Loading...
HomeMy WebLinkAboutTripple T Woodworking Fire Line Plan I C E I F I ' I I I I <o zD D 10 zD 30 ha ''' I SCALE 1= 10 CONTOUR INTERVAL: 0.10 I I I I I ' LEGE D - �- UTILITY POLE 5 - -- - ._ 1+34.63 =_ - -. - - I - APPCAS uOCADON L , I =„--a° ,--<.o —°..— I i�ab AIN FIRE HYDRANT i - _ C • FOUND PROPERTY CORNER (n I - s i �• �I, 04 � OVERHEAD EAD POWER LINE I SETBACK N PROPERTY LINE LV f/ n«--n ry r-Ma.—n.—n r-n«--n�A--.-7'1.iG-.fi�n.-- n o n �-rt�n n n • 0 n� 0 1 4"FIRE UNE, / TAPPING SLEEVE WITH Z I I I THRUST BLOCK � 2'MIN I �r I CdBliIJCIpN ND7� I s16, EPARA110N BETWEEN / /Jr I G SEWER SERVICE ANO FRE SERVICE z v P.PPROX.LOCATION � 0F SEWER MAIN N j 1 O t. I S I i THIS � _AN COVERS THE FIRE SERVICE LINE I b j INSTALL.'Tf% TO THE OS&Y VALVE ONLY. 0 j EXISTING j I THE FIRE SUPPRESSION SYSTEM WILL NOT BE 4) z GAS LINE INSTALLED AT THIS TIME AND THE OS&Y W C I I VALVE WILL BE .'.EFT CLOSED. THE BACKFLOW p EXISTING �I j PREVENTER AND FLOW DETECTOR WILL BE m j — WATER UNE INSTALLED WHEN THE FIRE SUPPRESSION LL I— — — — — — —g — — — — — — — — — — — SYSTEM IS INSTALLED. ------ I 2 ALL WORK SHALL BE DONE ACCOL'DINC TO: MONTANA PUBLIC n A I I I WORKS STANDARD SPECIFICATIONS (VPWSS),FOURTH EDITION, z JANUARY 1996.; THE CITY OF BOZEMAN MODIFICATIONS TO MPWSS,FOURTH EDITION.MAY 1997;INCLUDING ADDENDUM'S N EXISTING 3/�I I .APPRO%.LOCATION1 No.1,2&3; THE CITY BOZEMAN FIRE SERVICE LINE m G - i WATER UNE I — — _ I IIOF 6'WATER MAIN STANDARD; AND NFPA 24 p 4) F I I 3 ANY EXISTING OR NEW VALVES WHICH CONTROL THE CITY OF Q a -.- -.--•--•- - CURB STT'� -- f�_ _ NS WATER SUPPLY ALL BE OPERATE[)BY THE CITY OF I ----- .--.--.- BOZEMAN PERSONNEL ONLY N N I BOZE .— —•--.--.-- — — —. -- -- — —_L._—.--.— ---. — — --_ -- --.--.—r —� _ --'-- - _ -1. 4. THE CONTRACTOR SHALL NOTIFY THE WATER DEPARTMENT A \ _ MINIMUM OF 24-HOURS PRIOR TO BEGINNING ANY WORK 5- CONTRACTOR SHALL INSTALL ADDITIONAL FITTINGS,BLOWOFFS,VALVES. - - - --- - - -- ---� — --- ETC. AS MAY BE NECESSARY TO ADEQUATELY FLUSH,TEST AND °pJ DISINFECT THE WATER LINES AND FITTINGS. 6- FIRE SERVICE UNE SHALL BE DISINFECTED ACCORDING TO SECTION 02713 MPWSS,THE CITY OF BOZEMAN MODIFICATIONS TO MPWSS- SAMPLES SHALL BE COLLECTED IN ACCORDANCE WITH AWWA STANDARD - --- - R771 HAWCE AVE de I i 7 FIRE SERVICE LINE SHALL BE PRESSURE TESTED AND FLUSHED IN �I ACCORDANCE WITH NFPA 24. $ 11 .I B. ALL PIPING AND VALVES WRAPPED IN 8 MIL POLYETHYLENE WRAP BRASS CONDUCTIVE WEDGES INSTALLEO ON ALL JOINTS AND FITTINGS,A MINIMUM OF THREE PER JOINT TO. FITTINGS SHALL BE RESTRAINED WITH MEGALUG MECHANICAL 400+39.38 1�00 G+50 0+004005 JOINT RESTRAINTS INSTALLED IN ACCORDANCE WITH --- -__ DETAL A NOTES 5 MANUFACTURES REQUIREMENTS CI z J NOTES 2, 3, 4 AND 10 L NOT APPLICABLE AT THIS PHASE OF CONSTRUCTION EXISTING STREET SURFACE -1'y SUBGRADE OR GROUND SURFACE 12 CITY OF BOZEMAN REQUIREMENTS FOR INSTALLATION OF O DOUBLE CHECK VALVE ASSEMBLY I. THE FIRST FITTING INSIDE OF THE BUILDING SHALL BE A _ LLL LISTED FLANGED KENNEDY OF MUELLER OS&Y VALVE THE SAME SIZE AS THE FIRE SERVICE UNE. VERTICAL TRENCH WALLS - /�ACK SLOPE AS REQUIRED WITH SHORING TO CONFORM ONFORM i0 OSHA REGULATIONS. TO OSHA REGULATIONS. E NOTE I BELOW FINISHED OADE SEE NOTE I BELOW ° TEMPORARY FITTINGS FOR FLUSHING - AND TESTING.REPLACE WITH BUND 4000 Q rn 4000 a \� 1(� ANGE WHEN 1ES11NG COMPLETE. .J.-.R-.-.-.-.-.-.-. / o TYPE'A'TRENCH BACKFlLL � UNDER ALL STREETS AND ROADS 2"FLUSHING PIPE 0 , TYPE"B"TRENCH BACKFlLL 2"BALL VALVE OUTSIDE OF ROADWAYS rc s o PRESSURE GAGE —SAMPUNG SPIGOTW� PIPE BEDDING IMPORTED 3/4' ■ ■ ■ I �J it tt z °i MINUS TYPE 1 BEDDING MATERIAL z ~ THRUST BLOCKED AND MEGAI.0 V j I o+o i F AS PER CITY OF BOZEMAN Q _ NO JOINT RESTRAINTS,ON PIPE. ---------------- F F` t0 2 JOINTS BETWEEN ELBOWS. RE54R"�"""r` R <-(� f-" MODIFICATION MPWSS 3995 z3995 PLACED IN 6"MAX LIFTS& EL 4'FLANGED 9G'ELBOW zo ; i O _ 4'CLASS 51 DUCTILE IRON PIPE — COMPACTED THOROUGHLY F � COATED STEEL WALL PLATE, I MIN. o -- m 2'MAX W 3 _ �- r TYPE 2 PIPE BEDDING REQUIRED FOR 5. HORIZONTAL INSTALLATION MUST BE A MINIMUM OF 2' 5/16"MIN,THICKNESS ✓� - - '-�"}" SOFT OR UNSTABLE FOUNDATION TYPE LE ABOVE THE FINISHED FLOOR. PROVIDE FLEXIBLE WATER-TIGHT " o o m - 2 PIPE BEDDING REQUIRES GEOTEX & �"CZ a a t�s FABRIC BETWEEN TRENCH SDEWALL& CONNECTION FOR ALL WALL OR " ° 4°FLANGED OS&Y VALVE 'ISS ST ad o IMPORTED BEDDING. MATERIAL PLACED 6 T FROM ANY OUTSIDE RISER WALL,IEASH AL BE A MINIMUM MINIMUM OF FLOOR PIPE PENETRATIONS. TO BE LEFT CLOSED OLCn<E/B o m IN 6°MA%LETS&COMPACTED OF V T!, .- �Y + + .� THOROUGHLY. DEPTH VARIES BUT FROM ANY INTERIOR WALL. 5/6"MIN REDI ROD INSTALLED IN 4� � MUST EXTEND TO SUITABLE BASE XIN HALF OF THE AVAILABLE BOI� FTHE INCOMING FIRE SERVICE LINE SHALL BE A MINIMUM HOLES(EVERY OTHER HOLE)/ REBBMME� ^9 '�'i-d t MATERIAL. POU FOR AS A SEPARATE 6.5', AND A MAXIMUM OF 7.5' BELOW FINISHED GRADE. -- BID ITEM AS OUTLINED IN SECTION 6'FLANGED PLAIN END SPOOL v`i 02230 MPWSS. C, 8. ALL FIRE SERVICE LINE APPURTENANCES SHALL HAVE A 3990 m DAT'39 ELEV TRENCH CONSTRUCTION NOTES-_ - -- MINIMUM PRESSURE RATING OF 175 psi. �I 3990 �I. 1. SEE OSHA CONSTRUCTION STANDARDS FOR EXCAVATIDN VA9. ALL FIRE SERVICE LINES 4°AND LARGER SHALL BE CLASS 51 DUCTILE IRON PIPE. - 2.DETAIL BASED ON FIGURE 02221-1 OF MECHAMCAL 1+39.38 1+00 0+50 o+Do A ROOM DETAIL B PROFILE VIEW C TAENCH DETAIL CITY OF BOZEMAN MOD FICAT ONS TO MPWSS SCALE: 3/4" = I' HORIZONTAL SCAL- 1" - 20' SCALE: 3/4" = V NOTES AND FIGURE BASED ON 02719-3 OFVERTICAL SCALE: T" - 2 CITY OF BOZEMAN MODIFICATIONS TO MPWSS RECORD DRAWING I