Loading...
HomeMy WebLinkAbout10-01-07_West Winds Planned Unit Development Phases 4-8 Sub_12 Commission Memorandum REPORT TO: Honorable Mayor and City Commission FROM: Lanette Windemaker, AICP, Contract Planner SUBJECT: West Winds PUD Phases 4-8 Major Subdivision, #P-07028 MEETING DATE: Monday, October 1, 2007 RECOMMENDATION: The City Commission approves application #P-07028 subject to the conditions of approval and code provisions outlined in the Staff Report, with Condition #14 as amended below. BACKGROUND: This is a preliminary plat application to subdivide ~ 85 acres into up to 220 single- and multi-household lots with an optional church lot, streets, park and open space areas. This request is for eight phases. The project will have access from Oak Street, Davis Lane, Baxter Lane, Hunters Way, North 27th Avenue, and internal streets. The property is legally described as a portion of the NW ¼, Section 2, T2S, R5E, PMM, City of Bozeman, Gallatin County, Montana, and is zoned R-3 (Residential Medium Density District). The remaining unsubdivided portion of the West Winds PUD project is generally located northeast of the intersection of Oak Street and Davis Lane. UNRESOLVED ISSUES: Fire Station Site. 14. Final plat approval for West Winds Phases 4-8 Major Subdivision shall not be granted until an appropriate fire station site within the area defined in the adopted Bozeman Fire Protection Master Plan (i.e., between Flanders Mill Road and North 27th Avenue, and between Durston Road and Baxter Lane) has been secured. Subdivider shall enter into an agreement with the Fire Department whereby the Subdivider shall plat and dedicate the park land with an easement, of an adequate size to be determined by the City Fire Department but not to exceed 1.5 acres, for the fire station site; design, construct, and warranty, the full design section of Hunters Way, Trade Wind Lane and Baxter Lane including temporary cul-de-sac(s) if needed, and the sewer and water main extensions adjacent to and along the frontages of the proposed fire station site, located at the intersection of Hunters Way and Baxter Lane in the West Winds Park. The main extensions shall include service stubs to the site as directed by the City Engineering Department. Infrastructure plans for the first of the remaining phases shall include these improvements. The subdivision dedication and extensions will be made upon receiving a written request from the City Fire Department. Subdivider shall be responsible for amendments to the approved PUD Final Plan and Park Master Plan to include the fire station site, and if needed, for an appraisal of the fair market value in accordance with Section 18.50.030, BMC. If the initial subdivision of West Winds Phases 4-8 Major Subdivision requires park land in excess of the total net park land dedicated less the acreage of the fire station site, then the City Fire Department shall be responsible for payment of cash-in-lieu of park land for site acreage over the 134 difference established by the West Wind Planned Unit Development Project Park Calculation – Revised 8/14/2007 between the Park Area Required Senior Living Option of 18.59 acres from the Total Net Park Land Provided. Based on the 8/14/2007 calculation of the Total Net Park Land Provided in Amended PUD at 19.563 acres, the City Fire Department cash-in-lieu of park land payment would be for fire station site acreage over 0.973 acres. FISCAL EFFECTS: Fiscal impacts are undetermined at this time, but will include increased property tax revenues from new development, along with increased costs to deliver municipal services to the property. ALTERNATIVES: As suggested by the City Commission. CONTACT: Please email Lanette Windemaker at lwindemaker@bozeman.net if you have any questions prior to the public hearing. APPROVED BY: Andrew Epple, Planning Director Chris Kukulski, City Manager 2 135 PLANNING DEPARTMENT STAFF REPORT WEST WINDS PUD PHASES 4-8 SUBDIVISION PRELIMINARY PLAT #P-07028 Item: Subdivision Preliminary Plat Application #P-07028, to subdivide ~ 85 acres as single-, multi-household lots with a church lot, streets, park and open space areas on property legally described as a portion of the NW ¼, Section 2, T2S, R5E, PMM, City of Bozeman, Gallatin County, Montana. Applicant/Owner: Cascade Development Inc. (John Dunlap), 1627 West Main St., Ste 223, Bozeman, MT 58715. Representative: HKM Engineering Inc. (Clint Litle), 920 Technology Blvd., Ste A, Bozeman, MT 59718. Date/Time: Before the Planning Board on Wednesday, September 5, 2007 at 7:00 p.m. in the Community Room, Gallatin County Courthouse, 311 West Main Street, Bozeman, Montana, and Before the City Commission on Monday, October 1, 2007 at 6:00 p.m., in the Community Room, Gallatin County Courthouse, 311 West Main Street, Bozeman, Montana. Report by: Lanette Windemaker, AICP: Contract Planner. Recommendation: Conditional Approval. PROJECT LOCATION The subject property is ~ 85 acres of land located northeast of the intersection of Oak Street and Davis Lane, is legally described as a portion of the NW 1/4, Section 2, T2S, R5E, PMM, City of Bozeman, Gallatin County, Montana. The property is zoned R-3 (Residential Medium Density District). Please refer to the vicinity map on the following page. 136 PROPOSAL The applicant is requesting Subdivision Preliminary Plat approval to subdivide ~ 85 acres into up to 220 single- and multi-household lots with a church lot, streets, park and open space areas. This request is for eight phases. The project will have access from Oak Street, Davis Lane, Baxter Lane, Hunters Way, North 27th Avenue, and internal streets. In conjunction with this subdivision preliminary plat, application has been made to modify the approved Conditional Use Permit (CUP) for the West Winds Planned Unit Development (PUD) Final Plan. The modification requested would eliminate townhouse lots, allow a church lot, and change the allowable height. About half of the original development has received final plat approval and is under construction. The applicant is requesting relaxation of standards in the Bozeman Municipal Code from the following: • Section 18.16.060, Building Height; to allow a maximum building height of 42 feet for a roof pitch equal to of greater than 5:12. BACKGROUND West Winds Subdivision Phase 1 was granted preliminary approval on May 24, 2004, with final approval on September 19, 2005, for the subdivision of 31 acres of the original 160 acre parcel, into 39 single-household, 38 townhouse and 3 multi-household lots. The City Commission approved the following relaxations with the original West Winds Planned Unit Development: a) Section 18.50.020 “Park Requirements” to allow the area requirement to be based on 11% net buildable area instead of 0.03 acres per dwelling unit for the affordable housing lots; b) Section 18.16.020.B “Authorized Uses” to allow assisted living/elderly care facilities and apartments within the “R-3” zoning district; c) Section 18.42.030.C “Double/Through and Reverse Frontage” to allow double frontage lots # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 2 of 21 137 adjacent to the arterial and collector streets; d) 18.42.040.B “Block Length” to allow the block lengths to exceed 400 feet; e) Section 18.42.040.C “Block Width” to allow the minimum block length to be less than 200 feet for the blocks with Restricted Size Lots; f) Section 18.42.180.C “Number of Restricted Size Lots Required” to allow the townhouse Restricted Size Lots to be less than 3,000 square feet and more than 3,000 for corner townhouse lots; and g) Section 18.44.090.D.3 “Spacing Standards for Drive Accesses” to allow residential lots that front on Hunter’s Way and Buckrake and back onto the linear park to access local streets within 150 feet of an intersection with an arterial street and to allow the proposed access separation distance between the proposed local streets onto Oak Street, an arterial street, to be separated less than 660 feet. The Final Park Plan was approved by the City Commission on May 16, 2005. On October 17, 2005, Phase 2 of the West Winds Subdivision was granted preliminary approval for the subdivision of 34 acres into 25 single-household, 86 townhouse lots and 1 multi-household (affordable) lot with final plat occurring on October 16, 2006. Phase 3 of the West Winds Subdivision was granted preliminary approval on July 24, 2006, to subdivide 12 acres into 9 single-household and 2 multi-household lots, and the final plat was approved on February 26, 2007. The necessary Preliminary Plat Supplements were submitted or waived by the Development Review Committee (DRC). ZONING DESIGNATION & LAND USES The subject property is zoned “R-3” (Residential Medium Density District). The intent of the “R-3”, Residential Medium Density District, is to provide for the development of one- to five-household residential structures near service facilities within the City. It should provide for a variety of housing types to serve the varied needs of households of different size, age and character, while reducing the adverse effect of nonresidential uses. The property is vacant. The following land uses and zoning are adjacent to the subject property: North: “R-3” (Residential Medium Density) – Baxter Square Subdivision. “R-1” (Residential Single-Household, Low Density District) – Baxter Lane Subdivision. “RS” (Residential Suburban) – Dwelling. “AS” (County Zoning Agricultural Suburban) – Unincorporated, agricultural, and dwellings. East: “R-3” (Residential Medium Density) – West Winds PUD Phases 1-3. South: “R-1” (Residential Single-Household, Low Density) – Harvest Creek Subdivision. “SRR” (County ZD#1, Semi Rural Residential) – Unincorporated. West: “R-3” (Residential Medium Density) – Baxter Meadows PUD Phase 4. “PLI” (Public Lands and Institutions) – Regional Park. ADOPTED GROWTH POLICY DESIGNATION The property is designated as “Residential” in the Bozeman 2020 Community Plan. The R-3 (Residential Medium Density District) zoning designation is consistent with this land use # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 3 of 21 138 designation of the property. Residential. This category designates places where the primary activity is urban density living quarters. Other uses which complement residences are also acceptable such as parks, low intensity home based occupations, fire stations, churches, and schools. The residential designation also indicates that it is expected that development will occur within municipal boundaries which may require annexation prior to development. The dwelling unit density expected within this classification varies. It is expected that areas of higher density housing would be likely to be located in proximity to commercial centers to facilitate the broadest range of feasible transportation options for the greatest number of individuals and support businesses within commercial centers. Low density areas should have an average minimum density of six units per net acre. Medium density areas should have an average minimum density of twelve units per net acre. High density areas should have an average minimum density of eighteen units per net acre. A variety of housing types should be blended to achieve the desired density with large areas of single type housing being discouraged. In limited instances the strong presence of constraints and natural features such as floodplains may cause an area to be designated for development at a lower density than normally expected within this classification. All residential housing should be arranged with consideration given to the existing character of adjacent development, any natural constraints such as steep slopes, and in a fashion which advances the overall goals of the Bozeman 2020 Community Plan. The residential designation is intended to provide the principal locations for additional housing within the Planning Area. PRELIMINARY PLAT SUPPLEMENTS The West Winds PUD Preliminary Plan for the entire development and the Phase 1 Preliminary Plat addressed all of the supplemental review criteria. Updates of the utility plans and traffic study were required for this application. A. Surface Water: Harmon Ditch, aka Cattail Creek, flows north-south through the park land located in the center of the West Winds PUD project, generally separating Phases 1 and 2 from Phases 3 thru 8. There is a 50 foot watercourse setback. All lots have been platted outside of the watercourse setback area. Any activity within the identified watercourse and/or wetlands area (i.e., road construction) will require all applicable permits (i.e., 310, 404, Turbidity exemption, etc.). B. Floodplains: The floodplain study for Harmon Ditch, aka Cattail Creek, was completed in December, 2004. C. Groundwater: Depth to groundwater was measured in different locations on the property on April 9, 2003, July 1, 2003 and February 4, 2004. The depth to groundwater was between 1.7 feet and 10.4 feet from the surface. As discussed in the report the fluctuations of groundwater depth are also due to the season, irrigation and land use. A note will be required on the final plat that due to high ground water conditions in the area full or partial basements are not recommended. Buildings proposed for construction with crawl spaces or basements shall include Engineer Certification regarding depth of # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 4 of 21 139 ground water and soil conditions and proposed mitigation methods to be submitted with each Building Permit. Installation of municipal water and sanitary sewer services will greatly reduce any concerns regarding the potential of groundwater degradation. D. Geology - Soils - Slopes: There are no known geologic hazards associated with this site, with exception to the Seismic Zone 3 for earthquakes, which is common for the Bozeman area. No significant physical features or topographical conditions have been identified, and no slopes in excess of fifteen percent (15%) grade are evident. Other than the need to dewater areas for utility installation there does not appear to be anything in the geotechnical report that indicates any geologic hazards. The Building Department will require a soils report for each lot prior to approving a building permit. E. Vegetation: The property has been historically used for agricultural purposes. Therefore, a majority of the existing vegetation is alfalfa, grasses and some noxious weeds. A Memorandum of Understanding for a weed control plan with the Weed District is required with the Final Plat. F. Wildlife: Due to the agricultural history of the property and limited mature vegetation in the area, any potential impacts to wildlife and wildlife habitat are limited to small mammals and ground nesting birds, but also larger mammals such as deer frequent the property. No known endangered species or critical game ranges have been identified in the area. The 50-foot watercourse setback along the existing watercourse will protect any riparian environment already established on the property. G. Historical Features: The State Historic Preservation Office required a cultural resource inventory which was conducted and submitted with the Final PUD Plan and the Final Plat for Phase 1. H. Agriculture: The adopted Growth Policy identifies this property as Residential. The City Commission approved the residential zoning on the property with the annexation. The zoning designations and adopted Growth Policy do not contemplate agricultural uses for this property. I. Agricultural Water User Facilities: The applicant must ensure that no agricultural water user facilities or neighboring agricultural uses will be impacted by this development. J. Water and Sewer: The Annexation Agreement for the property allowed a reserve capacity in the Main Mall sewer main for 960 dwelling units in return for allowing the main to be constructed across the undeveloped property. An extension of municipal water mains in the area will provide water for domestic and fire protection services. An extension of municipal sewage lines will provide for sewage collection and disposal. Final approval of the water distribution system and sewage collection and disposal system for this subdivision proposal will be obtained through the normal approval procedures of # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 5 of 21 140 preliminary and final plat review by the City Engineer’s Office, Superintendent of Water/Sewer, and Montana Department of Environmental Quality. K. Stormwater Management: Detention ponds located within the open space areas of the subdivision will provide stormwater management. The standard requirement for a Stormwater Master Plan applies to this project. The standard code requirements apply, including the requirements for plans and specifications, detailed design reports, and engineering services for construction inspection, post-construction certification and preparation of mylar record drawings applies. No building permits will be issued prior substantial completion and City acceptance of required stormwater infrastructure improvements. Stormwater improvements must be completed or financially guaranteed prior to final plat approval. L. Streets, Roads, and Alleys: Access: Access to the subdivision will be from Oak Street, Davis Lane, Baxter Lane, Hunters Way, and North 27th Avenue. Based on adequate access separation distances on the arterial streets, there is a one (1) foot wide “No Access” strip is required for all lots fronting onto Oak Street, Davis Lane and Baxter Lane. Capacity: Oak Street is designated as a Major Arterial, and both Baxter Lane and Davis Lane are designated as Minor Arterials. These streets will have to be improved to arterial standards. Traffic Generation: An updated detailed Traffic Impact Study for the entire West Winds Development has been provided to and reviewed by the City Engineer’s office. The Executive Summary of the update is included in Appendix 10 of the submittal, and the full study is available for review at the Planning Department. Based on the study this subdivision at build out will generate as many as 4,897 average weekday trips. Trails: There is a future trail corridor bisecting the West Winds PUD from the south side to the north side along the Harmon Ditch, aka Cattail Creek, stream corridor, and a second trail corridor bisecting the West Winds PUD from the east side to the west side in general alignment from Tschache Street to Vaquero Street. GVLT has recommended that the east-west greenway corridor be located on the south side of Winter Park. While this might reduce the number of street crossings to the Regional Park, for the foreseeable future it does not reduce the number of street crossings to the new Chief Joseph Middle School and in fact would end up on the side of Vaquero Street that does not have a sidewalk. Bicycle and Pedestrian Pathways, Lanes and Routes: According to Bike Route Network of the Greater Bozeman Area Transportation Plan (Figures 6-3 and 6-4) and the Recommended Street Standards of the Greater Bozeman Area Transportation Plan (Figures 11-3 and 11-4), bike and pedestrian facilities are required along Oak Street, Baxter Lane and Davis Lane. In addition, the bike route on Hunters Way will have to be continued. M. Utilities: No concerns were mentioned from any of the private agencies regarding the provision of service to the proposed subdivision. All utilities servicing the subdivision will be provided by underground services. All utility easements shall be noted on the final plat. # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 6 of 21 141 N. Educational Facilities: Bozeman School District #7 has previously indicated that the bus system will accommodate the additional students. O. Land Use: The growth policy designates the area as Residential. West Winds Phases 4-8 Subdivision contains up to 220 lots including single-household, townhouse, multi-household lots and a church lot. Both DRB and CAHAB have expressed concerns about the loss of the majority of townhouse lots resulting in a lack of diversity and affordability. Density: This project has an approved net density of ~ 9.8 dwelling units per acre with a maximum of 687 dwelling units not including congregate care. The modifications requested would put the net density of the project in a range of ~ 9.15 to ~ 10.08 dwelling units per acre. Based on the PUD performance points, for the provision of 69 affordable housing units, the density cap may be up to 690 dwelling units excluding the congregate care units (assisted living). In addition, there was a density cap of 687 dwelling units in the subdivision based on the park land dedication which would also exclude the congregate care units. RSLs: For affordable housing, the applicant has provided some detached single-household lots at 5,000 square feet in area which may be designated as Restricted Size Lots. The RSL requirements must be met for each phase of the subdivision. Any multi-household complexes will have to provide restricted dwelling units of 909 square feet in accordance with Section 18.42.180.C.5 of the Bozeman Municipal Code. The Community Affordable Housing Advisory Board had the following comments in support of affordable housing: a. Would prefer not to see a decrease in the number of units. b. Would prefer townhouses to condos. Condos are hard to sell as homes or resell as homes if the some of the units convert to rentals. c. For attached units having a FHA inspection will allow more types of affordable financing. Urge builders to have FHA inspect. d. Concerns were voiced about loss of connectivity with the Park due to re-routing of streets. Relaxations: The applicant has requested the following relaxation: Section 18.16.060, Building Height; to allow a maximum building height of 42 feet for a roof pitch equal to of greater than 5:12. This relaxation is addressed by PUD Preliminary Plan condition #1 which states “The relaxation of Section 18.16.060, Building Height; to allow a maximum building height of 42 feet for a roof pitch equal to or greater than 5:12 shall be restricted to /multi-household apartment type dwellings. All projects utilizing this relaxation are subject to site plan review under Chapter 18.34, BMC.” Building Permits: The applicant has indicated a desire to submit a Concurrent Construction Plan under Section 18.74.030.D. A Concurrent Construction Plan that addresses all aspects of this section to the Planning Department for DRC review and Planning Director approval before concurrent construction may be approved. Unless such plan is approved and executed, building permits will not # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 7 of 21 142 be issued for any lot in this subdivision until all required on and off-site improvements are completed and accepted by the City of Bozeman. P. Parks and Recreation Facilities: The developer was granted a PUD relaxation that was reviewed concurrently with West Winds Phase 1 Subdivision to allow the park area requirement to be based on 11% net buildable area instead of 0.03 acres per dwelling unit for the affordable housing lot. The property owner also agreed to a density cap or the option to provide additional parkland or cash in lieu of parkland for future increases to the overall density. Since the dedicated park cannot include the east-west transportation trail, watercourse, wetlands and associated setback and since the Home Owners Association is required to maintain those areas in perpetuity the final plats will need to differentiate between the public Common Open Space with a public access easement from the dedicated parkland. The final park plan was approved on May 16, 2005. The park plan will need to be amended before any additional phases are granted final plat approval. Q. Neighborhood Center Plan: The park is the neighborhood center for this subdivision. It is located within 600 feet of the geographic center of the subdivision. R. Lighting Plan. The amended lighting plan in found in Appendix 9, and is subject to final review and approval. A Special Improvement Lighting District is intended to be formed for the subdivision street lighting. S. Miscellaneous: West Winds was approved as a Planned Unit Development and therefore must comply with the approved final PUD Plan, development guidelines and all conditions of approval for the Conditional Use Permit. The proposed subdivision is adjacent to the regional park on the west. However, no direct impacts to the regional park, or other public lands, have been identified with this subdivision proposal. On or near the subdivision, there is no known health, safety hazards or other nuisances, such as unpleasant odors, unusual noise, dust or smoke, with exception to the typical risks identified with seismic activity and the effect on the local fire service area discussed below. STAFF FINDINGS/REVIEW CRITERIA The basis for the City Commission’s decision to approve, conditionally approve, or disapprove the subdivision shall be whether the preliminary plat, public hearing if required, Planning Board advice and recommendation, and additional information demonstrates that development of the subdivision complies with this title, the City’s growth policy, the Montana Subdivision and Platting Act, and other adopted state and local ordinances, including, but not limited to, applicable zoning requirements. The Montana Subdivision and Platting Act, Section 76-3-608, establishes the following primary review criteria for the governing body to consider when evaluating subdivisions. Planning Staff, the DRC, the WRB, the R&PAB Subdivision Review Committee and other # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 8 of 21 143 reviewing agencies have made comments in relation to those and other criteria as described below, and have recommended conditions as outlined at the end of this Staff Report. A. Effects on agriculture, agricultural water user facilities, local services, the natural environment, wildlife and the wildlife habitat, and public health and safety. 1. Effects on Agriculture. The property is annexed, and has been zoned and master planned for residential development for many years. 2. Effects on Agricultural Water User Facilities. The applicant must ensure that agricultural water levels will be maintained. In addition, the Montana Fish, Wildlife and Parks, NRCS, Montana Department of Environmental Quality, and Army Corps of Engineer's must be contacted regarding the proposed project and any required permits (i.e., 310, 404, Turbidity exemption, etc.) shall be obtained prior to final plat approval. 3. Effects on Local Services. Water/Sewer: The standard code requirements apply, including the requirements for plans and specifications, detailed design reports, and engineering services for construction inspection, post-construction certification and preparation of mylar record drawings applies. No building permits will be issued prior substantial completion and City acceptance of required water and sewer infrastructure improvements, unless otherwise permitted under the BMC. Water and sewer main extensions must be completed or financially guaranteed prior to final plat approval. The City needs to acquire water rights to keep up with the growing demand for municipal water service. In keeping with the City’s annexation policy, water rights or cash-in-lieu must be paid prior to final plat approval. Police/Fire: The property is within the City’s Police and Fire emergency response area. The subdivider must obtain addresses for the new lots from the City Engineering Division prior to filing of the final plat to facilitate fire and police response to the site. In November 2006, the City Commission adopted the Bozeman Fire Protection Master Plan. The Fire Master Plan identified current and future service delivery deficiencies and outlined timetables for future facilities and staffing to address the growing community. The plan strongly identified the immediate need for an additional fire station in the northwest quadrant of the city (between Flanders Mill and 27th and between Durston and Baxter). To this end, the Fire Department has chosen an architect, added additional firefighting personnel and is actively pursuing long term funding for personnel and equipment. We have, however, been unable to find a suitable location for Fire Station 3. West Winds Subdivision Phases 4-8 is central in the service area of the new fire station and is outside of the service area of the City’s existing fire stations. Until such a time as we are able to secure an appropriate fire station site within the area defined in the Master Plan, we are unable to approve any additional development in this area. Accordingly, we request that the following condition of # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 9 of 21 144 preliminary plat approval be applied to West Winds Subdivision Phases 4-8: Plat #14. Final plat approval for West Winds Phases 4-8 shall not be granted, nor shall any preconstruction meetings be held or construction of any subdivision-related infrastructure commence, until an appropriate fire station site within the area defined in the Master Plan (i.e., between Flanders Mill Road and North 27th Avenue, and between Durston Road and Baxter Lane) has been secured. Streets: Access to the subdivision will be from Oak Street, Baxter Lane, Davis Lane, Hunters Way, North 27th Avenue and proposed interior streets. The standard code requirements apply, including the requirements for plans and specifications, detailed design reports, and engineering services for construction inspection, post-construction certification and preparation of mylar record drawings applies. No building permits will be issued prior substantial completion and City acceptance of required street infrastructure improvements, unless otherwise permitted under the BMC. Street improvements, including lighting, must be completed or financially guaranteed prior to final plat approval. Stormwater Management: The standard requirement for a Stormwater Master Plan applies to this project. The standard code requirements apply, including the requirements for plans and specifications, detailed design reports, and engineering services for construction inspection, post-construction certification and preparation of mylar record drawings applies. No building permits will be issued prior substantial completion and City acceptance of required stormwater infrastructure improvements, unless otherwise permitted under the BMC. Stormwater improvements must be completed or financially guaranteed prior to final plat approval. 4. Effects on the Natural Environment. Applicant has entered into an agreement for a Noxious Weed Management and Revegetation Plan with the Gallatin County Weed Board. A Memorandum of Understanding must be entered into with the County Weed Board prior to submittal of the final plat. Based on the geotechnical information provided, staff is recommending that the following note shall be included on the final plat: “Buildings proposed for construction with crawl spaces or basements shall include Engineer Certification regarding depth of ground water and soil conditions and proposed mitigation methods to be submitted with each Building Permit. The Final Plat shall include a notation that due to high ground water conditions full or partial basements are not recommended.” 5. Effects on Wildlife and Wildlife Habitat. Due to its historical uses and the development of surrounding lands, no significant adverse effects on wildlife or their habitat have been identified on the property. 6. Effects on Public Health and Safety. Because municipal sewer will service future development in the subdivision, the threat of groundwater degradation from onsite sewage disposal will be eliminated. There are no known, unmitigated natural or man-made hazards on this property. The intent of the regulations in the Bozeman Municipal Code is to protect the public health, safety and # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 10 of 21 145 general welfare. The subdivision has been reviewed and determined to be in general compliance with the title. Any other conditions deemed necessary to ensure compliance have been noted throughout this staff report. B. Compliance with the following: 1. The survey requirements provided for in Part 4 of the Montana Subdivision and Platting Act. The subdivision complies or will comply with survey requirements of the Montana Subdivision and Platting Act and was filed as a preliminary plat in accordance with the state statute and the Bozeman Municipal Code. 2. The local subdivision regulations provided for in Part 5 of the Montana Subdivision and Platting Act. The final plat shall comply with the standards identified and referenced in the Bozeman Municipal Code. The applicant is advised that unmet code provisions, or code provisions that are not specifically listed as conditions of approval, does not, in any way, create a waiver or other relaxation of the lawful requirements of the Bozeman Municipal Code or state law. The following requirements are standards of the Bozeman Municipal Code and shall be addressed on the final plat: a. Pursuant to Section 18.42.040, a right-of-way for a pedestrian walk, not less than 10 feet wide, shall be required to ensure that no blocks exceed 600 feet. Unless the pedestrian right-of-way is a minimum of 30 feet wide, the setback adjacent to it shall be a minimum of 15 feet. These rights-of-way and a note shall be on the final plat denoting specific locations, subject to review and approval of the Planning Department. b. Pursuant to Section 18.42.060, front yard utility easements shall be 10 feet wide, and shall always be provided unless written confirmation is submitted to the Planning Department from ALL utility companies providing service indicating that front yard easements are not needed. c. Pursuant to Section 18.42.150, street lighting, including pathway intersection lighting, shall be provided. d. Section 18.42.180 requires 10% of the net buildable area to be devoted towards Restricted Size Lots. The Final Plat shall indicate which lots are reserved to meet the RSL requirement. The RSL designation shall be recorded on the individual lots in a manner that will appear on a title search and include reference to the sunset provisions of Section 18.42.180. Notes describing RSLs shall indicate the correct section of the code. e. Per Section 18.50.090, executed waivers of right to protest creation of special improvement districts (SIDs) for a park maintenance district shall be filed and of record with the Gallatin County Clerk and Recorder prior to final plat approval. A copy of the filed documents shall be submitted with the final plan. # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 11 of 21 146 f. Covenants, restrictions, and articles of incorporation for the creation of a homeowners’ association shall be submitted with the final plat application for review and approval by the Planning Office and shall contain, but not be limited to, provisions for assessment, maintenance, repair and upkeep of common open space areas, public parkland/open space corridors, stormwater facilities, public pathway/trails, snow removal, and other areas common to the association pursuant to Chapter 18.72 of the Bozeman Municipal Code. g. Prior to final plan approval, a common area and facility maintenance plan and guarantee shall be provided for the permanent care and maintenance of open spaces, recreational areas, stormwater facilities and parking lots in accordance with Chapter 18.72 or the Bozeman Municipal Code. The same shall be submitted to the city attorney and shall not be accepted by the city until approved as to legal form and effect. A draft of these documents must be submitted for review and approval by the Planning Department at least 30 days prior to filing and recordation with the Gallatin County Clerk and Recorder. h. Section 18.78.070.D requires a Final Park Plan to be approved by the City Commission, with a recommendation from the Bozeman Recreation and Parks Advisory Board, prior to Final Plat approval. Four bound copies of the plan shall be submitted to the Planning Office for review prior to installation of any improvements or prior to Final Plat submission, whichever comes first. The Park Plan shall address all of the criteria outlined in Section 18.78.060.P. i. The Final Plat shall conform to all requirements of the Bozeman Municipal Code and the Uniform Standards for Final Subdivision Plats and shall be accompanied by all required documents, including certification from the City Engineer that as-built drawings for public improvements were received, a platting certificate, and all required and corrected certificates. The Final Plat application shall include four (4) signed reproducible copies on a 3 mil or heavier stable base polyester film (or equivalent); two (2) digital copies; one (1) PDF copy; and five (5) paper prints. j. Pursuant to Section 18.06.040.D.6, conditional approval of the Preliminary Plat shall be in force for not more than one calendar year for minor subdivisions, two years for single- phased major subdivisions and three years for multi-phased major subdivisions. Prior to that expiration date, the subdivider may submit a letter of request for the extension of the period to the Planning Director for the City Commission’s consideration. The City Commission may, at the written request of the subdivider, extend its approval for no more than one calendar year, except that the City Commission may extend its approval for a period of more than one year if that approval period is included as a specific condition of a written subdivision improvements agreement between the City Commission and the subdivider, provided for in §18.74.060, BMC. k. If it is the subdivider’s intent to file the plat prior to installation, certification, and acceptance of all required improvements by the City of Bozeman, an Improvements Agreement shall be entered into with the City of Bozeman guaranteeing the completion # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 12 of 21 147 of all improvements in accordance with the Preliminary Plat submittal information and conditions of approval. If the Final Plat is filed prior to the installation of all improvements, the subdivider shall supply the City of Bozeman with an acceptable method of security equal to 150% of the cost of the remaining improvements. l. The applicant shall submit with the application for Final Plat review and approval, a written narrative stating how each of the conditions of preliminary plat approval has been satisfactorily addressed, and shall include a digital copy (pdf) of the entire Final Plat submittal. This narrative shall in sufficient detail to direct the reviewer to the appropriate plat, plan, sheet, note, covenant, etc. in the submittal. 3. The local subdivision review procedure provided for in Part 6 of the Montana Subdivision and Platting Act. A preliminary plat application was submitted on May 7, 2007. The letter of extension of Section 18.06.040, BMC was received on May 25, 2007. The required acceptability letter was sent on June 20, 2007. The preliminary plat was reviewed by the DRC on June 27, July 11 and 18, 2007. The required adequacy letter was mailed on August 3, 2007. On August 15, 2007, the fourth and final week of DRC review, a conditional recommendation was forwarded for consideration by the Planning Board and City Commission. The hearings before the Planning Board and the City Commission have been properly noticed, as required in the Bozeman Municipal Code. Public notice for this application was placed in the Bozeman Daily Chronicle on Sunday, August 19 and 26, 2007. The site was posted with a public notice on August 17, 2007. Finally, notice was sent to adjacent property owners via certified mail, and to other property owners of record within 200 feet of the subject property via first class mail, on August 17, 2007. The subdivision staff report was drafted and forwarded with a recommendation of conditional approval to the Planning Board for consideration at its September 5, 2007, public hearing. The City Commission will make a final decision at the October 1, 2007 public hearing. A final decision for a major subdivision from a tract of record must be made within 60 working days of the date it was deemed adequate or in this case by October 30, 2007. C. The provision of easements for the location and installation of any planned utilities. All utilities and necessary utility easements will be provided and depicted on the final plat. Pursuant to Section 18.42.060, front yard utility easements shall be 10 feet wide, and shall always be provided unless written confirmation is submitted to the Planning Department from ALL utility companies providing service indicating that front yard easements are not needed. D. The provision of legal and physical access to each parcel within the subdivision and the required notation of that access on the applicable plat and any instrument of transfer concerning the parcel. All lots within the subdivision will have direct access from dedicated public streets. # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 13 of 21 148 PUBLIC COMMENT No public comment has been received to date. Any public comments received after the date of this report will be distributed at the public hearing. RECOMMENDED CONDITIONS OF APPROVAL 1. With a proposed block length of ~ 1,080 feet from Breeze Lane to Tschache Lane, the street pattern in West Winds shall be designed to provide a city standard street connection to a full access intersection at Vaquero Street and Davis Lane, subject to Engineering and Planning Department review and approval. 2. With a proposed block length of ~ 975 feet from Oak Street to Vaquero Street, the street pattern in West Winds shall be designed to provide a street connection of Breeze Lane extended to a partial access intersection at Davis Lane, final location subject to Engineering and Planning Department review and approval. 3. Due to topography, the presence of critical lands, access control, and adjacency to open space, block lengths may exceed 400 feet but may not exceed 1, 087 feet. Block lengths shall not exceed 600 feet without a public right of way with pedestrian walkway. 4. Due to separation of residential development from traffic arterials and to overcome specific disadvantages of topography and orientation, block widths may be less than 200 feet or more than 400 feet in width. Block widths shall not exceed 600 feet without a public right of way with pedestrian walkway. 5. The remainder of the original tract of record (and of each phase of the subdivision)) shall be platted as an undevelopable lot in accordance with §18.74.080.B.6, BMC, with the following language placed on each undevelopable lot of the final plat “Lot development subject to further subdivision review.” No public improvements shall be required for the undevelopable lot until it is subdivided as a lot which is not subject to this restriction. The following language shall either be placed on the face of the plat or in a separate executed document to be recorded with the final plat. NOTICE IS HEREBY GIVEN to all potential purchasers of Lot X, of XXXXX Subdivision, City of Bozeman, Gallatin County, Montana, that the final plat of the subdivision was approved by the Bozeman City Commission without completion of on and off-site improvements required under the Bozeman Municipal Code, as is allowed in Chapter 18.74 of the Bozeman Municipal Code. As such, this Restriction is filed with the final plat that stipulates that any use of this lot is subject to further subdivision, and no development of this lot shall occur until all on and off- site improvements are completed as required under the Bozeman Municipal Code. THEREFORE, BE ADVISED, that Building Permits will not be issued for Lot of XXXXX Subdivision, City of Bozeman, Gallatin County, Montana until all required on and off-site # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 14 of 21 149 improvements are completed and accepted by the City of Bozeman. No building or structure requiring water or sewer facilities shall be utilized on this lot until this restriction is lifted. This restriction runs with the land and is revocable only by further subdivision or the written consent of the City of Bozeman.” 6. The approved park master plan shall be amended to address any additions, revisions or changes from the previous approval as well as the relocation of the trail corridor, locations of sewer mains, stormwater facilities and all easements, and shall be approved by the Park and Recreation Superintendent, prior to Final Plat approval. In addition, the park master plan shall document the current status of the park areas, phasing and number of dwelling units. 7. The covenants shall address street trees, and shall include a planting note stating that the planting hole shall be at least twice the diameter of the root ball, that the root flare of the newly planted tree is visible and above ground, and there should be a mulch ring 3’ -4’ in diameter around each newly planted boulevard tree. 8. Note 6 on Phase 6 shall be removed or corrected – a church is not limited commercial, it is a community center. 9. All subdivision final plats shall comply with the final approved PUD plan and Development Guidelines for the West Winds Planned Unit Development. 10. A note shall be included on the plat for all multi family lots describing park dedication allowances; e.g. park dedication requirements for Lot 12, Block 7 have been met for 48 dwelling units, at the time of subsequent development, when net residential density becomes known, cash- in-lieu of park dedication requirements shall be met by the property owner for any additional density in accordance with the BMC. This note shall be recorded on the individual lots in a manner that will appear on a title search. 11. The park shall be titled “Public Park”. The open space shall be titled “Open Space, Public Access”. Notes shall be included on the plat describing ownership and maintenance responsibility for all parks, open space and/or other common facilities and areas, e.g.: public park, dedicated to the city and maintained by the property owners association; and open space, public access, owned by the property owners, maintained by the property owners association, etc. Park land, open space areas and storm water facilities shall not be titled as lots or tracts but shall be numbered. 12. Street lighting, including pathway intersection lighting, shall be installed by the subdivider. Light locations and specifications shall be provided to the City Engineer for review and approval with the public improvements plans and specifications. All street light poles shall be installed a minimum of 10’ from any water or sewer main or appurtenance. 13. Street lighting SILD information for operation and/or maintenance shall be submitted to the Clerk of Commission directly after Preliminary Plat approval in hard copy and digital form. The final plat will not be deemed complete until the resolution to create the SILD has been approved by the City Commission. # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 15 of 21 150 14. Final plat approval for West Winds Phases 4-8 shall not be granted, nor shall any preconstruction meetings be held or construction of any subdivision-related infrastructure commence, until an appropriate fire station site within the area defined in the Master Plan (i.e., between Flanders Mill Road and North 27th Avenue, and between Durston Road and Baxter Lane) has been secured. 15. Water rights, or if water rights are not available cash-in-lieu thereof, as calculated by the City Engineer, is due with the final plat. 16. Buildings proposed for construction with crawl spaces or basements shall include Engineer Certification regarding depth of ground water and soil conditions and proposed mitigation methods to be submitted with each Building Permit. The Final Plat shall include a notation that due to high ground water conditions full or partial basements are not recommended. 17. Applicant shall provide a soils report, along with building plans, to the Building Division, recommending types of foundations. If development shall occur in phases, the soils report may address those lots within the proposed phase. 18. All plans and specification shall comply with the current version (including all addenda) of the City of Bozeman Design Standards and Specifications Policy and the City of Bozeman Modifications To Montana Public Works Standard Specifications Fifth Edition that have been adopted at the time of approval of the plans and specifications. 19. The final plat shall comply with the standards identified and referenced in the Bozeman Municipal Code. The applicant is advised that unmet code provisions, or code provisions that are not specifically listed as conditions of approval, does not, in any way, create a waiver or other relaxation of the lawful requirements of the Bozeman Municipal Code or state law. 20. To support the affordability of housing: a. To ensure a mix of housing types in Phases 4 to 8, the area south of Winter Park Street, in Phases 4-8, shall include multi family housing; townhouses and/or living/elderly care facilities and apartments. b. The minimum density of the West Winds PUD shall not be less than six dwelling units per acre. c. The number of townhouse lots may be increased at the time of final plat to comply with any increase in the number of townhouse lots on the approved final PUD plan. d. Townhouses are preferable to condos. Condos are hard to sell as homes or resell as homes if some of the units convert to rentals. e. Builders of attached units shall have a FHA inspection to allow for more types of affordable financing. f. Encourage connectivity with the Park. 21. Stormwater Master Plan: # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 16 of 21 151 A Stormwater Master Plan for these phases of the subdivision for a system designed to remove solids, silt, oils, grease and other pollutants from the runoff from the private and public streets and all lots must be provided to and approved by the City Engineer. The master plan must depict the maximum sized detention/retention basin location, show location of and provide easements for adequate drainage ways within the subdivision to transport runoff to the stormwater receiving channel. The plan shall include sufficient site grading and elevation information (particularly for the basin sites, drainage ways and finished lot grades), typical stormwater detention/retention basin and discharge structure details, basin sizing calculations and a stormwater maintenance plan. Any stormwater ponds located within a park or open space shall be designed and constructed to be conducive to the normal use and maintenance of the open space. Stormwater ponds for runoff generated by the subdivision (e.g., general lot runoff, public or private streets, common open space, parks, etc.) shall not be located in easements within privately owned lots. While the runoff from the individual lots will be dependent on the intensity of use on each lot, the maximum sizing of the storm retention facilities for each lot will be established based on maximum site development. Final facility sizing may be reviewed and reduced during design review of the FSP for each lot. 22. Plans and specifications and a detailed design report for water and sewer main extensions, streets and storm drainage facilities, prepared by a Professional Engineer (PE) registered in the state of Montana, shall be provided to and approved by the City Engineer. Water and sewer plans shall also be approved by the Montana Department of Environmental Quality. The Applicant shall also provide Professional Engineering services for Construction Inspection, Post-construction Certification, and preparation of mylar Record Drawings. Construction shall not be initiated on the public infrastructure improvements until the plans and specifications have been approved and a pre-construction conference has been conducted. All plans and specification shall comply with the current version (including all addenda) of the City of Bozeman Design Standards and Specifications Policy and the City of Bozeman Modifications to Montana Public Works Standard Specifications Fifth Edition that have been adopted at the time of approval of the plans and specifications. No building permits shall be issued prior to substantial completion and City acceptance of the required infrastructure improvements unless all of the requirements of Section 18.74.030.D of the Bozeman Municipal Code are met to allow for concurrent construction. 23. All infrastructure improvements including 1) water and sewer main extensions, and 2) public streets, curb/gutter, sidewalks fronting parks, open space, rear yard frontages or other non-lot frontages, and related storm drainage infrastructure improvements shall be financially guaranteed or constructed prior to Final Plat approval. City standard residential sidewalks shall be constructed on all public street frontages of a property prior to occupancy of any structure on the property. Upon the third anniversary of the # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 17 of 21 152 plat recordation of any phase of the subdivision, any lot owner who has not constructed said sidewalk shall, without further notice, construct within 30 days said sidewalk for their lot(s), regardless of whether other improvements have been made upon the lot. This condition shall be included on the final plat for the subdivision. 24. Project phasing shall be clearly defined including installation of infrastructure. 25. All proposed private utilities to serve the subdivision shall be shown on the public infrastructure plans and specifications. 26. The location of and distinction between existing and proposed sewer and water mains and all easements shall be clearly and accurately depicted on the plans, as well as all nearby fire hydrants and proposed fire hydrants. 27. Any easements needed for the water and sewer main extensions shall be a minimum of 30 feet in width with the utility located in the center of the easement. In no case shall the utility be less than 10 feet from the edge of the easement. All necessary easements shall be provided prior to final plat approval and shall be shown on the plat. Wherever water and/or sewer mains are not located under or accessed from improved streets, a 12 foot wide all weather access drive shall be constructed above the utilities to provide necessary access. 28. Street names must be approved by the Gallatin County GIS office and City Engineering office prior to final plat approval. 29. The developer shall make arrangements with the City Engineer's office to provide addresses for all individual lots in the subdivision prior to filing of the final plat. 30. The location of mailboxes shall be coordinated with the City Engineering Department prior to their installation. 31. The Montana Department of Fish, Wildlife and Parks, SCS, Montana Department of Environmental Quality and Army Corps of Engineer's shall be contacted regarding the proposed project and any required permits (i.e., 310, 404, Turbidity exemption, etc.) shall be obtained prior to plan and specification approval. 32. If construction activities related to the project result in the disturbance of more than 1 acre of natural ground, an erosion/sediment control plan may be required. The Montana Department of Environmental Quality may need to be contacted by the Applicant to determine if a Stormwater Discharge Permit is necessary. If a permit is required by the State, the Developer shall demonstrate to the City full permit compliance. 33. The applicant shall submit a construction route map dictating how materials and heavy equipment will travel to and from the site in accordance with Section 18.74.020.A.1 of the Bozeman Municipal Code. This shall be submitted as part of the final site plan for site developments, or with the infrastructure plans for subdivisions. It shall be the responsibility of the applicant to ensure that the construction traffic follows the approved routes. # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 18 of 21 153 34. All construction activities shall comply with Section 18.74.020.A.2 of the Bozeman Municipal Code. This shall include routine cleaning/sweeping of material that is dragged to adjacent streets. The City may require a guarantee as allowed for under this section at any time during the construction to ensure any damages or cleaning that are required are complete. The developer shall be responsible to reimburse the City for all costs associated with the work if it becomes necessary for the City to correct any problems that are identified. 35. Ditch relocation: a. The Montana Fish, Wildlife and Parks shall be contacted by the Applicant regarding the proposed relocation and any required permits (i.e., 310, 404, Turbidity exemption, etc.) shall be obtained prior to FSP approval. b. The Applicant shall comply with all parts of section 18.42.060.D for any ditch relocation. 36. In locations where Baxter Lane and Davis Lane are being improved, the various irrigation ditches and/or streams shall be either relocated outside the right-of-way, accommodated in an approved center median, or placed in a pipe. The plan for the irrigation ditches shall be reviewed and approved by the ditch owner. 37. Stormwater generated by the proposed subdivision shall not be discharged to an irrigation facility. 38. Any public street rights of way for which easements have been provided (i.e. Oak Street) shall be dedicated to the City on the Final Plat for this subdivision. The applicant shall also dedicate an additional 5 ft for the south half of Baxter Lane. 39. City standard curb, gutter and sidewalk shall be provided along all streets in the subdivision. 6 foot wide sidewalk will be required in the standard location on the development’s side of West Oak Street, Davis Lane, and Baxter Lane. 40. All typical street sections, including sidewalk location within the right-of-way and provisions for bicyclists shall be in conformance with the street standards recommended in the Greater Bozeman Area Transportation Plan, 2001 Update, unless otherwise approved by the City Commission, or by the City Engineer through the plan and specification review and approval process. 41. A schematic signage plan for the subdivision, noting any proposed traffic calming measures, shall be provided with the design report for review and approval by the City Engineer. 42. Parking will not be allowed on West Oak Street, Baxter Lane, or Davis Lane. 43. If approved for concurrent construction, detailed review and approval of the concurrent construction plans will be part of the infrastructure plan and specification review process. Building permits may not be issued until the plans are approved. # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 19 of 21 154 44. A 1 foot no access easement shall be shown on the final plat along the entire frontage of West Oak Street, Baxter Lane, and Davis Lane. 45. The Traffic Impact Study, 2007 Update, indicates that the North 27th Avenue intersections with West Oak Street and Durston Road will have level of service (LOS) at D or below prior to final build-out of the subdivision. Bozeman Municipal Code section 18.44.060.D states “All arterial and collector streets, and movements on intersection approach legs designated as arterial or collector streets, shall operate at a minimum level of service C.” The improvements necessary for each phase to raise the level of service at these intersections to Level of Service C must be installed and accepted by the City of Bozeman prior to the issuance of building permits, unless approved for concurrent construction. To determine the timing of the improvements, an update to the Traffic Impact Study shall be provided with the design report for each phase. Also, the update shall identify when the exclusive westbound left turn lane at West Oak Street and N 27th Avenue shall be installed. 46. Baxter Lane and Davis Lane, along the property boundary, shall be improved, as part of this development; to one half of a minor arterial standard as shown in the Greater Bozeman Area Transportation Plan 2001 Update and shall match the sections built by Baxter Meadows. Where one half of a standard arterial is being built 12 feet of pavement for the opposing lane of travel shall be provided. City standard curb and gutter, and 6 foot wide sidewalk will be required in the standard location on the development’s side of the street. Detailed review of the street and intersection design, and approval by the City Engineer will be required as part of the infrastructure plan and specification review process. 47. The east half of Davis Lane from West Oak Street to Baxter Lane must be constructed and accepted by the City prior to filing the Final Plat for any phase along Davis Lane, or financially guaranteed and completed prior to issuance of building permits, unless approved for concurrent construction. The design of Davis Lane is also to address the existing irrigation ditch and provide a median. The south half of Baxter Lane, from Buckrake Avenue to Davis Lane must be constructed and accepted by the City prior to filing the Final Plat for any phase along Baxter Lane, or financially guaranteed and completed prior to issuance of building permits, unless approved for concurrent construction. The infrastructure improvements shall include improvements to the intersections of Davis Lane at Baxter Lane and West Oak Street. 48. Each phase of the subdivision shall have a second means access. 49. Per the access standards in Section 090.D.3 of Chapter 18.44 of the Bozeman Municipal Code, the intersections of Windward Ave at Baxter Lane and Breeze Lane at Davis Lane will be partial access. 50. Ensure the sanitary sewer manhole spacing provided does not exceed the maximum manhole spacing, per the COB Design Standards and Specifications Policy. 51. Each phase of the subdivision shall have a minimum of two separate water main feeds. Single source loops created by phasing will not be allowed. # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 20 of 21 155 52. Hunters Way (from Baxter Lane to Oak Street) shall include a Signed Bike Route since this will be an extension of an existing Signed Bike Route on Hunters Way. CONCLUSION / RECOMMENDATION Pursuant to Section 18.06.040.D of the Bozeman Municipal Code, the Planning Board shall review the preliminary plat and supplementary information to determine if the proposed plat is in compliance or noncompliance with the adopted Growth Policy. The Planning Board shall act to recommend approval, conditional approval or denial of the preliminary plat application. The Board shall then provide advice and comments to the Bozeman City Commission for its consideration at its Monday, October 1, 2007, hearing which begins at 6:00 p.m. The Planning Board Resolution #P- 07028 and minutes from the Planning Board’s September 5, 2007, meeting will be forwarded to the City Commission and made a part of the Commission’s record. BECAUSE THIS APPLICATION IS FOR A MAJOR SUBDIVISION, THE BOZEMAN PLANNING BOARD WILL MAKE A RECOMMENDATION TO THE BOZEMAN CITY COMMISSION. THE CITY COMMISSION SHALL MAKE THE FINAL DECISION ON THIS APPLICATION. THE DECISION OF THE CITY COMMISSION MAY BE APPEALED BY AN AGGRIEVED PERSON AS SET FORTH IN CHAPTER 18.66 OF THE BOZEMAN MUNICIPAL CODE. Cc: Cascade Development Inc., 1627 West Main Street, #223, Bozeman, MT 59715 HKM Engineering Inc., 920 Technology Blvd., Ste A, Bozeman, MT 59718 # P-07028 West Winds PUD Phases 4-8 Subdivision Preliminary Plat: Staff Report 21 of 21 156 West Winds PUD Phases 4-8 Subdivision Preliminary Plat # P07028 1 of 10 RESOLUTION #P-07028 RESOLUTION OF THE CITY OF BOZEMAN PLANNING BOARD RECOMMENDING CONDITIONAL APPROVAL OF A SUBDIVISION PRELIMINARY PLAT APPLICATION ON ~ 85 ACRES TO BE SUBDIVIDED INTO AS MANY AS 220 SINGLE- AND MULTI- HOUSEHOLD LOTS WITH AN OPTIONAL CHURCH LOT, STREETS, PARK AND OPEN SPACE AREAS. THE PROPERTY IS ZONED R-3 (RESIDENTIAL MEDIUM DENSITY DISTRICT), AND IS GENERALLY LOCATED EAST OF DAVIS LANE AND NORTH OF OAK STREET. THE PROPERTY IS LEGALLY DESCRIBED AS A PORTION OF THE NW ¼, SECTION 2, T2S, R5E, PMM, CITY OF BOZEMAN, GALLATIN COUNTY, MONTANA. WHEREAS, the City of Bozeman has adopted a Growth Policy pursuant to 76-1-601, M.C.A.; and WHEREAS, the City of Bozeman Planning Board has been created by Resolution of the Bozeman City Commission as provided for in Title 76-1-101, M.C.A.; and WHEREAS, the applicant/owner, Cascade Development Inc. (John Dunlap), 1627 West Main St., Ste 223, Bozeman, MT 58715; represented by HKM Engineering Inc. (Clint Litle), 920 Technology Blvd., Ste A, Bozeman, MT 59718, submitted a Subdivision Preliminary Plat Application on ~ 85 acres to be subdivide into as many as 220 single- and multi-household lots with an optional church lot, streets, park and open space areas on property legally described as a portion of NW 1/4, Section 2, T2S, R5E, PMM, City of Bozeman, Gallatin County, Montana; and WHEREAS, the applicant is requesting the following PUD relaxation; 1. Section 18.16.060, Building Height; to allow a maximum building height of 42 feet for a roof pitch equal to of greater than 5:12. WHEREAS, the proposed Subdivision Preliminary Plat Application has been properly submitted, reviewed, and advertised in accordance with the procedures of Section 18.76 of the Bozeman Municipal Code; and WHEREAS, the City of Bozeman Planning Board held a public hearing on Wednesday, September 5, 2007, to receive and review all written and oral testimony on the request for said Subdivision Preliminary Plat Application; and WHEREAS, the City of Bozeman Planning Staff presented the staff report on the request for said Subdivision Preliminary Plat Application; and WHEREAS, relaxation #1 is addressed by Plan Condition #1: The relaxation of Section 18.16.060, Building Height; to allow a maximum building height of 42 feet for a roof pitch equal to or greater than 5:12 shall be restricted to multi-household apartment type dwellings; and 157 West Winds PUD Phases 4-8 Subdivision Preliminary Plat # P07028 2 of 10 WHEREAS, the applicant described the application, expressed concerns with two recommended conditions of approval forwarded by various reviewing agencies and the Development Review Committee; and WHEREAS, the applicant expressed concern with recommended condition of approval #14, explaining that it was a hardship to have to comply with the Fire Department’s condition; and WHEREAS, the applicant expressed concern with recommended condition of approval #20f, explaining that the CAHAB condition needed to be clarified, and #20c, explaining that there are too many townhouse lots in West Winds already on the market; and WHEREAS, no members of the public were present speaking in favor of or opposition to said Subdivision Preliminary Plat; and WHEREAS, members of the City of Bozeman Planning Board discussed 310 and 404 permits, and the section line ditch in the Davis Lane right-of-way; and WHEREAS, members of the City of Bozeman Planning Board discussed street lights on these arterials versus the street lights on South 19th Avenue (a State secondary highway); and WHEREAS, members of the City of Bozeman Planning Board discussed access proximity, block length and pedestrian walkways, the height request, and the updated traffic impact study; and WHEREAS, members of the City of Bozeman Planning Board discussed condition of approval #20 as recommended by CAHAB; and WHEREAS, members of the City of Bozeman Planning Board discussed condition of approval #14 as recommended by the Fire Department, the need for a fire station, the location of a fire station, and if a subdivision should be required to provide for public safety before they should be able to proceed; and WHEREAS, the City of Bozeman Planning Board reviewed the application against the requirements of the Montana Subdivision and Platting Act, and found that the Subdivision Preliminary Plat Application would comply with those requirements with the recommended conditions of approval; and NOW, THEREFORE, BE IT RESOLVED, that the City of Bozeman Planning Board, on a vote of 5 to 0, recommends to the Bozeman City Commission that the Commission consider moving forward on acquisition of the fire station site, that condition of approval 20f be amended, and the ~ 85 acres to be subdivide into as many as 220 single- and multi-household lots with an optional church lot, streets, park and open space areas, on property zoned R-3 (Residential Medium Density District), which is generally located east of Davis Lane and north of Oak Street, on property legally described as a portion of NW 1/4, Section 2, T2S, R5E, PMM, City of Bozeman, Gallatin County, Montana, be approved with the 52 conditions which follow; and 158 West Winds PUD Phases 4-8 Subdivision Preliminary Plat # P07028 3 of 10 1. With a proposed block length of ~ 1,080 feet from Breeze Lane to Tschache Lane, the street pattern in West Winds shall be designed to provide a city standard street connection to a full access intersection at Vaquero Street and Davis Lane, subject to Engineering and Planning Department review and approval. 2. With a proposed block length of ~ 975 feet from Oak Street to Vaquero Street, the street pattern in West Winds shall be designed to provide a street connection of Breeze Lane extended to a partial access intersection at Davis Lane, final location subject to Engineering and Planning Department review and approval. 3. Due to topography, the presence of critical lands, access control, and adjacency to open space, block lengths may exceed 400 feet but may not exceed 1, 087 feet. Block lengths shall not exceed 600 feet without a public right of way with pedestrian walkway. 4. Due to separation of residential development from traffic arterials and to overcome specific disadvantages of topography and orientation, block widths may be less than 200 feet or more than 400 feet in width. Block widths shall not exceed 600 feet without a public right of way with pedestrian walkway. 5. The remainder of the original tract of record (and of each phase of the subdivision)) shall be platted as an undevelopable lot in accordance with §18.74.080.B.6, BMC, with the following language placed on each undevelopable lot of the final plat “Lot development subject to further subdivision review.” No public improvements shall be required for the undevelopable lot until it is subdivided as a lot which is not subject to this restriction. The following language shall either be placed on the face of the plat or in a separate executed document to be recorded with the final plat. NOTICE IS HEREBY GIVEN to all potential purchasers of Lot X, of XXXXX Subdivision, City of Bozeman, Gallatin County, Montana, that the final plat of the subdivision was approved by the Bozeman City Commission without completion of on and off-site improvements required under the Bozeman Municipal Code, as is allowed in Chapter 18.74 of the Bozeman Municipal Code. As such, this Restriction is filed with the final plat that stipulates that any use of this lot is subject to further subdivision, and no development of this lot shall occur until all on and off- site improvements are completed as required under the Bozeman Municipal Code. THEREFORE, BE ADVISED, that Building Permits will not be issued for Lot of XXXXX Subdivision, City of Bozeman, Gallatin County, Montana until all required on and off-site improvements are completed and accepted by the City of Bozeman. No building or structure requiring water or sewer facilities shall be utilized on this lot until this restriction is lifted. This restriction runs with the land and is revocable only by further subdivision or the written consent of the City of Bozeman.” 6. The approved park master plan shall be amended to address any additions, revisions or changes from the previous approval as well as the relocation of the trail corridor, locations of sewer 159 West Winds PUD Phases 4-8 Subdivision Preliminary Plat # P07028 4 of 10 mains, stormwater facilities and all easements, and shall be approved by the Park and Recreation Superintendent, prior to Final Plat approval. 7. The covenants shall address street trees, and shall include a planting note stating that the planting hole shall be at least twice the diameter of the root ball, that the root flare of the newly planted tree is visible and above ground, and there should be a mulch ring 3’ -4’ in diameter around each newly planted boulevard tree. 8. Note 6 on Phase 6 shall be removed or corrected – a church is not limited commercial, it is a community center. 9. All subdivision final plats shall comply with the final approved PUD plan and Development Guidelines for the West Winds Planned Unit Development. 10. A note shall be included on the plat for all multi family lots describing park dedication allowances; e.g. park dedication requirements for Lot 12, Block 7 have been met for 48 dwelling units, at the time of subsequent development, when net residential density becomes known, park dedication requirements shall be met for any additional density in accordance with the BMC. 11. The park shall be titled “Public Park”. The open space shall be titled “Open Space, Public Access”. Notes shall be included on the plat describing ownership and maintenance responsibility for all parks, open space and/or other common facilities and areas, e.g.: public park, dedicated to the city and maintained by the property owners association; and open space, public access, owned by the property owners, maintained by the property owners association, etc. Park land, open space areas and storm water facilities shall not be titled as lots or tracts but shall be numbered. 12. Street lighting, including pathway intersection lighting, shall be installed by the subdivider. Light locations and specifications shall be provided to the City Engineer for review and approval with the public improvements plans and specifications. All street light poles shall be installed a minimum of 10’ from any water or sewer main or appurtenance. 13. Street lighting SILD information for operation and/or maintenance shall be submitted to the Clerk of Commission directly after Preliminary Plat approval in hard copy and digital form. The final plat will not be deemed complete until the resolution to create the SILD has been approved by the City Commission. 14. Final plat approval for West Winds Phases 4-8 shall not be granted, nor shall any preconstruction meetings be held or construction of any subdivision-related infrastructure commence, until an appropriate fire station site within the area defined in the Master Plan (i.e., between Flanders Mill Road and North 27th Avenue, and between Durston Road and Baxter Lane) has been secured. 15. Water rights, or if water rights are not available cash-in-lieu thereof, as calculated by the City Engineer, is due with the final plat. 160 West Winds PUD Phases 4-8 Subdivision Preliminary Plat # P07028 5 of 10 16. Buildings proposed for construction with crawl spaces or basements shall include Engineer Certification regarding depth of ground water and soil conditions and proposed mitigation methods to be submitted with each Building Permit. The Final Plat shall include a notation that due to high ground water conditions full or partial basements are not recommended. 17. Applicant shall provide a soils report, along with building plans, to the Building Division, recommending types of foundations. If development shall occur in phases, the soils report may address those lots within the proposed phase. 18. All plans and specification shall comply with the current version (including all addenda) of the City of Bozeman Design Standards and Specifications Policy and the City of Bozeman Modifications To Montana Public Works Standard Specifications Fifth Edition that have been adopted at the time of approval of the plans and specifications. 19. The final plat shall comply with the standards identified and referenced in the Bozeman Municipal Code. The applicant is advised that unmet code provisions, or code provisions that are not specifically listed as conditions of approval, does not, in any way, create a waiver or other relaxation of the lawful requirements of the Bozeman Municipal Code or state law. 20. To support the affordability of housing: a. To ensure a mix of housing types in Phases 4 to 8, the area south of Winter Park Street, in Phases 4-8, shall include multi family housing; townhouses and/or living/elderly care facilities and apartments. b. The minimum density of the West Winds PUD shall not be less than six dwelling units per acre. c. The number of townhouse lots may be increased at the time of final plat to comply with any increase in the number of townhouse lots on the approved final PUD plan. d. Townhouses are preferable to condos. Condos are hard to sell as homes or resell as homes if some of the units convert to rentals. e. Builders of attached units shall have a FHA inspection to allow for more types of affordable financing. f. Encourage connectivity with the Park. Connectivity with the Park shall be provided. (As amended by Planning Board) 21. Stormwater Master Plan: A Stormwater Master Plan for these phases of the subdivision for a system designed to remove solids, silt, oils, grease and other pollutants from the runoff from the private and public streets and all lots must be provided to and approved by the City Engineer. The master plan must depict the maximum sized detention/retention basin location, show location of and provide easements for adequate drainage ways within the subdivision to transport runoff to the stormwater receiving channel. The plan shall include sufficient site grading and elevation information (particularly for the basin sites, drainage ways and finished lot grades), typical stormwater detention/retention basin and discharge structure details, basin sizing 161 West Winds PUD Phases 4-8 Subdivision Preliminary Plat # P07028 6 of 10 calculations and a stormwater maintenance plan. Any stormwater ponds located within a park or open space shall be designed and constructed to be conducive to the normal use and maintenance of the open space. Stormwater ponds for runoff generated by the subdivision (e.g., general lot runoff, public or private streets, common open space, parks, etc.) shall not be located in easements within privately owned lots. While the runoff from the individual lots will be dependent on the intensity of use on each lot, the maximum sizing of the storm retention facilities for each lot will be established based on maximum site development. Final facility sizing may be reviewed and reduced during design review of the FSP for each lot. 22. Plans and specifications and a detailed design report for water and sewer main extensions, streets and storm drainage facilities, prepared by a Professional Engineer (PE) registered in the state of Montana, shall be provided to and approved by the City Engineer. Water and sewer plans shall also be approved by the Montana Department of Environmental Quality. The Applicant shall also provide Professional Engineering services for Construction Inspection, Post-construction Certification, and preparation of mylar Record Drawings. Construction shall not be initiated on the public infrastructure improvements until the plans and specifications have been approved and a pre-construction conference has been conducted. All plans and specification shall comply with the current version (including all addenda) of the City of Bozeman Design Standards and Specifications Policy and the City of Bozeman Modifications to Montana Public Works Standard Specifications Fifth Edition that have been adopted at the time of approval of the plans and specifications. No building permits shall be issued prior to substantial completion and City acceptance of the required infrastructure improvements unless all of the requirements of Section 18.74.030.D of the Bozeman Municipal Code are met to allow for concurrent construction. 23. All infrastructure improvements including 1) water and sewer main extensions, and 2) public streets, curb/gutter, sidewalks fronting parks, open space, rear yard frontages or other non-lot frontages, and related storm drainage infrastructure improvements shall be financially guaranteed or constructed prior to Final Plat approval. City standard residential sidewalks shall be constructed on all public street frontages of a property prior to occupancy of any structure on the property. Upon the third anniversary of the plat recordation of any phase of the subdivision, any lot owner who has not constructed said sidewalk shall, without further notice, construct within 30 days said sidewalk for their lot(s), regardless of whether other improvements have been made upon the lot. This condition shall be included on the final plat for the subdivision. 24. Project phasing shall be clearly defined including installation of infrastructure. 25. All proposed private utilities to serve the subdivision shall be shown on the public infrastructure plans and specifications. 162 West Winds PUD Phases 4-8 Subdivision Preliminary Plat # P07028 7 of 10 26. The location of and distinction between existing and proposed sewer and water mains and all easements shall be clearly and accurately depicted on the plans, as well as all nearby fire hydrants and proposed fire hydrants. 27. Any easements needed for the water and sewer main extensions shall be a minimum of 30 feet in width with the utility located in the center of the easement. In no case shall the utility be less than 10 feet from the edge of the easement. All necessary easements shall be provided prior to final plat approval and shall be shown on the plat. Wherever water and/or sewer mains are not located under or accessed from improved streets, a 12 foot wide all weather access drive shall be constructed above the utilities to provide necessary access. 28. Street names must be approved by the Gallatin County GIS office and City Engineering office prior to final plat approval. 29. The developer shall make arrangements with the City Engineer's office to provide addresses for all individual lots in the subdivision prior to filing of the final plat. 30. The location of mailboxes shall be coordinated with the City Engineering Department prior to their installation. 31. The Montana Department of Fish, Wildlife and Parks, SCS, Montana Department of Environmental Quality and Army Corps of Engineer's shall be contacted regarding the proposed project and any required permits (i.e., 310, 404, Turbidity exemption, etc.) shall be obtained prior to plan and specification approval. 32. If construction activities related to the project result in the disturbance of more than 1 acre of natural ground, an erosion/sediment control plan may be required. The Montana Department of Environmental Quality may need to be contacted by the Applicant to determine if a Stormwater Discharge Permit is necessary. If a permit is required by the State, the Developer shall demonstrate to the City full permit compliance. 33. The applicant shall submit a construction route map dictating how materials and heavy equipment will travel to and from the site in accordance with Section 18.74.020.A.1 of the Bozeman Municipal Code. This shall be submitted as part of the final site plan for site developments, or with the infrastructure plans for subdivisions. It shall be the responsibility of the applicant to ensure that the construction traffic follows the approved routes. 34. All construction activities shall comply with Section 18.74.020.A.2 of the Bozeman Municipal Code. This shall include routine cleaning/sweeping of material that is dragged to adjacent streets. The City may require a guarantee as allowed for under this section at any time during the construction to ensure any damages or cleaning that are required are complete. The developer shall be responsible to reimburse the City for all costs associated with the work if it becomes necessary for the City to correct any problems that are identified. 35. Ditch relocation: 163 West Winds PUD Phases 4-8 Subdivision Preliminary Plat # P07028 8 of 10 a. The Montana Fish, Wildlife and Parks shall be contacted by the Applicant regarding the proposed relocation and any required permits (i.e., 310, 404, Turbidity exemption, etc.) shall be obtained prior to FSP approval. b. The Applicant shall comply with all parts of section 18.42.060.D for any ditch relocation. 36. In locations where Baxter Lane and Davis Lane are being improved, the various irrigation ditches and/or streams shall be either relocated outside the right-of-way, accommodated in an approved center median, or placed in a pipe. The plan for the irrigation ditches shall be reviewed and approved by the ditch owner. 37. Stormwater generated by the proposed subdivision shall not be discharged to an irrigation facility. 38. Any public street rights of way for which easements have been provided (i.e. Oak Street) shall be dedicated to the City on the Final Plat for this subdivision. The applicant shall also dedicate an additional 5 ft for the south half of Baxter Lane. 39. City standard curb, gutter and sidewalk shall be provided along all streets in the subdivision. 6 foot wide sidewalk will be required in the standard location on the development’s side of West Oak Street, Davis Lane, and Baxter Lane. 40. All typical street sections, including sidewalk location within the right-of-way and provisions for bicyclists shall be in conformance with the street standards recommended in the Greater Bozeman Area Transportation Plan, 2001 Update, unless otherwise approved by the City Commission, or by the City Engineer through the plan and specification review and approval process. 41. A schematic signage plan for the subdivision, noting any proposed traffic calming measures, shall be provided with the design report for review and approval by the City Engineer. 42. Parking will not be allowed on West Oak Street, Baxter Lane, or Davis Lane. 43. If approved for concurrent construction, detailed review and approval of the concurrent construction plans will be part of the infrastructure plan and specification review process. Building permits may not be issued until the plans are approved. 44. A 1 foot no access easement shall be shown on the final plat along the entire frontage of West Oak Street, Baxter Lane, and Davis Lane. 45. The Traffic Impact Study, 2007 Update, indicates that the North 27th Avenue intersections with West Oak Street and Durston Road will have level of service (LOS) at D or below prior to final build-out of the subdivision. Bozeman Municipal Code section 18.44.060.D states “All arterial and collector streets, and movements on intersection approach legs designated as arterial or collector streets, shall operate at a minimum level of service C.” The improvements necessary for each phase to raise the level of service at these intersections to Level of Service C must be 164 West Winds PUD Phases 4-8 Subdivision Preliminary Plat # P07028 9 of 10 installed and accepted by the City of Bozeman prior to the issuance of building permits, unless approved for concurrent construction. To determine the timing of the improvements, an update to the Traffic Impact Study shall be provided with the design report for each phase. Also, the update shall identify when the exclusive westbound left turn lane at West Oak Street and N 27th Avenue shall be installed. 46. Baxter Lane and Davis Lane, along the property boundary, shall be improved, as part of this development; to one half of a minor arterial standard as shown in the Greater Bozeman Area Transportation Plan 2001 Update and shall match the sections built by Baxter Meadows. Where one half of a standard arterial is being built 12 feet of pavement for the opposing lane of travel shall be provided. City standard curb and gutter, and 6 foot wide sidewalk will be required in the standard location on the development’s side of the street. Detailed review of the street and intersection design, and approval by the City Engineer will be required as part of the infrastructure plan and specification review process. 47. The east half of Davis Lane from West Oak Street to Baxter Lane must be constructed and accepted by the City prior to filing the Final Plat for any phase along Davis Lane, or financially guaranteed and completed prior to issuance of building permits, unless approved for concurrent construction. The design of Davis Lane is also to address the existing irrigation ditch and provide a median. The south half of Baxter Lane, from Buckrake Avenue to Davis Lane must be constructed and accepted by the City prior to filing the Final Plat for any phase along Baxter Lane, or financially guaranteed and completed prior to issuance of building permits, unless approved for concurrent construction. The infrastructure improvements shall include improvements to the intersections of Davis Lane at Baxter Lane and West Oak Street. 48. Each phase of the subdivision shall have a second means access. 49. Per the access standards in Section 090.D.3 of Chapter 18.44 of the Bozeman Municipal Code, the intersections of Windward Ave at Baxter Lane and Breeze Lane at Davis Lane will be partial access. 50. Ensure the sanitary sewer manhole spacing provided does not exceed the maximum manhole spacing, per the COB Design Standards and Specifications Policy. 51. Each phase of the subdivision shall have a minimum of two separate water main feeds. Single source loops created by phasing will not be allowed. 52. Hunters Way (from Baxter Lane to Oak Street) shall include a Signed Bike Route since this will be an extension of an existing Signed Bike Route on Hunters Way. DATED THIS 5th DAY OF SEPTEMBER, 2007 Resolution #P-07028 _____________________________ ____________________________ Andrew C. Epple, Planning Director Eric Henyon, Acting Chairperson Planning & Community Development Dept. City of Bozeman Planning Board 165 West Winds PUD Phases 4-8 Subdivision Preliminary Plat # P07028 10 of 10 166 *** MINUTES *** CITY OF BOZEMAN PLANNING BOARD WEDNESDAY, SEPTEMBER 5, 2007 7:30 P.M. ITEM 1. CALL TO ORDER AND ATTENDANCE Acting Chair Erik Henyon called the regular meeting of the City Planning Board to order at 7:30 p.m. and directed the secretary to record the attendance. Members Present: Erik Henyon, Acting Chair Caren Roberty Randy Carpenter Ed Sypinski Brian Caldwell Members Absent: JP Pomnichowski (excused) Eric Roset Bill Quinn (excused) Kaaren Jacobsen (excused) Staff Present: Martin Knight, Planner Lanette Windemaker, Contract Planner Robin Sullivan, Recording Secretary Guests Present: Priscilla Walcheck, 5551 Cottonwood Road Rob Pertzborn, Intrinsik John Dunlap ITEM 2. PUBLIC COMMENT (0-15 MINUTES) {Limited to any public matter within the jurisdiction of the Planning Board and not scheduled on this agenda. Three-minute time limit per speaker.} Seeing there were no members of the public wishing to give any comment, Acting Chair Henyon closed this portion of the meeting. ITEM 3. MINUTES OF AUGUST 21, 2007 167 - 2 - Seeing there were no corrections, changes or additions to the minutes, it was moved by Caren Roberty, seconded by Ed Sypinski, that the minutes of the regular meeting of August 21, 2007, be approved as submitted. The motion carried on a 5-0 vote. ITEM 4. PROJECT REVIEW Subdivision Preliminary Plat #P-07028 (West Winds Phases 4-8) - A Major Subdivision Preliminary Plat Application on behalf of the owners, Cascade Development, and the representatives, HKM Engineering, to allow the subdivision of ~ 85 acres into 220 lots in the West Winds Planned Unit Development, zoned R-3 (Residential Medium Density District). The property is legally described as NW ¼, Section 2, T2S, R5E, PMM, City of Bozeman, Gallatin County, Montana. (Windemaker) Staff Report: Contract Planner Lanette Windemaker briefly reviewed this application for preliminary plat for Phases 4 through 8 of West Winds Subdivision, noting that the plats for Phases 1 through 3 have been finalized. The property is generally bounded by Baxter Lane, West Oak Street, North 27th Avenue and Davis Lane. The application for preliminary plat includes a variety of lots, including single-family, single-family townhouse, multi-family, and a church lot, up to a potential of 220 lots. She stated the applicant wants to retain the idea of the two planned unit development options like was previously approved and has submitted two options for some of the phases. She noted that, in conjunction with this application, the applicant is seeking a modification to amend the building height; and that is an issue to be addressed by the City Commission. Contract Planner Windemaker noted that two options have been provided for Phases 4 and 5, one being a multi-family option and the other being a single-family townhouse option. Phase 6 includes the church block and single-family residential; Phase 7 is single-family residential with the remaining one- third of parkland dedication; and Phase 8 is residential located in the northwest corner of the project. The Contract Planner stated that the Gallatin Valley Land Trust has submitted a letter expressing concern about the location of the east/west linear green space with trail across the top of Phase 5 and suggesting that it be relocated to the south side of Winter Park. She then forwarded staff’s position that the present location is preferable, particularly since there is no certainty that sidewalks will be installed adjacent to the parkland. Contract Planner Windemaker stated that staff has reviewed this application in light of the applicable criteria, and staff’s comprehensive findings are contained in the written staff report. Based on those findings, staff has forwarded a recommendation for approval subject to several conditions. She indicated that, while none of the conditions are unusual, the applicant has voiced concern about Condition Nos. 14 and 20. She noted Condition No. 14 is the standard condition that the Fire Department is recommending for any development in this quadrant of the community; and Condition No. 20 has been forwarded by the Community Affordable Housing Advisory Board. Questions for Staff: 168 - 3 - Responding to questions from Brian Caldwell, Contract Planner Windemaker stated that parks do not have to be physically attached; rather, sidewalks and trails can provide connectivity. In this instance she finds there is not a lack of connectivity. Further responding to Brian Caldwell, Contract Planner Lanette Windemaker stated that the street lighting required is dependent on the type of street, its design and the speed limit. She noted that South 19th Avenue, which was the subject of a lighting discussion at the last Planning Board meeting, is designated as a state highway with a speed limit of 60 miles per hour; and the lighting standards for that roadway are substantially different from those for a local major arterial with a speed limit of 25 miles per hour. Responding to Ed Sypinski, Contract Planner Windemaker confirmed the only formalized trail corridor that goes through all phases of the subdivision is the one on the north side of Winter Park. She noted that where block lengths exceed 600 feet, mid-block pedestrian crossings will be provided, and there will be short pedestrian trails through various blocks within the subdivision. Responding to Erik Henyon, the Contract Planner stated that Project Engineer Sue Stodola has worked with the applicant to ensure that the streets meet spacing requirements. Further responding to Erik Henyon, the Contract Planner stated that parking requirements must be met for all phases, no matter which option is selected. She noted that the assisted living component will have a lower parking requirement and then indicated that some on-street parking may be counted toward meeting parking requirements, except there is no parking along an arterial. Responding to Erik Henyon, Contract Planner Windemaker stated that the fire service overlay and map in the Bozeman 2020 Community Plan has been superseded by the new fire master plan that was adopted in November 2006. Responding to additional questions from Erik Henyon, Contract Planner Windemaker confirmed that this subdivision is exempt from the new work force housing ordinance. She then addressed the building height relaxation being sought, noting that the maximum height for the steepest pitch roof in the R-3 zone is 42 feet; and the applicant is requesting a relaxation to allow a 42-foot height with a lower pitch roof. Applicant Presentation: Clint Litle, HKM Engineering, voiced concurrence with the staff report as presented by Contract Planner Windemaker. He stated that the preliminary plat before the Board is in compliance with the planned unit development for West Winds and meets the Engineering Department’s requirements. He indicated that all street lighting will be in compliance with the Unified Development Ordinance, and parking will also meet code requirements. He stated that The Village is a senior housing development, with independent living homes next to the large building. He noted that a traffic impact study was done with the original planned unit development for this subdivision, and the Engineering Department has determined it does not need to require renewing of that study because of recent work completed on North 19th Avenue and West Oak Street. Mr. John Dunlap, applicant, noted that modifications and adjustments have been made to the original conceptual plans for this subdivision to ensure that connectivity with neighboring developments works well. He then turned his attention to Condition No. 14, which requires that an appropriate fire station 169 - 4 - site be secured prior to final plat approval and construction of any infrastructure improvements. He noted that when he went through the planned unit development process for this subdivision, he had to make sure that the development matched with the fire overlay and that public safety could be satisfactorily provided. He is now caught in the middle of a change because a revised fire master plan has been adopted. He stressed that he embraces health and safety issues, but Condition No. 14 as written presents a significant hardship for him and asked that the condition be stricken or that, at a minimum, he be granted the same standards as the neighboring Baxter Meadows Subdivision. He then turned his attention to Condition No. 20, noting that connectivity has been provided throughout the subdivision, including connections to the park as referenced in No. 20.f. He noted that Item No. 20.c. encourages townhouse lots, but cautioned that the West Winds community is already overloaded on townhouse lots. He noted that the RSL lots include a restriction on the size of dwelling units and directly ties to the affordable housing issue. He concluded by stating he agrees with the remainder of the conditions and will comply with them. Questions for Applicant: Responding to Caren Roberty, Mr. Dunlap stated the requested building height relaxation is to allow a three-story building with a 5:12 pitch at the maximum height allowed in an R-3 zone. He stated the building is to be located in the northern two blocks of Phase 3, along Breeze Lane. Responding to Erik Henyon, Clint Litle stated that Lynn Bacon has been retained by the applicant, and she is applying for the 310 and 404 permits that are needed under the planned unit development. Responding to Brian Caldwell, Clint Litle stated that the watercourse along Davis Lane and any wetland mitigation will be done in conjunction with the planned unit development. He assured the Board that they will work closely with the irrigation ditch company and will ensure the ditch remains open and free of any obstruction. He stated that the roadway is to be located in its current alignment with the irrigation ditch located in the center median, similar to the North 27th Avenue alignment where the power poles are located in the center median. Public Testimony: Seeing there were no members of the public wishing to comment on this matter, Acting Chair Henyon closed this portion of the meeting. Discussion: Responding to questions from Brian Caldwell, Contract Planner Lanette Windemaker stated she has heard the site for the new fire station is near resolution; however, she cautioned that under the condition as written, it must be finalized before this subdivision can move forward. Ed Sypinski stated he will weigh in on the side of public safety. He voiced his concern about this quadrant of the community, noting that with all of the development in this area, a fire station is needed. As a result, he feels Condition No. 14 should be retained. Randy Carpenter voiced his agreement, stating he has heard no good argument to strike Condition No. 14. Brian Caldwell suggested that the issue of the fire station location should be addressed separate from 170 - 5 - any specific application, noting that it could then be the subject of a more direct discussion. Caren Roberty addressed the various elements in Condition No. 20, noting these were recommendations from the Community Affordable Housing Advisory Board. She noted that when this application was presented to the CAHAB, they viewed the large church parcel as a significant loss of townhouses, which they felt was the best affordability option. She stated the CAHAB has been told repeatedly that RSLs are not affordable, so the CAHAB is trying to encourage more attached units because they find unattached units are not affordable. She proposed that Item 20.f. could be stricken, stating that she feels the issue of connectivity has already been addressed. She then turned her attention to Condition No. 14, stating she supports retaining the condition as written. She suggested that the developers in this area should become actively involved in trying to find a site for the new fire station, although she recognizes that the City and the County need to get that process moving. Erik Henyon asked about the condition that was negotiated with Baxter Meadows. He suggested another option would be to allow installation of the subdivision infrastructure and tie the fire station site to the issuance of building permits. Brian Caldwell suggested that the Board forward a second recommendation to the Commission instead of conditioning projects in this manner. He then noted he is not sure the Board should wordsmith a condition that has been written by the Fire Marshal. Randy Carpenter stated he does not want to make any changes to the conditions, noting that the Commission may have better information on which to make its decision. Ed Sypinski reiterated his support for Condition No. 14, noting he will always weigh in on the side of public health and safety. Erik Henyon suggested that the motion could include the conditions as proposed, with a recommendation that the Commission look at Condition No. 14; the language in the conditions of approval for Baxter Meadows Subdivision, Phase 4; and the option of tying the fire station site to the issuance of building permits rather than installation of the subdivision infrastructure. Responding to Erik Henyon, Caren Roberty confirmed that she feels Item No. 20.f. should be stricken. Following a brief discussion, it was determined the condition should be changed to read “Encourage connectivity with the park shall be provided.” In response to comments from other Board members, Caren Roberty stated the CAHAB’s experience is that it is almost impossible to finance a condominium because such a large percentage of them become rentals and the values then drop. Motion and Vote: It was moved by Caren Roberty, seconded by Ed Sypinski, that the Planning Board recommend approval of the preliminary plat for West Winds Subdivision, Phases 4 through 8, under Application No. P-07028 as conditioned by staff, with Condition No. 20.f. amended to read “Encourage 171 - 6 - connectivity with the park shall be provided.”; and encourage the City and County to begin the process of taking action on getting the site for the new fire station selected. The motion carried on a 5-0 vote. Growth Policy Amendment #P-07036 (Cottonwood Crossing) – A Growth Policy Amendment Application on behalf of the owners, Betty Madill Trustee of B. Madill Inter Vivos Trust, and the representatives, Intrinsik Architecture, to amend the Land Use Designation on 6.6 acres from “Residential” to “Business Park”. The property is legally described as Ne¼, Section 16, T2S, R5E, PMM, City of Bozeman, Gallatin County, Montana. (Knight) Staff Report: Assistant Planner Martin Knight noted this application is for a growth policy from “Residential” to “Business Park” on 6.6 acres at the southwest corner of the intersection of Huffine Lane and Cottonwood Road. He referenced two previous applications for this property, noting that in the Spring and Fall of 2005, applications were submitted to amend the land use designation in the growth policy to “Neighborhood Commercial”. He stated that, at that time, neither the staff nor the City Commission was supportive of the request, determining that commercial development along Huffine Lane west of Cottonwood Road was not appropriate. Assistant Planner Knight stated that staff has reviewed this application in light of the applicable criteria, and staff’s findings are contained in the written staff report. He noted that staff is not supportive of the requested amendment as they found it does not satisfy all of the review criteria. He cautioned that approval would set a precedent for extending commercial uses along the south side of Huffine Lane further west than had been anticipated. Assistant Planner Martin Knight reminded the Board that the Bozeman 2020 Community Plan is currently undergoing an update; and one of the recommendations being considered is the elimination of the “Business Park” land use designation because it focuses on a single land use pattern, is land consumptive, and does not reflect current market trends toward mixed use. The Assistant Planner concluded by stating that this application will be heard before the City Commission at its September 17 meeting. Applicant Presentation: Rob Pertzborn, Intrinsik, representing Covenant Investments LLC and the Madill family, distributed copies of his speech outline, noting it includes his key points. He characterized this as a simple change, stressing that he is not asking for a zone change but is asking for a different percentage of the allowed uses. He noted that the subject parcel has 440 feet of frontage at the intersection of two arterials, with the traffic on Huffine Lane approaching 20,000 average daily trips. He stated this type of location does not lend itself well to residential development. He noted that, as a result, he is requesting the change in land use designation to allow a greater percentage of office space, and stressed that no retail space is being proposed. Rob Pertzborn noted that the property across Huffine Lane has an underlying land use designation of “Business Park”. He stated that allowing the same land use designation for this site, when combined 172 - 7 - with the existing “R-O” zoning, the entryway corridor guidelines, and the development manual for Loyal Garden, will ensure compatibility with the area while allowing a more appropriate mix of office and residential uses. Questions for Staff and Applicant: Responding to questions from Brian Caldwell, Assistant Planner Martin Knight cautioned that approval of this application cannot be based on a specific site plan; rather, development of the site will be done through a separate application. He noted that, if this application were being reviewed in conjunction with a site plan application, then that information could be taken into consideration but that is not the case in this instance. Further responding to Mr. Caldwell, the Assistant Planner confirmed that it would be possible to change the percentages between office and residential development on the subject property through the planned unit development process. Responding to Erik Henyon, Rob Pertzborn confirmed that under the current “Residential Office” land use designation, a minimum of 51 percent must be residential while up to 49 percent can be office development. Under the requested “Business Park” land use designation and the existing “Residential Office” zoning designation, up to 100 percent of the site could be office development. Further responding to Erik Henyon, Rob Pertzborn stated he is not sure what percentages of residential and office uses will be proposed; however, he stressed this is not the place for residential development. He noted it would be good to do a nice grouping of offices on the two lots fronting on Huffine Lane, with a look at the market helping to identify the mix of residential uses that could be incorporated on the third lot, which fronts along Cottonwood Road. Public Comment: Priscilla Walcheck, 5551 Cottonwood Road, noted she lives just south of this property. She stated that, while she has no problem with changing the land use designation for the two lots fronting on Huffine Lane, she does object to allowing offices or businesses along Cottonwood Road. Discussion: Brian Caldwell stated he feels the Planning Board should try to plan development along Huffine Lane, rather than fearing what changes might be proposed. He acknowledged that the Board is unable to consider massing, design and architecture at this time, which is where the fear arises. He noted, however, that he supports modifying the land use designation for the two lots fronting on Huffine Lane, while leaving the designation for the lot fronting on Cottonwood Road the same. Ed Sypinski stated that he agrees in principle; however, he cannot support the change without seeing specific development plans for the site. Caren Roberty stated she is skeptical of approving a “Business Park” land use designation when it may be eliminated in the growth policy update and noted that, ideally, she would like to see a reasonable amount of neighborhood commercial allowed for this corner. In the alternative, however, she finds Brian Caldwell’s proposal to modify the land use designation for the two lots fronting on Huffine Lane would be appropriate while leaving the land use designation for the lot fronting on Cottonwood Road as residential. 173 - 8 - Randy Carpenter stated he is surprised that this application has been submitted at a time when the growth policy is being updated and this area is so uncertain and controversial. He agrees that a mix of office and residential use makes more sense than residential development. He concluded by stating that he is inclined not to support this application, remaining consistent with previous decisions, and to wait for the update of the growth policy. Caren Roberty suggested that, if the Board chooses not to recommend approval of this amendment, it should make a fairly strong statement of how it feels this corner should be developed so it can be considered in the growth policy update. Erik Henyon stated that residential development on this corner is not appropriate. He agrees that neighborhood commercial would be a better use of this site, particularly with the growth that is occurring in this area; however, he recognized that type of use has been consistently denied. He stated that amending the land use designation to “Business Park” on the two lots fronting on Huffine Lane while leaving the land use designation for the lot fronting on Cottonwood Road as “Residential” would allow for a true mixed use development. He does feels it would be appropriate to partially approve this amendment in that manner, stating he feels that the growth policy update would allow for that type of use anyway. He concluded by noting the applicant has a proven track record of providing quality development, and the Board must rely on the process to ensure that development of the site is done appropriately. Randy Carpenter expressed his concern that this is an important intersection in the community, and that the Board is being asked to make a change without any community discussion. He then reiterated his position that the land use designation for this corner should be determined through the growth policy update process. In light of additional discussion, the Board members all agreed that residential development fronting on Huffine Lane is not appropriate and that a good mix of office and residential development would be acceptable; however, some of the members continued to voice concerns about considering this amendment when the growth policy update process is underway. Motion and Vote: It was moved by Ed Sypinski, seconded by Randy Carpenter, that the Planning Board recommend to the Commission approval of the growth policy amendment land use designation from “Residential” to “Business Park” on the two lots adjacent to Huffine Lane but not on the lot adjacent to Cottonwood Road, requested under Application No. P-07036, with the conditions recommended by staff. The motion carried on a 3-2 vote, with Caren Roberty, Brian Caldwell and Erik Henyon voting Aye and Ed Sypinski and Randy Carpenter voting No. Because less than five members voted to approve the requested amendment, this is an unofficial recommendation to the City Commission. ITEM 5. NEW BUSINESS September 18 meeting. Caren Roberty asked if there will be a quorum for the September 18 meeting. Randy Carpenter indicated that he will be present, although previous e-mails might have suggested otherwise. Vice Chair. Responding to Brian Caldwell, Erik Henyon stated that selection of a new Vice Chair is scheduled for the next meeting. 174 - 9 - Invitations to meetings. Randy Carpenter invited interested Planning Board members to attend a meeting on subdivision design in small towns, to be held on September 25 and 26 in Three Forks. He also invited members to attend the panel discussion sponsored by the Gallatin Grassroots Forum and NewWest.com on September 12 at the Museum of the Rockies. Topics for upcoming meetings. The Board members requested that they be given updates on certain topics as soon as possible, before delving into the master plan update. They include: (1) presentation from Chuck Winn on the fire service areas and new master plan, (2) presentation from the Police Department, (3) discussion with the School Board on upcoming needs, and (4) a presentation from Chris Saunders on the maps for the sewer and water services for the next twenty years. They recognized that the information garnered from these presentations will be beneficial background information for updating the City’s growth policy. ITEM 6. ADJOURNMENT There being no further business to come before the Planning Board at this time, Acting Chair Erik Henyon adjourned the meeting at 9:14 p.m. ______________________________________ ______________________________________ Erik Henyon, Acting Chair Andrew C. Epple, Director Planning Board Planning & Community Development City of Bozeman City of Bozeman 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 Phases IV, V, VI, VII, & VIII Preliminary Plat & Subdivision Application West Winds Planned Community Prepared for: Cascade Development Inc 1627 West Main Street, Suite 223 Bozeman, MT 59715 Prepared by: May 2007 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 •P. O. Box 7021 • 25 N. Willson, Suite E • Bozeman, MT 59771 • • 406-587-8404 • Fax 406-582-1136 • www.gvlt.org • landtrust@gvlt.org • July 17, 2007 From: Ted Lange, GVLT Community Trails Program To: Lanette Windemaker, Bozeman Planning Department Subject: West Winds Phases 4-8 Mods to PUD #Z-07141 GVLT strongly recommends keeping the greenway trail corridor on the south side of Winter Park. This greeway will provide an important east-west connection from the Regional Park, to the West Winds park, to Rose Park to 19th. Keeping the greenway on the south side of Winter Park will allow bicyclists and pedestrians to access the Regional Park with the least possible number of street crossings. It is important to keep in mind that this greenway will also be part of a bicycle-pedestrian route to the new Chief Joseph Middle School. It will therefore be particularly important to ensure that the intersection of Vaquero, Davis and Winter Park is designed to be as safe as possible. Thank you for your consideration. Sincerely, Ted Lange, GVLT Community Trails Planner 314