Loading...
HomeMy WebLinkAboutLS2.2_Irrigation Plan_4-14-2020gar 2 A1 - g a r ( a ) gar 1 gar 2 A1 - g a r ( a ) gar 1 B1- g a r - f s r r gar 3 gar 2 gar 1 B1- g a r ga r 3 gar 2 ga r 1 FSRR B2-1gar(a) B2-gar(a)B1-1(a) B1-1(a) A2-gar(a)A2-gar(a) A2-1gar(a)A2-1gar(a)ANSI B2-gar(a) HC GARAGE 2DIRECT ACCESSGARAGE 3 GARAGE 1DIRECT ACCESS GARAGE 2DIRECT ACCESS GARAGE 1DIRECT ACCESS GARAGE 1DIRECT ACCESS GARAGE 2DIRECT ACCESS GARAGE 1DIRECT ACCESS GARAGE 2DIRECT ACCESS GARAGE 3ASSIGNABLE B2-1gar(a) DIRECT ACCESS FD C B2-gargar3 gar2 gar1 B2-1gar(a) W/D gar2A2-gargar1 g a r 2 A 2 - g a r g a r 1 W/D A2-1gar(a) W/D A 2 - 1 g a r ( a ) B 1 - 1 ( a ) B 1 - 1 ( a ) B 2 - 1 g a r ( a ) A N S I B 2 - g a r H C B2- g a r gar 3 gar 2 ga r 1 B2- 1 g a r ( a ) W/D gar 2 A2- g a r ga r 1 gar 2 A2 - g a r gar 1 W/D A2 - 1 g a r ( a ) W/D A2- 1 g a r ( a ) B1 - 1 ( a ) B1 - 1 ( a ) B1- 1 ( a ) B1- 1 ( a ) B2 - 1 g a r ( a ) W/D B2- g a r gar 3 gar 2 gar 1 ga r 2 A1- g a r ( a ) gar 1 A1 - 1 g a r ( a ) gar 2 A1- g a r ( a ) ga r 1 A1 - 1 g a r ( a ) 2 6 " D I A . B1- 1 g a r ( a ) 5'-0 " X 3 ' - 0 " SHOWER B1- g a r - f s r r gar 3 gar 2 gar 1 26"DIA . B1 - 1 g a r ( a ) 5'-0"X3'-0" SHOWER B1- g a r gar3 gar 2 gar1 ga r 2 A1- g a r ( a ) ga r 1 A1- 1 g a r ( a ) ga r 2 A1- g a r ( a ) gar 1 A1- 1 g a r ( a ) 2 6 " D I A . B1- 1 g a r ( a ) 5'-0"X3'-0"SHOWER B1- g a r - f s r r ga r 3 ga r 2 ga r 1 26"DIA . B1- 1 g a r ( a ) 5'-0"X3'-0"SHOWER B1 - g a r gar 3 gar 2 gar 1 PARKING SPACES BLDG 15 TYPE C 2-STORY 10 GARAGE PARKING SPACES BLDG 14 TYPE C 2-STORY 10 GARAGE PARKING SPACES BLDG 12 TYPE B 2-STORY 10 GARAGE PARKING SPACES BLDG 13 TYPE B-HC 2-STORY 10 GARAGE PARKING SPACES 3 4" 1" 3 4" 34" 1" 34"1" 34" 1"114" 1" 34" 1" 34" 114" 34"112" 114"1" 112" 1"1"114" 114" 112"34" 112"114"114"1"1"34"34"112" 34"3 4"114"1" 1" 34"34" 34" OWNER TO VERIFY EXACT LOCATION OF CONTROLLER MAINLINE, LATERAL PIPE,VALVES, ETC. SHOWN IN SIDEWALK FOR DRAWING CLARITY ONLY. LOCATE IN LANDSCAPE. TYP. LIMIT LINESHEET LS2.2 SH E E T L S 2 . 1 SH E E T L S 2 . 2 1" 34" 2" 34" 112"1"114"1"34" 34" 114"34"1"3 4" 114"34" 3 4" 34" 1" 3 4" 1" 114" 1" 3 4" 34" 112"34" IRRIGATION NOTES 1.ALL WORK SHALL BE IN ACCORDANCE WITH APPLICABLE CITY AND/OR COUNTY CODES. THE CONTRACTOR SHALL APPLY AND PAY FOR ALL NECESSARY PERMITS. 2.CONTRACTOR SHALL HAVE ALL UTILITIES BLUE STAKED BEFORE DIGGING. ANY DAMAGE TO THE UTILITIES SHALL BE REPAIRED AT THE EXPENSE OF CONTRACTOR WITH NO EXTRA COST TO THE OWNER. 3.PROVIDE AN AS-BUILT, REPRODUCIBLE DRAWING TO OWNER SHOWING ALL DRAINS, HEADS, VALVES, AND PIPES. PROVIDE INSTRUCTIONS TO MAINTENANCE PERSONNEL FOR WINTERIZATION. SPRINKLER SYSTEM TO BE BLOWN OUT WITH AN AIR COMPRESSOR EACH FALL. 4.CONTRACTOR SHALL ONLY USE COMMERCIAL GRADE PRODUCTS AND IS RESPONSIBLE FOR ENSURING ACCURATE COUNTS AND QUANTITIES OF ALL IRRIGATION MATERIALS FOR BIDDING AND INSTALLATION PURPOSES. 5.CONTRACTOR SHALL BUILD IRRIGATION SYSTEM WITH HEAD TO HEAD COVERAGE FOR ALL LAWN AREAS. VAN AND/OR U-SERIES NOZZLES SHALL BE USED WHERE NECESSARY TO PROVIDED HEAD TO HEAD COVERAGE AND/OR TO MINIMIZE OVER SPRAY ONTO STREETS, SIDEWALKS AND/OR BUILDINGS. 6.LANDSCAPE CONTRACTOR (L.C.) SHALL PROVIDE AND INSTALL SLEEVES FOR ALL PIPES AND WIRES UNDER PAVEMENT AND SIDEWALKS. SLEEVES SHALL BE 2 SIZES LARGER THAN PIPE INSIDE. ALL WIRE SHALL BE IN SEPARATE SLEEVES (NOT SHOWN). ALL CONTROL WIRE SHALL BE INSTALLED IN CLASS 200 PIPE. PLACE JUNCTION BOXES WHERE NECESSARY TO MINIMIZE LONG RUNS OR AT DIRECTIONAL CHANGES AS NECESSARY. 7.ALL SLEEVES INSTALLED SHALL BE DUCT TAPED TO PREVENT DIRT OR OTHER DEBRIS ENTERING PIPE. ALL SLEEVES SHALL BE IDENTIFIED BY WOOD OR PVC STAKES AND BE SPRAY PAINTED WITH MARKING PAINT. REMOVE STAKES ONCE IRRIGATION SYSTEM IS COMPLETE. 8.MAIN LINE SHALL BE 2" (UNLESS OTHERWISE DIRECTED). LATERAL LINES SHALL BE NO SMALLER THAN 3/4" UNLESS NOTED ON PLAN. PIPES SHALL CARRY NO MORE THAN THE FOLLOWING: 3/4" PIPE MAX. 8GPM, 1" PIPE MAX. 13GPM, 1-1/4" PIPE MAX. 23GPM, 1-1/2" PIPE MAX. 30GPM, 2" PIPE MAX 50GPM. ADJUST LOCATION OF MAINLINE AND LATERAL LINES AS NECESSARY IN ORDER TO AVOID PLACING BOULDERS, TREES AND SHRUBS DIRECTLY OVER MAINLINE AND LATERAL LINES. 9.MAIN LINES SHALL BE 18" DEEP MIN. AND LATERAL LINES 12" DEEP MIN. NO ROCK GREATER THAN 3/4" DIAMETER SHALL BE ALLOWED IN TRENCHES. 10.PLACE PIPES, VALVE BOXES AND ALL OTHER SPRINKLER CONSTRUCTION IN LANDSCAPE AREAS. ALL PIPES SHALL BE ON PROPERTY OF OWNER. MODIFY LOCATION OF VALVE BOXES AS NECESSARY IN ORDER TO AVOID TREES AND SHRUBS PER PLANTING PLAN. DO NOT LOCATE VALVE BOXES IN LAWN AREAS IF POSSIBLE. 11.AT OWNERS REQUEST AND FOR AN ADDITIONAL FEE, LANDSCAPE ARCHITECT SHALL VISUALLY INSPECT ALL TRENCHES PRIOR TO BACKFILLING. CONTRACTOR SHALL GIVE LANDSCAPE ARCHITECT MIN. 72 HR. NOTICE BEFORE INSPECTION IS TO BE MADE. CONTRACTOR SHALL PRESSURE TEST MAINLINE FOR LEAKS PRIOR TO BACKFILLING. 12.ALL SPRINKLERS SHALL BE ADJUSTED ON-SITE AS NECESSARY TO AVOID ANY WATER SPRAYING ONTO STREETS, SIDEWALKS AND/OR BUILDINGS. 13.ACTUAL INSTALLATION OF IRRIGATION SYSTEM MAY VARY SOMEWHAT FROM PLANS. CONTRACTOR IS RESPONSIBLE TO MAKE NECESSARY ADJUSTMENTS TO ENSURE PROPER COVERAGE OF ALL LANDSCAPED AREAS. 14.LANDSCAPE CONTRACTOR SHALL MATCH PRECIPITATION RATES AS MUCH AS POSSIBLE FOR ALL LANDSCAPED AREAS. 15.INSTALL ALL HEADS 2" AWAY FROM ALL WALKS AND WALLS. VALVE BOXES SHALL BE INSTALLED SQUARED TO AND 6" MIN. AWAY FROM WALKS AND WALLS. 16.DRIP LINES SHALL BE FLEXIBLE AR PVC TUBING BY GPH. FOR DRIP AREAS REQUIRING 0-4 GPM USE 1/2" TUBING. FOR DRIP AREAS REQUIRING 4-8GPM USE 3/4" TUBING AND FOR DRIP AREAS REQUIRING 8-13 GPM USE 1" TUBING. CONTRACTOR TO VERIFY PLANT QUANTITIES ON EACH DRIP LINE AND SIZE PIPE ACCORDINGLY. 17.CONTRACTOR TO INSTALL NETAFIM IN-LINE DRIP FOR TREES IN PLANTER AREAS PER DETAILS. MODIFY DRIP ZONES AS NECESSARY TO PROVIDE ADEQUATE COVERAGE TO ALL LANDSCAPED AREAS. 18.POWER TO CONTROLLER TO BE PROVIDED BY ELECTRICAL CONTRACTOR. OWNER TO SPECIFY EXACT LOCATION OF CONTROLLER. IF MOUNTED OUTSIDE, CONTROLLER TO BE MOUNTED IN WEATHERPROOF LOCKING WALL MOUNTED CABINET PER MANUFACTURERS INSTRUCTIONS. LANDSCAPE CONTRACTOR SHALL ENSURE THE CONTROLLER IS GROUNDED PER LOCAL CODE AND PER MANUFACTURER SPEC. 19.IF THE STATIC PRESSURE AT THE POINT OF CONNECTION EXCEEDS 110 PSI, INSTALL A BRASS PRESSURE REDUCER IN-LINE WITH THE RPZ PER MANUFACTURER SPECS. INSTALL THE RPZ AND PRESSURE REDUCER IN A LOCKING METAL CABINET. ADJUST PRESSURE AS REQUIRED FOR NORMAL OPERATION OF THE IRRIGATION SYSTEM. 20.INSTALL THE PRS-D OPTION FOR SPRAY VALVES IF THE STATIC PRESSURE AT SPRAY HEADS EXCEEDS 70 PSI. 21.THE IRRIGATION SYSTEM SHALL BE CONNECTED TO A WELL ON-SITE. THE MAX. FLOW RATE FOR THE WELL SHALL BE 35 GPM. THE WELL PUMP SHALL BE CAPABLE OF PUMPING 35 GPM AT 75 PSI. IF A BACKFLOW PREVENTOR IS REQUIRED BY BOZEMAN CITY, THEN THE PRESSURE COMING OUT OF THE WELL HEAD WILL NEED TO BE AT LEAST 87 PSI. THE CONTRACTOR SHALL CONFIRM WITH BOZEMAN CITY IF A BACKFLOW PREVENTOR IS REQUIRED OR NOT. CONTRACT NEEDS TO SIZE THE NEW PUMP INSIDE THE WELL TO PROVIDE THE NECESSARY FLOW AND PRESSURE. PERENNIALS/GRASSES 1 GPSTCV2M (2GPH) ALL SHRUBS 2 GPSTCV2M (2GPH) TREES IN PLANTERS 2 PC-05 (5GPH) NOTE: 1.EMITTERS LISTED ARE AVAILABLE FROM GPH AND RAINBIRD. 2.EMITTERS ARE NOT NECESSARY FOR TREES IN LAWN AREAS. 3.INSTALL NETAFIM TLCV IN ADDITION TO PC-05 EMITTERS PER DETAILS ON SHEET LS4.1 & LS4.2. 4.INSTALL PC-DIFFUSER CAP ON ALL PC-05 EMITTERS. PLANT TYPE EMITTER QTY EMITTER TYPE DRIP EMITTER LEGEND VALVE ID TAG ZONEVALVE PRESSUREGPM SIZE NOT SHOWN DRIPLINE: NETAFIM TLCV26-18 .26/18"F --30 ------------SEE IRRIGATION DETAILS3-7 SYMBOL MANUFACTURER-MODEL NUMBER PAT. RD. PSI GPM Q T H TT TQ F DETAILS REMARKSDRIP GPH IRRIGATION LEGEND ------------2.030F JUMBO VALVE BOXDRIP CONTROL ZONE KIT: RAINBIRD XCZ-100-PRB COM OR XCZ-150-PRB COM NOT SHOWN LATERAL LINE: PVC SCH. 40 (SIZE PER PLAN) JUMBO VALVE BOX 'A' RAIN BIRD PESB-PRS-D AUTOMATIC CONTROL VALVE (SIZE AS NOTED ON PLAN). INSTALL PRS-D OPTION PER IF -- SLEEVE (SIZE TO BE A MIN. OF TWICE THE DIAMETER OF THE MAIN, LATERAL) 1" RAINBIRD QUICK COUPLER VALVE, MODEL #44LRC. FOR IRRIGATION SYSTEM BLOWOUT. ALL GALVANIZED FITTINGS & PIPE. COORDINATE WITH ALL TRADES 1.00 1.38 1.98 ----3.82 --25'45 RAIN BIRD 5004-PL-R-SS WITH 30 SERIES NOZZLES 1.40 1.85 2.96 ----5.78 --30'45 Q,T,H,F Q,T,H,F -- 1.92 2.46 3.81 ----7.58 --35'45 Q,T,H,F ADJUST ARC AS NEEDED ADJUST ARC AS NEEDED RAINBIRD CONTROLLER, MODEL #ESPLXBASIC. CONTRACTOR TO COORDINATE WITH TRADES TO RUN CONDUIT AND SLEEVING FOR WIRING TO VALVES. SIZE CONTROLLER AS NECESSARY. PLACE CONTROLLER IN WEATHER RESISTANT CABINET WIRE CHASE, SIZE TO BE TWICE THE DIAMETER OF THE WIRE BUNDLE WITHIN, 1" DIA. WC IS THE MINIMUM SIZED ALLOWED.COORDINATE WITH ALL TRADES RAIN BIRD 5004-PL-R-SS WITH 25 SERIES NOZZLES NOT SHOWN RAIN BIRD 5004-PL-R-SS WITH 35 SERIES NOZZLES ADJUST ARC AS NEEDED ADJUST ARC AS NEEDED RAIN BIRD 1804-PRS POP-UP SPRAY 8 SERIES H,F,VAN .528'--30 --1.04 GPH INC. GPSCV2M DRIP EMITTER ADJUST ARC AS NEEDED--11 10 1 12, 13 & 17 214-16 8 16 SEE IRRIGATION DETAILS --ADJUST ARC AS NEEDED 3-7 11 11 10 10 COORDINATE EXACT LOCATION WITH OWNER. FLUSH VALVE: 1/2" PVC BALL VALVE. INSTALL AT END OF ALL DRIP LINES IN 10" ROUND VALVE BOX REFERENCE DETAILS3 ---- --VAN ---- DRIP LATERAL: PVC SCH 40, OR STICKY-STRIP PVC HOSE BY GPH. CONTRACTOR SHALL SIZE PIPE PER DETAILS AND SPECS. 2" SCH. 40 MAINLINE ------------5.030FNOT SHOWN --RAINBIRD PC-05 EMITTER WITH DIFFUSER CAP SEE IRRIGATION DETAILS3-7 SEE IRRIGATION DETAILS 14-16 SEE IRRIGATION DETAILS SEE IRRIGATION DETAILS3-7,19 SEE IRRIGATION DETAILS RAIN BIRD 1804-PRS POP-UP SPRAY STRIP SERIES LCS, RCS, SST 15'30 ----.61 ----1.21 --ADJUST ARC AS NEEDED11 RAIN BIRD 1804-PRS POP-UP SPRAY 10 SERIES Q,T,H,F,VAN .7910'.3930 .53 1.58 ADJUST ARC AS NEEDED--11 ---- ---- ----RAIN BIRD 1804-PRS POP-UP SPRAY 12 SERIES Q,T,H,F,VAN 1.3012'.6530 .87 2.60 ADJUST ARC AS NEEDED--11---- RAIN BIRD 1804-PRS POP-UP SPRAY 15 SERIES Q,T,H,F,VAN 1.8515'.9230 1.23 3.70 RAIN BIRD 1804-PRS POP-UP SPRAY 18 SERIES VAN 18'----30 -- NOT SHOWN 14 GAUGE SINGLE STRAND SOLID COPPER CONTROL WIRE 2, 15,& 17 15 REQ. PER SPECS/DETAILS. VAN --------------39'45 ADJUST ARC AS NEEDEDRAIN BIRD 5004-PL-PC,FC 10 WELL LOCATION AND POINT OF CONNECTION REFERENCE DETAILS9 TH I S D R A W I N G I S T H E I N T E L L E C T U A L P R O P E R T Y O F I N - S I T E D E S I G N G R O U P . D O N O T C O P Y O R R E P R O D U C E I N A N Y W A Y W I T H O U T T H E E X P R E S S W R I T T E N P E R M I S S I O N O F I N - S I T E D E S I G N G R O U P . C O P Y R I G H T © 2 0 0 6 ar c h i t e c t s @ i n - s i t e d e s i g n g r o u p . c o m 17 N o r t h 4 7 0 W e s t A m e r i c a n F o r k , U t a h 8 4 0 0 3 80 1 . 7 5 6 . 5 0 4 3 w w w . i n - s i t e d e s i g n g r o u p . c o m 4- 1 4 - 2 0 2 0 T Co r y B . Wh i t i n g # 1 0 6 2 9 CETIHCRA EPACSDN A L D E S N E C I L CI T Y S U B M I T T A L 45 5 5 F A L L O N S T . B O Z E M A N , M T 5 9 7 1 5 PH A S E B IC O N A T F E R G U S O N F A R M PL A N IR R I G A T I O N LS2.2 19-143 4-14-2020 1-21-2020 CBW JES SCALE: 0 1"=30'-0" ON 24X36 SHEET 30'30'60'90' 1 1 1