Loading...
HomeMy WebLinkAbout7.0 A203 Roof Plan 2019.06.141 A301 2 A300 2 A301 2 A401 1 A401 1 A400 4 A450 3/4" / 12" DRIVE -UP CANOPY BELOW ENTRY CANOPY BELOW ELEVATOR OVERRUN 2 10 D D LL K K A B C 6 8 7 12 M N 11 G JJ 1 A402 2 A402 3 A402 4 A402 66 ' - 0 " RI D G E RI D G E 2 A400 1/4" / 12" 4 A600 9 A451 1 9 543 H E E F F II1A702 2 A7 0 2 3 A7 02 4 A702 1/4"/12" 1/4"/12" 1/ 4 " / 1 2 " 1/ 4 " / 1 2 " 1/ 4 " / 1 2 " 1/4"/12" 1/4"/12" 1/ 4 " / 1 2 " 1/4"/12" 1/ 4 " / 1 2 " 1/4"/12" 1/ 4 " / 1 2 " 1/ 4 " / 1 2 " 1/4"/12" 1/ 4 " / 1 2 " 1/ 4 " / 1 2 " 1/4"/12" 1/ 4 " / 1 2 " 1/4"/12" 3/8" / 12" A550 1 A550 2 AREAS BASEMENT 5106 S.F. FIRST FLOOR 5307 S.F. SECOND FLOOR 4523 S.F. TOTAL 14,936 S.F. SUBSTRATE FIRESTONE INSULATION 1/2" MIN. (SEE NOTE #2) SUBSTRATE INSULATION 1/2" (13 mm) MIN. SEE NOTES (SEE NOTES) TPO MEMBRANE WATER DAM COMPRESSION RING STRAINER BASKET COMPRESSION RING STRAINER BASKET 12" SEE SLOPE LIMITS OVERFLOW ROOF DRAIN PRIMARY ROOF DRAIN CONTINUOUS BEAD OF FIRESTONE WATERBLOCK (SEE NOTE 4) APPROPRIATE FIRESTONE BONDING ADHESIVE (ADHERED SYSTEMS ONLY) 2'-0" MIN. NOTES: 1. REFER TO FIRESTONE WEBSITE FOR THE MOST CURRENT INFORMATION. 2. HOLE IN MEMBRANE SHOULD EXTEND A MINIMUM OF 1/2"(13mm) BEYOND CLAMPING RING AND SHOULD NOT BE SMALLER THAN THE DIAMETER OF THE LEADER PIPE. 3. INSULATION ADJACENT TO DRAIN TO BE APPROPRIATE FIRESTONE INSULATION WITH APPROPRIATE BONDING SURFACE. 4. FIRESTONE WATERBLOCK MIN. OF 1/2 OF 10 OZ (295ML) TUBE PER 4" DRAIN. USE ADDI9TIONAL WATERBLOCK FOR LARGER DRAINS. 5. IN REROOF APPLICATIONS: • REMOVE EXISTING FLASHING DOWN TO METAL BOWL. • REPAIR OR REPLACE BROKEN DRAIN COMPONENTS. • DRILL AND TAB BROKEN DRAIN BOLTS AND REPLACE IF NECESSARY. SUMP AREA FIELD SEAM REQUIREMENTS: A. IF SEAM EDGE IS WITHIN 9" (229MM) OF DRAIN COMPRESSION RING, EPDM TARGET PATCH REQUIRED. B. IF FIELD SEAM EDGE IS WITHIN 9" (229mm) TO 18" (457mm) OF DRAIN COMPRESSION RING, INSTALL A LAYER OF 5" QUICKSEAM FLASHING CENTERED OVER SEAM EDGE. 5" QUICKSEAM FLASHING SHALL EXTEND 3" (76mm) MIN. BEYOND EDGE OF SUMP. MEMBRAND SLOPE LIMITS: A. MAXIMUM SLOPE FOR MAX MEMBRANE SHALL BE 2" (51mm) - 12" (305mm) REFER TO DETAIL D-4 WHEN SLOPE EXCEEDS LIMITATIONS. B. MAXIMUM SLOPE FOR STANDARD MEMBRANE SHALL BE 6" (162mm) - 12" (305mm). STATUS: JOB NO.: CHECKED: DRAWN: Copyright © 2019 71 9 W . M E N D E N H A L L S T . BO Z E M A N M O N T A N A 5 9 7 1 5 PH O N E : 4 0 6 - 5 5 6 - 8 0 8 0 FA X : 4 0 6 - 5 8 5 - 1 6 7 7 JE S S E @ J D S A R C H I T E C T S B O Z E M A N . C O M JD S A R C H I T E C T S B O Z E M A N . C O M 19 4 1 W E S T M A I N , B O Z E M A N , M O N T A N A 6/14/2019 Author Checker 17-020 A203 ROOF PLAN 1/8" = 1'-0" A203 1 ROOF PLAN N 6" = 1'-0" A203 2 ROOF DRAIN R E V I S I O N S C H E D U L E N O : D E S C R I P T I O N : D A T E : B Y :