Loading...
HomeMy WebLinkAboutE001 Site Photometric Lighting Plan 03-05-2019DE S I G N D E V E L O P M E N T B L O C K 6 B U I L D I N G JE S S I C A J E L L I S O N D E S I G N G R O U P I N C . 11 E C U R T I S S S T , B O Z E M A N , M T 5 9 7 1 5 je s s i c a @ j e s s i c a j e l l i s o n d e s i g n g r o u p . c o m CO P Y R I G H T © 20 1 9 40 6 . 5 9 9 . 8 1 6 3 Je s s i c a J . J e l l i s o n AR C H I T E C T 2 0 3 N 2 0 T H A V E . - B L O C K 6 , W E S T P A R K M A N O R , F I R S T A D D I T I O N , B O Z E M A N , M T South Entry Canopy Readings at 0 FT AFG Illuminance (Fc) Average = 5.80 Maximum = 10.6 Minimum = 0.0 Avg/Min Ratio = N.A. Max/Min Ratio = N.A. South Entry Canopy Readings at 0 FT AFG Illuminance (Fc) Average = 5.80 Maximum = 10.6 Minimum = 0.0 Avg/Min Ratio = N.A. Max/Min Ratio = N.A. Readings at 0 FT AFG Illuminance (Fc) Average = 4.84 Maximum = 10.6 Minimum = 0.0 North Entry Canopy Avg/Min Ratio = N.A. Max/Min Ratio = N.A. Readings at 0 FT AFG Illuminance (Fc) Average = 4.84 Maximum = 10.6 Minimum = 0.0 North Entry Canopy Avg/Min Ratio = N.A. Max/Min Ratio = N.A. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.5 0.8 1.1 0.6 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.4 0.8 1.7 3.7 7.4 2.6 0.5 0.2 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.4 0.7 1.4 2.9 7.4 7.5 10.6 6.4 1.0 0.2 0.1 0.0 0.0 0.0 0.1 0.1 0.2 0.5 1.1 2.6 5.1 9.0 5.8 5.9 0.0 0.2 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.6 2.0 3.9 9.1 6.2 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 1.2 6.3 7.8 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.4 1.8 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.5 2.6 9.2 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 1.2 4.5 7.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.6 2.8 7.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.4 1.0 4.3 9.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.6 2.1 5.8 0.0 0.0 0.1 0.1 0.1 0.0 0.0 0.1 0.2 0.3 0.9 4.1 9.1 0.7 0.5 0.2 0.1 0.0 0.0 0.1 0.1 0.2 0.5 1.5 5.4 5.4 2.2 0.6 0.2 0.1 0.0 0.0 0.1 0.1 0.3 0.8 3.4 6.5 4.5 10.6 8.1 1.7 0.3 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.6 1.8 6.4 8.5 7.3 6.6 1.5 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.5 3.3 10.6 7.0 8.3 2.2 0.6 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.4 1.9 4.9 1.5 2.1 0.7 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.4 0.6 0.1 0.3 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.5 1.9 1.0 0.5 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.5 1.3 3.5 6.8 7.6 5.0 1.9 0.7 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.6 1.5 4.1 10.3 11.0 4.7 1.8 0.7 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.4 1.0 2.3 4.4 4.6 2.8 1.2 0.5 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.5 1.0 1.6 1.7 1.2 0.6 0.3 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.3 0.4 0.6 0.7 0.6 0.3 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.3 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 BB A A A A A A A A A A A A A A A A FIXTURE SCHEDULE SYMBOL LUM. LUMENS DESCRIPTION LUM. WATTS TOTAL WATTS BUG RATING A B 1711 4" ROUND DOWNLIGHT 20W 4000K 20.4 326.4 B1-U0-G0 3468 WALLPACK 26W 4000K FULL CUT-OFF 29.8 59.6 B1-U0-G1 The light loss factor (LLF) is a product of many variables, only lamp lumen depreciation (LLD) has been applied to the calculated results unless otherwise noted. The LLD is the result (quotient) of mean lumens / initial lumens per lamp manufacturers' specifications. Illumination values shown (in footcandles) are the predicted results for planes of calculation either horizontal, vertical or inclined as designated in the calculation summary. Meter orientation is normal to the plane of calculation. The calculated results of this lighting simulation represent an anticipated prediction of system performance. Actual measured results may vary from the anticipated performance and are subject to means and methods which are beyond the control of RAB Lighting Inc. Mounting height determination is job site specific, our lighting simulations assume a mounting height (insertion point of the luminaire symbol) to be taken at the top of the symbol for ceiling mounted luminaires and at the bottom of the symbol for all other luminaire mounting configurations. It is the Owner's responsibility to confirm the suitability of the existing or proposed poles and bases to support the proposed fixtures, based on the weight and EPA of the proposed fixtures and the owner's site soil conditions and wind zone. It is recommended that a professional engineer licensed to practice in the state the site is located be engaged to assist in this determination. The landscape material shown hereon is conceptual, and is not intended to be an accurate representation of any particular plant, shrub, bush, or tree, as these materials are living objects, and subject to constant change. The conceptual objects shown are for illustrative purposes only. The actual illumination values measured in the field will vary. Photometric model elements such as buildings, rooms, plants, furnishings or any architectural details which impact the dispersion of light must be detailed by the customer documents for inclusion in the RAB lighting design model. RAB is not responsible for any inaccuracies caused by incomplete information on the part of the customer, and reserves the right to use best judgement when translating customer requests into photometric studies. RAB Lighting Inc. luminaire and product designs are protected under U.S. and International intellectual property laws. Patents issued or pending apply. NOTES: E 001 PHOTOMETRIC LIGHTING PLAN NPHOTOMETRIC LIGHTING SITE PLAN1