Loading...
HomeMy WebLinkAboutAutoZone_FireService 0 O ch J LL O FIRE SERVICE LINE IMPROVEMENTS MCO M �-W WW W N = Cz r ~ AUTOZONE STORE DEVELOPMENT �ui W = oLL Lnscow N W L \ SIDNer 1 r g w _ - CVS RETAIL CENTER � IaLeNw I -4- 1�169�OULAI NAL N ` I '' LeNnsT 1 r I �U��uT r r ► ��eII 17 5 Nm 19 T H AVE , = EE r_ J .80iern IBILLINGS r NI1RDNi 1 "•may' N _ f c �. OIILAII j r \ J J + F— I 120 ��. �_�' -�,— �= BOZEMAN MONTANA z scale mlea L-u �\ W O \ O co p z. \ C ' / \ Prepared for: ?d by: p a Z // \ F— W / w zZ w r 4 AutoZone ' I' _ i BOWL HKM 1 AutoZone' Orlve Boumen Inc. o • '� _ Ilr- ♦1 �'ri _ ob sslm ,Montana 1 w m u. 123 S. FRONT STREET, 3rd FLOOR a e MEMPHIS,TENNESSEE 38103 0 2J. NO.4522.11177.01 NOVEMBER 2013 SCALE: 1"=20' ti. " REVISIONS 1.11-01-2013 Ij v j g 1 2. 1 3. SHEET INDEX 31 SHEET N0. TITLE 4- 6 �I I I :• �t FS-1 COVER SHEET FS-2 FIRE SERVICE LINE PLAN & PROFILE 5 FS-3 DETAILS , 6 wESY?AA1N ME - ;�a f ,rt�.\yam" 2 rN f .y f J it x � � ' {'_ d7 ^' • .s wawa t* V y ENGINEER: P13Y SM _ idi `Q. MIEWER 1��" William R.Dreyer P.E 13853 / l DRAFTSMAN- BWD ,� / �. ���` Project Manager CHECKED BY:WRD 1 / w .�: DOWL HKM onrE 0610612013 7f t tj�, I. '• N oYf 3 n m'l El r j •� y�1J ,'� � ono RECORD DRAWING ��_ JUNE 2014 tl -CONTRACTOR NOTES: SHALL MAINTAIN 18" SEPERATION BETWEEN FIRE SERVICE LINE o DOMESTIC AND FIRE SERVICE LINE AT THE MAIN. ® 0 M 1 O -MAXIMUM DEFLECTION ALLOWED IS 3' (THREE DEGREES) PER PIPE I I al ( j t ry ap JOINT. _1 j r ;r r ' M -INTERIOR FIRE SYSTEM SHALL HAVE BACKFLOW PREVENTION AS j sr - �'f •�: ` W SHOWN IN CITY OF BOZEMAN STANDARD DRAWING NO. 02660-13. W () -THE FIRE SYSTEM WILL BE A CLASS I SYSTEM. A MINIMUM O ! ��. C W ORIFICE SIZE OF 2.5" IS REQUIRED TO ACHIEVE NFPA-24 / \, F- Z FLUSHING FLOWS. I �; `�)l (A Z 2+6 z IW- t! STj� 2 51190 D.00' 0 (A r _ I14 1 0 90' BEND N LL _ _W/ UST 6LOCKING 1 0 D ! t F N-1 461567 r186 / A., GENERAL NOTES: I.I I —E=1 0 1. THE LOCATION OF EXISTING UTILITIES SHOWN IS APPROXIMATE AND m I ' THE CONTRACTOR SHALL FIELD VERIFY PRIOR TO CONSTRUCTION. THE Z CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEANS TO4� PROTECT ALL EXISTING UTILITIES. m l Lr! g Ir -� / Y&LIAM R. ♦- 2. WHERE CONDITIONS ARE ENCOUNTERED WHICH APPEAR DIFFERENT I I , i _ ;, %l / _ IR'853 YER ` 13 PE FROM THOSE INDICATED ON THE PLANS OR IN THE SPECIFICATIONS. O+ rr —� 2h8 LF 4"0 D.I. _ STA 1+91.85 0.00' i - , �. ��� THE CONTRACTOR SHALL NOTIFY THE REPRESENTATIVE PRIOR TO THEIRE 1,Fjnmqrr : PERFORMANCE OF WORK. I 1 _ INSTALL 4"0 45' BEND /9ypyiilr,�` STA 0+15 0.00' I, I_) 1 O / ' 0- f I'- ��W/THRUST BLOCK �, 3. ALL WORK AND MATERIALS SHALL CONFORM TO THE LATEST EDITION CONNECT TO EXISTING ddd —�J�+3 / N=10335.993 OF THE CITY OF BOZEMAN MODIFICATIONS TO MONTANA PUBLIC (TAP BY COB) 1�30E=10335.993 WORKS STANDARD SPECIFICATIONS FIFTH EDITION, MONTANA PUBLIC N=10707.178 WORKS STANDARD SPECIFICATIONS FIFTH EDITION UNLESS INDICATED E=10506.732 �� z OTHERWISE ON THE CONTRACT DOCUMENTS. ORDER OF PRECEDENCE II �I ►►►JJJ SHALL BE CITY OF BOZEMAN MODIFICATIONS, FOLLOWED BY MONTANA STA 1+73.75 0.00'R N K LLI PUBLIC WORKS. II I INSTALL 4"0 45' BEND 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ANY AND S INSTALL TA 0+5 4"38 0.00' W/THRUST BLOCK a 0 22.5'BEND N=10716.450 I ALL UTILITIES IN THE AREA PRIOR TO BEGINNING ANY WORK ON THIS STA 0+39.37 0.00 W/THRUST BLOCKING E=10349.300 PROJECT. INSTALL 4"0 22.5' BEND N=10713.530 fl 5. THE CONTRACTOR SHALL PROVIDE A SET OF AS BUILT DRAWINGS TO W/THRUST BLOCKING E=10470.574 } THE REPRESENTATIVE PRIOR TO THE FINAL ACCEPTANCE. N=10708.066 LL I E=10462.375 I 0 6. ALL UTILITY TRENCHES SHALL BE BEDDED, BACKFILLED, AND COMPACTED PER CITY OF BOZEMAN STANDARD DETAIL NO. 02221-1. L 06 7. USE UNDERGROUND PIPE HAVING MECHANICAL OR PUSH-ON JOINTS 20 0 20 ao m MEETING AWWA C111. USE UNDERGROUND FITTINGS HAVING SCALE IN FEET MECHANICAL JOINTS MEETING AWWA C111. IF RESTRAINED JOINTS ATuj uj m FITTINGS ARE REQUIRED, USE MEGALUG MECHANICAL JOINT RESTRAINT I- ,n Z OR MEGAFLANGE RESTRAINED FLANGE ADAPTER, MANUFACTURED BY w ui �4 EBBA IRON SALES, OR UNI-FLANGE SERIES 1400 RETAINER GLANDS, C U> d J MANUFACTURED BY FORD METER BOX. WATER MAIN FITTINGS TO BE = o W THRUST BLOCKED SHALL BE IN CONFORMANCE WITH CITY OF WATER SERVICE - STA 0+00 TO STA 2+68 I s BOZEMAN STANDARD DRAWING NO. 02660-1 AND NO. 02660-3. o rjj°i V 7XZ 8. ANY EXISTING OR NEW VALVES WHICH CONTROL THE CITY OF 4830 4830 8> BOZEMAN WATER SUPPLY SHALL BE OPERATED BY CITY OF BOZEMAN "" "' U r� o PERSONAL ONLY. m w 9. THE CONTRACTOR SHALL NOTIFY THE WATER DEPARTMENT A MINIMUM """..... -"......"" "'""""'"" """"' •""'-"""""""" OF 24-HOURS PRIOR TO BEGINNING ANY WORK. 4825 LL : - -o— 4825 R .. -- .. ....................-... ._............... ......... ......... ......... ........I n Ill .............. .... ........ .,Y. 10. THE CONTRACTOR SHALL TEST AND FLUSH THE FIRE SERVICE LINE �� """ ""'" "' "' "0 a ACCORDING TO CITY OF BOZEMAN STANDARDS. Z ,........, ..... a _ z ---V.................... ... . .. ., p.......... ..... o m a LL 4820 m ..... ......... o m, zm. ..... .. m - 4820 SCALE: 1"=20' z m � .... -..wo o .:::.:: _ ........ ............:......::::.. .......,..c '' m REVISIONS Z m .. ...... +a.D m�. @ F, ....- AP R'OX. FINISHED........... ............. .�.. .. ........ s L 11-01-2013 4815 ram' m +^ of s GRADE. a, 4815 6. ic' N x APPROX. E'XIS NG . 3... �. 2. vc3 d pp E 3. ...... 4. 4810 ..- - 4810 M ..... SEWER.SERVICE... ... ... .. .:.. ..... 6. ............. .. 7. ` ............ .. .... ....... ..8'.5' MIN: .. ......... ... X LNG 4805 - 4805 ENGINEER PSY . .... N -- - ..•• 248 F 4 0 1 PIPE, •• DRAFTSMAN: BWU .... 4800 4800 CHECKED BY: WRD . .. .......... . ........................ ... - 08/06/2013 ... ...... . .. .... ..... . ... .aascr3�,r STA:0+ 5:00 .. tRsTAIL.FIRE.SER. CE . R RISER.PER CITY OF .... a QONNEC TO-EXISTING . . ARISER.N STA 4795 WATER' Aft-CONTRACTOR-TO— --- D--- 4795 F ;m . ......... ORAIMRG NO o2660, 13- ' VERIFY CATION, SIZE,-AND tr. DEPTH- IOR'TO-CONNECTING:-... -..- .. .. ..-. .. .. .L .. ......... ... .. ......................... a d ............... ........... .... ... .. ..... ......... Um ; 3 i ON O. o O 'r Ol 0 ip n n1 YIN N m Y o c>rry w C7 Do �'(7 so UYJ 7� RECORD DRAWING w w W W JUNE 2014 0+00 0+50 1+00 1+50 2+00 2+50 FS 2 b NOTES: ally F111e1es ALLOWED BERNMIl FAST OSAY WLYE AND No PFEsm oM1aEs oR PRF`�eE aura mrslm 1r11 E LEGEND .SEE O S HA SAFETY AND HEALTH NEGUTATIONS FOR ega111w ASg36y TO W®�' NOTE a N111wm es TIE lFsr roRn r Ivry eWalaw A49ely O 1.ALL IXCAVATION DEPn15 OVER 20 FEET MUST HAVE SLOPING CONSTRUCTION SECTIONS 1B2fi fi51 AN01926652 OR BENCHING SYSTEM DESIGNED BY REGISTERED PROFESSIONAL WATER MAIN ENGINEER OR SERVICE `I�I�/r1 -$FLANGED OS&Y VALVE 0 M 2WHERETRENCHPASSESTHROUGHIXISTINGPAVEMENT,THE O PAVEMENTSHALLBE CUTALONGA NEATVERTICAL UNEA nARxw a wWIrw w rw..r, LL r MINIMUM OF I2•FROMTHEEDGEOFTHETRENCH OPENING. r / mi W YY DOUBLE CHECK VALVE •p CO / •^^~� MIN. REQUIREMENT) v M WHERE NEAT LINE IS LESS THAN 3 FEET FROM THE EDGE OF 4'DR LARGER CLASS Si Ch AND OPAVEVrIRE AVEMENI-SE-O MRS AND N EEN,REMOVE AS INDICATED ON ANGREPLACEMEN'r.PAVEMENTSECTON BETWEEN TRENCH ANO EDGE OFPAVEMEm. DUCTILE IRON PIPE CTYP.) I Mtti y um.esowtt W 1.WMFNWVNStADlE at*acT MATFIWI,TRBNM WALLs*INt1 — nessD lloal APPROVED PLANS) r �W/1 BE BACK SLOPED FROM THE e0rWM OF THIS MNCH(TYPE 1 SEWERMAIN •••• .' '•'4'•-�. .�' �'•� ' �'."" '� LU Tn IXLAYATIDN).• aResevlcs 1 -• .••• -. .' U W (n —VERTICALTRENCH WALLS •MECHANICAL 3/4'MIN.Redl Rod, INSTALLED IN EVERY OTHER AVAILABLE M.J. C W wTHSHORING ULA_ORM Iwl O JORR BOLT HOLES (TYPICAL)-5/B'RODS ACCEPTABLE FOR 4'LINES L� Z 1�7' TOaeNAAVA-..IONSMATEM& MAINr IZLITYPE2IXCAVATONW' � p RAT.T.F. RRAN2F... _OUNDS 1rL2..rnGRWNDSURFACE BEND WTTH THRUST BLOCKc' Z 7 3 1r I - '-- B K/� � f/) Irw � EXISTING � BLOCK NEW3EWEROR WATER SEWER CITY OF BOZEM N REQUIREMENTS FOR INSTALLATION OF N LL \ MWSEWVICE OE WR TAPPING TEE VALVE, is—MUMDEAeLEwrvw•q) OR INSTALL VALVE AT I- (/) �j������G `�• 1B•MAXIMUM DEPTH(OPTIONAL) \ — DOUBLE CHECK VALVE ASSEMBLY PROPERTY LINE(1YPICAL 1. The FIRST fitting Inside of the building shall be a UL Oeted flanged LU c / 1B'MIN. OO 1rMW. FOR ALL RISER CONFIGURATIONS) American Flow Control,Kennady r Mueller OS&Y valve the same / Q0 I. ae the fire service One. CONFO 0"1ILA N[oM 2 NI Doubt.Check Valve Assemblies shall be: CO E=TCOINANFaIMTgNs.• a. UL or FM listed. rIIAI/ram TYPE 1 i SLOPE EXCEPT (NO STEEPER FA41elO SEWTN THAN 1:1 SLOPE IXLEPT FOR ROCKS OR WA1FR 111 CROSSINGS W���ERVICE b. a Coned by the LrolUni nlly��Leh Research ern r(USClo oFCCC R)for undation or T 4 ryr PROVIDE FLIXIBLE, Cross Connsc0on Control and TRENCH WI—D.OF PIPE PLUS 2fEET WATER-TIGHT CONNECTION /VI Not,a operation in the proz.ed position(vertical r horizontal)am shown ► VAl.L1AM R. •- MINIMUM TRENCH WIDTH-35 FEET FOR ALL WALL OR FLOOR an approved p!an.. TYPE'A•TRENCM BAGKFILL PIPE PENETRATIONS, e. Inetoiled as shown on the approved pkne. DREYER r` o 3B53 PE W� 3. A nor detection d.Ytce aMlt tea Installed immediately following the as TYPE•I-PIPE BEDDING p p p Double Chock Volvo Assembly(dorm check wive,flow senwr/alarm, ypp^Ac-le/•'�-�••� w� NorEs: meter,NeJ os Aown on tM opprovad plans.Peddle-type fbw �4T/'+L Till IMPORTE03WMINUSSELEm O E alamn not p.—Xted on dry eye—.. AR nil BEOaOIa YAIERyy.lylc90 O Oop�O 1.NO EXCEPTIONTOTHEMIN SEPARATON REDUIREMENT IS PERMITTED WHEN THE SEWAGE CARRYING PIPE IS A 4BLMOCK ,E r MA1bIN1M 1AyERyµO (��O�O Q�-p FDRCE MAIN AT CROSSINGS,ONE FULLIENGRI OF WATER MAIN PIPE SHALL BE LOCATEG 50 THAT BOTH JOINn WILL t1�GR 4. A Double Detxir Check Vdw Assembly may W sod with p standard THOPOUGHLY COMPACTED _�•+O_ /VSOO BE AS FAR FROM THE FORCE MAIN AS POSSIBLE E Dlty of Bozeman motor. The motor loop of the Double Dstector 0 0 Check Valve shall haw o Doubf*Check Volvo Assembly InetoRsd which O D CJW"' 2 IESSTHAN IB INCHES OF SEPARATON IS PERMITTED WHEN THE GRAVIY SEWER ATTHE CROSSING I3 MADE FROM rrle.♦0 the wme trstOGOgon Qi!IAa.p-lfiOd ab—In regafrsm°nt fY+'v TBEODWa WHERE �OO n ASINGLE 20 FOOT LENGTH OF AWWA PRESSURE PIPE AND THE CROSSING ANGLE IS APPROXIMATELY 90 DEGREES- number two. F► SPECIFIC MONTANA OEPARTM ENT OF ENVIRONMENTAL aUALITYAPPROVAL IS REQUIRED FOR AVERTICAL SEPARATON 5. Horizontal Inetsllatbns must be a minimum of 2'above the flnlehed Z RE OUIREDFORSOFTOR 4O O OF LESS THAN iB INCHES BETWEEN WATER MAIN AND SANITARY SEWER Moon UNSTABLE FOUNDATION. 3-4 IS A STANDARD LENGTH OF PIPE AS SUPPLIED BYA PIPE MANUFACTURER B. Tha ITro esrvin deer must M a minlmum of 2'.tear from arty outside wall,and a minimum of 1'Clear from arty Interior wall. ^ 4 AOEOIMTE STRUCNRAL SUPPORTFOR PIPES AT CROSSINGS SHALL BE PROVIDED, `Lf���;. 7. The IncomirpRn eervlm it"*hail be a nonimum B.Y,and a mox- TTH .{y• Imum of 7.5 below the IlWahed grade. 0 WTATER/S EWER SEPERATION CK S. All ng a r ce 175 line appurtenances shall have a minimum pressure j �1 LAL TYPICAL UTILITY TRENCH 9. Al flre service O 1 r lines 4'and larger shall be Clam 51 Ductile Iron Pipe. I _ NTS W D-1 DETAAL I 10.Use sizing: The Double Chock Valve Assembly shall be equal In elm Q NTS a-" to the outgoing pipe diameter(downstream). [--1' MIN., 2' MAX. LU 2' MIN., 3' MAX CLEWMCE W m 0- ABOVE FINISHED FLOOR n STANDARD FIRE SERVICE z w a otS e I11*00e3. `D-1 LINE INSTALLATION U> Zd NTS O Q H� w r y p a U aW �1 m�z �> l•.�•. :r• B :'r; Q to U a tLL 3 /\ ,A REDUCER MIN. UNDISTURBED EARTH LL SCALE: i"=20' v s — REVISIONS u• I 1.11.01-2013 1 2 a 4. TEE TEE (PLUGGED) BEND S 6. DIMENSIONS FOR THRUST BLOCKING 7. FITTING TEES&PLUGS 90'BEND 45'BEND&WVES REM221#'BEND ENGINEER: PSY SIZES A B A B A B A B DRAFTSMAN: BWD 1 3•A4 1-10• rs• r-1o• r-0• roc• 1=m roc• o'-0 l 6• 2-3' 1'-11• 2'1` 2 CHECKED BY:WRD'-0• 2'-0• 1••6• 1'-9• -0 M's 13 3'-0• 21-61 3'4i' 3'-2' 2'3' 2'-3' 2'-0' 1'-0' O810612013 10' 3'A' 3'3` 4'-4• 4'-0' T-3' 2'-10' 2'-5' 2'-0' rnolOrcnc eau 12` 4131 4'-0' 5'-1• 4'-lW 3•-TO' 1 3'-6' 1•9• 2'-0• fi 1 14' '-0' 4'-1` 6`-9- 5'-0' 5'-0' Y-F 3'-7"- 5 2'-T 16' 6'3- 4'-10' T3' 5'-9• 5.9- 4'-2' 4'-5- 2'0 Y oanA: �wmN° NOTE: ' THIS TABLE IS BASED ON 150 PSI MAIN PRESSURE AND 1500 PSF SOIL BEARING PRESSURE. ❑ D M D, e ONaM $/ ❑ No D a THRUST BLOCKBLOCK ` Dt DETAIL RECORD DRAWING 1 NTS JUNE 2014 F S 3 U