HomeMy WebLinkAboutHouse of Clean Fire Service I I UNDERGROUND LEGEND SYMBOL DESCRIPTION CALL 1-800-424-5555 Z+ OS&YVALVE I BEFORE DIGGING. ----- NEW UNDERGROUND FIRE LINE EXISTING UNDERGROUND FIRE SERVICE ATER MAIN /�// a, TAPPING SLEEVE THRUST BLOCKING CIF CUT IN FIELD REDUCER DON UNLESS OTHERVASE NOTED \� \ B TOE THREAD ONE END TBE THREAD BOTH ENDS GOE GROOVE ONE END T&G THREAD&GROOVE OS&Y OUTSIDE STEM&YOKE WT WITH ON DOWN FG FINAL GRADE i\ AFF ABOVE FINISHED FLOOR I G r; TEE TEE(PLUGGED) BEND I I _ I I AREAS(SQFT)FOR THRUST BLOCKING I TEES&PLUGS 90'BEND 45'BEND&WYES REDUCERS& NEW HOTMIX FITTING 22tF BEND ASPHALT PATCH I SIZES AREA H x B AREA H x B AREA H x B AREA H x B TO MATCH EXISTING PER CITY EXISTING ASPHALT i OF BOZEMAN SPECIFICATIONS EXISTING q CULATING 4" 2.7 3.8 2.1 1.1 (6'-6"MINIMUM RBURY) 8" 9.6. 13.6 74 3.8 E%IS11NG IIIrr��� 10" 14.5 20.5 11.1 5.7 X91E;_ HWSE OF CLEAN 12" 20.5 29.0 15.7 8.0 MIN 6'-6°OF BUILDING I 14° 27.6 39.0 21.1 10.8 COVER ABOVE LAYBACK TRENCH AS I COMPACT TO 95% TOP OF PIPE. REQUIRED NOTES: RELATIVE DENSITY 1)THIS TABLE BASED ON 200 PSI MAIN PRESSURE UNDER PAVEMENT I AND 2000 PSF SOIL BEARING PRESSURE: I i 2)WRAP ALL FITTINGS OATH POLYETHYLENE. UNDISTURBED NATIVE SOIL � TRENCH CUT N AS 3 THE BEARING SURFACE SHOULD BE PLACED AGAINST UNDISTURBED SOIL o°000 FOR NEW FIRE SERVICE. ) PROVIDE NEW SOD REPAIR I A oqo�o AFTER INSTALLATION. I °, o�0 i BACKFlLL&CONSOLIDATE 1 3 TOO OF PIPE PATH SAND. THRUST BLOCKING DETAIL FIRE ON Pu SSIff AS NOTED �I WATER MAIN BY CITY OF BOZEMAN. C1 NO SCALE MIN.6°SAND (AT 0 ER'S EXPENSE)8"x8"TAPPING UNDERLAYMENT. SADD ,TAPPING VALVE,AND ROAD BOX. �� '^ - - TO NEW CLASS I SPRINKLER SYSTEM I ` T NEW FIRE LINE SECTION NEW B°CLASS 'I DUCTILE I C� NO SCALE IRON FIRESERVICE REPLACE SIDWALK TO MATCH SITE PLAN - UNDERGROUND O EXISTING,SEE 5/C1 REPLACE ASPHALT TO MATCH NOTE:RADIANT fLOIXt HEATING NOTE:RADIANT FLOOR HEATING EXISTING,SEE 2/C1 PRESENT COORDINATE WITH OWNER PRESENT COORDINATE WITH OMER BEFORE CUTTING CONCRETE FLOOR BEFORE CUTTING CONCRETE FLOOR SAW CUT AND PATCH 2'-6" CONCRETE FLOOR AS NECESSARY.SEE 8°OS&Y GATE VALVE-MEULLER MODEL R-2360-6 DETAIL 5/1 Lc I BY FIRE SPRINKLER CONTRACTOR DRILL HOLE 6"DEEP IN BY UTILITY EXISTING CONCRETE 104 FOR 2'-6" CONTRACTOR 1'-0"OF YC REPAR AT PATCH CONCRETE FLOOR 16"ON CENTER AIR NEW CONCRETE EXISTING SEE DETAIL 5/C1 _N MINIMUM EDI W,INSTALLED IN EVERY OTHER PERIMETER OF AREA PATCH CONCRETE OF THE AVAILABLE M.J.FLANGE BOLT HOLES.(TYPICAL) TO BE PATCHED 102 ,DT ((ITT 11I II, IIT2 liI THRU NEW(CONCRETE// 100 NEW 8"RISERJ ]I111,-11�11-1�FLOOR FILL W SILICONE MASTIC I ----��-----SAW CUT AREA OF EXISTING EXISTING -nalau-III-I_ / _ -III=I I=I i I JI'II --i-O O—RING - p-_AIP-S IN_-NECESSARY FOR CONCRETE COMPACTED LL EXISTING SOIL EXISTING CONCRETE 13"FIRE SERVICE ATON. FW NDAl0N I- UTILITY CONTRACTOR L-------------------------- CONCRETE PATCH DETAIL 98 T= B=1111rFIIF((rn T 71�_II=1r-1r Ir-Im=_ 94 - 1 92 - ------- ---=— EXACT FOOTING CONFIGURATION 90 t UNDER CONCRETE WALL IS UNKNOWN. _ II CONTRACTOR TO VERIFY. r N- RECORD DOCUMENTS '�L 1-I THESE RECDRD DOCUMENTS HAVE BEEN PREPARED BASED 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 THRUST BLOCKING.� - \—NEW COMPACTED ON INPORUNTON PROMOFO BY OTHERS. SPRNxLDe TEaNOIOGw SEE DETAIL 3/C1 FILL DESIGN,INC. HAS NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS DP THIS INFORMATON AND SHALL NOT BE RESPONSIBLE FOR ANY ERROR OR 0MISSKKIS MN MAY BE NOTE:BE ADVISED THAT IF LESS THAN 6%FEET OF COVER OVER THE SERVICE LINE IS OBTAINABLE,THE LINE WALL HAVE TO BE INSULATED. � FIRE SERVICE FLOOR PENETRATION INCORPORATED HERDN AS A RESULT. °1 1/2"=1'-0" 05-30-2014 FIRE LINE PROFILE C7 NO SCALE NOTICE ENGINEER APPROVALS & COORDINATION CITY OF BOZEMAN UNDERGROUND NOTES BYO 14 P REVISIONS CONTRACT NAME: Sprinkler HOUSE OF CLEAN oacTMZATKIN CONTACT PHONE CITY OF BOZEMAN AND THE COMPLETION OF A PRE CONSTRUCTION MEETING 0 C N0. DATE DEsrnlvnoN 332 GALLATIN PARK 1) ALL UNDERGROUND PIPE IS TO BE INSTALLED IN ACCORDANCE NTH MONTANA 4) INTERIOR FIRE SPRINKLER SYSTEM SHALL BE PROVIDED. h IT IS THE OWNERS RESPDNSIBUTY arr aF BozEMAM ANDY KERR (a06)BB2-2280 PUBLIC WORKS STANDARD SPECIFICATIONS,FIFTH EDITION(MARCH 2O03);CITY 5) NEW 8"FIRE SERVICE LINE SHALL BE CHLORINATED,PRESSURE TESTED CONDUCTED BY THE ENGINEER. q 2 BOZEMAN,MT 59715 WMWK Br..J. •ANDERS OF BOZEMAN MODIFICATIONS TO MPW FIFTH EDITION(ADDENDUM 2 6/28/06);AND B) CONTRACTOR SHALL PROVIDE AS-BUILT OF NEW FIRE LINE TO ENGINEER. a y Technology DAM' er.J. 02-2014 ro vROVTDE ADEQUATE HUT m AND PASS BACTERIOLOGICAL TESTING AS PER MPW AND CITY OF BOZEMAN PREVENT FREEZING THROUGII°UT ENGINEER SHALL PROVIDE AS BUILT TO CITY OF BOZEMAN. a �. CONTRACT wTH: DAM' THE CITY OF BOZEMAN FIRE SERVICE LINE STANDARD(REVISED APRIL 24,2006) REQUIREMENTS.NEW 8"FIRE SERVICE LINE SHALL BE INSTALLED YA1H NO 01-02-2014 MtE PIPE SPRINKLER SYSTEM 9 ALL FITTINGS SHALL HAVE A MINIMUM PRESSURE RATING OF 175 PSI. d 2)"CONTRACTOR'S MATERIAL AND TEST CERTIFICATE FOR UNDERGROUND OF BOZEMAN LESS COVER THAN THAT OVER THE EXISTING WATER MAIN AND EVERY ) � q d� Design, Inc. HOUSE OF CLEAN SPRIN ACT Na: AREAS AND w ENDLosuREs PIPING"IS TO BE COMPLETED AND SUBMITTED TO THE CITY W BOZEMAN ATTEMPT SHOULD BE MADE TO OBTAIN THE MINIMUM REQUIREMENT OF 10) FIRE SERVICE LINE WILL NOT BE TURNED ON UNTIL INSTALLATION 332 GALLATIN PARK SPPoNK TECH.NQ:13174 FOR DRY PIPE AND OTHER TYPES PRIOR TO THE FINAL ACTIVATION OF THE FIRE SERVICE LINE 6'-6"OF COVER. OF REDUCED PRESSURE DOUBLE CHECK VALVE ASSEMBLY IS COMPLETE. 2011 North 22nd Avenue Suite #4 332 GALL MT SPARS SHEET No.: OF VALVES CONTRIXING WATER SYSTEM TYPE 6) APPLICATIONS FOR THE NEW WATER SERVICE SHALL BE MADE AT CITY 11) MATERIAL SUBMITTALS SHALL BE SUBMITTED TO CITY OF BOZEMAN TWO DAYS Bozeman, MT 59718 3) NO CONNECTION IS TO BE MADE BETWEEN THE INTERIOR FIRE SPRINKLER Phone 406-582-1936 Fax 406-585-8332 � SUPPNES TO SPRNKLER SYSTEMS OFFICES(20 E.OLIVE)PRIOR TO START W CONSTRUCTION. PRIOR TO PRE CONSTRUCTION MEETING(MINIMUM). y wu cuss T PIPING AND THE 8°I VALVE,UNTIL THE UNDERGROUND Email info®s rinklertechnolo desi n.com DescPoPnoN: DRY PORTION OF THE SYSTEM HAS BEEN ACCEPTED BY THE CITY OF BOZEMAN. 7) NO WORK IS TO BEGIN PRIOR TO RECEIVING WRITTEN APPROVAL BY THE 12) PROJECT REQUIRES ADEQUATE ENGINEERING INSPECTION. P B➢ B NEW UNDERGROUND FlRE SERVICE PLANS AND DETAILS