Loading...
HomeMy WebLinkAboutL-300_PP-LANDSCAPE DETAILS_2020-08-06OWNER: DATE: SHEET TITLE: OWNER: DATE: SHEET TITLE: CH E C K E D B Y : DR A W N B Y : NO R T H W E S T C R O S S I N G S U B D I V I S I O N TR A C T 5 N E 4 CI T Y O F B O Z E M A N , M T PR E L I M I N A R Y P L A T BRYAN KLEIN NWX, LLC PO BOX 11890 BOZEMAN, MT 59719 P 409.582.8100 ARXX 04/03/20: PRELIM PLAT 08/06/20: PRELIM PLAT 02 NOT FOR CONSTRUCTION 244 North College Avenue #130 Fort Collins, Colorado 80524 P 970.409.3414 www.norris-design.com LANDSCAPE DETAILS L-300 2X ROOT BALL DIAMETER 120° 120° PRUNING NOTES: 1.ALL PRUNING SHALL COMPLY WITH ANSI A300 STANDARDS. 2.DO NOT HEAVILY PRUNE THE TREE AT PLANTING. PRUNE ONLY CROSSOVER LIMBS, CO-DOMINANT LEADERS AND BROKEN BRANCHES. SOME INTERIOR TWIGS AND LATERAL BRANCHES MAY BE PRUNED. HOWEVER, DO NOT REMOVE THE TERMINAL BUDS OF BRANCHES THAT EXTEND TO THE EDGE OF THE CROWN. STAKING NOTES: 1.STAKE TREES PER FOLLOWING SCHEDULE, THEN REMOVE AT END OF FIRST GROWING SEASON. a.1-1/2" CALIPER SIZE - MIN. 1 STAKE ON SIDE OF PREVAILING WIND (GENERALLY N.W. SIDE). b.1-1/2" - 3" CALIPER SIZE - MIN. 2 STAKES - ONE ON N.W. SIDE, ONE ON S.W. SIDE (OR PREVAILING WIND SIDE AND 180° FROM THAT SIDE). c.3" CALIPER SIZE AND LARGER - 3 STAKES PER DIAGRAM. 2.WIRE OR CABLE SHALL BE MIN. 12 GAUGE, TIGHTEN WIRE OR CABLE ONLY ENOUGH TO KEEP FROM SLIPPING. ALLOW FOR SOME TRUNK MOVEMENT. NYLON STRAPS SHALL BE LONG ENOUGH TO ACCOMMODATE 1-1/2" OF GROWTH AND BUFFER ALL BRANCHES FROM WIRE. TREE PLANTING DETAIL SCALE: 3/16" = 1'-0" 1 2 3 4 5 6 7 14 13 12 11 10 9 8 PLACE MINIMUM 1/2" PVC PIPE AROUND EACH WIRE, EXPOSED WIRE SHALL BE MAXIMUM 2" EACH SIDE 6'-0"UNTREATED WOOD POST, MINIMUM 1.5" DIAMETER, ALL SHALL BE DRIVEN OUTSIDE ROOTBALL AND IN UNDISTURBED SOIL TREE WRAP TO BE INSTALLED ONLY FROM OCTOBER 1 THROUGH APRIL 30, DECIDUOUS ONLY, WRAP FROM BASE OF TRUNK TO BOTTOM LIMB PLANT TREE SO THAT TOP MOST MAJOR ROOT IS 1"-2" ABOVE FINISHED GRADE 2'-0" RADIUS MULCH RING, VENTERED ON TRUNK, 3" DEPTH, DO NOT PLACE MULCH IN CONTACT WITH TREE TRUNK, FINISHED GRADE REFERENCES TOP OF MULCH 1:1 SLOPE ON SIDES OF PLANTING HOLE ROPES AT TOP OF ROOTBALL SHALL BE CUT, REMOVE TOP 1/3 OF BURLAP, NON-BIODEGRADABLE MATERIAL SHALL BE TOTALLY REMOVED GROMMETED NYLON STRAPS GALVANIZED WIRE, MINIMUM 12 GAUGE CABLE,TWIST WIRE ONLY TO KEEP FROM SLIPPING 4-6" HIGH WATER SAUCER IN NON-TURF AREAS BACKFILL WITH BLEND OF EXISTING SOIL AND A MAXIMUM 20%, BY VOLUME, ORGANIC MATERIAL, WATER THOROUGHLY WHEN BACKFILLING 2'-0" STEEL T-POST, ALL SHALL BE DRIVEN BELOW GRADE AND OUTSIDE ROOTBALL IN UNDISTURBED SOIL PLACE SOIL AROUND ROOT BALL FIRMLY, DO NOT COMPACT OR TAMP, SETTLE SOIL WITH WATER TO FILL ALL AIR POCKETS PLACE ROOT BALL ON UNDISTURBED SOIL TO PREVENT SETTLEMENT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 PLAN VIEW - THREE STAKES P R E V A I L I N G W I N D 2'-6" WOODEN STAKE DRIVEN INTO THE GROUND NEXT TO ROOTBALL, 18" OF THE STAKE MUST BE VISIBLE SET SHRUB ROOTBALL 1" HIGHER THAN FINISH GRADE FINISH GRADE (TOP OF NATIVE SEED) SPECIFIED NATIVE SEED TILL SPECIFIED SOIL AMENDMENT TO A DEPTH OF 8" UNDISTURBED GRADE 1 2 3 4 5 6 SHRUB PLANTING IN NATIVE AREAS SCALE: 1 1/2" = 1'-0" NOTES: 1.BROKEN OR CRUMBLING ROOT-BALLS WILL BE REJECTED. 2.CARE SHOULD BE TAKEN NOT TO DAMAGE THE SHRUB OR ROOT-BALL WHEN REMOVING IT FROM ITS CONTAINER. 3.ALL JUNIPERS SHOULD BE PLANTED SO THE TOP OF THE ROOT-BALL OCCURS ABOVE THE FINISH GRADE OF THE MULCH LAYER. 4.DIG PLANT PIT TWICE AS WIDE AND AS HIGH AS THE CONTAINER. 5.PRUNE ALL DEAD OR DAMAGED WOOD PRIOR TO PLANTING, DO NOT PRUNE MORE THAN 20% OF LIMBS. 2X CONTAINER WIDTH 1X CONTAINER HEIGHT 4 5 6 3 2 1 1/2" THICK 6'-0" x 3'-0" WEATHERED STEEL TREE GRATE - 2 SECTIONS ANCHOR BOLT STEEL ANGLE INTO HARDSET EDGE OF PORCELAIN PAVERS 4"X4" STEEL ANGLE SUPPORT ADJACENT CONCRETE; REFER TO CIVIL FINISH GRADE BACKFILL WITH PLANTING SOIL MIX - SEE SPECIFICATIONS COMPACTED SUBGRADE IN GRADE UPLIGHT - SEE LIGHTING PLAN THICKENED CONCRETE CURB (2) #4 REBAR, CONTINUOUS CAST IRON TRUNK GUARD 1 2 3 4 5 6 7 8 9 10 11 TREE GRATE SCALE: 1" = 1'-0" FLUSH 6'-0" TYP. FLUSH 2'-0" DIA. NOTES: 1. ALL STEEL AND HARDWARE TO BE PRE-WEATHERED AND SEALED TO PREVENT STAINING. 2. TREE LAYOUT REQUIRED TO ASSURE PLANTING IN CENTER OF GRATE. 3. GRATE TO BE INSTALLED AFTER TREE. 4. TREE TO BE MULCHED AND STAKED PER 1/L-300 4" TYP. 2 3 6 7 8 9 6" MINIMUM 1'-0" MINIMUM 5951 10 11 1 2 3 4 COMPACTED, STABILIZED CRUSHER FINES, 1/4" MINUS AGGREGATE BASE SUBGRADE COMPACTED PER NOTES AND SPECIFICATIONS. 4" ROLL TOP STEEL EDGER, FLUSH WITH SURROUNDING GRADE SLOPE ADJACENT GRADE AWAY FROM TRAIL 1 2 3 4 5 CRUSHER FINES TRAIL WITH EDGER SCALE: 3/4" = 1'-0" NOTES: 1.COMPACT CRUSHER FINES WET, COMPACT TO 95% STANDARD PROCTOR DENSITY. 2.USE A SMALL 4' RIDING ROLLER TO COMPACT TRAIL. 3.CROWN OF 2% IN FLAT AREAS AS SHOWN. 4.CROSS SLOPE TRAIL AT 1-2% WITH GRADE WHERE TOPOGRAPHY DICTATES. 5.APPLY STABILIZER/TACKIFIER TO CRUSHER FINES SURFACE. 1 2 54 3" MINIMUM WIDTH VARIES, SEE PLANS 4" 3