Loading...
HomeMy WebLinkAboutC-1-Civil-Sitelayout-021519 PROPOSED APPROACH PROPOSED BOZEMAN WEST APARTMENTS PROPOSED APPROACH ZONED R-4 EXPOSE AND CAP 6" SERVICE STUB AT TEE. EXISTING HYDRANT CONNECT TO EXISTING WATER MAIN 40'+ CONNECT SEWER TO 40'+--� EXISTING MANHOLE APPROXIMA ST TCUT APPROXIMATE STREET CUT /e eW 1 aW ¢W 1 S REET PA ING,TYP I TSCHACHE LANE 60'EASEMENTi - - - eW SECTION noMar�_ R O ESREPLACE 3020 SF OF VISION TR LE --------- --------------- I I SECTIONS OF EXISTING � EXS IDAMA 8"SEWER MAIN -- -- I SIDEWALK WATER MAIew REMOVE DAMAGED SID 'OFEWALK _ I I I r------ ____________ EXISTING 6"DAMAGED SIDEWALK 5.0'E PED RIAN 11tAIL EASEMENT E ENT XIST NO t WAL mess- - .E I TIN EXI ING 1'WA �E _MY_ _ I STALL 4"D.I.P.WATER 15'FRONT YARD SETBACK &FIRE SERVICES 4'0• 24 0• — 4"PVC IRR.COND,TYP A <�. T 8" WESRBMAIN STOR 7 ETLAND#1 REMOVE 8 REPLACE 285 SF OF W IN ALL 4" C- POND J.D./ EXISTING DAMAGED 6'SIDEWALK a EWEVE 5/ SITE PLAN NOTES: CP 4700.77' N ' w a P O ED / S RVIC�, -7 18.0' m C RB WALK OPEN SPACE TY 30'WATER SEWER REQUIRED=150 SF/UNIT=8,100 SF P oPdsED 11 3m EASEMEN 9 / ALL SECOND AND THIRD FLOOR UNITS HAVE A 150 SF BALCONY/PORCH 0, m 9 EXISTING PARKING LOT y 2 m BLDG 1 BALCONY THAT ACCOUNTS FOR 50%OF THE REQUIRED FD ITH ORN/ ENC O MEN PROPOSED / OPEN SPACE PER 38.520.060.B.C.(2,700 SF) STROB ON D. 1 CURB WALK 11 n J 18.01 PATIO F) 2420 TSCHACHE THE GROUND LEVEL UNITS HAVE A 150 SF ENCLOSED 2"PVC LIGHT COND,TYP >_m LANE ALSO PRROVIDOVID( I . / ED IS A 3,500 SF SHARED OPEN SPACE WITH ADDITIONAL LANDSCAPING,SIDEWALK AND A CONCRETE PRO ED SLAB WITH A PICNIC TABLE. BLDG 3 - I CU ALK / STRIP .PARKI G EXISTING GRAVEL TRAIL(TO BE 2440 TSCHACHE �1n TALLS AND 1 TOTAL=2,700+2,700+3,500=8900 SF MOVED BY PARKS DEPARTMENT) LANE I / � PARKLAND / US RMAILBOX AS 3 P O BED BAL ONV / PARKLAND FOR 8 UNITS/ACRE WAS PREVIOUSLY I 2 m g.0• > PP Ov Y USPS B.o'1 �° 2 E RQACHMENT ACCOUNTED FOR WITH THE SUBDIVISION/PUD.APPLICANT 5 \ SUBMITTED PROPOSAL TO RPAB FOR CASH IN LIEU FOR ,�B.o < ) ? / ADDITIONAL PARKLAND. y m 10 \ 4 GENERAL NOTES: CONNECT UNITS TO \m 7 P OPO \HVD ROSE PARK TRAIL W/6' 1.ALL OF THE WATER&SEWER INFRASTRUCTURE SIDEWALK \ \ D. INST PAR PVC I AALLLL CON / WILL BE INCLUDED WITH PHASE 1. \ \\ LOT1wIGHT, 9 3 INS LL4"D.I.P. 8 FI E ERVICES 2.THE SUB-BASE FOR THE ENTIRE PARKING LOT WILL \ i• L.E. / ° � BE COMPLETED WITH PHASE 1 TO ASSURE ADEQUATE 35'WETLAND SETBACK m tye TURNAROUND FOR EMERGENCY SERVICES AS WELL / / / (FOLLOWING PERMITTED FILL) AS A SECOND ACCESS POINT. 3.SEE THE APPROVED 404 PERMIT FOR THE EXTENTS 10'SETBACK \ /� q jc ELECTRICAL METERS OF WETLAND FILL. ELECTRICAL ETERS / D'WA RBSEWE WET// 6 EASEMENT J.D.J D / �NSTALL P K I / LEGEND LOT LID Q .o• T / 5'CONC TE DEWALK 35'WATERCOURSE SETBACK PR0I;OSE WATERCOURSE SETBACK-ZONE 2 �yy /� 3 / J BAL ROOACyMENT / UNDERGROUND ELECTRIC 1^ e.o' / // 4,1 sFs ED UNDERGROUND \/ BLDG 2 '� /CO ETE PAD,CORIAN PA A // SH TREES,PEDESTRIAN LIGHT SEWER MAIN s. 7' 2430TSCHACHE3 WERGARDENS,PICNICTABLE / 1 ��j OVERLOOK OF NATURAL OPENSP CE, ,w 8"W ATER MAIN&FIRE SERVICE LINE \\ 1•. , LANE / /// SO TIOONSTESTATION&81KERE IR w WATER SERVICE LINE / I I 10.464 ACRES TO BE CONNECTED TO FUTURE \ / COMMON OPEN SPACE EXISTING CONTOURS(1'INTERVAL) ROSE PARK TRAIL / PUBLIC ACCESS EASEMENT EASEMENT OR SETBACK AS LABELED UNDERGROUND GAS LINE e / UNDERGROUND COMMUNICATION LINE / ORM / POND CENTERLINE DRAINAGE INSTALL 4"D.I.P.WA ER\ / 20'REAR YARD SETBACK &FIRE SERVICE / CONSTRUCTION NOTES: / 1.ALL ISLANDS ARE&WIDE MINIMUM. ROSE PARK 2.PARKING SPACES ARE 9'MIN.WIDTH,H.0 STALLS ARE 8'MIN. 3.DRIVE AISLES ARE 24'MIN.WIDTH. / 4.SEE GEOTECHNICAL REPORT FOR PARKING LOT SECTION DEPTHS. INTERMInENT DRAINAGE 5.CURB RADII ARE TO BE T UNLESS OTHERWISE NOTED. \� (NON JURIS.PER C.D.) 6.ALL INFRASTRUCTURE SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE MONTANA PUBLIC WORKS. / 7.THE CONTRACTOR SHALL CONTACT ONE CALL @ 1-800-424-5555 FOR ONSITE UTILITY LOCATION.ALL UTILITIES SHALL BE MARKED BEFORE DIGGING. UTILITIES SHOWN ARE NOTES: / FOR PLANNING PURPOSES ONLY. 8.THE CONTRACTOR SHALL NOTIFY THE BOZEMAN WATER&SEWER DEPARTMENT A Q INSTALL TRASH ENCLOSURE MINIMUM OF 24 HOURS PRIOR TO BEGINNING ANY WORK. © INSTALL HANDICAP PARKING SIGNS 9.CONSTRUCTED SIDEWALKS SHALL MEET ALL SPECIFICATIONS AND REQUIREMENTS OF (a) INSTALL HANDICAP RAMP ADA CERTIFICATION THE CITY OF BOZEMAN SIDEWALK POLICY. ® INSTALL 5'TEXTURED CROSSWALK / 10.MINIMUM OF 18"SEPARATION BETWEEN SERVICES INSTALLED IN SAME TRENCH. 5) INSTALL INVERTED"U"BIKE RACK THIS CIVIL SITE PLAN HAS BEEN DESIGNED TO MEET ADA 11.SEE CITY OF BOZEMAN APPROVED FIRE LINE PLANS FOR FIRE LINE CONSTRUCTION © FIRE DEPARTMENT CONNECTION W/HORN&STROBE STANDARDS. AND THE CITY OF BOZEMAN APPROVED MAIN EXTENSION PLANS FOR THE (Y) POWER TRANSFORMER GRAPHIC SCALE CONSTRUCTION OF THE WATER&SEWER MAINS. (A) BIKE REPAIR STATION / 30 0 15 30 12.CURB WALK WIDTH DIMENSIONS INCLUDE 6"OF CURB.T CURB WALK TO BE 6.5'WIDE ® DOG WASTE STATION DATE ( IN FEET) SIDEWALK AND ONE CURB AND 9'DOUBLE SIDED CURB WALK IS TO HAVE 8'OF SIDEWALK 1 inch= 30 ft. AND TWO CURBS. 11"X17":1"=60 ft VERIFY SCALE REVISIONS DRAWN BY:JRM PROJECT NUMBER THESE PRINTS MAY BE NO. DESCRIPTION DATE BY TSCHACHE APARTMENTS 1086.011 REDUCED.LINE BELOW CHK'D.BY: MEASURES LINE H 1 ADDITION OF COVERED PARKING 11-20-18 JRM SHEET NUMBER ONEORIGINAL DRAWING. Engineering APPR.ev: BOZEMAN MT 2 UPDATED PER DRC COMMENTS 01-07-19 JRM 204 N.111h Ave. Consulting Bozeman,MT 59715 DATE:10/23/18 DRAWING NUMBER ' I 3 UPDATED PER DRC COMMENTS 8 REMOVAL OF STORM PIPE 02-15-19 JRM NESISDesign phone:(406)581 a319 MODIFY SCALE ACCORDINGLY NGINEERING, INC Planning Q.A.REVIEW LAYOUT&UTILITIES C BY: -1 H:\1086\011\ACAD\SHEETS\C-1.dwg Plotted bychrislopherwasia on 2/14/20194:09PM 7�7 H;ir,nrn,n(,13tu�IJR�aIllo 0leluihltt#t COPYRIGHT©GENESIS ENGINEERING,INC.2019 DATE: