HomeMy WebLinkAboutWhittier Elementary School ---- —� I Z
F NOTE: THE CONTRACTOR SHALL TAKE ALL MEASURES NECESSARY TO PROTECT THE EXISTING TREES
DURING CONSTRUCTION - AT THE CONCLUSION OF CONSTRUCTION, THE TREES WILL BE EXAMINED BY THE
2 CONTRACTOR AND SCHOOL DISTRICT REPRESENTATIVES. ALL TREES DAMAGED DURING CONSTRUCTION p o H. SHALL BE TREATED BY A LICENSED ARBORIST, AT THE CONTRACTOR'S EXPENSE.
FIRE LINE DETAIL — CLASS I SYSTEM
THE CONTRACTOR SHALL WARRANTY ANY TREATED TREES FOR ONE ADDITIONAL YEAR.
?zw w� z NOT TO SCALE
_` EAST WING WHITTIER ELEMENTARY SCHOOL w o DOUBLE CHECK VALVE ASSEMBLY SHALL MEET
COATED STEEL PLATE(MIN.14'XI4') THE FOLLOWING SPECIFICATIONS:
o m ❑v1 5 16'MIN.THICKNESS. A.UL OR FM LISTED.
TREE TO IT REMOVED AND DISPOSED /
wv B.APPROVED BY THE UNIVERSITY OF SOUTHERN CALIFORNIA
x > Z ��i ���I I OF OFF-SITE BY CONTRACTOR I S„ FOUNDATION FOR CROSS CONNECTION CONTROL AND
< I i CHAIN LINK FENCE TO BE REMOVED i �. 3/4'MIN.REDI ROD,INSTALLED IN HVDRAUUC RESEARCH(USCFCCCHR)FOR OPERATION IN
NOTE: CONCRETE STEPS DAMAGED DURING
BY CONTRACTOR AND REINSTALLED m> HALF OF THE AVAILABLE M.J.FLANGE THE HORIZONTAL POSITION.
< } u I I CONSTRUCTION SHALL BE REPAIRED OR (TYPICAL). C.SEE ITEM 10.2 OF THE CITY OF BOZEMAN FIRE SERVICE
> I F I REPLACED(AS DETERMINED BY THE SCHOOL DISTRICT) + m LINE STANDARD.
�O ? I Tc AFTER CONTRACTOR
A OF CONSTRUCTION BOLT HOLES TYPICAL.
Yi AT THE CONTRACTORS EXPENSE TYPICAL I ( ) o a FLANGE TO BE THREADED ON STANDPIPE.
I +g w I I r o M.J. TO FLANGE ADAPTERS NOT ACCEPTABLE.
< O O O I WEATHER STATION ON WOODEN POSTS
FIRE DEPARTMENT CONNECTION,
TO BE REMOVED BY CONTRACTOR PRIOR w INSTALL 4'D.I.PIPE AND
o IA n IF CONSTRUCTED,SHALL BE
_ 4'OSdeY VALVE- THIS PROJECT L.€ i V g�e�1 I ; €I aAi AFTERCSb�vEna+Ao�cirssi7RucnoN
a rt a < � < "-" DWBLE CHECK VALVE AND FLOW
Z Ilj BY OTHERS. INSTALLED DOWNSTREAM OF THE
I �� DETECTION DEVICE.
I V>� U Q R 3 KI W NO�h 1
\\
BY OTHERS.
GRINNELL CORP.,MODEL VSR-F,
L, \ I1 \ 1' TY 13.0' O FLOW DETECTION DEVICE
F I T TREES TO BE PROTEGiEO t 5{ 7 6.75• 2'MIN.CLEARANCE
I I � NEW C E r1 DURING CCNSTRUCTION r7 �a 99, 4'D.I.PIPE
CURB STOP U ,ry ABOVE FINISHED FLOOR OR APPROVED EQUAL
1.3'BACK OF S�o �C�- �T (' -
} \ -� _ PROPOSED IRON PIPE FIRE LINE ^
B +I FWNDAnON WALL
' I '/-.. F PROPOSED 2' VIC ky CITY) +
�UG�
cd
—GAS— o
f. ELEC TTED WRI S
—C—
z I y < w ,• �{ / \ \ z q�o z GENERAL NOTES
W SERV. I F i g I — — — — — — — ,f� SzI ��S
vd �� R3 sz 1. ALL CONSTRUCTION SHALL CONFORM TO THE ACCOMPANYING PLANS AND THE
/ I l.o �I F� I �fj SMALL cat+IFER0u5 TREES f�Y�ED BY Owr�ER Pelat 70 START .ON �Uc Etec, Is MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS, THIRD EDITION, OCTOBER, 1998,
-w sERv. I I N� y�b{o� II o' Nol zm ( c'� INDITE: THE CONTRACTOR sHAu cooaOwAmvs
TE w11H ---J �� 9w i AND THE CITY OF BOZEMAN MODIFICATIONS DATED MARCH, 1996.
THE CITY OF BOZEMAN WATER DEPARTMENT PER59NM1� \ I m�wo$1w o: 2. NO CHANGE OR MODIFICATION OF THE APPROVED PLANS AND
a col-" I �o oil oo J i TO INSTALL A NEW 2'DOMESTIC WATER SER IN THE \I�. (/ I g����� SPECIFICATIONS SHALL BE MADE WITHOUT THE PRIOR WRITTEN
1 5; :F I ( SAME TRENCH WITH THE NEW 4-FIRE UWE ` ~ ems APPROVAL OF THE ENGINEER AND THE CITY OF BOZEMAN
g� i > TREE TO REMAIN AND BE PROTECTED
W I �w� I F ably BY CONTRACTOR DURING CONSTRUCTION ) ENGINEERING DEPARTMENT.
�4' .3. PRIOR TO THE PRECONSTRUCTION MEETING, THE CONTRACTOR SHALL
I I < I ���& SUBMIT TO THE ENGINEER AND THE CITY OF BOZEMAN, WORKING DRAWINGS,
45 1 £Fora I Fx I L> SPECIFICATION SHEETS, ETC., FOR ALL EQUIPMENT AND MATERIALS TO BE
od "ww USED ON THE PROJECT.
I +� ) �wScs I / I INSTALLATION SHALL NOT BE MADE WITHOUT THE PRIOR WRITTEN
I I 2 I 1az�To I FINISHED FLOOR ELEV.-4777.32t APPROVAL OF ALL EQUIPMENT AND MATERIALS BY THE ENGINEER.
1 i�i ( / 1 4. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL BURIED
WEST WING WHITTIER ELEMENTARY SCHOOL UTILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION.
} \ 5. THE ENGINEER AND THE CITY OF BOZEMAN SHALL BE NOTIFIED AT
71 LEAST 24 HOURS PRIOR TO BEGINNING CONSTRUCTION.
7 6. MINIMUM COVER OVER THE WATER MAIN SHALL BE 6.5 FEET.
SIP A MINIMUM VERTICAL SEPARATION OF 1.5 FEET SHALL BE MAINTAINED
BETWEEN THE WATER MAIN AND ALL SEWER MAINS.
7. TYPE 1 OR TYPE 2 TRENCH EXCAVATION MAY BE USED AT THE
DISCRETION OF THE CONTRACTOR.
B. TRENCH BACKFILL SHALL BE T
9. BENCHMARK:SOUTH CAP FIRE HYDRANT BOLT ®SE CORNER OF INTERSECTION
OF PEACH STREET do N. 7th AVE., ELEVATION = 4779.223 (CITY B.M. #17)
10. IF CONSTRUCTION OCCURS WITHIN THE RIGHT-OF-WAY OF A DEDICATED
4778 4778 CITY STREET, A STREET CUT PERMIT SHALL BE OBTAINED FROM THE CITY NS FINISHED FLOOR STREET DEPARTMENT.
GJ EXISTING AND FUTURE GROUND SURFACE ELEV.-4777.32f 11. FIRE LINE INSTALLATION SHALL CONFORM WITH THE REQUIREMENTS OF
o -� THE CITY OF BOZEMAN FIRE SERVICE LINE STANDARD. THE 4" FIRE SERVICE LINE
INCLUDING THE OS&Y VALVE ARE TO BE INSTALLED AS PART OF THIS PROJECT.
I ( 12. ONLY FLANGED FITTINGS CAN BE USED ON THE FIRE SERVICE LINE INSIDE
4776 g� w 9: w 4776 OF THE BUILDING.
zm� I KI I 'd z �m 13. APPLICATIONS FOR THE FIRE SERVICE LINE AND THE 2" DOMESTIC WATER LINE MUST BE
o COMPLETED PRIOR TO INITIATION OF CONSTRUCTION. COST OF THE 2" BACKFLOW AND
a o h m W o s- W w READER WILL BE CHARGED TO THE SCHOOL DISTRICT OR APPLICANT FOR SERVICE AS
DETERMINED BY THE SCHOOL DISTRICT. THE CITY OF BOZEMAN WILL FURNISH ALL OTHER
4774 >< >_ - o �� vzF=rl_ �o ��g MATERIALS FOR THE NEW 2" SERVICE IN EXCHANGE FOR SHARING THE EXCAVATION.
iW z uFi �I Fp vFi ow-- 'd"�� 4774
Ek/ST)NCI �� I wW i�€i�i7msa
SPNALT j I Sa�i�o
i k'w AOE �' rc4 0
4772
td
gY���� 4772
LS' I STA 0+00 TO 0+24-INSTALLED 4'THICKNESS OF STYROFOAM 40 ~
F~ VI I BRAND HIGH LOAD INSULATION,OR EGUAL,6' BOVE WATER UNE. PIPELINE INSULATION
w♦j� 5.3' I BED IN MINIMUM OF 3.OF 3/4"MINUS CRUSH GRAVEL. (SEE 182t(TOTAL)LF.OF 4-CLASS 52 D.I.P.
4770
DETAIL THIS SHEET) bd NOT TO SCALE
--
I I 4770
T EXISTING 15'STORM —I.
I nW SEWER MAIN STORE ROOM FLOOR TRENCH BACKFILL III-NATIVE SOIL
jI )j ELEV. 4768.35t _-1
4768 1' I I 4'THICKNESS OF STYROFOAM , II
Wv7 4768 40 BRAND HIGH LOAD INSULATION. 20'
BED IN MINIMUM OF 3"OF 3/4"
MINUS CRUSHED GRAVEL. 3' MIN.
6"MIN
4766 \4- (TYPICAL)
4768 - - — 0 - - II
zm =m
NEW 2'WATER MAIN
NEW 4"D.I.P. WATER MAIN
4764 I o t o THIS CONTRACT io m (BY CITY)
+ 4764
MINIMUM
4762
-- — 4762
EXISTING 12"SANITARY ",w--• • t
RAY N. ?
SEWER MAIN CF.NTEu
AS-BUILT DRAWING : 56S3```
AUGUST 1997
0+00 0+50 1+00 1+50 2+00
-'zF-98
Rocky Mountain Engineers DESIGN BY:RWC/RHC DATE:
03/12/97 DRAWN RC Y: DATE:03/12/97 OR P1LAN VIEW: HORIZONTAL: 1" _
0 0 �3aC �4 REVISIONS: DATE: CHECKED BY: DATE: CONTOUR INTERVAL: 1'
a
p
Civil Engineering Land Surveying p1 - RWC 04/04/97AS-BUILT 09/10/97 RHC 03/14/97 PROFILE VIEW: HORIZONTAL: 1" 10'=
1700 West Koch Street, Suite 7, Bozeman, Montana 59715 (406)-586-4859 DRAWING FILENAME: /757-Whittler/firelhe.dlg 01/09/98 VERTICAL: 1" = 2' pdpp In pMI�mlg 93G1#1#4 Ll L( J