Loading...
HomeMy WebLinkAboutGallatin Center Lot 9.1 AFTER NEW LINE IS TESTED AND ACCEPTED BY CITY, CLOSE VALVE, REMOVE EXISTING WATER LINE, - INSTALL PLUG AFTER REMOVE ABANDONED WATER - INSTALL CAP, AND REMOVE REMOVAL OF EXISTING MAIN AFTER NEW LINE HAS VALVE BOX. ENSURE EXISTING '8" WATER MAIN [BEEN TESTED AND ACCEPTED VALVE IS RESTRAINED TO BY CITY. L _ EXISTING TEE PRIOR TO K --- - -- - - -1-•-_ - - - - - - - -I REMOVAL OF EXTISTING 8" REBAR ANCHOR EXISTING iJ. ! WATER LINE. IF NOT \ THRUST BLOCK DIMENSIONS 30LLaRJS RESTRAIN PER COB STD DWG FIRE HYDRANT o va. T00 PSI 150 PSI 20v PS 250 PS, 300 PSI I N0. 02713-1 AND 02718-1. s,:o s- A B C A B I C A B C Aj-0j2'-m012'-0"2'-0* A B C STA. 0+00 - z-o•x-0 2-o z o'x-o z'-o•r o'r-r z o z-0 '-o•r o'x'-�'/? / POTHOLE AND VERIFY LOCATION 2 z'-o'2-or-o a2-6 2'-0 2 9 x-6-2-6'J o - J'o J'-oAND ELEVATION OF EXISTING WATER t.'^ C 1 2 2-3.2-o z'o 3'0 3-0 2'-6 3 s•3'-o-S-0•.J '-r 3'-o 15+01.53 MAIN PRIOR TO CONSTRUCTION. °" 1 14" 2'-3•2 o s'-o Y-5 3-0 3'0 4 6'J o-s o'4-o '-9 4'o 4-o'CONNECT NEW MAIN TO EXISTING /` 1 8 16 Y-T r-o Y-o 4.4 3'-o r o 4-r4•-o-4'o's 6'-r r o+-o•5+01.53 "POTHOLE AND VERIFY WATER MAIN W/8" DI GATE VALVE. 1/4 1 r-s-3'-o J'-o s'-s 3- 4-0'6-. s-9 s-o s'-o•4+45 ( ) LOCATION AND ELEVATON OF - -� NOTE PRESSURES SHOWNoABOVE ARE MAXIMUM WORKING PRESSURESIN SYSTEM. EXISTING WATER MAIN PRIOR 8"X6"STEE MJ W/MJR TO CONSTRUCTION. CONNECT CONCRETE/ THRUST BLOCKING AND ANCHORS ARE REQUIRED ON ALL 6" VALVES AND NEW MAIN TO EXISTING " _ ANCHORS WATER MAIN W/8" DI GATE 00 0 LARGER UNLESS SPECIFIED BY THE ENGINEER 6" GATE VALVE UG 1Q I 8" "A" AND PLUG VALVE 4+42 r 1 DETAIL STA. 4+H9- A I NOTE: COAT RODS WITH "KOPPERS" BITUMASTIC NO. 50 COATING OR EQUAL. 1.5" WS - TYPE "K" COPPER, 15 LF I EXISTING THRUST BLOCKING FOR WATER MAIN VALVES -W/CURBSTOP AT EASEMENT LINE FIRE HYDRANT C.O.B. STD DETAIL NO. 02718-1 PER COB STANDARDS. [� r UNDISTURBED EARTH (TYP.) 0 0 0 CONCRETE THRUST ' ", r 30' WATER MJ GLAND NEW 8" DI CLASS 51 a MAIN EASEMENT BLOCK (TYP.) �,;,.•". �:", GENERAL NOTES: L - - - . _ . . - .WATER MAIN . _ . . _ . . � _\ MJ GLAND 1. ALL MATERIALS AND WORKMANSHIP SHALL 8" DI TEE, MJ 8" DI TEE, MJ STA. 4+08.67 STA. 0+61.62 •" CONFORM TO MONTANA ADDS PUBLIC WORKS STANDARDS, STA.8" ENDCAP, W/8" ENDCAP, D.I. MJ D.I. ® D.I. 4TH EDITION AND ADDENDUM p2 WITH CITY OF MJ W/ MJR MJ W/MJR PIPE TEE PIPE O PIPE gppROVEDOZEMANMB DITIHE T UNLESS ENG ENGINEER CONSTRUCTIONSHALL --- - BE DONE BETWEEN 8:00 A.M. AND 5:00 P.M., MONDAY THROUGH FRIDAY. MJ VALVE 2. CONTRACTOR SHALL FIELD VERIFY LOCATION AND DEPTH OF ALL EXISTING UTILITIES WHERE NEW WATER MAIN-PLAN D.I. FACILITIES CROSS OR CONNECT. CONTRACTOR NOTE: MJ GLAND PIPE SHALL BE RESPONSIBLE FOR EXPOSING POTENTIAL UTILITY FARAHEAD OF INSTALL JOINT CON RUCOTIONC O TS MAKEENOUGH NECESSARY GRADE MODIFICATIONS WITHOUT DELAYING THE WORK. ALL RESTRAINTS WITHIN 40' 3/4- MIN. CORROSION RESISTANT ALL THREAD UTILITY CROSSINGS SHALL POTHOLED RI NECESSARY PRIOR TO EXCAVATING OR BORING TO RESTRAINING ROD, CONFORMING TO ASTM A242-81, ALLOW THE CONTRACTOR TO PREVENT GRADE OR OF ALL FITTINGS. O INSTALLED IN HALF THE AVAILABLE MECHANICAL JOINT ALIGNMENT CONFLICTS. MJ VALVE BOLT HOLES (TYP.) WHERE NECESSARY, CLAMPING LUGS (ROMAC "DUCTILE LUG" OR EQUAL) DESIGNED 3. CONTRACTOR SHALL ERECT AND MAINTAIN TO FIT DUCTILE IRON (D.I.) PIPE, AND CONFORMING BARRICADES, WARNING SIGNS, AND TRAFFIC CONES TO ASTM 536-80 MAY BE USED IN CONJUNCTION PER CITY AND MDT REQUIREMENTS IN ACCORDANCE MJ GLAND WITH THE RESTRAINING RODS. WITH THE MUTCD (INCLUDING MONTANA D.I. AMENDMENTS). ALL TRAFFIC CONTROL MEASURES PIPE MECHANICAL JOINT RESTRAINT DEVICES (MEGALUGS) SHALL BE APPROVED AND IN PLACE PRIOR TO ANY 3 MAY BE USED IN LIEU OF CONCRETE THRUST BLOCKING. CONSTRUCTION ACTIVITY. z 4. AT LEAST 2 BUT NOT MORE THAN 10 BUSINESS r 2 DETAIL DAYS BEFORE BEGINNING ANY EXCAVATION, THE TYPICAL VALVE/TEE RESTRAINT CONTRACTOR SHALL, ACCORDING TO MCA 69-4-501, < C.O.B. STD DETAIL NO. 02718-8 NOTIFY ALL OWNERS OF UNDERGROUND FACILITIES co a � AND COORDINATE THE WORK WITH THE OWNERS OF o SUBGRADE OR GROUND Ma, ' SURFACE SUCH UNDERGROUND FACILITIES. THE INFORMATION SHOWN OR INDICATED IN THE CONTRACT DOCUMENTS m w WITH RESPECT TO EXISTING UNDERGROUND FACILITIES IS BASED ON INFORMATION AND DATA OBTAINED II w o II w II FROM THE OWNERS OF THE FACILITIES WITHOUT 4695.0 O+ z �+ + + 4695.0 FIELD EXPLORATION, AND AS SUCH, OWNER AND zy 5 < o � wow, ENGINEER ARE NOT RESPONSIBLE FOR THE z Q I N d y" a z z a n y ACCURACY OR COMPLETENESS OF SUCH �- a z m u�i z o~z< 4690.0 INSTALL DETECTABLE 4690.0 r,y? ao y_ y- INFORMATION OR DATA. WARNING TAPE 18" (45CM) STOCKPILES (TO MAX. DEPTH (OPTIONAL) BE REMOVED) 4685.0 TYPE "B", OR "C' 5. PIPE BEDDING AND @gQKF111 ALL PIPES SHALL 4685.0 i. - TRENCH BACKFILL BE BEDDED WITH MINIMUM 4-INCHES OF TYPE 1 FINISH GRADE PIPE BEDDING AND BACKFILLED WITH THE SAME FINISH GRADE \ i \ EXISTING GROUND MATERIAL A MINIMUM OF 6-INCHES OVER THE TOP 4680.0 / �� i \\ 4680.0 SLOPING, BENCHING OR OF THE PIPE PER CITY OF BOZEMAN STANDARD -------- - \-- -------- SUPPORT SYSTEMS IN THIS DETAIL 02221-1. --- --- -- -- - -- 4675.0 -- 6.5' 4675.0 AREA TO CONFORM TO MIN. COVER O.S.H.A. REGULATIONS' 6. CONTRACTOR SHALL PROVIDE ALL MATERIALS, EQUIPMENT AND FACILITIES REQUIRED FOR TESTING ALL UTILITY PIPING IN ACCORDANCE WITH CITY 4670.0 4670.0 SELECT TYPE I BEDDING 6"(15CM) INITIALO RAND ORETESTINGCSHALLSBE COST BORNEFBY ALL THE MATERIAL PLACED IN 6"(15CM) 4665.0 502 LF OF 8 DI CLASS 51 WATER MAIN LAYERS AND COMPACTED AS- I 4665.0 SPECIFIED IN SECTION 0222E � - CONTRACTOR. TYPE I BEDDING PLACED �i 7. NO TRENCHES IN ROADS OR DRIVEWAYS SHALL < < IN 6" (15CM) MAX. LAYERS ---4"(10CM) BE LEFT IN H OPEN CONDITION OVERNIGHT. ALL AND COMPACTED THOROUGHLY. SUCH TRENCHES SHALL BE CLOSED BEFORE THE i*} -� END OF EACH WORK DAY AND NORMAL TRAFFIC FLOWS RESTORED. 0 0 0 0 0 0 0 0 0 0 o WATE TRENCH WIDTH= 1 TYPE 2 PIPE BEDDING _ 0 voi 0 Ln 0 N 0 9 0 0 0 WHERE REQUIRED FOR �{ O.D. OF PIPE + 2' �-- 8. CITY FORCES TO OPERATE ALL VALVES, v+i a a n n N N - ± o+ o SOFT OR UNSTABLE FOUNDATION MIN. TRENCH WIDTH=3.5' INCLUDING FIRE HYDRANTS, ON EXISTING PUBLIC MAINS. -SEE O.S.H.A. CONSTRUCTION STANDARDS FOR EXCAVATIONS. 9. ALL WATER MAINS 12" DIAMETER AND SMALLER s WATER MAIN-PROFILE SHALL BE CLASS 51 DUCTILE IRON. ALL WATER = 3 DETAIL MAINS AND SERVICES TO BE INSTALLED NTH A MINIMUM 6.5' OF COVER TO FINISH GRADE UNLESS TYPICAL UTILITY TRENCH OTHERWISE NOTED OR DIRECTED. C.O.B. STD DETAIL NO. 02221-1 AS-QUILT NO. REVISIONS DRAWN BY DATE HORIZONTAL SCALE VERTICAL SCALE NTq r LOT PROJECT ': 01-245 SHEET EVISED/ADDED SERVICES CGB 2/6/03 0 30 60 0 10 20 q GALLATIN CENTER T 9.1 32 DISCOVERY DRIVE DATE: FEB., 2003 Wl 1 AS-BUILT cBH s/ze/o3 /pR,9 ,,.. Civil Engineering �/�/ OF WATER MAIN DESIGN LL_ PHONE(40BOZEMAN MT 59721 W1-RELOCATION ',sd6l� Land Surveying SCALE VERIFICATION-BAR EQUALS 1 INCH '� PHONE(406)582-0221 LOT 9.1 °°25 ALLIED Geotechnical En ineerin BOZEMAN MT ENGINEERING g g FAX(406)582-5770 PROJECT ENGINEER: CGB DRAWN BY: GBH WATER MAIN DESIGNED BY: CGB REVIEWED BY: CGB c° 1 cEs,wc.