Loading...
HomeMy WebLinkAboutLone Eagle Fire Line Plan NOTES la,9 11" DOMESTIC WATER a SERVICE, INSTALL I. All construction work on this project shall be completed In 3�i£ s ACCORDING TO C.O.B. w� accordance with Montano Public Works Standard Specifications, liv� J STD. DWG. 02719-6 J Fourth Edition. January, 1996 with May, 1997 C.O.B. �Sd Modifications to MPW w/ Addendums No. 1 & No. 2, City of �p a� STA 2+08.60 INSTALL Bozeman Fire Service Line Stwdord, and these Contract ? 90• BEND W/T.B. / Documents. CURB STOP - 2. The Contractor shall restore all roadway surfaces to equal, or better condition than existed prior to excavation and REMOVE EXISTING _ - determined by Owner and the Engineer. "" -2" BLOW OFF `�. = b, 4 3. The location, depth and size of existing utilities shown on - ''✓ iNSTALI 4" 11.25' BEND - � O - watF.!+_ 4' FlRE LINE 0 � � _ these plans is approximate. The Contractor shall verify the ((�3�, 2.50� 0 existence, location, depth and size of the utilities 14F V' - P Prior t s STA. 1+06.3 INSTALL (TY for T \ construction. The Contractor shall be solely responsible for f N 22.5' BEND W/T.B. - �O \ any damage to the existing facilities due to failure to locate STA. 0+00 INSTALL 60 them or properly protect them when their location is known. 3T L*ItiiiNi; 8" MJ GATE VALVE & DEP. � v,J415- 00c,0S 1 4. A list of representatives to contact for information - �(1 8"Y,4" REDUCER w/T.B. CONNECTION r�kpP P�. d ylC �� _ � ( ropose no Do 1�\ St OP\� GP`)P� ,a regarding facilities is oa follows: �J -- ( this submittgy'�" '` tiW�'a1. 0 C� -'� �-� -rn Montano One Coll System Dispatcher 1-800-424-5555 a Northwestern Energy Chuck Busto 582-4612 AT&T Cable Scott Riia 1-800-316-9644 ids OWEST Dave Smith 585-2350 INSTALL OS&Y % (Including Fiber Optics) + r o Oo STA. 0+03.00 INSTALL 0 VALVE 45' BEND W/T.B. - A. 2+78.29 INSTALL', j 5. All asphalt. concrete curbs and sidewalks shall be saw cut or neat cut b method approved b th n i e . Contractor ue E n e+ YY 9s N ✓ •� 9P BEND W/T.B. & � e /T obtain o Street Cut Permit from the City of Bozeman, MEGA-LUGS - o 6. All backflll for this project shall be Type A Trench BOCkAII, except � C / that the upper 2' In landscaped areas shall be Type B Trench m Z J STA 0+43.33 MAINTAIN '� �, /� / �- - Bockfill. o N m 1' VERTICAL SEPERATION S \, I _ 7. Maintain 11' horizontal and 18' vertical separation between 0 1 BETVEEEN SEWER & WATER. 's �` \ _ - water mains and all sanitary sewer mains. Full lengths of pipe o Q - CONTRACTOR SHALL VERIFY - \ - LONE EAGLE shall be centered at all crossings in compliance with W082 38.32 WATER & SEINER LINE DEPTHS \ `j 4" FIRE LINE & 1i" DOMESTIC WATER SERVICE and W091 8.6.3• PRIOR TO INSTALLATION OF \ ;��/ PROBABLE QUANTITY ESTIMATES EITHER LINE 8. All valves shall be installed with thrust blocking, and valve boxes in accordance with C.O.B. modifications and C.O.B. detail C ds, I_ INSTALL 4" CLASS 51 DUCTILE IRON PIPE 256 LF 2718_1_ m \ 2 INSTALL 1i" CORPORATION STOP 1 EA z � 9. All fillings including bends greater than 11-1/4 degrees, tees \\ \ 3. INSTALL It WATER SERVICE 260 LF and plugs shall be thrust blocked In conformance with C.0.8. $No 4. INSTALL 4 917 BEND 2 EA Modifications and MPW detail 2713-1. Re 5. INSTALL 4" OS&Y FL X FL VALVE AND ASSEMBLY 1 EA S= r�S 10. 4" fire service line shall be Installed in accordance with C.O.B.�s --�� 20' P.U.E. \ 6. INSTALL 8'X4" REDUCER I EA Fire Service Line Standard. These plans are for construction GAS. ELEC. CATV - 7. INSTALL 4" 22.5• BEND 1 EA U \ of the 1;" domestic water service and a 4" fire service from ,� ' 8. INSTALL 4" 11.25' BEND 1 �' the existing C.O.B. B" main to the OS&Y valve In the building. E 9. INSTALL 8" MJ GATE VALVE I EA See Architec turd/Mechanical plans for fire service line beyond this point. r \ Ler 11. The fire service line shall be Inaldlled, chlorinated and tested to ajr minimum of 200 psi by a single Contractor. Morrison-Maierle, Inc 04 3" GRAPHIC SCALE w o - shall provide construction observation and prepare the record 0 m drawings. < IN y6CT 1 12. City of Bozeman to operate all valves and shall make top of I laeb' 20 rE existing 8" main, Contractor shall expose main, provide and = I install topping tee and valve. 13. The City of Bozeman Woter Deportment will install 1" domestic k NOTE: FIRE LINE CONTRACTOR CONSTRUCTED AND TESTED wale, service from main to the curb slop ut the owner's expense AGAINST A FLANGE PRIOR TO INSTALLATION OF OS&Y 14. Datum used is the City of Bozeman datum. VALVE. 15. A preconslruction conference shall be required prior to the start of construction. No changes may be made to these plans without the approval of the City of Bozeman Water/Sewer Superintendent. - 16. All estimated quantities are approximate and are to be used s 's ��n??�r "���"��'�� only o as a basis for estimating the probable cost of the work PP-SCALE Y O 9 = � $n"OED Ossv VALVE and (b) for the purpose of comparing the bids submitted for the HORIZ 1 ZO' z o ,,,, •..n�., o work. The actual amounts o1 work done and materials furnished a7w3n,"� 00!reli aetx`9r) under unit rice Items may differ from the estimated ontitias. u m o -- VERT. - - 5' da6s $w.awn P r w "AA�awss s' §a 6413c♦1m os 17. A pressure lest must be performed on the existing 8" stub nor A12111 11 ruafs) P P 9 P IN ALL OS&Y -;.- _., , .- -,, to the Installation of the fire service line. This is to verify that - -<. - the existing 8" valve will hold. A new 8" valve will be required if I VALVE o -s "I�' °1" the existing valve does not hold pressure. Z JowFINISHED FL - 4860 "'v"-I B0V 1 t1n' 1 16. Mega-lug or approved equal restraints shall be used on all bends. Z so tyro-rr♦nus macs Z r 19. Griffin Pipe's Field Lok 350 Gaskets or approved equal shall be O used on all pipe connections 5' from building and under building. TAI*M TU a VALVE. err a IatayM Iar reVU/.tlox a FINISHED GRADE EXISTI WALL oORioOVAL WME♦wt VE N 4855 ran wi rmt COarqupl ) rn.nm nerve.rW r Y.wylny our r.u we wgne ' 9p w -- - - - W -- - -- -- - - rwvr.n.rr mw..♦.wow.yw.na M rs.r OAK ST. on,♦r o.r wr a�+e♦.rr r � LL v h Vint 0 S. a wwwW,w wwwwy a sow,.,,[wrnr r«ne.r„w r,� O 5 68% 0.00x nWO[R nExaL Crox oA. w,wr r r♦�•yt i...a. W a r•♦n w w war .wry w r�M �209-- - - - - �. - - - = 1.81 _ ,^ ran ALL w ex n.orar .do`s yr.r a w.row..P_ J u 4850 oat no4Tanors > r.•a..♦.,yww ..Mryr rn.n.asy or•4 w C.7 16 - swai.wn.ww. 7«wn ar e♦.,rr/w.w. Q o� INSTAL RISER IN w r-•�.w♦y....vey.-ton sr rm ACCOR CE WITH <ra� DURSTON RD. W Z g oe,ar pawrw a.a r,w. „4 r r.w,•annenre MAINTAIN 6.5' MINIMUM C C.O.B. . DWG. ;::rr `uXs sr....•rw, n.n.ew n.� a.,ar awnr,ar + rr♦.w•sow rawer vr.. nr.rr yvm w.rr W d o 02719-3 4845 �"°'r'r"'�'•'"r r•wawnw,a r.nw+w rear r W . - - - - - - - - -_.-__-__ _ - - _ -_ ___ __ � + ♦ a.rr�.r we•r r n•aw..,,a Y own.nr=wra.+. _J J ::-I. i � .,ran.,,a r'roan wv.•.r..♦ resew w r8♦.l..ei,.w.,y'iwrw.yrs r.new,,.,,e.e'..e.,,.,... U.S. 191 w lY A eExo ors a n`"asr`o"nx r"•••rev err nw..nwrwwn�,.. W MAIN ST _ J 4840 � o. r r.rs re.•.r rs.r r o�er veer rn ro.. 'fit 4i elaac � Q r0.UAL yMr eve rraY err ww.rynnM y♦ wow w rs a I- W,w Y,m.Y1 rnl•Mr(MW�n)i,.yy�p r0• "• F K Z m N 'ww .a.'u•�Ma tievY rw m ? h--r'w_r .e.�.. L� Sr:�� 2 a z m "!3 U.S. 191 COLLEGE ST. cZa - -"+{� r4835 +v m r nK aiia+alc ±�s�.+� r .'RIFFINE LN. m^l r.1 0 e <b N m i \ e� Aewc rar�En noon m rn m RF.S ARCH DR MSU P(tOJECf Nil. 4830 PROJECT 3495,001.020.0310 - CITY OF BOZEMAN SCALE: STANDARD FIRE SERVICE Nil. evised 3 LINCOLN RD. GRANT ST u ,n Y M po al W o± m 01 0 - NONE LINE INSTALLATION Revised SHEET NW/BER g STANDARD DRAITINC raA CLASS 1, n,t III SYSTEMS 1 o 0 0_ pp o�p Jan. 2DDD AREA r e W a�1 cp �W y ♦N 10 < - ORAYnNO NUMBER ed //n\\MI p/ �I�\\p�I f�1� 0n50 1+00 1+I50 - -- - - --- 2+00 2+50 -- -- - FREC0RD_ DFRR%A 11 � V�� VICINITY N�TO��