HomeMy WebLinkAbout1919 West Main - Multi-Tenant Building - Fireline1919 WEST MAIN MULTI-TENANT BUILDINGBOZEMAN, MONTANAPLAN & PROFILEFIRE SERVICE LINEFS-2RECORD DRAWING DECEMBER 2015 EXCAVATED MATERIAL 18"4"3'-6" MAXIMUMMIN. 12" MIN. NOTES: 1. ALL EXCAVATION DEPTHS OVER 20 FEET MUST HAVE SLOPING OR BENCHING SYSTEM DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER. 2. WHERE TRENCH PASSES THROUGH EXISTING PAVEMENT, THE PAVEMENT SHALL BE CUT ALONG A NEAT VERTICAL LINE A MINIMUM OF 12" FROM THE EDGE OF THE TRENCH OPENING. WHERE NEAT LINE IS LESS THAN 3 FEET FROM THE EDGE OF EXISTING PAVEMENT OR CURB AND GUTTER SECTION, REMOVE AND REPLACE ENTIRE PAVEMENT SECTION BETWEEN TRENCH AND EDGE OF PAVEMENT. 3. WHEN IN UNSTABLE OR SOFT MATERIAL, TRENCH WALLS SHALL BE BACK SLOPED FROM THE BOTTOM OF THE TRENCH. (TYPE 1 EXCAVATION). * EXISTING STREET SURFACE SUBGRADE OR GROUND SURFACE VERTICAL TRENCH WALLS WITH SHORING TO CONFORM TO O.S.H.A. REGULATIONS. TYPE 2 EXCAVATION. * BACK SLOPE AS SPECIFIED TO CONFORM TO O.S.H.A. REGULATIONS. * TYPE 1 EXCAVATION: (NO STEEPER THAN 1:1 SLOPE EXCEPT FOR ROCKS). TYPE "A" TRENCH BACKFILL TYPE "1" PIPE BEDDING IMPORTED 3/4" MINUS SELECT BEDDING MATERIAL, PLACED IN 6" MAXIMUM LAYERS AND THOROUGHLY COMPACTED. TYPE "2" BEDDING WHERE REQUIRED FOR SOFT OR UNSTABLE FOUNDATION. TRENCH WIDTH=O.D. OF PIPE PLUS 2 FEET MINIMUM TRENCH WIDTH= 3.5 FEET INSTALL DETECTABLE WARNING TAPE 18" MAXIMUM DEPTH. (OPTIONAL)6"* SEE O.S.H.A. SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION. SECTIONS 1926.651 AND 1926.652. NO VERTICAL REQUIREMENT EXISTING SEWER OR WATER 1. NO EXCEPTION TO THE MIN. SEPARATION REQUIREMENT IS PERMITTED WHEN THE SEWAGE CARRYING PIPE IS A FORCE MAIN. AT CROSSINGS, ONE FULL LENGTH OF WATER MAIN PIPE SHALL BE LOCATED SO THAT BOTH JOINTS WILL BE AS FAR FROM THE FORCE MAIN AS POSSIBLE. 2. LESS THAN 18 INCHES OF SEPARATION IS PERMITTED WHEN THE GRAVITY SEWER AT THE CROSSING IS MADE FROM A SINGLE 20 FOOT LENGTH OF AWWA PRESSURE PIPE AND THE CROSSING ANGLE IS APPROXIMATELY 90 DEGREES. SPECIFIC MONTANA DEPARTMENT OF ENVIRONMENTAL QUALITY APPROVAL IS REQUIRED FOR A VERTICAL SEPARATION OF LESS THAN 18 INCHES BETWEEN WATER MAIN AND SANITARY SEWER. 3. "L" IS A STANDARD LENGTH OF PIPE AS SUPPLIED BY A PIPE MANUFACTURER. 4. ADEQUATE STRUCTURAL SUPPORT FOR PIPES AT CROSSINGS SHALL BE PROVIDED. NOTES: 18" MIN.1 2 3L L/2 10'-0" MIN. 18" MIN. 1 2 L 3 L/2 1 EXISTING SEWER OR WATER WATER MAIN OR SERVICE SEWER MAIN OR SERVICE NEW SEWER OR WATER MAIN/SERVICE NEW SEWER OR WATER MAIN/SERVICE 16"6'-3"4'-10"7'-8"5'-9"5'-9"4'-2"4'-5"2'-9" UNDISTURBED EARTH AND 1500 PSF SOIL BEARING PRESSURE. THIS TABLE IS BASED ON 150 PSI MAIN PRESSURE NOTE: 2'-7"3'-7" 2'-6"2'-9" 2'-0"2'-5" 1'-6"2'-0" 1'-0"1'-9" 0'-6"1'-7" 3'-8"5'-0" 3'-6"3'-10" 2'-10"3'-3" 2'-3"2'-8" 1'-8"2'-0" 1'-0"1'-8" 5'-0"6'-9" 4'-10"5'-1" 4'-0"4'-4" 3'-2"3'-6" 2'-4"2'-8" 1'-6"1'-10" 4'-1"5'-8" 4'-0"4'-3" 3'-3"3'-8" 2'-6"3'-0" 1'-11"2'-3" 1'-5"1'-10" BABABABA 14" 12" 10" 8" 6" 3" & 4" SIZES FITTING ƒ%(1' REDUCERS &ƒ%(1' :<(6ƒ%(1'TEES & PLUGS MIN. 3 B A B 1919 WEST MAIN MULTI-TENANT BUILDINGBOZEMAN, MONTANADETAILSFS-3 1 TYPICAL UTILITY TRENCH NTS 2 WATER/SEWER SEPERATION NTS 3 STANDARD FIRE SERVICE LINE INSTALLATION NTS 4 THRUST BLOCK DETAIL NTS RECORD DRAWING DECEMBER 2015