HomeMy WebLinkAboutOsterman - Fire Flow Water Modeling Vicinity Map BOZ S E ti�'-�- r \r' er
1 XA 31 \ - 2" WATER MAIN
eek
979 TpA�` r i ""•• - &T APPROX. EXISTING " FIRE SERVICE 1
PROJECT
SITE-APPROX. PROPOSED i
OSTERMAN-WAREHOUSES _ `�5'`�` - �- �'� ,4" FIRE SERVICE
—
7 -
l - -
{
8" WATER 1aAIN
Tr•,H/cr ( 1 is �■� •.i 1 � � � I
r
• vafA I 4168AT* =j l
IX + 1 �a`F9rvund Z
�- — fi + �•� �� ..tl .1 ti. u_ � 1 r ■ j E. BRYANT ST s
I fr . A tiles: 9�7Ei� \ �` I _ •
BOND ST
�•o 18" WATER MAIN
- _._- �(:' u uN sit^ i i■ ;ra s�l� 1 `� Pa.k� 7 4814 ' •_
k
I
- E
- - 4Si�9T Cary +\ \ `�-rk •� r
r48tid l p_ Af�S� -f-9
, uu --
I' - =__ Ire • �� r• f it 3 e _�� / ' 1 -� _IS sa
YAM _ .�♦ �l~ -
0 1000 2000 3000 0 150 300 450 SCALE (FEET) SCALE (FEET) A B v L T 9/O 4/ n/L
NO. REVISIONS DRAWN BY DATE PROJECT#: 12-026 SHEET
OSTE]LZMAN — ]FIRE FLOW WATER MODELING 32 DISCOVERY DRIVE Civil EngineeringDATE: 06/12/2012 ���
BOZEMAN,MT
59718 VICINITY
c•RaERc VICINITY MAP PHONE(406)582-022' Geotechnica Engineering gLL�ED
N..14—Pc FAX(406)5825770
Land Surveying ENGINEERING ; OSTERMAI>I
PROJECT ENGINEER:EDG DRAWN BY: RSR • www.allietlengineering.com y g
••F° B®ZEMAI�T,MOI�TTAI�TA .'"�.
DESIGNED BY: EDG, RSR REVIEWED BY: EDG 0j•...... VICIN=
EXISTING 4" DI CLASS 51
FIRE SERVICE LINE STA. 1+12.00
EXISTING 4" DI 90'VERTICAL BEND
& RISER, MJ W/MJR.
CONTRACTOR TO INSTALL ` FIRE LINE WILL
STA. 0+B5.00 THE FIRE SERVICE MUST BE INSTALLED BY
FLANGED OS&Y. PROVIDE FOR
TIE INTO EXISTING 4" DI 90'BEND SEE FIRE SPRINKLER DESIGN ONE CONTRACTOR FROM THE POINT OF PLANS FOR INFO CONNECTION UP T0, AND INCLUDING, THE CLASS I FIRE
SERVICE
BEYOND OS&Y VALVE. OS&Y VALVE IN THE BUILDING.
5 o THE ONLY FITTING ALLOWED BETWEEN THE
FIRST OS&Y VALVE AND THE BACKFLOW
ASSEMBLY IS A 90' BEND.
a
4" CLASS FLANGE TO BE THREADED ON STANDPIPE, M.J.
51 DUCTILE , TO FLANGE ADAPTORS NOT ACCEPTABLE
IRON PIPE
1" WATER SERVICE a (TYP.) 1.5' ABOVE FINISHED FLOOR
4" DI CLASS 51
FIRE SERVICE LINE
TO BE INSTALLED '}
STA. 0+21.00 4" CLASS 51
EXISTING CURB STOP TIE-IN TO EXISTING DUCTILE IRON PIPE
4" VALVE EXISTING 8" (TYP') 6.5' MIN.
SEWER MAIN COVER LEGEND
s s s s s s s s s E8=D47*v-
MAIN
OINTANICAL / " $FLANGED OS&Y VALVE
3 4 MIN. REDI ROD,
INSTALLED IN EVERY OTHER
THRUST BLOCK AT OF THE AVAILABLE M.J. BOLT
HOLES (TYPICAL) DOUBLE CHECK VALVE
M M M 88M M M M M M TEE TO BE VERIFIED MIN. REQUIREMENT)
90'BEND WITH THRUST BLOCK TO BE /AS INDICATED ON
STA. 0+00.00 TIE-IN TO EXISTING VERIFIED.
4" X 8" TEE 4 4" VALVE X APPROVED PLAN(S)
CONNECTION, MJ
PLA71N STEW-FIRE SERVICE LINE m ELEVATION-FIRE SERVICE LIME RISER(RIOT TO SCALE)
a
� CITY OF BOZEMAN REQUIREMENTS FOR
w r r w r w INSTALLATION OF DOUBLE CHECK VALVE ASSEMBLY
f O > > Z
1. THE FIRST FITTING INSIDE OF THE BUILDING SHALL BE A UL LISTED FLANGED KENNEDY
moo >000 '0O)nnli °�'oo OR MUELLER OS&Y VALVE THE SAME SIZE AS THE FIRE SERVICE LINE.
aoo a-o0 aL600 moo
on (Nnn Bonn `ten 2. ALL DOUBLE CHECK VALVE ASSEMBLISED SHALL BE:
co+a +aa co+aa +a A. UL OR FM LISTED.
F o II F o n g r o n n F u B. APPROVED BY THE UNIVERSITY OF SOUTHERN CALIFORNIA FOUNDATION FOR CROSS
X�> x rLni» x r» x r> CONNECTION CONTROL AND HYDRAULIC RESEARCH (USCFCCCHR) FOR OPERATION IN
w'wk wNzz w(011 WO THE PROPOSED POSITION (VERTICAL OR HORIZONTAL) AS SHOWN ON APPROVED
4720 4720 PLANS.
C. INSTALLED AS SHOWN ON THE APPROVED PLANS.
3. A FLOW DETECTION DEVICE SHALL BE INSTALLED IMMEDIATELY FOLLOWING THE DOUBLE
CHECK VALVE ASSEMBLY(ALARM CHECK VALVE, FLOW SENSOR/ALARM, METER, ETC.)
AS SHOWN ON THE APPROVED PLANS. PADDLE—TYPE FLOW ALARMS NOT PERMITTED
ON DRY SYSTEMS.
4. A DOUBLE DETECTOR CHECK VALVE ASSEMBLY MAY BE USED WITH A STANDARD CITY
FINISHED OF BOZEMAN METER. THE METER LOOP OF THE DOUBLE DETECTOR CHECK VALVE
PAVED LOT SHALL HAVE A DOUBLE CHECK VALVE ASSEMBLY INSTALLED WHICH MEETS THE SAME
INSTALLATION CRITERIA SPECIFIED ABOVE IN REQUIREMENT NUMBER TWO.
5. HORIZONTAL INSTALLATIONS MUST BE A MINIMUM OF 2' ABOVE THE FINISHED FLOOR.
471 715 6, THE FIRE SERVICE RISER MUST BE A MINIMUM OF 2' FROM ANY OUTSIDE WALL, AND
A MINIMUM OF 1' FROM ANY INTERIOR WALL.
7. THE INCOMING FIRE SERVICE LINE SHALL BE A MINIMUM 6.5', AND A MAXIMUM OF 7.5'
BELOW THE FINISHED GRADE.
S. ALL FIRE SERVICE LINE APPURTENANCES SHALL HAVE A MINIMUM PRESSURE RATING
6.5' MIN.
OF 175 PSI.
COVER 9. ALL FIRE SERVICE LINES 4" AND LARGER SHALL BE CLASS 51 DUCTILE IRON PIPE. pi
64 L.F. OF 4" DI 10. LINE SIZING: THE DOUBLE CHECK VALVE ASSEMBLY SHALL BE EQUAL IN SIZE TO -
CLASS 51 FIRE ERVICE THE OUTGOING PIPE DIAMETER (DOWNSTREAM).
TO BE INSTALLED
471 710
TIE—IN TO EXISTING
4" VALVE 27 L.F. OF EXISTING 4" DI
CLASS 51 FIRE SERVICE
470 707
3
N
Q o
�On ^
as ap
E
O N O N
+ + +
O O
PROFILE VIEW-FIRE SERVICE LINE AS-BUILT 9/0 4/12
NO. REVISIONS DRAWN BY DATE HORIZONTAL SCALE FEET VERTICAL SCALE FEET T PROJECT#: 08-138 SHEET
1 POST CLIENT MEETING RSR 06/01/2012 0 2C 4C 0 2 4 ®S°'�°E'RA�'1L�1`J MINI WAREHOUSE / / C-3
32 DISCOVERY DRIVE DATE: 06 12 2012
dm o. * BOZEMAN,MT 59718 Civil Engineering
oaae¢ao FIRE SERVICE ]SINE PHONE(406)582-0221 Geotechnical Engineering ALLIED
nw(aoe v[ FAX(406)5825770 Land Surveying ENGINEERING
PROJECT ENGINEER:SRS DRAWN BY: JAJ (, www.alliedengineering.com y g
0eg6° BOZEMAN MONTANA ��(NF )STERMAN MINI WAREHOUSE
DESIGNED BY: SRS, JAJ REVIEWED BY: SRS ' °j•.r.,v�°1°`�e FIRE SERVICE LINE
NOTE,' FIRE LINE WILL
THE FIRE SERVICE MUST BE INSTALLED BY PROVIDE FOR
ONE CONTRACTOR FROM THE POINT OF CLASS I FIRE
CONNECTION UP TO, AND INCLUDING, THE SERVICE
APPROXIMATE SEWER MAIN LOCATION OS&Y VALVE IN THE BUILDING.
—e S 9 $ S THE ONLY FITTING ALLOWED BETWEEN THE
FIRST OS&Y VALVE AND BACKFLOW
STA. 0+00.00 ® ASSEMBLY IS A 90' BEND.
EXISTING 8—IN WATER MAIN 4" x 8" TEE CONNECTION
TO EXISTING WATER MAIN FLANGE TO BE THREADED ON STANDPIPE, M.J.
W w w w w w w w 4" CLASS
w w w w w— 51 DUCTILE � TO FLANGE ADAPTORS NOT ACCEPTABLE
4—IN DI CLASS 51 IRON PIPE
w
FIRE SERVICE LINE 1.5' ABOVE FINISHED FLOOR
STA. 0+06.50
EXISTING BUILDING INV ELEV w 4708.17
4—IN DI GATE VALVE
4" CLASS 51 z
DUCTILE IRON PIPE w
(TYP-) LEGEND
8" D.I. MAIN MECHANICAL
INV ELEV N 4707.50 JOINT 3/4" MIN. REDI ROD, .$FLANGED OS&Y VALVE
THRUST BLOCK AT TEE �OF THE INSTALLEAVAILABLE D IN EVERY OTHERBOLT
HOLES (TYPICAL) DOUBLE CHECK VALVE
••,� MIN. REQUIREMENT)
STA. 0+20.69
4-IN DI 90'VERTICAL BEND. 90'BEND WITH THRUST BLOCK AS INDICATED ON
REFER TO DETAIL 1 ON THIS
SHEET FOR DETAILS. APPROVED PLAN(S)
4"X8" TEE 4 VALVE
NOTE:ALL ELEVATION DATA OBTAIN FROM ALLIED ELEVATION-FIRE SERVICE LINE RISER(RIOT TO SCALE)
ENGINEERING OSTERMAN MINI WAREHOUSE PLAN SET
DATED 1997. CITY OF BOZEMAN REQUIREMENTS FOR
INSTALLATION OF DOUBLE CHECK VALVE ASSEMBLY
FITTINGPLANT VIEW—FIRE SERVICE LINE1 REMUIELLER RST S&YIVAILDVE THE AMEOF THEISIZEGASHALL THE FRE SERVICE LLIINELANGED KENNEDY
2. ALL DOUBLE CHECK VALVE ASSEMBLISED SHALL BE:
A. UL OR FM LISTED.
B. APPROVED BY THE UNIVERSITY OF SOUTHERN CALIFORNIA FOUNDATION FOR CROSS
CONNECTION CONTROL AND HYDRAULIC RESEARCH (USCFCCCHR) FOR OPERATION IN
THE PROPOSED POSITION (VERTICAL OR HORIZONTAL) AS SHOWN ON APPROVED
PLANS.
C. INSTALLED AS SHOWN ON THE APPROVED PLANS.
3. A FLOW DETECTION DEVICE SHALL BE INSTALLED IMMEDIATELY FOLLOWING THE DOUBLE
CHECK VALVE ASSEMBLY(ALARM CHECK VALVE, FLOW SENSOR/ALARM, METER, ETC.)
AS SHOWN ON THE APPROVED PLANS. PADDLE-TYPE FLOW ALARMS NOT PERMITTED
ON DRY SYSTEMS.
4, A DOUBLE DETECTOR CHECK VALVE ASSEMBLY MAY BE USED WITH A STANDARD CITY
OF BOZEMAN METER. THE METER LOOP OF THE DOUBLE DETECTOR CHECK VALVE
SHALL HAVE A DOUBLE CHECK VALVE ASSEMBLY INSTALLED WHICH MEETS THE SAME
INSTALLATION CRITERIA SPECIFIED ABOVE IN REQUIREMENT NUMBER TWO.
4725 725 5. HORIZONTAL INSTALLATIONS MUST BE A MINIMUM OF 2' ABOVE THE FINISHED FLOOR.
6. THE FIRE SERVICE RISER MUST BE A MINIMUM OF 2' FROM ANY OUTSIDE WALL, AND
472 720 A MINIMUM OF 1' FROM ANY INTERIOR WALL.
APPROXIMATE EX TING GROUND 7. THE INCOMING FIRE SERVICE LINE SHALL BE A MINIMUM 6.5', AND A MAXIMUM OF 7.5'
471 715 BELOW THE FINISHED GRADE.
6.5-FT 8. ALL FIRE SERVICE LINE APPURTENANCES SHALL HAVE A MINIMUM PRESSURE RATING
CONNECT TO EXISTING 8-IN 471 COVER MIN 710
OF 175 PSI.
WATER MAIN WITH 4x8 TEE.
INV. ELEV. w 4707.5 4-IN 90'DI VERTICAL BEND. 9. ALL FIRE SERVICE LINES 4" AND LARGER SHALL BE CLASS 51 DUCTILE IRON PIPE.
470 705 STA. 0+20.69 -
INV ELEV- 4709.76 10. LINE SIZING: THE DOUBLE CHECK VALVE ASSEMBLY SHALL BE EQUAL IN SIZE TO
21 L.F. OF 4-IN THE OUTGOING PIPE DIAMETER (DOWNSTREAM).
DI CLASS 51 470 700
FIRE SERVICE STA. 0+06 0 _
INV ELEV 4708.17
4-IN DIG TE VALVE
p N
O �
PROFILE VIEW—FIRE SERVICE LINTE
3
E
AS BULT 9/04/12
NO. REVISIONS DRAWN BY DATE 0 10 20 30 # SHEET
FIRE
� SERVICE
�y7 BUILDING
1� 7�7 1p PROJECT 12-026
OSTERMAN1C'IRE SER V ICE � B�U ILDI1�1 G B 32 DISCOVERY DRIVE DATE: 06/12/2012 ��R
Civil Engineering
2
calk°. * BOZEMAN,MT 59718 g g
SCALE (FEET) Ua FIRE SERVICE PLC PROFILE � DETAILS PHONE(496)582-922 Geotechnical Engineering (A�LL,4—PE f PAX(406)s825770Land Surve in EEEPROJECT ENGINEER:EDG DRAWN BY: RSR www.allietlengineering.com y g aMmm OSTERMAN
;Ce BOZEMAN,MT
DESIGNED BY: EDG, RSR REVIEWED BY: EDG °j�e..,v.oY``« FIRE SERVICE