Loading...
HomeMy WebLinkAboutLS4.1_Irrigation Details_1-21-2020TH I S D R A W I N G I S T H E I N T E L L E C T U A L P R O P E R T Y O F I N - S I T E D E S I G N G R O U P . D O N O T C O P Y O R R E P R O D U C E I N A N Y W A Y W I T H O U T T H E E X P R E S S W R I T T E N P E R M I S S I O N O F I N - S I T E D E S I G N G R O U P . C O P Y R I G H T © 2 0 0 6 ar c h i t e c t s @ i n - s i t e d e s i g n g r o u p . c o m 17 N o r t h 4 7 0 W e s t A m e r i c a n F o r k , U t a h 8 4 0 0 3 80 1 . 7 5 6 . 5 0 4 3 w w w . i n - s i t e d e s i g n g r o u p . c o m 4- 1 4 - 2 0 2 0 T Co r y B . Wh i t i n g # 1 0 6 2 9 CETIHCRA EPACSDN A L D E S N E C I L CI T Y S U B M I T T A L 45 5 5 F A L L O N S T . B O Z E M A N , M T 5 9 7 1 5 PH A S E B IC O N A T F E R G U S O N F A R M DE T A I L S IR R I G A T I O N LS4.1 19-143 1-21-2020 CBW JES CONDUIT, FITTINGS AND SWEEP ELL OUT TO RAINBIRD RAIN SENSOR. CONDUIT, FITTINGS AND SWEEP ELL TO POWER SUPPLY WALL MOUNTED RAINBIRD CONTROLLER. CONDUIT, FITTINGS AND SWEEP ELL OUT TO ADJACENT LAWN OR PLANTER AREA FOR VALVE CONNECTIONS. NOTES: 1.MOUNT CONTROLLER PER MANUFACTURER'S WRITTEN INSTRUCTIONS AND IN ACCORDANCE WITH ALL LOCAL CODES. EXACT LOCATION TO BE APPROVED BY OWNER. GROUND CONTROLLER PER MANUFACTURERS RECOMMENDATION AND SPECIFICATIONS. ELECTRICAL CONTRACTOR SHALL GROUND CONTROLLER. LANDSCAPE CONTRACTOR SHALL PROVIDE SLEEVING FROM ADJACENT PLANTER AREA TO CONTROLLER LOCATION. 2.CONNECT CONTROLLER TO POWER AND VALVES. 3.REFER TO SPECS FOR ADDITIONAL INFORMATION. 4.MOUNT SENSOR WITH IN 25 FEET OF CONTROLLER PER MANUFACTURER RECOMMENDATIONS. CONTROLLER WITH SENSOR SCALE: NTS1 PVC SCH 40 FEMALE ADAPTER PVC MAINLINE FINISH GRADE. TOP OF MULCH / ROCK ID TAG: PRE-PRINTED. PVC LATERAL PVC SCH 80 NIPPLE (2-INCH LENGTH, HIDDEN) AND PVC SCH. 80 TEE OR ELL. 3-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL VALVE BOX WITH COVER. WATER PROOF CONNECTION: RAIN BIRD SPLICE-1 (1 OF 2) OR DBY/R. 30-INCH LINEAR LENGTH OF WIRE, COILED PVC SCH 80 NIPPLE (TYPICAL, LENGTH AS REQUIRED) PVC SCH 80 ELL. RAIN BIRD 1" XCZ-PRB-100-COM CONTROL ZONE KIT. (INCLUDES 1" BALL VALVE WITH 1" PESB VALVE AND 1" PRESSURE REGULATING (40PSI) BASKET FILTER) 3" MIN. 1" DRIP CONTROL ZONE KIT SCALE: NTS BRICK (1 OF 4). NOT REQUIRED IF RAINBIRD BOX IS USED. 2 FINISH GRADE 1 CUBIC FOOT PEA GRAVEL SUMP VALVE BOX WITH COVER PVC BALL VALVE, SIZE PER LINE. 24" EXTRA LENGTH OF AR 1/2" OR 3/4" TUBING (AVAILABLE THRU GPH PRODUCTS) LINE COILED IN VALVE BOX. INSTALL MISC. FITTINGS AS REQUIRED. DRIP LINE FLUSH CAP SCALE: NTS BRICK (1 OF 4) REQUIRED IF RAINBIRD VALVE BOX IS NOT USED. NOTES: 1.USE IPS WELDON 795 GLUE AND P70 PRIMER PER GPH INC. SPECIFICATIONS. 2.DO NOT INSTALL PIPE, FITTINGS, OR GLUE IN TEMPERATURES BELOW 40 DEGREES. SEE MANUFACTURER SPECIFICATIONS FROM MORE INFORMATION. 3 NOTES: 1.EMITTER SPACING SHALL BE BASED ON PLANT SPACING. INSTALL ALL IRRIGATION USING THE COMPONENTS DESCRIBED ABOVE. 2.IRRIGATION EQUIPMENT SHALL BE COMPLETELY INSTALLED PRIOR TO PLANT LAYOUTS. 3.ADJUST IRRIGATION SPACING TO ACCOMMODATE FINAL PLANT LAYOUT. 4.1/2" PVC FLEX HOSE SHALL NOT EXCEED 4GPM, 3/4" PVC FLEX HOSE SHALL NOT EXCEED 8GPM AND 1" PVC FLEX HOSE SHALL NOT EXCEED 13GPM. 5.AT OWNERS DISCRETION, A LESS EXPENSIVE DRIP SYSTEM MAY BE INSTALLED. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS, SUBMITTAL CUT SHEETS AND POTENTIAL COST SAVINGS TO OWNER. HOWEVER, THE OWNER AND LANDSCAPE ARCHITECT MUST APPROVE ALL CHANGES IN MATERIALS AND CONSTRUCTION PRACTICES IF DIFFERENT FROM THE PLAN. 6.SMALL EVERGREEN TREES MAY NEED FEWER EMITTERS. CONSULT WITH THE LANDSCAPE ARCHITECT ON-SITE PRIOR TO INSTALLING IRRIGATION TO DETERMINE QUANTITY OF EMITTERS. 7.SEE IRRIGATION SHEET FOR DRIP EMITTER LEGEND. 8.USE IPS WELDON 795 GLUE AND P70 PRIMER PER GPH INC. SPECIFICATIONS. 9.DO NOT INSTALL PIPE, FITTINGS, OR GLUE IN TEMPERATURES BELOW 40 DEGREES. SEE MANUFACTURER SPECIFICATIONS FROM MORE INFORMATION. PVC SCH 40, OR STICKY-STRIP PVC HOSE BY GPH. SIZE PER PLAN. PVC 34" TO 12" REDUCTION TEE. SHRUB, PERENNIAL OR GRASS, TYP. SEE PLANTING PLAN AND EMITTER LEGEND. 12 TO 1" FLEXIBLE PVC HOSEMANUFACTURED BY GPH. CONTRACTOR SHALL SIZE PER NOTE #4. SPEC-CHECK PC CHECK VALVE EMITTER, TYP. SCHEDULE 40 CROSS. GLUE FITTING. SCHEDULE 40 TEE. GLUE FITTING. VARIES PER PLAN MAX. 5' GPH DRIP EMITTER PLAN VIEW SCALE: NTS ROOTBALL, TYP. FOR PLANTS REQUIRING ONLY ONE EMITTER, INSTALL THE EMITTER AT THE EDGE OF THE ROOTBALL. FOR PLANTS REQUIRING TWO EMITTERS, INSTALL ONE EMITTER AT THE EDGE OF THE ROOTBALL AND THE OTHER ON THE OPPOSITE SIDE OF THE ROOTBALL HALFWAY BETWEEN THE PLANT'S TRUNK AND IT'S EXPECTED MATURE CANOPY. FOR TREES, INSTALL 3 EMITTERS. INSTALL (2) 4-GAL EMITTERS AT THE EDGE OF THE ROOTBALL ON OPPOSITE SIDES OF THE TREE AND THE OTHER 2-GAL. EMITTER SPREAD OUT TO PROMOTE FUTURE ROOT GROWTH. EXPECTED MATURE CANOPY, TYP. 5 NOTE: 1.FOR LAYOUT OF MULTIPLE SHRUBS, CONTRACTOR SHALL USE TEE'S AS NECESSARY. 2.USE IPS WELDON 795 GLUE AND P70 PRIMER PER GPH INC. SPECIFICATIONS. 3.DO NOT INSTALL PIPE, FITTINGS, OR GLUE IN TEMPERATURES BELOW 40 DEGREES. SEE MANUFACTURE SPECIFICATIONS FROM MORE INFORMATION. TOP SOIL 60" LONG MAXIMUM14" LONG MINIMUM 1/2" FLEX TUBING DRIP EMITTER WITH FINISH GRADE PLANT OR TREE ROOTBALL 12" GLUEDON MALE ADAPTER FPT BASE PVC SCH. 40 TEE TO SECOND EMITTER MULCH PER PLANS THREADED PVC ADAPTER, SIZE AS REQUIRED. 2" 12 " FOR LAYOUT INFORMATION, SEE DETAIL: DRIP EMITTER SCALE: NTS PVC TEE, SIZE AS REQUIRED. FLEXIBLE PVC LATERAL LINE 4 NTSSCALE: NOTES: 1.LAYOUT SHOWN IS TYPICAL. ON SITE MODIFICATIONS WILL BE REQUIRED DUE TO VARYING SIZE OF PLANTER ISLANDS. CONSULT WITH LANDSCAPE ARCHITECT ON-SITE PRIOR TO INSTALLATION TO DETERMINE HOW MUCH DRIP NEEDS TO BE INSTALLED AND WHAT CONFIGURATION IS APPROPRIATE. 2.INSTALL NETAFIM DRIP TUBING UNDER WEED BARRIER FABRIC. USE THIS DETAIL FOR ALL TREES PLANTED IN COBBLE ROCK AREAS. CONTRACTOR SHALL BE CAREFUL NOT TO DAMAGE OR PINCH TUBING WHEN PLACING COBBLE ROCK AND BOULDERS. 3.TREES PLANTED IN LAWN AREAS WILL NOT BE WATERED BY DRIP BUT WILL BE WATERED BY THE LAWN SPRINKLERS. 4.THIS DETAIL IS FOR DESIGN INTENT ONLY AND IS NOT TO SCALE. CONTRACTOR MUST INSTALL DRIP LINE PER THIS DETAIL OUT TO THE DRIPLINE OF THE TREES MATURE SIZE. 5.FOR LINEAR PLANTERS WITH TREES, INSTALL NETAFIM IN STRAIGHT LINES RATHER THAN A CIRCULAR PATTERN AROUND THE TREE. 6.INSTALL A FLUSH VALVE (NOT SHOWN) AT THE END OF ALL DRIP LINES, PER PLAN. TWO PC-05 DRIP EMITTER AT SURFACE, ATTACH DIRECTLY TO NETAFIM DRIPLINE . MATURE CANOPY OF DECIDUOUS OR EVERGREEN TREE. TRUNK OF TREE. NETAFIM TLCV26-1801 DRIP LINE TUBING WITH FITTINGS. START 12" OUT FROM TRUNK OF TREE THEN SPIRAL OUT FROM TRUNK TO TREES CANOPY ESTIMATED MATURE DIAMETER. ADJUST NETAFIM IN AND AROUND SHRUBS. SCH. 40 PVC LATERAL LINE PER PLAN. SIDEWALK OR OTHER HARDSCAPE MATERIAL (IF ANY), TYP. TREE DRIP WITH PARTIALPLANTING UNDER CANOPY7 RAINBIRD 44LRC QUICK COUPLER VALVE NOTES: 1.FLUSH ALL PIPING PRIOR TO INSTALLING VALVE. 2.WRAP ALL THREADS WITH TEFLON TAPE. 1.1/2 TO 2 WRAPS MAXIMUM. 3.COMPACT SOILS AROUND VALVE BOX TO 80% OF ORIGINAL DRY DENSITY. 4.INSTALL GEOFABRIC UNDER VALVE BOXES AND TAPE TO PIPE NIPPLES AND VALVE BOX. 5.BOX COLOR - GREEN IN TURF AND TAN IN PLANTER AREAS. 6.IRRIGATION SYSTEM TO BE BLOWN OUT WITH AIR COMPRESSOR THROUGH THE RPZ AND QUICK COUPLERS BEFORE FREEZING TEMPERATURES OCCUR, TYP. 7.SCH 80 PVC TEE OR ELL'S CAN BE USED ON ALL QUICK COUPLERS EXCEPT AT POINT OF CONNECTION (IF QUICK COUPLER(S) ARE INSTALLED AT THE POINT OF CONNECTION). ALL QUICK COUPLER FITTINGS AND NIPPLES AT P.O.C. QUICK COUPLER(S) TO BE GALVANIZED. VALVE BOX (SIZE AS REQUIRED) WITH EXTENSIONS IF NECESSARY INSTALL TOP OF VALVE BOX 1/2" ABOVE FINISH GRADE IN LAWN AREAS AND FLUSH WITH TOP OF MULCH IN PLANTERS. HEAVY DUTY GALVANIZED FASTENERS (2 REQUIRED) SCH. 80 NIPPLES 3/4" MIN GRAVEL BASE SCH. 80 STREET ELL MANIFOLD SCH. 80 TEE. SCH. 80 ELL AND STREET ELL 30" X 1" GALVANIZED ANGLE IRON STAKE QUICK COUPLER VALVE SCALE: NTS BRICK (1 OF 3). NOT REQUIRED IF RAINBIRD VALVE BOX IS USED. 8 NOTES: 1.INSTALL ROTORS 2"-3" AWAY FROM HARDSCAPE PAVING AND 12" AWAY FROM WALLS, BUILDINGS, FENCES OR OTHER STRUCTURES. 2.ALL ROTORS TO HAVE STAINLESS STEEL RISERS. 3.FOR ROTORS WITH FLOWS LESS THAN 8 GPM, STREET ELLS, TEES AND NIPPLES MAY BE 34" IN SIZE.4.LATERAL LINES SHALL BE KEPT MIN. 12" FROM ALL SIDEWALKS AND CURBS. SIDE VIEW TOP VIEW WITH STAINLESS STEEL RISERS. PVC LATERAL LINE (3) 1" MARLEX STREET ELLS ROTOR POP-UP SPRINKLER FINISH GRADE (3) 1" SCH 40 STREET ELLS COMPACTED SOIL 1" PVC SCHEDULE 80 NIPPLE 12" LONG MIN. NOT TO EXCEED 45 DEG. ANGLE. ROTOR HEAD SCALE: NTS10 1804 PRS PER LEGEND. LATERAL LINE WITH PVC TEE OR ELL. PVC STREET ELL OR MALE BARBED ELBOW. PVC FLEX HOSE OR SWING PIPE. PVC STREET ELL OR MALE BARBED ELBOW. FINISH GRADE. SET HEAD FLUSH WITH FINISH GRADE. LAWN POP-UP SPRAY HEAD EDGE OF PAVING . NOTE: 1.USE VAN OR HE VAN NOZZLES AS NEEDED TO KEEP WATER OFF SIDEWALK AND BUILDING. 2.LATERAL LINES SHALL BE KEPT MIN. 12" FROM ALL SIDEWALKS AND CURBS. 3.INSTALL SAM FEATURE FOR SLOPED LAWN AREAS WHERE LOW HEAD DRAINAGE MAY OCCUR. 2-3" MIN. 12" POP-UP SPRAY SCALE: NTS11 WATER SOURCE FROM WELL AND 2" LINE TO STOP AND WASTE VALVE. FIELD VERIFY EXACT LOCATION. 2" PVC MAINLINE TO VALVES 1 1/2" STOP AND WASTE VALVE. CONTRACTOR TO ENSURE WATER DRAINS PROPERLY TO PREVENT FREEZING. WELL 2" POINT OF CONNECTION SCALE: NTS NOTE: 1. ADD BACKFLOW PREVENTION DEVICE IS REQUIRED BY LOCAL ORDINANCES. 2. INSTALL OPTIONAL GATE VALVE AFTER (STOP AND WASTE VALVE) IF DIRECTED BY OWNER. THIS WILL MAKE MAINTENANCE AND WINTERIZATION EASIER AND BETTER. 1" RAINBIRD 44LRC QUICK COUPLER OPTIONAL 1 12" FLOW METER (WEATHERTRACK OR NETAFIM)- OWNER TBD IF FLOW METER TO BE INSTALLED GATE VALVE MANUAL DRAIN S&W FM MD GV QC 9 NOTES: 1.LAYOUT SHOWN IS TYPICAL. ON SITE MODIFICATIONS WILL BE REQUIRED DUE TO VARYING SIZE OF PLANTER ISLANDS. CONSULT WITH LANDSCAPE ARCHITECT ON-SITE PRIOR TO INSTALLATION TO DETERMINE HOW MUCH DRIP NEEDS TO BE INSTALLED AND WHAT CONFIGURATION IS APPROPRIATE. 2.INSTALL NETAFIM DRIP TUBING UNDER WEED BARRIER FABRIC. USE THIS DETAIL FOR ALL TREES PLANTED IN COBBLE ROCK AREAS. CONTRACTOR SHALL BE CAREFUL NOT TO DAMAGE OR PINCH TUBING WHEN PLACING COBBLE ROCK AND BOULDERS. 3.TREES PLANTED IN LAWN AREAS WILL NOT BE WATERED BY DRIP BUT WILL BE WATERED BY THE LAWN SPRINKLERS. 4.THIS DETAIL IS FOR DESIGN INTENT ONLY AND IS NOT TO SCALE. CONTRACTOR MUST INSTALL DRIP LINE PER THIS DETAIL OUT TO THE DRIPLINE OF THE TREES MATURE SIZE. 5.FOR LINEAR PLANTERS WITH TREES, INSTALL NETAFIM IN STRAIGHT LINES RATHER THAN A CIRCULAR PATTERN AROUND THE TREE. 6.INSTALL A FLUSH VALVE (NOT SHOWN) AT THE END OF ALL DRIP LINES, PER PLAN. TWO GPH INC. GPSTCV4M DRIP EMITTER AT SURFACE. SEE DETAIL: 3 MATURE CANOPY OF DECIDUOUS OR EVERGREEN TREE. TRUNK OF TREE. SCH. 40 PVC OR FLEXIBLE PVC LATERAL LINE PER PLAN. SIDEWALK OR OTHER HARDSCAPE MATERIAL(IF ANY), TYP. SHRUBS. TREE DRIP WITH FULL PLANTING UNDER CANOPY 1" = 1'-0"6