HomeMy WebLinkAboutFront St - Water Main Extension -P,. '?.,e9- ///=;Ate• -./,f ZZL
/.AND T./RI/_1T ALOCK. ._^_ AS-Su/LTDE7A/.L
R� A/ R/�Wr.� Dc'TA 'L
STA. O,Jo - CO,+PICCr /✓Ew \
4"'J.r. WA TEA'• MAI,✓ TO EX
6 WATER MAIN W/NL'W1`-
37A. 0.00 rc 0♦/S- /NSrAt 45 T1 PROV/Oe M/N./B-
5rPARArIIW O Ex1Sr///6 =/V/ -SPwER. SerQ-
�
,SrA, I.S B
r-413 - /145TALL 4"• CvA, �-'.�� 0.P:` -? 5r32 - 7J//'E A Bq Cr:�I:_ ' _ 's �•G/ /
VAL Ve AIAP TA/RT BLOCK GENERAL/ �� n ec ioz z• /
GENERAL NOTES
�I�w \ \ _S6•s' / 1. All construction shall conform to the accompanying plans and
.9 specifications prepared by Rocky Mountain Engineers.
2. No change or modification of the approved plans and specifications
a shall be made without the prior written approval of the Engineer
1 !I. �oX Ce / o \ and the City of Bozeman Engineering Department.
H \ 3. Prior to construction, the Contractor shall submit to the
•h Engineer, working drawings, specifications sheets, etc., for all
equipment and materials to be used on the project. Installation
/ ;• /c,= X shall not be made without the prior written approval of all
equipment and materials by the Engineer.
4. The Contractor shall verify the location of all buried utilities
I 11 41 �+X ` ` ` prior to beginning construction.
\ Y 5. The Engineer and the City of Bozeman shall be notified at least 48
N., 1 hours prior to beginning construction.
X ;o 6. Minimum cover over the water main shall be 6.5 feet.
i u44^eE/✓o 7. Benchmark: Ci
ty of Bozeman Benchmark Y535. Center nut on top of
A/✓ N _D PJ - - fire hydrant, southwest corner of No. Broadway and Front St.
Elevation x 4757.22
/ 5-A_ 5- -'�..� '!• �,A. wATrR SER✓,CE.
B. Pressure and leakage tests, as well as chlorination of the new
gy, \ water main, shall be performed with potable water using clean
_VLO ,�cyo Sp �'� TA. 6,1 - //y5'ALL L"- Tee, 9 /.F containers and piping. The containers, piping, and other
' ' f4,e 1 e.. o-Z. VAi S9 MAI,, t192 appurtenances used to introduce water or chlorine into the main
>< p GATE ✓A,-✓C, A,ID THRUST Ca.[+CK`. ?.-4_- shall be clean, and shall not have previously contained
BA1
STA b+zz - ;Ns-AI a'GA-E v,+_ve pesticides, fuels, or other chemicals that would contaminate the
7-Ia1tT a Ju. Public water supply.
IV AMP
57-A. 6.32 - /VISTA, o""f'L IIG M/O
STA 4,18- It SPe/R TRACK. / I 1 THRUST BLOCK Ai eN0 OF WATER MAIN.
N i I I Ve- WA7ER L/NE SNAGi. SE
N5•uE OF CASING4.-
Z O TN/CK,/C35 O./OB.N.) (A•r16 ^CIE- A,. re•
g W i,+ SNAI-•L B! I/JSTALLCO UNDER SrI„� R�, \ A5-BU/�•T
d S WRAC[ av 51R/NG !/R -Ai.IC//✓6,
z i :: ARE MADe
w'T,I 14aAlrA/JA IVAI4 <I/1K_
LEGEND Rocky Mountain Engineers
O 1. P.O. Box 853, Bozanm,Montana 59771
0 (406)566-49W
KD O W -W-- WATER LINE
0 l 45 _ss_ _ SEWER LINE PROJECT: WA7EA'. Mq/N EXTENSION
R 0 E FRONT 3T - s-5s -r. �A,Asr
040 O OVEItNEAO ELECTRIC uNES DESIGN BY: DATE: DRAWN BY: DATE:
tiI E_- UNDERGROUND ELECTRIC R'NG a-Z3-91 X (_ 9---9)
0 25 50 100 f C) / I G -0 GAS LINE ~ REVISIONS DATE CHECKED BY: DATE:
r 9-Za 9/
Q _ 1,
5. T T UNDERGROUND TELEPHONE
4nSCALE: 1'�50' / — �+- `q4 - - � �.
•
it
14
EIN
- • _ t -
o - - -
-
nU(GN
V I - -
71
g - - _ - - -- -
di i - -- - -- - 474
V.
O I'00 /"o 2.00 S+00 40.00 yw00 br00
-KlUrr �t■altiR PLATE I,PLAN-PROFILE
44M4MW4in U.6A.•