/8"13' - 6"13' - 6"13' - 6"24' - 7"11' - 3 3/8" 13' - 6"1' - 3 7/8"24' - 0 5/8" 10' - 11 1/2" 13' - 6" 13' - 6" 1' - 3 7/8" 3' - 8 5/8" 1' - 6" 4' - 0"9' - 6"4' - 0" 3' - 6 5/8" 1' - 7 1/2"1' - 6"1' - 6"2' - 2"3' - 4"2' - 6"3' - 0"2' - 2"3' - 4"GAS METER4' - 0"FIXED WINDOW ELEC METER GENERAL NOTES - EXTERIOR ELEVATIONS: FINISH OF ALL PTAC/VTAC LOUVERS TO MATCH ADJACENT FACADE MATERIAL FINISH UNO. FINISH OF ALL MECHANICAL LOUVERS AND APPURTENANCES TO MATCH ADJACENT FACADE MATERIAL FINISH UNO. SEE ENLARGED ELEVATION FOR TYPICAL PANEL JOINT LOCATIONS 1. 2. 3. SHEET NO. PROJECT NO. SHEET TITLE: REVISIONS / ISSUES DRAWN BY: PROFESSIONAL SEAL DATE: CHECKED BY: PROJECT: PROJECT ADDRESS COPYRIGHT AND OWNERSHIP OF DOCUMENTS NOTICE CONSULTANTS ARCHITECT OF RECORD: 8400 E. CRESCENT PARKWAY, SUITE 160 GREENWOOD VILLAGE, CO 80111 Tel: 720-881-1600 WWW.101ARCHITECTURE.COM ARCHITECTURE PLANNING INTERIOR DESIGN THIS DRAWING WAS PREPARED FOR A SPECIFIC USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH ITS ISSUE DATE AND IT IS NOT TO BE USED ON A DIFFERENT PROJECT. THIS DRAWING IS AN INSTRUMENT OF PROFESSIONAL SERVICE AND IS PROTECTED BY COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING COPYRIGHT. IT MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE WRITTEN CONSENT OF THE DESIGN PROFESSIONAL©2020 ELEVATIONS -FRONT & REAR A-201.a 21-101A014 01/24/2022 EVERHOME SUITES - BOZEMAN 959 FOWLER AVENUE BOZEMAN, MT 59718 BG FM SITE PLAN PACKAGE NO. DESCRIPTION DATE 1" = 10'-0"1 EAST ELEVATION 1" = 10'-0"2 WEST ELEVATION KEYNOTE LEGEND - EXTERIOR ELEVATIONS NUMBER MATERIAL COLOR NOTESHERWIN WILLIAMS 1 STUCCO SNOWBOUND - 7004 / 256-C2 PTD 2 STUCCO MINUTE MAUVE - 7078 / 227-C1 PTD 3 STUCCO QUEST GRAY - 7080 / 227-C3 PTD 4 STUCCO PERLE NOIR - 9154 / 226-C7 PTD 5 BRICK VENEER STACK BOND - EBONITE VELOUR GLEN GERY OR SIMILAR 6 BRICK VENEER STACK BOND - ASPEN WHITE GLEN GERY OR SIMILAR 7 AZP CORTEN PANEL -METAL PANEL SYSTEM 9 MAN DOOR AND DOOR FRAME -PTD TO MATCH ADJACENT WALL COLOR 10 VINYL WINDOW FRAME -EQUIVALENT TO MILGARD : BLACK 11 THRU-WALL SCUPPER BOX -PTD TO MATCH ADJACENT WALL COLOR 12 ALUMINUM COPING DARY GRAY PREFINISHED 13 ACM PANEL DARY GRAY FASCIA & SOFFIT 14 ALUMINUM STOREFRONT SYSTEM DARY GRAY PREFINISHED ANNODIZED ALUMINUM 15 PAINTED STEEL SNOWBOUND - 7004 / 256-C2 PTD 16 RENAISSANCE STONE SMOOTH NUTMEG ARRISCRAFT 17 SPANDREL GLAZING -PREFINISHED ANNODIZED ALUMINUM TRANSPARANCY CALCULATION FOWLER STREET FACADE REQUIRED:15% OF ENTIRE FACADE =11,711 SF FOWLER STREET FACADE PROVIDED:1,782.15 SF = 1,782.15/11,711(100) = 15.22%