Loading...
HomeMy WebLinkAboutLongfellow Elementary School NOTE: ANY TREE ROOTS THAT HAVE TO BE REMOVED FOR INTLYSTALLATION OF THE SERVICE LINE SHALL BE T O OFATREESROOTST WILLDNOTIBE P RMITTEDG OR TEARING \ I FENCE CHAIN LINK t\ NOTE: C N7RAC�OR SHALL R LA ALL I SURFACES, HALT, ONCRETE, D LANDSCAPING. I > FIRE LINE DETAIL — CLASS I SYSTEM I DOUBLE CHECK VALVE ASSEMBLY SHALL MEET I THE FOLLOWING SPECIFICATIONS: COATED STEEL PLATE(MIN.14'%14') A.UL OR FM USTED. \ I / 5/16"MIN.THICKNESS. B.APPROVED BY THE UNIVERSITY OF SOUTHERN CALIFORNIA I FOUNDATION FOR CROSS CONNECTION CONTROL AND NOTE: THE CON ACTOR SHALL COOFt IN TE WAH 0 3/4'MIN.REDI ROD,INSTALLED IN HYDRAUUC RESEARCH(USCFCCCHR)FOR OPERATION IN THE CITY OF 80 MAN WATER DEPAR E T PERSONNEL HALF OF THE AVAILABLE M.J.FLANGE THE HORIZONTAL POSITION. TO INSTALL A NE 2'DO ES71C WATE RMC IN THE I BOLT HOLES(7WICAL). C.SEE ITEM 10.2 OF THE CITY OF BOZEMAN FIRE SERVICE Ei / LINE STANDARD. SAME TRENCH WI THE EW 4'FIRE IN. �I REMOVE AND REPLACE WOODEN APLl STA.0+66.2-END E SERNCE LINE FLANGE 70 BE THREADED ON STANDPIPE. SPLIT RAIL FENCE. - /� AT O.S.QY.VALVE(SE ETAIL THIS SHEET) _ M.J.TO FLANGE ADAPTERS NOT ACCEPTABLE. o FIRE DEPARTMENT CONNECTION, \ VERTICAL SAW C JEXIS�NG I / r -- INSTALL 4 D.I.PIPE AND EXPANSION I �� /( ' 4'OS@Y VALVE-THIS PROJECT IF CONSTRUCTED,SHALL BE EXPANSION JOINpWT(TYP) oCONCRETE EDGE / \ I}BY OTHERS. INSTALLEDDOWNSTREAM OF THE DOUBLE CHECK VALVE AND FLOW � � FINISHED DETECTION DENCE. FLOORYil 2"COPPER WATER I LEAN 4820.00 _ \\ SERVICE(BYZIITTY) i CURB STOP I - pU7 SS 0+40 0+ 0+8 2.0' '' BY OTHERS. - 0ICE +00 1.5' \ -I I 4.D7 / 1 2'MIN.CLEARANCE GR I NELL CORP.... MODEL VSR-F, \ T-----__r_____-_ INV.ROOF DRAIy 4"D.I.PIPE ^e ABOVE FINISHED FLOOR OR EQUAL. REPLACE ENTRANItE SIDEWALK i` FOUNDATION WALL — REPLACE 0+00 INSTAL 6'X4'TAP N SLEEVEAND \ I I 4"TAPPING ATE VANE W/THR T BLOCS AND _ VALVE BOX. THE 4"GATE VALVE ALL B RESTRAINED O THE E. ❑ rn / DIRT (j �`'_ WOODEN j FLOOR GENERAL NOTES SPLIT RAIL 4818.58 - �I�Call \ FENCE(TYP) 1. ALL CONSTRUCTION SHALL CONFORM TO THE ACCOMPANYING PLANS AND THE MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS, THIRD EDITION, OCTOBER, 1998, / AND THE CITY OF BOZEMAN MODIFICATIONS DATED MARCH, 1996. 4 2. NO CHANGE OR MODIFICATION OF THE APPROVED PLANS AND STA.-0+0 0+68 INS TA LED 4'THICKNESS OF 2 PCF SPECIFICATIONS SHALL BE MADE WITHOUT THE PRIOR WRITTEN SNO-FOAM LATIO 6"AB VE WATER LINE. BEDDED IN APPROVAL OF THE ENGINEER AND THE CITY OF BOZEMAN MINIMUM OF OF 3/4 MINUS CRUSHED GRAVEL. (SEE DET ENGINEERING DEPARTMENT. � THIS SHEET 3. PRIOR TO THE PRECONSTRUCTION MEETING, THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER AND THE CITY OF BOZEMAN, WORKING DRAWINGS, LONGFELLOW SCHOOL SPECIFICATION SHEETS, ETC., FOR ALL EQUIPMENT AND MATERIALS TO BE .�I USED ON THE PROJECT. INSTALLATION SHALL NOT BE MADE WITHOUT THE PRIOR WRITTEN APPROVAL OF ALL EQUIPMENT AND MATERIALS BY THE ENGINEER. 4. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL BURIED RE-LANDSCAPE AND SEED UTILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION. ROOF DRAIN EXPLORATION HOLE 5. THE ENGINEER AND THE CITY OF BOZEMAN SHALL BE NOTIFIED AT i LEAST 24 HOURS PRIOR TO BEGINNING CONSTRUCTION. ^ 6. MINIMUM COVER OVER THE WATER MAIN SHALL BE 6.5 FEET. A MINIMUM VERTICAL SEPARATION OF 1.5 FEET SHALL BE MAINTAINED BETWEEN THE WATER MAIN AND ALL SEWER MAINS. 7. TYPE IOR TYPE 2 OF THE TRENCH EXCAVATION MAY BE USED AT THE DISCRETION ❑ F 8. TRENCH BACKFILL SHALL BE TYPE A . 9. BENCHMARK:TOP CAP BOLT FIRE HYDRANT WEST SIDE OF SOUTH TRACY -- - --- AT ALDERSON EXTENDED. ELEVATION = 4834.37 ( CITY S.M.# 163) -- ----1.--- a632 10. IF CONSTRUCTION OCCURS WITHIN THE RIGHT-OF-WAY OF A DEDICATED II CITY STREET, A STREET CUT PERMIT SHALL BE OBTAINED FROM THE CITY II STREET DEPARTMENT. II 11. FIRE LINE INSTALLATION SHALL CONFORM WITH THE REQUIREMENTS OF IL_ _-_ THE CITY OF BOZEMAN FIRE SERVICE LINE STANDARD. THE 4" FIRE SERVICE LINE II ------- 4630 INCLUDING THE OS&Y VALVE ARE TO BE INSTALLED AS PART OF THIS PROJECT. -- II II 12. ONLY FLANGED FITTINGS CAN BE USED ON THE FIRE SERVICE LINE INSIDE II II OF THE BUILDING. II w II 13. APPLICATIONS FOR THE FIRE SERVICE LINE AND THE 2" DOMESTIC WATER LINE MUST BE FOUNDATION II ?'^ II COMPLETED PRIOR TO INITIATION OF CONSTRUCTION. COST OF THE 2" BACKFLOW AND WALL II �€ II READER WILL BE CHARGED TO THE SCHOOL DISTRICT OR APPLICANT FOR SERVICE AS 4628 - -- - �- - _ - ----_t -- - _--- - -- - -{ -28 DETERMINED BY THE SCHOOL DISTRICT. THE CITY OF BOZEMAN WILL FURNISH ALL OTHER EXISTIUTUR CAA AND EXISTING CURB FUTURE w< I I MATERIALS FOR THE NEW 2" SERVICE IN EXCHANGE FOR SHARING THE EXCAVATION. I I ut w I I AND GUTTER II w o II 4 w II w EXISTING ASPHALT 0 a s i STREET SURFACE - - 'mot I I I I 4826 a a - z - 4826 I w -I'~- W�a �Tm - _ y� EXISTING PIPELINE INSULATION —�SIDEWALK II ANCE i� II �✓ I ITOR'qRAGEI NOT TO SCALE z c'� a EXISTING I I Q o I.T. RAGE ROOK V'ia�u�i <rc�' SIDEWALK IF ha II 4824 - -_- �_�- __ _ _ _ _ 4824 STA.-0+02 � nm IT 6 , INST LED WATTH IK .SS OFD DE2 P NTON A SNO-FOAM ULA OV RLIN D IN BEDL. T L III III III NATIVE SOIL o MINIMUM OF 3-OF 3/4"MINUCRUSHED GRA E TRENCH BACKFILL THIS SHEET) m >aw c€i - 4"THICKNESS OF STYROFOAM 4822 f- o s-w F I NA .. --__ I - -� - 4822 40 BED IN MINIMUM OF BRAND FAD 3"IOFU3/4 IXJ. 2.0' _- R a F j i x. K I I MINUS CRUSHED GRAVEL. 3 MIN. Fz�3a g-oi a$�W o�ma C1A5552_-D.I.PIPE IIIII II _`4 6"MIN. L______�___ ____ ____ NEW 4'D.I.P.WATER MAIN N4820 4820 I EW 2" WATER MAIN ,.3' F O 6BiTOTAL L. THIS CONTRACT (BY CITY) 4818 3.5'MINIMUM 12'MIN. SEPARATION NOTE: ' E%ACT LOCATIONS OF RODF DRAIN AND i_XISTING SANIT IFFY +_ -. _ SANITARY$EWER SOM 4816 LINE . SEWER MAIN UNKNOWN. CONTRACTOLIF TO VERIFY THEIR LOCATIONS RELATIVE TO CONSTRUCTION PRIOR TC INSTALLATION OF FIRE LINE. j 'DOTE: FIEUD-F T NEW SERVICE TO MAINTAIN MNIMUM 6-1/2 FEET OF COVER. III` ALL CHANGES O BE APPROVED BY THE CITY BOZEMAN PRIOR TO CONST�CTION. AS-BUILT DRAWING o+oo o+zo 0+40 o+so AUGUST 1997 Rocky / ■O U n LA I I� E 1 1 g I I�V V S DESIGN BY: DATE: DRAWN BY: DATE: DRAWING SCALES: n n ° AOR/RHC 03/11/97 AOR 03/74/97 PLAN VIEW: HORIZONTAL: 1" oO = 10' ��,J VV ���OOI� REVISIONS: DATE: CHECKED BY: DATE: CONTOUR INTERVAL 1' u Civil Engineering & Land Surveying 4:< #1 - RWC 04/08/97 RHC 03/14/97 �300M4�] 4G3G^�C5'� C��G3C C��GIC O� g g y g �y AS-BUILT 08/13/97 PROFILE VIEW: HORIZONTAL: 1" = 10' Q 1700 West Koch Street, Suite 7, Bozeman, Montana 59715 (406)-586-4859 DRAWING FILENAME: /756FIRE.DWG 01/09/98 VERTICAL: 1" = 2' ' 00 L