HomeMy WebLinkAboutWest Winds Applicant MaterialsWEST WINDS PLANNED COMMUNITY PUD
CONCEPT PUD MODIFICATION APPLICATION
AND
WEST WINDS SUBDIVISION PHASE 5
SUBDIVISION PRE-APPLICATION
July 2015
Prepared for:
ASCH, LLC
PO Box 12037
Bozeman, MT 59718
Prepared by:
WEST WINDS PLANNED COMMUNITY PUD
CONCEPT PUD MODIFICATION APPLICATION
4
Concurrent Construction
A request for concurrent construction, as allowed per Section 38.39.060 of the Unified
Development Code, is included as part of this application. The applicant would like to begin
construction of the residential dwellings prior to the completion of all of the infrastructure
improvements. Water supply and wastewater treatment would be installed, tested and
approved by the City of Bozeman prior to any vertical construction. In addition, streets
proposed with the subdivision of the lots within the concept PUD would be constructed to a
city gravel standard and all private utility providers would be given an opportunity to install
services at their discretion prior to the construction of any residential dwellings. As part of
this request, the applicant would enter into an improvements agreement with the City of
Bozeman to financially guarantee all of the remaining improvements prior to the final
platting of any subdivision phases.
Included as part of the preliminary plat application submittal, the applicant is proposing a
facilities plan to better coordinate the installation schedules in a manner acceptable to the
various City of Bozeman departments. The preliminary plat application would also include a
narrative addressing the 13 criteria from Section 38.39.030.D of the Unified Development
Code.
Parks, Trails and Open Space
According to the updated parkland tables for the amended West Winds PUD, the Phase V
subdivision was allocated a total of 1.110 acres of parkland which would meet the
dedication requirements for 37 units. As is indicated on the Phase V subdivision plat, .78
acres (26 units) of dedicated parkland requirements were met for the properties that are the
subject of this request. Based on the concept proposed, a total of 54 single family lots would
be platted with a subdivision which would require a total dedication of 1.62 acres. As a
result, a balance of .84 acres of dedicated parkland is required. As part of the development
of the subject properties, the applicant will be completing un-improved portions of the West
Winds Community PUD parklands. Figure 4 illustrates the relation of the concept PUD area
to the surrounding park and trails network and indicates the park and trail areas to be
improved as development occurs over time.
0 400 800200
Feet
VAQUERO PARKWAY
DAVIS LANEI
HUNTERS WAYLOT 1
LOT 1
BLOCK 3
BLOCK 4
SOURCE: CITY OF BOZEMAN GIS DEPARTMENT
W. OAK STREET
WEST WINDS PLANNED COMMUNITY PUD
CONCEPT PUD MODIFICATION APPLICATION
5
Transportation Network
Figure 5 illustrates the transportation network surrounding the subject properties based on
the functional classification method adopted in the Greater Bozeman Area Transportation
Plan. As noted throughout this narrative, one of the unique concepts proposed with this
application is an alternative local street section. Due to the irregular shape of the properties
and the adjacency to arterials with limited access points, an uncommon design philosophy
has been employed to allow for increased lot density while maintaining a functional access
network.
Most of the interior streets within the concept PUD would utilize a modified local street
section within a 45-foot right of way. Essentially, this section is a typical local street with a 6-
foot curb walk in-lieu of the standard 5-foot sidewalk and no landscaped boulevards. The
premise behind this proposal is that seasonal variation may allow for alternative methods in
a situation where the traffic volumes are relatively low due to the total number of properties
accessed. Specifically, if the landscaped boulevard provides area for automobile and
pedestrian separation along with snow storage in the winter, dedicated bike and parking
lanes can serve as pedestrian buffers year round and the bike lane should be able to
account for large quantities of snow storage in the circumstances where that storage is
necessary and the utilization of the lane for bike travel is likely low.
0 200 400100
Feet
WINTER PARK STREET
DAVIS LANEI
HUNTERS WAYLOT 1
LOT 1
BLOCK 3
BLOCK 4
SOURCE: CITY OF BOZEMAN GIS DEPARTMENT
W. OAK STREET
WEST WINDS PLANNED COMMUNITY PUD
CONCEPT PUD MODIFICATION APPLICATION
6
Summary
As noted throughout this application, this concept PUD is intended to promote a tailored
strategy to create a place for a specific housing type. As such, the applicant is requesting
that an unconventional approach be considered to allow for a preferable product. Single
family lot ownership has been found to be a favorable alternative to condominium unit
ownership due to an increased capability to secure financing in the current lending
environment. The idea behind this concept is that smaller homes constructed on smaller
lots outside of the conservation overlay district should provide a price point that is
accessible to a broader segment of the marketplace.
THE AMENDED PLAT OF WEST WINDS
SUBDIVISION PHASE 5
SUBDIVISION PRE-APPLICATION
July 2015
Prepared for:
ASCH, LLC
PO Box 12037
Bozeman, MT 59718
Prepared by:
Subdivision Pre-application Required Materials PA Page 1 of 2 Revision Date 4-27--15
Required Forms: A1 Recommended Forms: Presentation of submitted plans and specifications
CITY OF BOZEMAN
DEPARTMENT OF COMMUNITY DEVELOPMENT
SUBDIVISION PRE-APPLICATION PLAN
REQUIRED MATERIALS
APPLICATION SETS
3 total sets are required that include 1 copy of every item below bound or folded into 8½ x 11 or 8½ x 14 sets
Complete and signed development review application form A1.
Plan sets that include all required items listed on the subdivision pre-application checklist form
PA1.
Standard application sets required plan sizes: 2 sets that include full size 24 x 36 inch plans 1 set that include 11 x 17 inch plans
2-digital versions of all materials (JPEG or PDF) on separate CD-ROMs or USB drives. Individual files must be provided at 5MB or less in size. Files shall be named according to naming protocol.
Notes:
All plans must be drawn to scale on paper not smaller than 8½ x 11 inches or larger than 24 x 36 inches. The name of the project must be shown on the cover sheet of the plans. If 3-ring binders will be used, they must include a table of contents and tabbed dividers between
sections. Plans that are rolled or not bound into sets will not be accepted.
STATISTICS
1.Subdivision Type:
First Minor Subdivision from a Tract of Record
First Minor Subdivision from a Tract of Record with variance
Second or Subsequent Minor Subdivision from a Tract of Record
First Major Subdivision
2.Total Number or Lots:
3.Lots by Proposed Uses:
Residential, single household City Park
Residential, multi household Manufactured Home Space
Planned Unit Development Open Space Recreational Vehicle Space
Condominium Unit Commercial
Townhouse Industrial
Common Open Space Restricted Development
Other:
APPLICATION FEE
Base fee $375 Minor or $820 Major
Plus $40 per lot
PA
54
54
Subdivision Pre-application Required Materials PA Page 2 of 2 Revision Date 4-27--15
Required Forms: A1 Recommended Forms: Presentation of submitted plans and specifications
APPLICATION DEADLINES
Applications received by a rolling deadline of Wednesday at 5pm will be reviewed to determine if
they are acceptable within five working days of the application deadline. Applications deemed
acceptable for review will begin Development Review Committee review in ten working days from
the application deadline.
CONTACT US
Alfred M. Stiff Professional Building
20 East Olive Street 59715 (FED EX and UPS Only)
PO Box 1230
Bozeman, MT 59771
phone 406-582-2260
fax 406-582-2263
planning@bozeman.net
www.bozeman.net
WEST WINDS PLANNED COMMUNITY PUD
CONCEPT PUD MODIFICATION APPLICATION
Table of Contents
Development Review Common Application Form (A1)
Planned Unit Development Checklist
Narrative
Introduction
Vicinity Map
Concept PUD Modification Exhibit
Suggested Modifications
Historical Land Use Plans Inset
Relaxations
Concept Layout Plan Exhibit
Concurrent Construction
Parks, Open Space & Trails
Park and Trail Network Exhibit
Transportation Network
Access Network Exhibit
Street Sections
Summary
WEST WINDS SUBDIVISION PHASE 5
SUBDIVISION PRE-APPLICATION
Table of Contents
Subdivision Pre-Application Plan Form (PA)
Pre-Application Plan
Waiver Request
Zoning Map
Topography Map
F:\Projects\Mark Easton\West Winds PUD-PreApp 102.06\Text\Pre-App\WaiverRequest(COB).docx
The Amended Plat of West Winds Subdivision Phase 5
Subdivision Pre-Application
Waiver Request
A request to waive the requirement to provide the following supplemental information from
Section 38.41.060 is being included with this Pre-Application submittal. As noted in this Pre-Application plan review request, the subject properties are located within an approved
subdivision. As such, the physical conditions and the methods proposed to mitigate any potential impacts remain the same.
As part of the Preliminary Plat Application, a digital copy of the original reference materials will be provided. A summary response as to the reasoning for each requested waiver is provided, where appropriate, on the following list in bold italics.
1. Surface water.
a. Mapping. Locate on a plat overlay or sketch map all surface waters and the delineated floodplain which may affect or be affected by the proposed subdivision including:
(1) Natural water systems such as natural streams, creeks, stream/ditches, drainages, waterways, gullies, ravines or washes in which water flows either continuously or intermittently
and has a definite channel, bed and banks.
(2) Artificial water systems such as canals, ditches, ditch/streams, aqueducts, reservoirs, irrigation or drainage systems.
b. Description.
(1) Describe all surface waters which may affect or be affected by the proposed subdivision including name, approximate size, present use and time of year when water is present. (2) Describe proximity of proposed construction (such as buildings, sewer systems, streets) to
surface waters
Surface water information was provided with the original subdivision application
submittal. The necessary permits were requested and granted. This information is also provided in the Environmental Assessment completed, reviewed and approved with the
original subdivision application. A copy of this information will be provided with the Preliminary Plat Application.
2. Floodplains. A floodplain analysis report shall be submitted with the preliminary plat in compliance with article 31 of this chapter.
The subject properties are not within the 100 year floodplain and, therefore are not subject to the provisions of Article 31. 3. Groundwater.
a. Depth. Establish the seasonal minimum and maximum depth to the water table, dates on
which these depths were determined, and the location and depth of all known aquifers which may be affected by the proposed subdivision. The high water table shall be determined from
tests taken during the period of major concern as specified in writing by the county
F:\Projects\Mark Easton\West Winds PUD-PreApp 102.06\Text\Pre-App\WaiverRequest(COB).docx
environmental health department. Specific locations for test holes may also be determined by the county environmental health department.
b. Steps to avoid degradation. Describe any steps necessary to avoid the degradation of groundwater and groundwater recharge areas.
Groundwater information was provided with the original subdivision application submittal. This information is also provided in the Environmental Assessment
completed, reviewed and approved with the original subdivision application. A copy of this information will be provided with the Preliminary Plat Application. Furthermore, groundwater resources will be unaffected by this subdivision as groundwater will not be
necessary to service the subdivision.
4. Geology; soils; slopes.
a. Geologic hazards. Identify geologic hazards affecting the proposed subdivision which could
result in property damage or personal injury due to rock falls or slides; landslides, mud or snow;
surface subsidence (i.e., settling or sinking); or seismic activity.
b. Protective measures. Explain what measures will be taken to prevent or materially lessen the danger of future property damage or injury due to any of the hazards referred to in subsection A.4.a of this section.
c. Unusual features. Provide a statement describing any unusual soil, topographic or geologic conditions on the property which limit the capability for building or excavation using ordinary and
reasonable construction techniques. The statement should address conditions such as shallow bedrock, high water table, unstable or expansive soil conditions, and slope. On a map, identify any slopes in excess of 15 percent grade.
d. Soils map. The subdivision shall be overlaid on the county soil survey maps obtained from
the Natural Resource and Conservation Service (NRCS). The maps are 1:24,000 in scale.
These maps may be copied without permission. However, enlargement of these maps could cause misunderstanding of the detail of mapping. Soils were mapped using a minimum
delineation of five acres, and these soils reports were intended to alert developers to possible
problems and the need for a more detailed on-site investigation. The developer shall provide the following soil reports, which can be obtained from the NRCS:
(1) The physical properties and engineering indexes for each soil type; (2) Soil limitations for building and site development, and water features for each soil type;
(3) Hydric soils report for each soil type. If hydric soils are present, the developer shall provide a wetlands investigation by a certified consultant, using the Federal Manual for Identifying and Delineating Jurisdictional Wetlands (January 1987); and
(4) The developer shall provide any special design methods planned to overcome the above limitations.
e. Cuts and fills. Describe the location and amount of any cut or fill three or more feet in depth. These cuts and fills should be indicated on a plat overlay or sketch map. Where cuts or fills are
necessary, describe any plans to prevent erosion and to promote revegetation such as
replacement of topsoil and grading.
Information regarding geology, slopes and soils was provided with the original subdivision application submittal. This information is also provided in the Environmental
F:\Projects\Mark Easton\West Winds PUD-PreApp 102.06\Text\Pre-App\WaiverRequest(COB).docx
Assessment completed, reviewed and approved with the original subdivision application. A copy of this information will be provided with the Preliminary Plat Application.
Information regarding geology, slopes and soils will not be necessary for the review of this subdivision. The subject property is relatively flat and there are no geologic irregularities or unusual soil characteristics that would make this site less suitable for
development than that of the surrounding properties. 5. Vegetation.
a. Vegetation map. On a plat overlay or sketch map:
(1) Indicate the distribution of the major vegetation types such as marsh, grassland, shrub, coniferous forest, deciduous forest or mixed forest.
(2) Identify critical plant communities such as stream bank or shoreline vegetation; vegetation
on steep, unstable slopes; and vegetation on soils highly susceptible to wind or water erosion.
b. Protective measures. Describe measures to preserve trees and critical plant communities
(e.g., design and location of streets, lots and open spaces).
Vegetation information and Weed Management measures were outlined in the Environmental Assessment as part of the original subdivision. A copy of the Environmental Assessment will be provided in the Preliminary Plat Application.
Detailed information regarding vegetation, beyond the preparation of a weed management plan, will not be necessary. The site does not harbor any critical plant communities and is no more susceptible to slope degradation or erosive factors than
that of the surrounding properties. 6. Wildlife.
a. Species. Describe species of fish and wildlife which use the area affected by the proposed
subdivision.
b. Critical areas. Identify on a plat overlay or sketch map of the proposed subdivision any known
critical, significant or "key" wildlife areas, such as big game winter range, waterfowl nesting
areas, habitat for rare or endangered species or wetlands.
c. Pets/human activity. Describe the expected effects of pets and human activity on wildlife. d. Public access. Describe the effects on public access to public lands, trails, hunting or fishing
areas. e. Protective measures. Describe any proposed measures to protect or enhance wildlife habitat
or to minimize degradation (e.g., keeping building and streets back from shorelines, setting aside marshland as undeveloped open space).
f. Discussion of impact; documentation. The developer shall discuss the impact of the proposed development on fish and wildlife with the state department of fish, wildlife and Parks (FWP).
With the preliminary plat, the developer shall provide written documentation from FWP that:
(1) Verifies that FWP has reviewed the proposed plat;
(2) Lists any FWP recommendations; and
(3) Outlines any mitigation planned to overcome any adverse impacts.
F:\Projects\Mark Easton\West Winds PUD-PreApp 102.06\Text\Pre-App\WaiverRequest(COB).docx
Wildlife information was provided in the Environmental Assessment as part of the original subdivision. A copy of the Environmental Assessment will be provided in the
Preliminary Plat Application. The subject property is within the corporate limits of the City of Bozeman. As a result, future development of the site has been anticipated through both the annexation and zoning of the property. The property is not considered
critical wildlife habitat. Therefore, impacts to wildlife are not expected. 7. Historical features.
a. Affected areas. Describe and locate on a plat overlay or sketch map any known or possible historic, paleontological, archaeological, or cultural sites, structures, or objects which may be
affected by the proposed subdivision.
b. Protective measures. Describe any plans to protect such sites or properties.
c. Procedures. Describe procedures to be followed if any historic, paleontological,
archaeological, cultural sites, structures or object are found on site during site preparation and
construction.
d. Discussion of impact; documentation. The developer shall discuss the impact of the proposed development on any historic features, and the need for inventory, study and/or preservation with the state historic preservation office (SHPO). The developer shall provide written documentation
from SHPO that: (1) Verifies that SHPO has reviewed the proposed plat;
(2) Lists any SHPO recommendations; (3) Outlines any plans for inventory, study, and/or preservation; and (4) Describes any mitigation planned to overcome any adverse impacts.
e. Preparation of information. Information on historical sites shall be prepared by a qualified
professional, including persons with a professional or educational background in history,
architectural history, archaeology, art history, historic preservation, anthropology and cultural resource management.
Information regarding historical features was provided in the Environmental Assessment as part of the original subdivision. A copy of the Environmental Assessment will be
provided in the Preliminary Plat Application. The State Historic Preservation Office will be notified of this subdivision proposal through a customary comment solicitation. Should any items of historical significance be identified through that process, mitigation
efforts will be included in the preliminary plat application materials. 17. Neighborhood center plan. A neighborhood center plan shall be prepared and submitted
for all subdivisions containing a neighborhood center. This item was discussed in the Environmental Assessment included in the original subdivision application. A copy of the Environmental Assessment will be provided with the Preliminary Plat Application for this subdivision.
19. Miscellaneous.
a. Public lands. Describe how the subdivision will affect access to any public lands. Where
public lands are adjacent to or within 200 feet of the proposed development, describe present
F:\Projects\Mark Easton\West Winds PUD-PreApp 102.06\Text\Pre-App\WaiverRequest(COB).docx
and anticipated uses for those lands (e.g., open space, recreation, etc.), and how public access will be preserved/enhanced.
These items were discussed in the Environmental Assessment included in the original subdivision application. A copy of the Environmental Assessment will be provided with
the Preliminary Plat Application for this subdivision. This subdivision proposal will not have any effect on public lands as none are adjacent to the subject property. 20. Affordable housing. Describe how the subdivision will satisfy the requirements of chapter 10, article 8. The description shall be of adequate detail to clearly identify those lots designated as subject to chapter 10, article 8 compliance requirements and to make the obligations placed
on the affected lots readily understandable.
a. On all lots intended to be used to satisfy the requirements of chapter 10, article 8, the
allowable building envelope shall be depicted.
Though this particular provision is not required at this time, a detailed discussion as to this subdivisions role in the provision of affordable housing will be detailed throughout the preliminary plat application.
R-3
R-1
PLI
R-3
B-2
R-2
0 400 800200
Feet
W. OAK STREETDAVIS LANESUBJECT
PROPERTY
I
WEST WINDS PLANNED
COMMUNITY PUD
CONCEPT PUD MODIFICATION APPLICATION
July 2015
Prepared for:
ASCH, LLC
PO Box 12037
Bozeman, MT 59718
Prepared by:
Development Review Application A1 Page 1 of 3 Revision Date 4-27-15
Required Forms: Varies by project type Recommended Forms: Presentation of submitted plans and specifications
CITY OF BOZEMAN
DEPARTMENT OF COMMUNITY DEVELOPMENT
DEVELOPMENT REVIEW APPLICATION
1. PROJECT
Development
Name:
Description:
2. PROPERTY OWNER
Name:
Full Address:
Phone:
Email:
3.APPLICANT
Name:
Full Address:
Phone:
Email:
4. REPRESENTATIVE
Name:
Full Address:
Phone:
Email:
5. PROPERTY
Full Street Address:
Full Legal Description:
Current Zoning:
Current Use:
Community Plan Designation:
A1
West Winds Planned Community PUD Concept PUD Modification Application &
West Winds Subdivision Phase 5 Subdivision Pre-Application
Concept PUD Modification & Subdivision Pre-Application
ASCH, LLC
PO Box 12037 Bozeman, MT 59719
406.581.9644
mark@eastonconcrete.com
Islands, LLC
PO Box 12037 Bozeman, MT 59719
406.581.9644
mark@eastonconcrete.com
Trever McSpadden c/o Haystack Development, Inc.
PO Box 1793 Bozeman, MT 59771
406.570.3830
trever@haystackdevelopment.com
West Oak Street & Davis Lane
Lot 1, Block 3 & Lot 1, Block 4 of West Winds Subdivision Phase 5, NW4 of Section 2, T2S, R5E
R-3
Vacant
Residential
Development Review Application A1 Page 2 of 3 Revision Date 4-27-15
Required Forms: Varies by project type Recommended Forms: Presentation of submitted plans and specifications
Overlay
District: Neighborhood Conservation Entryway Corridor None
Urban Renewal
District:
Downtown North 7th Avenue Northeast None
6. STATISTICS (ONLY APPLICATION TYPES 2-12, 17, 25 AND 27)
Gross Area: Acres: Square Feet:
Net Area: Acres: Square Feet:
Dwelling
Units:
Nonresidential Gross Building
Square Feet:
7. APPLICATION TYPES
Check all that apply, use noted forms. Form Form
1. Pre-application Consultation None 17. Informal Review INF
2. Master Site Plan MSP 18. Zoning Deviation None
3. Site Plan SP 19. Zoning or SubdivisionVariance
Z/SVAR
4. Subdivision pre-application PA 20. Conditional Use Permit CUP
5. Subdivision preliminary plat PP 21. Special Temporary Use
Permit
STUP
6. Subdivision final plat FP 22 Comprehensive Sign Plan CSP
7. Subdivision exemption SE 23. Zoning Verification ZV
8. Condominium Review CR 24. Regulated Activities inWetlands
RW
9. PUD concept plan PUDC 25. Zone Map Amendment (non
Annexation)
ZMA
10. PUD preliminary plan PUDP 26. UDC Text Amendment ZTA
11. PUD final plan PUDFP 27. Growth Policy Amendment GPA
12. Annexation and Initial Zoning ANNX 28. Modification/PlanAmendment
MOD
13. Administrative Interpretation
Appeal
AIA 29. Extension of Approved Plan EXT
14. Administrative Project Decision
Appeal
APA 30. Reasonable
Accommodation
RA
15. Commercial Nonresidential COA CCOA 31. Other:
1 6. Historic Neighborhood Conservation Overlay COA
NCOA
8.APPLICATION FEES AND MATERIALS
A. Fees are to be provided based upon the adopted fee schedule FS. Contact our office for an
estimate.
B. Applications received by a rolling deadline of Wednesday at 5pm will be reviewed to determine if they are acceptable within five working days of the application deadline. Applications deemed acceptable for review will begin staff review immediately or be scheduled for Development Review Committee review in ten working days from the application deadline.
7.24 315,374
5.25 228,690
54
N/A
Development Review Application A1 Page 3 of 3 Revision Date 4-27-15
Required Forms: Varies by project type Recommended Forms: Presentation of submitted plans and specifications
C. Application materials shall be submitted for each application as shown in the specific guidance and checklists that is provided for each application type. A common development review application form and common notice materials may be provided for an application that includes more than one application type. All other application materials shall be submitted for each individual application type per the project guidance and checklists.
9. CERTIFICATIONS AND SIGNATURES
This application must be signed by both the applicant(s) and the property owner(s) (if different)
before the submittal will be accepted. As indicated by the signature(s) below, the applicant(s) and property owner(s) submit this application for review under the terms and provisions of the Bozeman Municipal Code. It is further indicated that any work undertaken to complete a development approved by the City of Bozeman shall be in conformance with the requirements of the Bozeman Municipal Code and any special conditions established by the approval authority. I acknowledge that the City has an Impact Fee Program and impact fees may be assessed for my project. Further, I agree to grant City personnel and other review agency representative’s access to the subject site during the course of the review process (Section 38.34.050, BMC). I (We) hereby certify that the above
information is true and correct to the best of my (our) knowledge.
Certification of Completion and Compliance – I understand that conditions of approval may be
applied to the application and that I will comply with any conditions of approval or make necessary corrections to the application materials in order to comply with municipal code provisions. Statement of Intent to Construct According to the Final Plan – I acknowledge that construction not in compliance with the approved final plan may result in delays of occupancy or costs to correct noncompliance.
Applicant Signature:
Printed Name:
Owner Signature:
Printed Name:
Owner Signature
Printed Name:
If signing as a corporation, please provide the title and position of the individual signing on behalf of
the corporation. Attach separate sheets for additional owner signatures.
CONTACT US
Alfred M. Stiff Professional Building
20 East Olive Street 59715 (FED EX and UPS Only)
PO Box 1230
Bozeman, MT 59771
phone 406-582-2260
fax 406-582-2263
planning@bozeman.net
www.bozeman.net
WEST WINDS PLANNED COMMUNITY PUD
CONCEPT PUD MODIFICATION APPLICATION
1
Introduction
The West Winds Planned Community PUD was originally approved in 2004. As part of the
overall vision for the PUD, a set of uses and corresponding densities were proposed that
would develop over several years depending on market conditions. As part of this particular
modification request, the applicant is asking that a portion of the original PUD area,
specifically Lot 1 Block 3 and Lot 1 Block 4 of the Phase 5 subdivision, be allowed to be
developed as single family lots in lieu of the senior living facility configuration that was part
of the original approval.
As is the case with many PUD proposals that intend to develop a larger area over a
relatively long period of time, some modifications are necessary throughout the life of the
PUD approval to adjust to evolution in the marketplace. As a result, an amendment to the
original PUD was requested in 2008. The 2008 amendment superseded the 2004 approval
and is the version that will be further amended should this request be approved. Included in
the amended PUD was an alternative land use and density scenario for the properties that
are the subject of this modification request. A “Residential Alternative” was proposed that
would allow for the platting of single family lots like that of the request being made with this
application. The reasoning behind the amendment request in 2008 was similar in that the
applicant was asking for some flexibility in the entitlements to broaden the development
potential of the subject properties while maintaining the spirit of the original PUD approval.
The objective of this proposal is simple. The applicant is asking to execute a version of the
land uses requested with the 2008 amendment. Included in this request, is the utilization of
some of the PUD relaxations granted with both the original PUD approval along with the
addition of a series of new relaxations to allow for some of the unique characteristics of the
lot configuration proposed as part of this amendment request.
Throughout the narrative that follows, and the discussions that will be had as this request
moves through the process, will be a focus on how this particular request, developed in the
manner suggested here, can contribute to the provision of housing at an entry-level price
point. One of the themes that echoes throughout the West Winds Planned Community PUD,
including the iterations that followed the original approval, is how this PUD will provide
“affordable housing”. The Bozeman Community Plan notes the importance of a variety of
housing types which may provide options for certain city residents where non currently
exist. With that, this request is intended to adhere to the principles West Winds Planned
Community PUD and the goals and objectives of the Bozeman Community Plan.
WEST WINDS PLANNED COMMUNITY PUD
CONCEPT PUD MODIFICATION APPLICATION
2
Suggested Modifications
The initial Land Use Plan for the West Winds Planned Community PUD in 2004 designated
the properties that are the subject of this request as “Senior Living Area”. The Master Plan
included a schematic plan that allowed for the potential of an assisted living facility along
with some independent living properties in the form of stand-alone condominiums. As part
of the current entitlement secured as part of the 2008 PUD amendment, the senior living
area concept was carried over. However, an alternative scenario for the southwestern
portion of the site was presented that included a single family and townhouse lot
configuration.
Throughout the various iterations of the plan, the uses and densities have been generally
similar to those which are proposed with this request. The concept proposed with this
request will increase density on this portion of the PUD area in an effort to generate the
number of lots necessary to make this type of project feasible.
2004 2008
WEST WINDS PLANNED COMMUNITY PUD
CONCEPT PUD MODIFICATION APPLICATION
3
Relaxations
The primary consideration for this application is a request to add relaxations from the
Unified Development Code to the list of approved relaxations within the West Winds
Planned Community PUD. The reasoning behind the request for additional relaxations is
concentrated on the unique lot configuration proposed with this concept PUD. As noted, the
objective of this development is to create lots for an entry-level housing product while
providing adequate accesses and utilities to service them.
In this scenario, a certain volume of properties is necessary to keep the project feasible. As
a result, the design philosophy behind this concept PUD is to create as many single family
and townhouse lots on an irregularly shaped parent parcel as possible. To achieve this,
some deviation from the typical design standards is required.
This concept will utilize the following relaxations that have been approved in the past and
are included as existing entitlements on the subject properties:
Section 38.23.030.C “Double/Through and Reverse Frontage” to allow for double
frontage on lots adjacent to arterial streets with limited access and one local street.
Section 38.23.040.B “Block Length” to allow the block length to exceed 400-feet on
one of the blocks within the proposed subdivision.
Section 38.23.040.C “Block Width” to allow the minimum block width to be less than
200-feet to accommodate the unique lot configuration proposed.
In addition, a request to consider the following relaxations to accommodate the proposed lot
configuration include:
Section 38.08.040.A (Table 38.08.040-1) “Minimum Lot Area” to allow for single
family lots in the subject portion of the PUD area to be less than 5,000 square feet.
Section 38.24.050.A.1 “Right of Way Width” to allow for access streets with the
subject portion of the PUD area to differ from the standards outlined in the UDC, the
Greater Bozeman Area Transportation Plan, the City of Bozeman Design Standards
and Specifications Policy and the City of Bozeman Modifications to Montana Public
Works Standard Specifications.