Loading...
HomeMy WebLinkAboutL Street Structural Report L STREET, TURNER/GRIFFEN, AND HENDERSON STRUCTURAL BUILDING INSPECTION Story Mill Rd. and Griffen Dr. Bozeman, MT Ty Monks, Managing Principal, Montana P.E.#15860 August 31, 2012 NM No. 12044.01 Prepared for: The Trust for Public Land 111 South Grand Ave., Suite 203 Bozeman, MT 59715 Prepared by: Nishkian Monks, PLLC. 108 West Babcock St. Bozeman, MT 59715 406.582.9901 tel | 406.582.9992 fax TABLE OF CONTENTS Introduction .........................................................................................................................1 Limitations ..........................................................................................................................1 Background ......................................................................................................................... 1 Observations, Analysis, and Opinions ................................................................................1 Building “A”, L Street Parcel, Small Residence ....................................................2 Building “B”, L Street Parcel, Multi-unit Storage Facility .....................................2 Building “C”, L Street Parcel, Shop Building ........................................................3 Building “D”, L Street Parcel, Meat Processing/Slaughter House .........................3 Building “E”, Turner/Griffen Parcel, Storage Facility ...........................................4 Building “F”, Turner/Griffen Parcel, Accessory Dwelling ....................................4 Building “G”, Turner/Griffen Parcel, Residence ....................................................4 Building “H”, Turner/Griffen Parcel, Storage Facility ...........................................5 Building “I”, Turner/Griffen Parcel, Storage Barn / Accessory Dwelling .............5 Building “J”, Henderson Parcel, Residence ............................................................6 Building “K”, Henderson Parcel, Storage Barn ......................................................6 Conclusion .......................................................................................................................... 6 Evaluation Purpose .............................................................................................................7 Appendix Exhibits ..............................................................................................................8 Exhibit A – Story Mill Property Map Exhibit B – Story Mill Parcel Building Key Plan Exhibit C – Figures 108 West Babcock, Bozeman, MT. 59715 www.nishkian.com August 31, 20012 Mr. Alex Diekmann The Trust for Public Land 111 South Grand Ave., Suite 203 Bozeman, MT 59715 Re: Building Inspections of Structures on L Street Parcel, Turner/Griffen Parcel, and Henderson Parcel; Story Mill Property, Bozeman, Montana. Finalice Introduction As requested, our office conducted a structural review/inspection of the existing buildings currently occupying the L Street Parcel, Turner/Griffen Parcel, and Henderson Parcel within the Story Mill Historic District, located in the northeast corner of Bozeman, Montana. The scope of our inspection services included four structures on the L Street Parcel, 5 structures on the Turner/Griffen Parcel, and two structures on the Henderson Parcel (Appendix A, Story Mill Property aerial map). This report presents our findings and recommendations regarding structural damages on the subject buildings, as well as a short discussion on possible adaptive re-use suitable for the structures. Limitations Our professional services have been performed using that degree of care and skill ordinarily exercised, under similar circumstances, by reputable engineers practicing in the structural field in this or similar localities at this time. No other warranty, expressed or implied, is made as to the professional advice included in this report. This report has been prepared for the Trust for Public Land, and is intended to be used solely in its evaluation of the subject properties. The report has not been prepared for use by other parties and may not contain sufficient information for purposes of other parties or other uses. Background The scope of our inspection services included eleven structures on three separate parcels. The structures are separate buildings, varying in height and construction type. The identified structures in this report include commercial buildings, storage barns, and single-family residential buildings. This report presents our findings and recommendations regarding structural damages on the subject buildings, as well as a short discussion on possible adaptive re-use suitable for the structures. Observations, Analysis, and Opinions During the first two weeks of June 2012, Ty Monks and Tyler Hessler from our office conducted a site visit to the structures on the L Street Parcel, Turner/Griffin Parcel, and Henderson Parcel to inspect the buildings. The buildings were un-occupied, boarded up, and mostly without power. Hence, the visibility was limited to the illumination available through flashlights. Mr. Alex Diekmann Re: Building Inspection Mill Parcel, Bozeman July 23, 2012 2 Building “A”, L Street Parcel: A small residence, single story with covered entrance porch. The overall footprint of the building is approximately 33 feet by 22 feet. The building structural systems are as follows: 1. Foundation – Perimeter concrete strip footing with concrete stem wall allowing for standard crawl space access; 2. Walls – Standard light-framed wood stud (2x4’s @ 16”o.c.) construction; 3. Floors – 2 inch x 10 inch joists at 24 inches on center; 4. Roof – 2 inch x 6 inch rafters at 24 inches on center with plywood gusset rafter connection along ridge line. The small residence appears to be of sub-standard construction. The exterior wall joist size does not allow for the installation of adequate insulation thicknesses. Although the foundation system does not indicate any differential settlement, the floor diaphragm dips up to 1 inch in the corners of the rooms. The roof rafters have been connected with plywood gussets to create trusses that are questionable, especially considering the spans and spacing of its members. The front façade has partial height stone veneer supported by steel angles. The veneer shows no cracking and is in relative good condition. Giving it’s age and construction deficiencies, the building would need to be substantially renovated - both, structurally and architecturally – in order to re-occupied as a residence. Minor renovation might suffice if the building serves as a temporary shelter during the summer month. Building “B”, L Street Parcel: A multi-unit storage facility with garage door entrances to each unit. The overall footprint of the building is approximately 100 feet by 29 feet. The building structural systems are as follows: 5. Foundation – Perimeter concrete strip footing and interior spread footings; 6. Walls – Exterior walls are unreinforced concrete masonry units at the bottom 5 foot 3 inches and 2x4 stud framing on the top. Interior partition walls are standard light-framed wood stud construction; 7. Floors – Approximately 2/3 of the building has a concrete slab-on-grade, while the rest of the units have gravel flooring. 8. Roof – Flat roof with 10” deep metal rafters spanning between heavy gage multi joist steel beams supported on 4 inch square tube steel columns at a 14 foot by 16 foot grid. Generally, this utilitarian building was constructed per commonly used framing standards for storage facilities of similar size. Besides some differential foundation settlement below the exterior wall at the south/east rear corner of the building, the structure appears to be in excellent condition. The settlement occurs below a non-bearing wall and hence does not affect the overall stability of the building. However, we recommend that the settlement is being further investigated by a geotechnical engineer to determine if the close proximity of the building to the creek in the back of the building will not cause further foundation settlement in the future. Building “C”, L Street Parcel: A two-story shop building on the west side of the creek dividing the property. The overall footprint of the building is approximately 75 feet by 50 feet. The building structural systems are as follows: 1. Foundation – Perimeter concrete strip footing and interior spread footings; Mr. Alex Diekmann Re: Building Inspection Mill Parcel, Bozeman July 23, 2012 3 2. Walls - Constructed of concrete masonry units with undetermined reinforcement layout. The building has an open floor plan without any interior walls; 3. Floors – The ground floor has a concrete slab on grade, and upper level has an elevated concrete one-way slab. 4. Roof - Flat roof with wood rafters spanning between heavy timber beams supported by 8 inch square heavy timber wood posts. The shop building appears to have not been in use for any years. The lower level entrances to the building are heavily overgrown by vegetation and are difficult to open. There is an exterior wood framed stair leading to the upper level entrance door. The stair is on its verge to collapse and needs immediate replacement. The concrete floor slab at the upper level has cracks along the supporting beam lines. The types of floor cracks, however, are common in old structures due to concrete creep and/or foundation settlement. On the other hand, more concerning are the conditions of some of the concrete support columns. We’ve noticed spalling of concrete at the base of the columns, exposing reinforcement and hence compromising the stability of those columns. According to our visual review of the building, a structural rehabilitation must involve retrofitting the basement columns and foundations. The upper level, besides being littered with debris, is structurally salvageable. Building “D”, L Street Parcel: A meat processing/slaughter house with office spaces. The type of construction is reflective of the mid1900’s era. The overall footprint of the building is approximately 50 feet by 100 feet. The building structural systems are as follows: 1. Foundation – Perimeter and interior concrete strip footing with concrete stem walls elevating the building above grade; 2. Walls – Exterior walls are a combination of unreinforced multi-wythe brick masonry, concrete masonry block, and concrete. The interior walls are a combination of concrete and standard light-framed wood stud construction; 3. Floors – The ground floor is a concrete slab-on-grade at an elevated level compared to the exterior grade (approximately 3 foot). Interior open loft spaces and office partitions utilize wood diaphragms; 4. Roof – Flat roof with wood rafters spanning between heavy timber beams supported by interior walls or wood posts. Due to the combination of different construction methods and materials, it appears that this building has undergone several renovations/alterations with periodic additions being made to accommodate changing requirements for the building. Different settlement has occurred between the original structure and the additions, causing wall and foundation cracks. Furthermore, concrete columns in the partial basement on the east side of the building are heavily compromised by water damage. This part of the building needs to be entered with extreme caution, and shoring efforts need to proceed and type of reconstruction or remodeling in this part of the building. Sloping floors on the main level, at the north end of the building, were purposely installed to provide drainage during cleanup. Due to the incompatibility of the building additions to the original building, we would anticipate substantial structural mitigation work needs to occur. Mr. Alex Diekmann Re: Building Inspection Mill Parcel, Bozeman July 23, 2012 4 Building “E”, Turner/Griffen Parcel: A storage facility (pole barn) with garage door entrance and storage sheds on two sides of the building. The overall footprint of the building is approximately 62 feet by 40 feet. The building structural systems are as follows: 1. Foundation – Assumed turned down edge concrete slab perimeter footing; 2. Walls – Solid wood posts and multi-stud posts at 6 to 8 foot on center with horizontal 2x planks at 2 foot on center and sheathed with metal siding; 3. Floors – Concrete slab-on-grade; 4. Roof – Pre-engineered gang nailed wood trusses at 4 foot on center with 2x sleepers and metal roofing. The above described storage facility is in pristine condition with only minor dents in the exterior siding. No structural deficiencies were detected and the facility is ready to be used per its intended purpose. Building “F”, Turner/Griffen Parcel: A single-story, barn style, accessory dwelling unit with attic loft bedroom space. The overall footprint of the building is approximately 20 feet by 30 feet. The building structural systems are as follows: 1. Foundation – Concrete strip footing at the perimeter; 2. Walls – Standard wood stud framing with plastered exterior finish; 3. Floors – Assumed concrete slab-on-grade; 4. Roof – Stick framed roof with 2x6 rafters at 2 foot on center and metal roofing. The building is structurally sound, though we were unable to physically verify building member connections due to the applied finishes. The interior stairs and spaces (ceiling heights) do not appear to be code compliant and most likely would need to be reconfigured in order re-occupy this dwelling. Building “G”, Turner/Griffen Parcel: A single-story residence with attic living spaces and large backyard deck. The overall footprint of the building is approximately 40 feet by 30 feet. The building structural systems are as follows: 1. Foundation – Perimeter concrete strip footing with concrete stem wall allowing for standard crawl space access; 2. Walls – Standard light-framed wood stud (assumed 2x6’s @ 16”o.c.) construction with plastered exterior finish; 3. Floors – Assumed plywood over wood joists; 4. Roof – Pre-engineered gang-nail trusses and conventional stick framing with asphalt shingles. Since this building was completely secured and inaccessible, we were unable to inspect the interior spaces. However, the exterior of the building appeared to be in good structural condition with no visible cracking on any of the walls or foundations. The siding and fascia boards on the western façade of the building were extensively damaged by strong hail, possible allowing rainwater to penetrate and affect the framing. Mr. Alex Diekmann Re: Building Inspection Mill Parcel, Bozeman July 23, 2012 5 Building “H”, Turner/Griffen Parcel: A storage facility (pole barn) with garage door entrance and covered side deck. The overall footprint of the building is approximately 40 feet by 30 feet. The building structural systems are as follows: 1. Foundation – Assumed turned down edge concrete slab perimeter footing; 2. Walls – Preservative treated wood posts 10 foot on center with horizontal 2x planks at 2 foot on center and sheathed with metal siding; 3. Floors – Concrete slab-on-grade; 4. Roof – Plywood gusset plated wood trusses at 10 foot on center with 2x6 rafters at 2 foot on center and metal roofing. The above described storage facility is in good condition. No structural deficiencies were detected and the facility is ready to be used per its intended purpose. Building “I”, Turner/Griffen Parcel: A storage barn connected to a multi-unit accessory dwelling. The overall footprint of the building is approximately 120 feet by 25 feet. The building structural systems are as follows: 1. Foundation – Assumed turned down edge concrete slab perimeter footing at storage barn and strip footing at dwelling units; 2. Walls – Standard light-framed wood stud construction; 3. Floors – Slab-on-grade at storage barn and lower level dwelling unit, wood joist floor at elevated dwelling units; 4. Roof – Assumed stick framed pitched roof with metal roofing at the storage barn and asphalt shingles at the dwelling units. The dwelling units are structurally unsafe due to extensive dry rot, sub-standard construction, and under sized support members. It is our opinion that the dwelling units are uninhabitable and any repair efforts would be cost prohibitive. The storage barn may be saved and used per its intended purpose after only minor cleanup efforts. Building “J”, Henderson Parcel: A single-family residence with partial utility basement below kitchen area. The overall footprint of the building is approximately 30 feet by 56 feet. The building structural systems are as follows: 1. Foundation – Perimeter concrete strip footing with concrete stem wall allowing for standard crawl space access and concrete retaining walls at the utility basement; 2. Walls – Standard light-framed wood stud (2x6’s @ 16”o.c.) construction; 3. Floors – 2 inch x 8 inch joists at 16 inches on center; 4. Roof – 2 inch x 4 inch rafters at 24 inches on center. The residence appears to be of sub-standard construction. The vinyl exterior west facing siding was extensively damaged by strong hail, possible allowing rainwater to penetrate and affect the framing. The entrance hallway south of the kitchen slopes ½ inch per foot from side to side. The Mr. Alex Diekmann Re: Building Inspection Mill Parcel, Bozeman July 23, 2012 6 sloping of the hallway is caused by a rotation of the exterior wall footing supporting the hallway framing. This rotation is most likely due to unstable subgrade and needs to be addressed as soon as possible to control further damage to the building. Similar to our assessment of building “A”, considering the construction deficiencies, the building would need to be substantially renovated - both, structurally and architecturally – in order to be re-occupied as a residence. Building “K”, Henderson Parcel: A pole barn with a large barn door opening and clearstory openings above a center aisle space. The overall footprint of the building is approximately 60 feet by 110 feet. The building structural systems are as follows: 1. Foundation – Rubble; 2. Walls – Preservative treated wood posts 10 to 12 foot on center with horizontal 2x planks at 2 foot on center and sheathed with metal siding; 3. Floors – Mostly gravel with the exception of a 22 foot by 24 foot concrete slab-on-grade at the north/east corner of the barn; 4. Roof – Bolted wood trusses at 12 foot on center with 2x6 rafters at 2 foot on center and metal roofing. The pole barn shows no apparent structural concerns besides deflections of the roof trusses. The deflections in the trusses are most likely caused by slippage of the bottom chord’s central splice. It appears that the deflections have reach equilibrium and no further deflections can be expected. It is our opinion that the barn is structurally safe and ready to be used per its intended purpose. Conclusion Generally, the storage facilities and barn structures on the L Street, Turner/Griffen, and Henderson Parcel are constructed according to industry standards. Since these types of buildings are only temporarily occupied and mostly are designed to hold machinery or general storage items, the structures pose reduced risks to human lives. On the other hand, the residential buildings need to conform to stricter building code guidelines and provide certain comforts. Hence, the majority of the residential units did not fair as well and are probably not worth saving, unless ones expectations for these building are kept low or substantial improvements are budgetarily acceptable. The two heavy commercial buildings on the L Street Parcel, if historically significant, are structurally salvageable with moderate investments as long as no adaptive re-use changes the structural loading conditions. Evaluation Purpose The purpose of this report is to identify any structural damages to the subject properties. The report is not designed to evaluate the building for probable damage to the structure in the event of future strong ground shaking or other natural disasters. Hence, we did not base our findings on the type and quality of construction; configuration, age, and condition of the building; and its seismic-resistant system. This inspection was of a visual nature only. Every condition or potential structural condition may not have been noted. Observations made and probable conclusions reached were based on visual examination and evidence without the benefit of direct observation of some structural elements. In some cases, exact determination of workmanship and structural integrity cannot be made without destruction of interior or exterior finishes. Mr. Alex Diekmann Re: Building Inspection Mill Parcel, Bozeman July 23, 2012 7 Thank you very much for the opportunity to be of service. We trust the foregoing is adequate for your needs, but should you have additional questions please contact the undersigned. Very truly yours, NISHKIAN MONKS Tilden Monks, PE Managing Principal APPENDIX EXHIBITS Appendix  “C”:  Figures                                                                                   Fig.  2:  Crawl  space  entrance  at  the  back  of  the  building.   Fig.  1:  Front  view  of  L  Street  Parcel  Residence.                                                                                   Fig.  3:  Concrete  masonry  block  crawl  space  stem  walls.  No  attachment  of  floor  framing   to  foundation  wall.   Fig.  4:  Stacked  concrete  blocks  as  beam  support  with  no  connection  hardware.                                                                                               Fig.  5:  Exterior  view  of  brick  veneer.   Fig.  6:  Multi-­‐unit  storage  facility  on  L  Street  Parcel.                                                                                   Fig.  7:  Multi-­‐stub  steel  beam  connected  to  tube  steel  support  column.   Fig.  8:    Steel  deck  roofing  of  storage  facility.                                                                                                                         Fig.  9:  Foundation  wall  crack  at  south/west  corner  of  storage  facility.   Fig.  10:  Foundation  wall  crack  at  south/west  corner  of  storage  facility.                                                                                     Fig.  11:Exterior  view  of  L  Street  Parcel  shop  building.     Fig.  12:  Heavy  timber  beams  supported  on  timber  columns  at  the  upper  level  of  the   shop  building.                                                                                                                           Fig.  13:  Interior  of  upper  level  of  the  shop  building.   Fig.  14:  Concrete  slab  cracks  along  column  lines.                                                                                                                         Fig.  15:  Base  of  concrete  column  supporting  the  upper  level  of  the  shop  building.   Fig.  16:  Roof  trussed  area,  attic  space,  at  the  meat  processing/slaughter   house.                                                                                         Fig.  17:  Exterior  view  indicating  additions  to  the  building.   Fig.  18:  Wall  cracks  between  original  structure  and  addition.                                                                                       Fig.  19:  Wall  cracks  between  original  structure  and  addition.   Fig.  20:  Wall  cracks  between  original  structure  and  addition.                                                                                         Fig.  21:  Wall  cracks  between  original  structure  and  addition.   Fig.  22:  Basement  concrete  column  with  exposed  reinforcement  at  base.                                                                                       Fig.  23:  Basement  concrete  column  with  exposed  reinforcement  at  base.   Fig.  24:  Sloped  concrete  floor  for  drainage  during  cleanup.                                                                                     Fig.  25:  Exterior  view  of  storage  barn  at  Turner/Griffen  Parcel.   Fig.  26:  Exterior  view  of  storage  barn  at  Turner/Griffen  Parcel.                                                                                   Fig.  27:  Denting  of  exterior  siding.   Fig.  28:  Exterior  view  of  accessory  dwelling.                                                                                       Fig.  29:  Stairs  leading  up  to  loft  sleeping  area.   Fig.  30:  Residence  on  Turner/Griffen  Parcel.                                                                                     Fig.  31:  Pack  deck  entrance  of  residence.   Fig.  32:  Exterior  view  with  dormers  indicates  attic  living  spaces.                                                                                   Fig.  33:  Hail  damage  to  roof  fascia.   Fig.  34:  Hail  damage  to  plastered  wall.                                                                                       Fig.  35:  Hail  damage  to  trim  board.   Fig.  36:  Hail  damage  to  gutters.                                                                                   Fig.  37:  Exterior  view  of  second  storage  barn  on  Turner/Griffen  Parcel.   Fig.  38:  Interior  view  of  second  storage  barn  on  Turner/Griffen  Parcel.                                                                                   Fig.  39:  Interior  view  of  second  storage  barn  on  Turner/Griffen  Parcel.   Fig.  40:  Exterior  view  of  storage  barn  connected  to  multi-­‐unit  accessory  dwelling.                                                                                   Fig.  41:  Post  collapse  at  partial  basement.   Fig.  42:  Roof  shingles  in  disrepair.                                                                                   Fig.  44:  Interior  view  of  storage  barn.   Fig.  43:  View  of  front  of  dwelling  unit.                                                                                       Fig.  45:  Interior  view  of  storage  barn.   Fig.  46:  Exterior  view  of  residence  on  Henderson  Parcel.                                                                                     Fig.  47:  Utility  basement.   Fig.  48:  Interior  view  of  roof  framing  –  attic  space.                                                                                       Fig.  49:  Hail  damage  to  west  façade  of  residence.   Fig.  50:  Rotated  foundation  wall  at  exterior  of  hallway.                                                                                       Fig.  52:  Interior  view  of  pole  barn  on  Henderson  Parcel.   Fig.  51:  Exterior  view  of  pole  barn  on  Henderson  Parcel.                                                                                   Fig.  53:  Support  post  on  rubble  foundation.   Fig.  54:  Wood  trusses  with  deflection  of  bottom  chord.