Loading...
HomeMy WebLinkAboutSouth Towne Square Serendipity Medical Clinic Conditional Use Permit, 280 West Kagy Boulevard, Application Z-130 Commission Memorandum REPORT TO: Honorable Mayor and City Commission FROM: Brian Krueger, Associate Planner Steve Worthington, Interim Planning Director SUBJECT: South Towne Square Serendipity Medical Clinic Conditional Use Permit Application #Z-13002 MEETING DATE: February 25, 2013 AGENDA ITEM TYPE: Action-Quasi Judicial RECOMMENDATION: That the City Commission approves the Conditional Use Permit Application for the Serendipity Medical Clinic #Z-13002 with the conditions and code provisions and findings within the staff report. RECOMMENDED MOTION: “Having reviewed the application materials, considered public comment, and considered all of the information presented, I hereby adopt the findings presented in the staff report for application #Z-13002 and move to approve the conditional use permit with conditions and subject to all applicable code provisions” BACKGROUND: Property owner 3S Properties, LLC; applicant Sarah Hill; and representative Redleaf Consulting, PLLC have submitted a conditional use permit application requesting to allow an optometrist office and accessory retail sales on the ground floor of the building at 280 West Kagy Boulevard in the South Towne Square development. A conditional use permit is required for a medical clinic on the ground floor of a building in the B-1, Neighborhood Business zoning district. Other uses in the building include a restaurant; dry cleaners pick up and drop off service; and a medical clinic on the second floor of the building. No exterior alterations are proposed to the building or to the site. Two public comments have been submitted to date in support of the application. UNRESOLVED ISSUES: None at this time. ALTERNATIVES: 1. Approve the application with the Staff conditions; 2. Approve the application with modifications to the Staff conditions; 3. Deny the application based on a finding of non-compliance with applicable criteria; 4. Open and continue the public hearing on the application, with specific direction to Staff or the applicant to supply additional information. FISCAL EFFECTS: No significant fiscal effect has been identified. 203 Attachments: Staff Report, Applicant’s submittal materials The full application and file of record can be viewed at the Planning Department at 20 E. Olive Street. Report compiled on: February 14, 2013 204 #Z-13002 South Towne Square Serendipity Medical Clinic CUP Staff Report 1 City Commission Staff Report for South Towne Square Serendipity Medical Clinic CUP File #Z-13002 Item: A Conditional Use Permit Application to allow Serendipity Medical Clinic to operate on the ground floor within South Towne Square and the B-1, Neighborhood Business District at 280 West Kagy Boulevard Suite B, Owner: 3S Properties, LLC 3138 Madrona Lane Bozeman, MT 59715 Applicant: Sarah Hill 1028 Hunters Way Bozeman, MT 59718 Representative: Readleaf Consulting, PLLC PO Box 161085 Big Sky, MT 59716 Date: City Commission Meeting February 25, 2013 at 6:00 p.m., in the City Commission Meeting Room, Bozeman City Hall, 121 North Rouse Avenue, Bozeman, Montana. Report By: Brian Krueger, Associate Planner Recommendation: Conditional Approval ______________________________________________________________________________ Project Location The property is located at 280 W. Kagy, Suite B and legally described as Lot 3A, Amended Plat of the rearrangement of Thompson’s Addition, City of Bozeman, Gallatin County, Montana. The zoning designation for said property is B-1 (Neighborhood Business District).Please see the following vicinity map. 205 #Z-13002 South Towne Square Serendipity Medical Clinic CUP Staff Report 2 Proposal This application is to allow an optometrist office and accessory retail sales on the ground floor of the building at 280 West Kagy Boulevard. A conditional use permit is required for a medical clinic on the ground floor of a building in the B-1 zoning district. Other uses in the building include a restaurant; dry cleaners pick up and drop off service; and a medical clinic on the second floor of the building. The South Towne Square site development was approved by the City Commission in 2007. The entitlement includes five buildings, 103 parking spaces, common spaces, and site improvements. To date three buildings have been constructed along W. Kagy Boulevard (Buildings 1-3) and one foundation has been constructed along South 3rd. Avenue (Building 4). Building 5 located to the interior of the lot has not been constructed. The developer and owner’s association of the South Towne Square received planning approval in the summer of 2012 to eliminate building pad 5 and reconfigure the parking and circulation area to accommodate approximately forty more parking spaces on site. The construction of this project is anticipated in spring of 2013. South Towne Square has an approved offsite parking agreement with Pilgrim Church on South 3rd Avenue in the amount of forty offsite spaces. The existing South Towne Square is conforming to the zoning ordinance in regards to site improvements and parking. On January 30, 2013 the Development Review Committee recommended conditional approval of this Conditional Use Permit application and their recommended conditions, code citations and comments are included in this report. Recommended Conditions of Approval Based on the subsequent analysis, the Development Review Committee and Staff find that the application, with conditions and code provisions, is in general compliance with the adopted Growth Policy and the City of Bozeman Unified Development Code. The following conditions of approval are recommended. Please note that these conditions are in addition to the required code provisions beginning on page 5 of this report. Planning Department Recommended Conditions: 1. The long term, offsite parking lease agreement shall be maintained until such time that the additional parking improvements are made to the South Towne Square site as approved in zoning application #Z- 07051D. 2. Any expansion of this use or facility is not permitted unless reviewed and approved as required under the applicable regulations of the Bozeman Municipal Code. Conclusion/Recommendation The Development Review Committee and Staff have reviewed the South Towne Square Serendipity Medical Clinic Conditional Use Permit and recommends to the City Commission approval of said application with the conditions and code provisions outlined in this staff report. Staff has identified various code provisions that are currently not met by this application. Some or all of these items are listed in the findings of this staff report. The applicant must comply with all provisions of the Bozeman Unified Development Code, which are applicable to this project, prior to receiving Final Plan approval. The applicant is advised that unmet code provisions, or code provisions that are not specifically listed as conditions of approval, does not, in any way, create a waiver or other relaxation of the lawful requirements of the Bozeman Municipal Code or State law. Zoning Designation & Land Uses The property is zoned B-1 (Neighborhood Business District). The intent of the B-1 district is to provide for smaller scale retail and service activities frequently required by neighborhood residents on a day to day basis, as well as residential development as a secondary purpose, while still maintaining compatibility with adjacent residential land uses. Development scale and pedestrian orientation are important elements of this district. 206 #Z-13002 South Towne Square Serendipity Medical Clinic CUP Staff Report 3 The following land uses and zoning are adjacent to the subject property (the overall South Towne Square property): North: Commercial use, zoned “B-1” (Neighborhood Business District) South: Residential use, zoned “R-1” (Residential Single Household Low Density District) East: Residential use, zoned “R-1” West: Vacant, unannexed County land Adopted Growth Policy Designation The Future Land Use Map of the recently updated Bozeman Community Plan designates the subject property to develop as “Community Commercial Mixed Use”. (Note: Previously this site was designated as “Neighborhood Commercial”). Activities within the Community Commercial Mixed Use category are the basic employment and services necessary for a vibrant community. Establishments located within these categories draw from the community as a whole for their employee and customer base and are sized accordingly. A broad range of functions including retail, education, professional and personal services, offices, residences, and general service activities typify this designation…The Community Commercial Mixed Use category is distributed at two different scales to serve different purposes. Large Community Commercial Mixed Use areas are significant in size and are activity centers for an area of several square miles surrounding them. These are intended to service the larger community as well as adjacent neighborhoods and are typically distributed on a one mile radius. Smaller Community Commercial areas are usually in the 10- 15 acre size range and are intended to provide primarily local service to an area of approximately one-half mile radius. These commercial centers support and help give identity to individual neighborhoods by providing a visible and distinctive focal point. They should typically be located on one or two quadrants of intersections of arterials and/or collectors. Although a broad range of uses may be appropriate in both types of locations the size and scale is to be smaller within the local service placements. Mixed use areas should be developed in an integrated, pedestrian friendly manner and should not be overly dominated by any single land use. Higher intensity employment and residential uses are encouraged in the core of the area or adjacent to significant streets and intersections. As needed, building height transitions should be provided to be compatible with adjacent development. Review Criteria & Staff findings Section 38.19.110.E “Review Authority Consideration and Findings for Conditional Use Permits” In addition to the review criteria below, the City Commission shall, in approving a conditional use permit, find favorably as follows: 1. That the site for the proposed use is adequate in size and topography to accommodate such use, and all yards, spaces, walls and fences, parking, loading and landscaping are adequate to properly relate such use with the land and uses in the vicinity. South Towne Square is an existing successful neighborhood business node. The site is functioning without significant complaints and staff has not identified any public health and safety issues related to the addition of a small medical clinic on the ground floor of one of the buildings on site. With the previous addition of formal off-site parking and the anticipated parking lot reconfiguration in the spring of 2013 the project will continue to be in compliance with the parking requirements for this proposal and the existing and future building 4 uses. The site is in general conformance with the site plan approved in 2007 by the City Commission and is anticipated to be reconfigured to provide more onsite parking and functionality per the approved modification application #Z-07051D. Conditions are proposed for the application that will keep the development conforming to parking requirements. The three existing Conditional Use Permits for on premise alcohol consumption and one for outdoor seating are in conformance with their conditions of approval and staff is not aware of any complaints that have been received by the City in relation to alcohol consumption or outdoor seating at South Towne Square. 207 #Z-13002 South Towne Square Serendipity Medical Clinic CUP Staff Report 4 2. That the proposed use will have no material adverse effect upon the abutting property. Persons objecting to the recommendations of review bodies carry the burden of proof. The proposed medical clinic is small scale with two exam rooms and two physicians working at the office. The total office space is proposed at approximately 1,500 square feet with approximately 485 square feet of that area dedicated to retail sales. The retail portion of the clinic is located adjacent to the primary pedestrian ways and parking area and will not impact the retail and service environment at South Towne Square. This optometrist’s office provides a specialty in pediatric services and includes general service to the community. This use will be complimentary to Acorn Pediatrics medical office located on the second floor of the subject building and will likely be utilized by patrons making other trips to businesses within South Towne Square. This is consistent for the vision of a neighborhood business district with diverse, but compatible and complimentary uses. Staff has received two public comments as of the writing of this report. The two comments are supportive of the proposed medical office and one letter specifically addresses the compatibility of the proposed optometrist office with Acorn Pediatrics on the second floor of the building. Any public comment received after the completion of the Commission packets will be distributed to the Commission members at the public hearing. Following review of the proposed application with the inclusion of the recommended conditions, staff finds that the proposed use will have no material adverse effect upon abutting properties unless evidence presented at the public hearing proves otherwise. 3. That any additional conditions stated in the approval are deemed necessary to protect the public health, safety and general welfare. Such conditions may include, but are not limited to: regulation of use; special yards, spaces and buffers; special fences, solid fences and walls; surfacing of parking areas; requiring street, service road or alley dedications and improvements or appropriate bonds; regulation of points of vehicular ingress and egress; regulation of signs; requiring maintenance of the grounds; regulation of noise, vibrations and odors; regulation of hours for certain activities; time period within which the proposed use shall be developed; duration of use; requiring the dedication of access rights; other such conditions as will make possible the development of the City in an orderly and efficient manner. Staff has identified, through the review process, recommended project conditions that are included to protect the public health, safety, and general welfare. Please see the recommended conditions of approval and findings within this report. Section 38.19.100A “Plan Review Criteria” In considering applications for site plan approval under this title, the Planning Director, City Commission, Development Review Committee, and when appropriate, the Administrative Design Review Staff, the Design Review Board or Wetland Review Board shall consider the following: 1. Conformance to and consistency with the City’s adopted growth policy The development proposal is in conformance with the Bozeman Community Plan including the Community Commercial Mixed Use land use designation. The medical office will add vitality to this existing development that is a focal point on the south side of Bozeman. Based upon the review of this specific site and context, the proposed use and building are in conformance with the Community Commercial Mixed Use land use classification. 2. Conformance to this title, including the cessation of any current violations The applicant is advised that unmet code provisions, or code provisions that are not specifically listed as conditions of approval, does not, in any way, create a waiver or other relaxation of the lawful requirements of the Bozeman Municipal Code or state law. The following code provisions must be addressed prior to Final Site Plan approval: 208 #Z-13002 South Towne Square Serendipity Medical Clinic CUP Staff Report 5 a. In Accordance with the BMC Section 13.12.322 the Water/Sewer Superintendent is requiring an inspection of your water service to determine whether the water service has backflow protection and if such protection is installed that the device is appropriate for the level of use for the facility. If the service has been found without backflow protection the applicant will have a preventer and expansion tank installed. If the existing device does not provide adequate protection, the applicant will be required to replace the preventer with a preventer that is designed to provide adequate protection. Please call the Water Department’s Backflow specialist @ 582‐3200 to arrange an inspection of the water service. b. Section 38.19.110.F BMC states that the right to a conditional use permit shall be contingent upon the fulfillment of all general and special conditions imposed by the Conditional Use Permit procedure. All special conditions and code provisions shall constitute restrictions running with the land, shall be binding upon the owner of the land, his successors or assigns, shall be consented to in writing by the applicant prior to commencement of the use and shall be recorded as such with the Gallatin County Clerk and Recorder’s Office by the property owner prior to the final site plan approval or commencement of the use. All of the conditions and code provisions specifically stated under any conditional use listed in this title shall apply and be adhered to by the owner of the land, successor or assigns. c. Section 38.19.110.I. BMC Termination/ Revocation of Conditional Use Permit approval: 1. Conditional use permits are approved based on an analysis of current local circumstances and regulatory requirements. Over time these things may change and the use may no longer be appropriate to a location. A conditional use permit will be considered as terminated and of no further effect if: a. After having been commenced, the approved use is not actively conducted on the site for a period of two continuous calendar years; b. Final zoning approval to reuse the property for another principal or conditional use is granted; c. The use or development of the site is not begun within the time limits of the final site plan approval in Section 38.19.130, BMC. 2. A conditional use which has terminated may be reestablished on a site by either, the review and approval of a new conditional use permit application, or a determination by the Planning Director that the local circumstances and regulatory requirements are essentially the same as at the time of the original approval. A denial of renewal by the Planning Director may not be appealed. If the Planning Director determines that the conditional use permit may be renewed on a site then any conditions of approval of the original conditional use permit are also renewed. 3. If activity begins for which a conditional use permit has been given final approval, all activities must comply with any conditions of approval or code requirements. Should there be a failure to maintain compliance the City may revoke the approval through the procedures outlined in Section 38.34.160, BMC. d. Section 38.19.120A states that no later than six months after the date of approval of a preliminary plan, the applicant shall submit to the planning department a final plan with accompanying application form and review fee. The final plan application should include a narrative describing how the conditions of approval and code provisions have been met. e. Section 38.19.160 states that a Building Permit must be obtained prior to the work, and must be obtained within one year of Final Plan approval. 3. Conformance with all other applicable laws, ordinances, and regulations The Final Plan will be reviewed to ensure compliance with this section. The plans will be further evaluated against the requirements of the International Building Code at the time application is made for a Building Permit if required. 4. Relationship of site plan elements to conditions both on and off the property Existing- The subject property is developed with three of the five mixed use commercial buildings 209 #Z-13002 South Towne Square Serendipity Medical Clinic CUP Staff Report 6 entitled for the site. The buildings constructed to date are located along the West Kagy Boulevard street frontage. Site access and parking exists for the entire development as well as pedestrian sidewalks on the interior and exterior of the site. The primary entrances to the site are from South 3rd Avenue and W. Kagy Boulevard. No on street parking exists along the project public street frontages. A Streamline transit stop is located within the development along W. Kagy Boulevard. A residential neighborhood zoned R-1, Residential Single Household Low Density, is located to the south and east of the project site. The Figgins Creek watercourse, riparian, and trail corridor are located between the residential neighborhood and the development on the project site. The developer and owner’s association of the South Towne Square received planning approval in the summer of 2012 to eliminate building pad 5 and reconfigure the parking and circulation area to accommodate approximately forty more parking spaces on site. The construction of this project is anticipated in spring of 2013. South Towne Square has an approved offsite parking agreement with Pilgrim Church on South 3rd Avenue in the amount of forty offsite spaces. The existing South Towne Square is conforming to the zoning ordinance in regards to site improvements and parking. Proposed- The proposal includes the addition of one small scale medical office use on the ground floor of the building at 280 West Kagy Boulevard. No changes to the building or the site are proposed. 5. The impact of the proposal on the existing and anticipated traffic and parking conditions No additional parking is required as part of this application. Parking for this medical office has been reviewed and is consistent with the parking requirements and the existing parking available for South Towne Square. The traffic generation is within the scope and limits of that analyzed with the original site development and no additional traffic mitigation was identified. 6. Pedestrian and vehicular ingress and egress Vehicular access to the site will not be modified. Pedestrian ingress and egress is proposed to remain unchanged. The site is considered a conforming site plan under the original building approval. 7. Landscaping, including the enhancement of buildings, the appearance of vehicular use, open space, and pedestrian areas, and the preservation or replacement of natural vegetation No modifications to the existing landscaping or streetscape are required or proposed as part of this application. 8. Open space No change to the approved open space is proposed. 9. Building location and height No physical alterations are proposed to the exterior of the building. The location and building height will remain unchanged. 10. Setbacks The site plan to construct the building at 280 West Kagy Boulevard was reviewed for compliance with setbacks, no changes are proposed. 11. Lighting No changes to lighting are proposed as part of this application. 12. Provisions for utilities, including efficient public services and facilities No changes to the sewer and water connections or private utilities are proposed. 13. Site surface drainage No changes to the site surface drainage are proposed. 210 #Z-13002 South Towne Square Serendipity Medical Clinic CUP Staff Report 7 14. Loading and unloading areas No alterations are proposed that would impact loading and unloading areas. 15. Grading No new grading is anticipated on site. 16. Signage No signage is requested as part of this application. A sign permit will be required for any new signage. 17. Screening No screening is requested or required with this application. 18. Overlay district provisions Not applicable. This site is not located within an Overlay District. 19. Other related matters, including relevant comment from affected parties Staff has received two public comments as of the writing of this report. The two comments are supportive of the proposed medical office and one letter specifically addresses the compatibility of the proposed optometrist office with Acorn Pediatrics on the second floor of the building. Any public comment received after the completion of the Commission packets will be distributed to the Commission members at the public hearing. 20. If the development includes multiple lots that are interdependent for circulation or other means of addressing requirement of this title, whether the lots are either: Configured so that the sale of individual lots will not alter the approved configuration or use of the property or cause the development to become nonconforming or; The subject of reciprocal and perpetual easements or other agreements to which the City is a party so that the sale of individual lots will not cause one or more elements of the development to become nonconforming. Not applicable, the proposed development is on one lot and part of a conforming unified development. 21. Compliance with article 8 of chapter 10 of this Code This project is not subject to workforce housing requirements. 22. Phasing of development This project is proposed to be completed in one phase. Attachments: Applicant’s Submittal Materials Public Comment Report Sent to: Owner: 3S Properties, LLC 3138 Madrona Lane Bozeman, MT 59715 Applicant: Sarah Hill 1028 Hunters Way Bozeman, MT 59718 Representative: Readleaf Consulting, PLLC PO Box 161085 Big Sky, MT 59716 211 212 213 Page 1 of 4 Conditional Use Permit For S.E.E. Serendipity Eyecare + Eyewear Dr. Sarah Hill Dr. Sarah Kirkpatrick EXECUTIVE SUMMARY: This report presents the Conditional Use Permit (CUP) application for 280 W. Kagy, Condo B, South Towne Square, Bozeman, MT 59715. The request of this CUP is to permit the use of the first floor for a retail and medical optometry practice. We will have retail space but are seeking a conditional use permit to have the medical component of our practice on the first floor in order to drive the retail business. Splitting these two entities would not be beneficial for either aspect of the business. The Conditional Use Permit requests under review are: 1. Medical office on the first floor. 2. Parking. The following documentation is submitted in order to obtain permitting for Serendipity Eyecare + Eyewear. Table of Contents: Business Plan Narrative Justification for Medical Space on Lower Level Attachments: Parking Matrix Considerations Offsite Parking Lease - Church List of Property Owners within 200' of site Existing Floor Plan Layout, Condo B - Sheet: A2.01 Proposed Floor Plan Layout - Sheet: EX1 Site Plan Layout and Landscape Plan - Sheet: L1.0 New Parking Layout for STS - Sheet: C3.0 214 Page 2 of 4 Business Plan Narrative: x Serendipity Eyecare + Eyewear (S.E.E.) will be in the business of optometric eye care and optical services. We will be dedicated to the care of our patients with the diagnosis, treatment and management of refractive conditions, ocular health disorders, binocular vision problems, and pediatric care. We will fulfill our patients' needs with comprehensive eye health examinations, glasses, contact lenses, visual rehabilitation, ortho-keratology, LASIK co-management, cataract co-management, sun protection and safety eyewear. x S.E.E. will have retail space designated as the optical and dispensary. This area will contain frames, lenses, contact lenses and contact lens care products. x S.E.E. will be located at 280 W. Kagy, Unit B, South Towne Square in Bozeman, MT among dominant anchors such as Acorn Pediatrics, Gallatin Valley Laundry, Labellum Flower Shop, Moberry, Sola Café, and Seven Sushi. x Bozeman was chosen for start-up of this practice because both doctors have made a commitment to be long term residents of the Bozeman community. x S.E.E. will be formed as an S-Corp owned and operated by Dr. Sarah Hill, O.D., F.A.A.O., F.C.O.V.D. and Dr. Sarah Kirkpatrick, O.D., F.A.A.O. x Dr. Sarah Hill was born and raised in Billings, MT. She received her Bachelor of Science Degree from the University of Montana, located in Missoula, MT and a Doctorate in Optometry at New England College of Optometry located in Boston, MA. Dr. Hill completed her residency in Primary Care and Pediatrics at NOVA Southeastern University in Ft. Lauderdale, FL and received her Fellowship in Primary Care from American Academy of Optometry. Dr. Hill is also a fellow of the College of Optometrist in Vision Development (COVD) and is Board Certified in Vision Development and Vision Therapy. Dr. Hill has been involved with the Optometry industry for six years. Clinical experience includes a three month internship at the VA Bedford Eye Clinic in Bedford, MA, a three month internship at Bascom Palmer Eye Institute in Miami, FL, a three month internship at the Santa Fe Indian Health Services Clinic in Santa Fe, NM, and a 13 month residency in Pediatrics and Primary Care at NOVA Southeastern University in Ft. Lauderdale, FL. Dr. Hill has worked at Heights Eye Care in Billings, MT for the past 5 years and is licensed by the Montana State Board of Optometry and the Florida State Board of Optometry. x Dr. Sarah Kirkpatrick was born and raised in Madison, IN. She received her Bachelor of Science Degree from Indiana University and Doctorate of Optometry at Indiana University School of Optometry located in Bloomington, IN. She completed her residency in Primary Care and Ocular Disease at Bascom Palmer Eye Institute affiliated with Miller School of Medicine/University of Miami in Miami, FL and received her Fellowship in Ocular Disease from the American Academy of Optometry. Dr. Kirkpatrick has been involved with the Optometry industry for 11 years. She was employed as a technician during the summers of 2001 & 2002 by Dr. Robert Kirkpatrick, O.D. at Kirkpatrick Eye Care in Madison, IN. Clinical experience includes a three month internship at Ciba Care Vision Specialists in Des Plaines, IL, a three month internship at Indiana University Health Center in Bloomington, IN, and a six month internship followed by a 12 month residency at Bascom Palmer Eye Institute in Miami, FL. Dr. Kirkpatrick is 215 Page 3 of 4 licensed by Montana, North Carolina, and Florida State Boards of Optometry and has been a practicing Optometrist for over five years. She has practiced in Bozeman, MT for the past three years and currently works for Dr. Jeff Squire at Eyes On Main. x Furthermore, there are very few vision rehabilitation clinics and/or optometrists with pediatric emphasis in Montana and our marketing will include targeting patients and parents of children with learning related vision conditions, strabismus and amblyopia, physical therapists, occupational therapists, pediatricians, naturopathic physicians, and pediatric dental practices. x Mission The mission statement of S.E.E. is to contribute to a lifetime of healthy vision, providing each patient with the highest quality vision care and consequent quality of life. We will seek continuing education to remain at the forefront of our profession and will offer the latest eye care technology, professional services, and products. The visual needs and wellness of each patient will always be our first priority. 216 Page 4 of 4 Justification for Medical Space on Lower Level: Municipal Code Sec. 38.10.010.A.1, lists the intent and purpose as follows: "The intent of the B-1 neighborhood business district is to provide for smaller scale retail and service activities frequently required by neighborhood residents on a day to day basis, as well as residential development as a secondary purpose, while still maintaining compatibility with adjacent residential land uses. Development Scale and pedestrian orientation are important elements of this district." We believe granting this CUP and allowing medical space in the form of optometric eye care and optical services on the ground level does not violate the intent and purpose of B-1 neighborhood business district stated above for the following reasons: 1. As designed, the floor plan established the retail portion of the business in the front. This retail space will be decorated tastefully and will be the only portion of the business visible to pedestrians and passersby. 2. An emphasis of the S.E.E. business plan is children with learning related vision conditions. Being located in district B-1, the parents can patronize the other shops on foot, while their children are being treated at S.E.E. 3. Almost all citizens require optical services, therefore S.E.E., will offer retail and service activities frequently required by neighborhood residents. 4. S.E.E. will also be able to provide comprehensive vision examinations and medical optometry providing full scope family optometric care to the area. A service that does not currently exist in this area of town. 5. The retail and medical portions of the S.E.E. business plan are inextricably tied and placing them on separate building levels would significantly harm the viability of the business. As an analogy, the kitchen in a restaurant is not necessarily a portion of the retail space; however it would not make sense to require that the kitchen be on the 2nd floor while the serving area is on the first floor. The same principle applies to the S.E.E. business. 217 Page 1 of 5 CONDITIONAL USE PERMIT PARKING CONSIDERATION 218 Page 2 of 5 Doctor and Staff Equivalents: Both doctors plan on working 2.5 days per week. This is the full time equivalent of one doctor, 1 FTE. There is will be two full time staff members and one part time vision therapist. The staff full time equivalent will be 2.5 FTE. Retail Space: As shown on sheet EX1, the proposed retail area is: Gross Retail Area = 485 SF 15% Reduction for Walls and Unusable space = 72.8 SF Net Retail Area = 412.2 SF Required Parking Calculation: Table 38.25.040-3 Requirements: 1 FTE Doctor = 4.0 Spaces 2.5 FTE Employees = 2.5 Spaces Retail = 1.0 Space per 300 SF B-1 Reductions: Medical Parking Reduction = 30% Retail Parking Reduction = 40% Medical Parking Demand = 0.7(2.5 + 4) = 4.6 Spaced Retail Parking Demand = 0.6(412.2SF)(1Space/300SF) = 0.8 Spaces Total Parking Demand = 4.6 + 0.8 = 5.4 Spaces Existing and Proposed Parking Available: The matrix below gives the total existing required parking for the three existing and on proposed building at The South Towne Square. The total parking demand is as follows: Total parking Demand = Building 1 + Building 2 + Building 3 + Building 4 + Outdoor Seating = 115.82 Spaces Existing Parking Lot The existing parking on site is = 103 Spaces There is an existing parking lease agreement = 40 Spaces Total existing parking = 143 Spaces Existing Parking Surplus = 146 - 115.82 = 27.18 Spaces South Towne Square plans to redevelop the parking area during the summer of 2013. 219 Page 3 of 5 New Parking Lot The new parking on site is = 141 Spaces New Parking Surplus = 141 - 115.82 = 25.18 Spaces Conditional Use Permit (CUP) Parking Justification: The proposed CUP is for Unit B in Building 2. As the matrix shows below, Unit B in Building 2 has been allotted 3.5 parking spaces. As shown above, the required parking for this CUP is 5.4 spaces. The additional parking required is: Additional Parking Requirement = 5.4 - 3.5 = 1.9 Spaces As shown above, in both the existing and proposed parking conditions for South Towne Square, there is enough surplus parking to allow for 2 additional parking spaces to be allotted to Unit B in Building 2. The proposed new space allotment is: Unit B in Building 2 = 5.5 Spaces Since there is enough surplus parking for both existing and proposed parking areas, approval of this CUP should not be conditioned on the schedule or installation of the new parking development at South Towne Square. 220 Page 4 of 5 Building 1 (Existing) TENANT UNIT AREA USE TYPES REQUIRED SPACES/SQ- FT PER UDO REQUIRED SPACES PERCENT RE- DUCTION FOR B-1 (18.46.040 B 3a) SPACE REQUIRED Sola A 1448 Restaurant 50 29 50 14.5 Antoinette’s B 547 Retail 300 1.8 40 0.72 Lemongrass C 700 Restaurant 50 14 50 7 TOTALS 22.22 Building 2 (Existing) TENANT UNIT AREA USE TYPES REQUIRED SPACES/SQ- FT PER UDO REQUIRED SPACES PERCENT RE- DUCTION FOR B-1 (18.46.040 B 3a) SPACE REQUIRED Gallatin Laundry A 645 Retail 300 2.2 40 1.3 Vacant B 1729 Retail 300 5.8 40 3.5 (proposed 5.5) Labellum C 1157 Retail 300 3.9 40 2.3 Moberry’s D 533 Restaurant 50 10.7 50 5.4 Acorn Pediatrics E-H 5 FTE Docs 8 FTE Other Medical Office 4 spaces per Doctor 1 space per other employee 28 30 19.6 TOTALS 32.1 (proposed 34.1) Building 3 (Existing) TENANT UNIT AREA USE TYPES REQUIRED SPACES/SQ- FT PER UDO REQUIRED SPACES PERCENT RE- DUCTION FOR B-1 (18.46.040 B 3a) SPACE REQUIRED Pilates A 635 Healthy 200 3.2 30 2.2 Food for Thought B 949 Restaurant 50 19 50 9.5 Seven Sushi C&D 700 Restaurant 50 14 50 7 Seybert E 1178 Office 250 4.7 20 3.8 Herzog F 714 Office 250 2.9 20 2.3 Headwater Econ G&H 2007 Office 250 8 20 6.4 TOTALS 31.2 221 Page 5 of 5 Building 4 (Proposed) TENANT UNIT AREA USE TYPES REQUIRED SPACES/SQ- FT PER UDO REQUIRED SPACES PERCENT RE- DUCTION FOR B-1 (18.46.040 B 3a) SPACE REQUIRED To be determined A-D 4250 Retail 300 14.2 40 8.5 To be determined E-H 3400 Office 250 13.6 20 10.9 TOTALS 19.4 Outdoor Seating (Existing) TENANT UNIT AREA USE TYPES REQUIRED SPACES/SQ- FT PER UDO REQUIRED SPACES PERCENT RE- DUCTION FOR B-1 (18.46.040 B 3a) SPACE REQUIRED Area 1/ Sola South A Bldg1 645 Rest 100 6.5 50 3.3 Area 2/ Sola North A Bldg1 176 Rest 100 1.8 50 0.9 Area 3/ Lemongrass C Bldg1 625 Rest 100 6.3 50 3.2 Area 4/ Seven Sushi C&D Bldg3 500 Rest 100 5 50 2.5 TOTALS 9.9 Summary of Required Parking REQUIRED Total Parking Required per UDO for Existing Buildings (1-3) 85.52 Parking Required per UDO for Proposed Buildings (4&5) 38.8 Parking Required for Outdoor Seating 9.9 SUBTOTAL FOR BUILDINGS/OUTDOOR SEATING 134.22 REDUCTIONS Transit Stop Reduction 10% 13.4 Parking Reduction for Landscaping 5.0 TOTAL REDUCTIONS 18.4 TOTAL NET PARKING REQUIRED WITH REDUCTIONS 115.82 TOTAL NET PROPOSED PARKING REQUIRED WITH REDUCTIONS 117.82 222 1 Philip Kedrowski, PE From:sarah hill [sarahh7799@yahoo.com] Sent:Monday, January 07, 2013 11:13 AM To:philipk@redleaf-consulting.com Subject:Fw: Parking allotment for South Towne Square ----- Forwarded Message ----- From: Michael McKenna <mckennamt@gmail.com> To: Sarah Hill <sarahh7799@yahoo.com> Sent: Monday, January 7, 2013 10:02 AM Subject: Re: Parking allotment for South Towne Square I do agree. Good luck. Mike On Jan 7, 2013 9:59 AM, "sarah hill" <sarahh7799@yahoo.com> wrote: Good morning Mike, Currently, our condo space is allotted 3.5 spaces and we need 5.5 spaces to meet the city requirements. As per our conversation this morning regarding the parking spaces, you have agreed that we can have those extra two spaces designated for our office/retail space. Thank you, Sarah Hill 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 CONDITIONAL USE PERMIT ADJOINING PROPERTY OWNERS & ADJOINING NEIGHBORHOODS 241 242 LIST - ADJOINING PROPERTY OWNERS WITHIN 200FT 1. LOCATION: TRACT 1, S. 3RD AVE. MAILING ADDRESS: MUSEUM OF THE ROCKIES, INC. MONTANA STATE UNIVERSITY 600 W. KAGY BLVD BOZEMAN, MT 59717-2730 2. LOCATION: TRACT 2, S. 3RD AVE. MUSEUM OF THE ROCKIES, INC. MONTANA STATE UNIVERSITY 103 CULBERTSON HALL BOZEMAN, MT 59715-5072 3. PROPERTY ADDRESS: 1821 S. WILLSON AVE. BOZEMAN, MT 59715 MAILING ADDRESS: MUSEUM OF THE ROCKIES, INC. MONTANA STATE UNIVERSITY 600 W. KAGY BLVD BOZEMAN, MT 59717-2730 4. PROPERTY ADDRESS: 123 W. KAGY BLVD BOZEMAN, MT 59715 MAILING ADDRESS: KINCAID DENNIS C. & DOROTHY M. 122 BENNET DR. BOZEMAN, MT 59715-8060 5. PROPERTY AND MAILING ADDRESS: JAMES L. BOOTH DDS 121 W. KAGY BLVD BOZEMAN, MT 59715 6. PROPERTY ADDRESS: 121 W. KAGY BLVD BOZEMAN, MT 59715 243 MAILING ADDRESS: KAGY BUILDING, LLC P.O. BOX 206 BOZEMAN, MT 59771-0206 7. MAILING ADDRESS: DAINES CLAIR W, INC. SOUTHWOOD CENTER P.O. BOX 11204 BOZEMAN, MT 59719-1204 8. PROPERTY ADDRESS: 35 W. KAGY BLVD BOZEMAN, MT 59715 MAILING ADDRESS: FELLOWS CRAIG & MARY K 8473 WAGON BOSS RD BOZEMAN, MT 59715-9231 9. PROPERTY AND MAILING ADDRESS: KAGY KORNER STORE, INC. 1809 S. TRACY AVE BOZEMAN, MT 59715-5736 10. PROPERTY AND MAILING ADDRESS: SOLVIE CARL A & ANGIE L 1901 S. TRACY AVE BOZEMAN, MT 59715-6016 11. PROPERTY AND MAILING ADDRESS: SOLVIE CARL A & ANGIE L 1901 S. TRACY AVE BOZEMAN, MT 59715-6016 12. PROPERTY: BARRETT JOHN DAN & MARILYN A 1907 S. TRACY AVE BOZEMAN, MT 59715 MAILING ADDRESS: BARRETT JOHN DAN & MARILYN A 8621 E. KETTLE CIR CENTENIAL, CO 80112-2706 244 13. PROPERTY AND MAILING ADDRESS: RAGENOVICH ALEXANDER O & ELDENE C 1909 S. TRACY AVE BOZEMAN, MT 59715-6016 14. PROPERTY AND MAILING ADDRESS: WILLIAMS JAMES R. 1915 S. TRACY AVE BOZEMAN, MT 59715-6016 15. PROPERTY AND MAILING ADDRESS: HARRIS CHRISTOPHER & JACINTA 2001 S. TRACY AVE BOZEMAN, MT 59715-6018 16. PROPERTY AND MAILING ADDRESS: PILOTTE DONALD A & TERESA G 2007 S. TRACY AVE BOZEMAN, MT 59715-6018 17. PROPERTY AND MAILING ADDRESS: HEALY JAMES M & CARLA ANN 2017 S. TRACY AVE BOZEMAN, MT 59715-6018 18. PROPERTY AND MAILING ADDRESS: ZIMMER RALPH W & GLORIA L 2103 S. TRACY AVE BOZEMAN, MT 59715-6020 19. PROPERTY AND MAILING ADDRESS: BARE MONTE G & KATHI LYTLE 2109 S. TRACY AVE BOZEMAN, MT 59715-6020 20. PROPERTY AND MAILING ADDRESS: STENZEL THOMAS E & DENISE 2117 S. TRACY AVE BOZEMAN, MT 59715-6020 21. PROPERTY AND MAILING ADDRESS: ALLARD JAMES W JR & BUSHING MARY C 2121 S. TRACY AVE BOZEMAN, MT 59715-6020 245 22. PROPERTY AND MAILING ADDRESS: HAYNER KIMERICK F & KATHY 1 HILL ST BOZEMAN, MT 59715-6032 23. PROPERTY AND MAILING ADDRESS: WOLD RANDY T & DIXON BEVERTLY G 2110 S. TRACY AVE BOZEMAN, MT 59715-6021 24. PROPERTY AND MAILING ADDRESS: FAITH L DREDLA TRUST, DREDLA FAITH L & JACK C TRUSTEES 2104 S. TRACY AVE BOZEMAN, MT 59715-6021 25. PROPERTY: GILHOUSEN COMMUNITY PROP TR DTD 3/30/99 GILHOUSEN KLEIN S & KAREN M TRUSTEES 2020 S. TRACY AVE BOZEMAN, MT 59715 MAILING ADDRESS: GILHOUSEN COMMUNITY PROP TR DTD 3/30/99 GILHOUSEN KLEIN S & KAREN M TRUSTEES 599 HIGHTOWER RD BOZEMAN, MT 59718-8163 26. PROPERTY AND MAILING ADDRESS: BURNS ARISON ANTONUCCI & RADNOR 2014 S. TRACY AVE BOZEMAN, MT 59715-6019 27. PROPERTY: GRIFFFEN MICHAEL & GAYLE A 2008 S. TRACY AVE BOZEMAN, MT 59715 MAILING ADDRESS: GRIFFFEN MICHAEL & GAYLE A P.O. BOX 154 BELMONT, CA 94002-0154 28. PROPERTY: COIL MICHAEL C & KRISTIN 2002 S. TRACY AVE BOZEMAN, MT 59715 246 MAILING ADDRESS: COIL MICHAEL C & KRISTIN 3369 SENTINEL DR BOZEMAN, MT 59715-8744 29. PROPERTY: MURRAY GENE R 1916 S. TRACY AVE BOZEMAN, MT 59715 MAILING ADDRESS: MURRAY GENE R 1635 S BLACK AVE BOZEMAN, MT 59715-5701 30. PROPERTY AND MAILING ADDRESS: HEPBURN SUZANNE 1901 S. TRACY AVE BOZEMAN, MT 59715-6028 31. PROPERTY AND MAILING ADDRESS: REGNERUS SHAWN & MEGAN AULT 1908 S. TRACY AVE BOZEMAN, MT 59715-6028 32. PROPERTY AND MAILING ADDRESS: LESTER KJERSTIN R 1904 S. TRACY AVE BOZEMAN, MT 59715-6028 LIST - ADJOINING PROPERTY OWNERS WITHIN SOUTH TOWNE SQUARE 1. MAILING ADDRESS: KAILLO II CORPORATION ATTN: MIKE MCKENNA 3805 VALLEY COMMONS DR. #12 BOZEMAN, MT 59718 2. MAILING ADDRESS: LEVEL INVESTORS ATTN: DAVE SINTON 519 W MENDENHALL BOZEMAN, MT 59715 247 3. MAILING ADDRESS: TIM HERZOG 270 W KAGY BLVD, SUITE F BOZEMAN, MT 59715 4. MAILING ADDRESS: ERIC SEYBERT 270 W KAGY BLVD, SUITE E BOZEMAN, MT 59715 LIST - ADJOINING BOZEMAN NEIGHBORHOODS WITHIN 200' 1. SOUTH EAST NEIGHBORHOOD ASSOCIATION (SENA) ATTN: ALLYSON B. BREKKE NEIGHBORHOOD COORDINATOR - ASSOCIATE PLANNER ABREKKE@BOZEMAN.NET 406.582.2274 248 249 REDLEAF CONSULTING, PLLC Engineering & Drafting Services P.O. BOX 161085, 32 MARKET PLACE, SUITE #4 BIG SKY, MT 59716 PH: 406.995.2996 FAX: 800.521.4840 WWW.REDLEAF-CONSULTING.COM SERENDIPITY EYECARE + EYEWEAR Tenant Improvement Project South Towne Square Building #2, Unit B Bozeman, Montana 59715 Contact: Sarah Hall, O.D., P.C. - (406) 697-4813SHEET NUMBERJOB NUMBER:010413.789START DATE:1/3/2013DRAWN BY:REVIEWED BY:REVISION DATE:P.R.K.‹&RS\ULJKWP.R.K.1/7/2013 - CUP SUBMITTALRDP SEAL:EXPIRES: 6/30/2014FLOOR PLAN AND PROPOSED USE EXHIBIT250 W WWW W W W SSSSSSSSNG NG NG NG NG NG NG NG NG NG NG BT BT BT BT BT BT BT BT BT BT BT BT BP BP BP BP BP BP BP BPBP BP BPBP BPSOUTH TOWNE SQUARE ˆ 2880 Technology Blvd. W. Bozeman, MT 59718 Phone: (406) 587-0721 Fax: (406) 922-6702 SHEET NUMBER PROJECT NUMBER DRAWING NUMBER DRAWN BY: CHK'D. BY: APPR. BY: DATE: Q.A. REVIEW DATE: BY: COPYRIGHT MORRISON-MAIERLE, INC.,2012 VERIFY SCALE! THESE PRINTS MAY BE REDUCED. LINE BELOW MEASURES ONE INCH ON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY! REVISIONS DATEDESCRIPTIONNO.BY N:\5063\002\ACAD\FinalSitePlan\SouthTowneSquare.dwg Plotted by jim ullman on Aug/15/2012 5063.002 1 C0.0 BOZEMAN MONTANA JAU ??? ??? 07/2012 NO SCALE VICINITY MAP LOT 3-A, OF THE AMENDED PLAT OF THE REARRANGEMENT OF THOMPSON'S ADDITION #3 CITY OF BOZEMAN, GALLATIN COUNTY, MONTANA SOUTH TOWNE SQUARE MODIFICATION TO FINAL SITE PLAN COVER SHEET KAGY BLVD.SOUTH 3RD AVENUE251 LEGEND EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING SANITARY SEWER MANHOLE EXISTING STORM DRAIN FACILITIES EXISTING FIBER/TELEPHONE FACILITIES EXISTING ELECTRICAL FACILITIES EXISTING GAS FACILITIES EXISTING TRAFFIC SIGN EXISTING WELL EXISTING CMP CULVERT EXISTING RCP CULVERT ESD EXISTING STORM SEWER MAIN ES EXISTING SAN SEWER MAIN ESS EXISTING SAN SEWER SERVICE F EXISTING FIBER OPTIC EXISTING UNDERGROUND POWEREE EXISTING UNDERGROUND TELEPHONET C C EXISTING UNDERGROUND CABLE G G EXISTING GAS LINE EXISTING OVERHEAD POWER OHT OHT EXISTING OVERHEAD TELEPHONE P P EXISTING PETROLEUM LINE EW EXISTING WATER MAIN EWS EXISTING WATER SERVICE SD SD RD RD PROPOSED STORM DRAIN INLET PROPOSED STORM DRAIN MANHOLE PROPOSED STORM DRAIN PROPOSED ROOF DRAIN PROPOSED SAN SEWER CLEANOUTS WS WS UTIL UTIL PROPOSED GRAVITY SAN SEWER SERVICE PROPOSED DOMESTIC WATER SERVICE PROPOSED UTILITY CONDUIT SS SS EXISTING BUILDING EXISTING BUILDING ROOF EXISTING CONCRETE EXISTING CURB FACE EXISTING CURB FLOWLINE EXISTING TOP BACK OF CURB EXISTING PARKING STRIPE EXISTING ASPHALT////// EXISTING GRAVEL EDGE EXISTING SIDEWALK PROPOSED BUILDING PROPOSED CONCRETE PROPOSED CURB FLOWLINE PROPOSED TOP BACK OF CURB PROPOSED PARKING STRIPE PROPOSED ASPHALT PROPOSED GRAVEL EDGE PROPOSED SIDEWALK GRAPHICAL SIDEWALK JOINT PROPOSED ASPHALT GRADE BREAK EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR 4655 4654 PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR 4655 4654.50PERFPERFPROPOSED PERFORATED DRAIN PIPE IRRIG IRRIG PROPOSED IRRIGATION SLEEVE PROPOSED PRESSURIZED SAN SEWER SERVICESS FM SS FM FIRE FIRE PROPOSED FIRE SERVICE GENERAL NOTES, LEGEND, & ABBREVIATIONS SOUTH TOWNE SQUARE ˆ 2880 Technology Blvd. W. Bozeman, MT 59718 Phone: (406) 587-0721 Fax: (406) 922-6702 SHEET NUMBER PROJECT NUMBER DRAWING NUMBER DRAWN BY: CHK'D. BY: APPR. BY: DATE: Q.A. REVIEW DATE: BY: COPYRIGHT MORRISON-MAIERLE, INC.,2012 VERIFY SCALE! THESE PRINTS MAY BE REDUCED. LINE BELOW MEASURES ONE INCH ON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY! REVISIONS DATEDESCRIPTIONNO.BY N:\5063\002\ACAD\FinalSitePlan\C1-0_General-Notes_Legend+Abbreviations.dwg Plotted by jim ullman on Aug/6/2012 5063.002 2 C1.0 BOZEMAN MONTANA TEE JAU JAU 07/2012 AC ASPHALTIC CONCRETE, ALUMINUM CAP ADA AMERICANS WITH DISABILITIES ACT ADDL ADDITIONAL ADJ ADJACENT, ADJUST AFF ABOVE FINISHED FLOOR ALT ALTERNATE ARCP ARCHED REINFORCED CONCRETE PIPE AVG AVERAGE BC BUILDING CORNER BFF BELOW FINISHED FLOOR BH BOREHOLE BLDG BUILDING BM BENCHMARK BRG BEARING BW BOTTOM OF WALL CHK CHECK CI CAST IRON CIRC CIRCULAR CL CENTERLINE CMP CORRUGATED METAL PIPE CMU CONCRETE MASONRY UNITS CO CLEANOUT COB CITY OF BOZEMAN CONC CONCRETE COORD COORDINATE CP CONTROL POINT CTR CENTER CU CUBIC CU FT, CF CUBIC FEET CULV CULVERT CU YD, CY CUBIC YARD D & L D&L FOUNDRY AND SUPPLY DBL DOUBLE DI DUCTILE IRON, DRAIN INLET ',$‘DIAMETER DIM DIMENSION DIR DIRECTION DTL DETAIL DWG DRAWING E EAST EA EACH, EDGE OF ASPHALT EC EDGE OF CONCRETE EG EDGE OF GRAVEL, EXISTING GROUND EJIW EAST JORDAN IRON WORKS EL, ELEV ELEVATION ELEC ELECTRIC, ELECTRICAL ENGR ENGINEER EP EDGE OF PAVEMENT EX EXISTING EXT EXTERIOR FDN FOUNDATION FETS FLARED END TERMINAL SECTION FF FINISHED FLOOR FG FINISHED GRADE FHYD FIRE HYDRANT FL FLOWLINE FLR FLOOR FT FOOT, FEET FTG FOOTING GA GAGE, GAUGE GAL GALLON GB GRADE BREAK GFA GROSS FLOOR AREA GND GROUND HC HANDICAP HDPE HIGH DENSITY POLYETHYLENE HORIZ HORIZONTAL HP HIGH POINT HT HEIGHT HYD HYDRANT ID INSIDE DIAMETER IE INVERT ELEVATION IN INCH INSUL INSULATE INT INTERIOR INV INVERT LAT LATITUDE LF LINEAR FEET LONG LONGITUDE, LONGITUDINAL LT LEFT MAX MAXIMUM MFD MANUFACTURED MFR MANUFACTURER MH MANHOLE MIN MINIMUM MISC MISCELLANEOUS MPWSS MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS N NORTH NE NORTHEAST NIC NOT IN CONTRACT NOM NOMINAL NTS NOT TO SCALE NW NORTHWEST OC ON CENTER OD OUTSIDE DIAMETER OHP OVERHEAD POWER PC POINT OF CURVE PI POINT OF INTERSECTION PL PROPERTY LINE PRELIM PRELIMINARY PROP PROPERTY PT POINT, POINT OF TANGENCY PVC POLYVINYL CHLORIDE RACET ROAD APPROACH CULVERT END TERMINAL R, RAD RADIUS RCP REINFORCED CONCRETE PIPE RD ROAD, ROOF DRAIN REF REFERENCE RT RIGHT R/W, ROW RIGHT-OF-WAY S SOUTH SAN SANITARY SCH SCHEDULE SD STORM DRAIN SE SOUTHEAST SEC SECTION SPEC SPECIFICATION SQ FT, SF SQUARE FOOT STA STATION SS SANITARY SEWER STD STANDARD SVC SERVICE SW SIDEWALK, SOUTHWEST TB THRUST BLOCK TBC TOP BACK OF CURB TEMP TEMPORARY, TEMPERATURE TOC TOP OF CONCRETE TRANS TRANSITION TW TOP OF WALL TYP TYPICAL UG UNDERGROUND UTIL UTILITY VERT VERTICAL VOL VOLUME W WEST W/WITH W/O WITHOUT WV WATER VALVE XFMR TRANSFORMER NOTE: FOR ABBREVIATIONS NOT LISTED, CONTACT THE ENGINEER. ABBREVIATIONS ADDRESSPURVEYORSECTION PHONE NO. DETAIL AND SECTION DESIGNATION A - X-X SECTION (LETTER) OR DETAIL (NUMERAL) DESIGNATION DRAWING NUMBER (OR SAME DRAWING) ON DRAWING WHERE SECTION OR DETAIL IS TAKEN: DRAWING NUMBER WHERE SHOWN ON DRAWING WHERE SECTION OR DETAIL IS SHOWN: DRAWING NUMBER(S) WHERE TAKEN (406) 582-4631 (406) 585-2354 (406) 522-3958 ANDREA BUFFINGTON TODD JENSEN ENGINEER OF CONTENT (406) 587-0721 CONTACT PERSON JASON WISEMAN JOHN ALSTON PROJECT CONTACT LIST CENTURYLINK NORTHWESTERN ENERGY 20 EAST OLIVE STREET BOZEMAN, MT 59715 BRESNAN COMMUNICATIONS 511 WEST MENDENHALL STREET BOZEMAN, MT 59715 121 EAST GRIFFIN BOZEMAN, MT 59715 2707 WEST MAIN STREET BOZEMAN, MT 59718 JIM ULLMAN 2880 TECHNOLOGY BLVD W BOZEMAN, MT 59718 MORRISON- MAIERLE, INC CITY PLANNING & ZONING BROADBAND CABLE WATER & SANITARY SEWER TELEPHONE ELECTRIC & GAS CITY OF BOZEMAN ADDRESSPURVEYORSECTION PHONE NO. CITY OF BOZEMAN BRIAN KRUEGER 20 EAST OLIVE STREET BOZEMAN, MT 59715 Know what's R GENERAL NOTES: 1.STANDARD SYMBOLS AND LINE TYPES ARE SHOWN IN THE LEGEND. SOME SYMBOLS OR LINE TYPES SHOWN MAY NOT BE SHOWN ON THE PLANS. 2.IN GENERAL, EXISTING STRUCTURES AND FACILITIES ARE NOTED AS "EXISTING" AND ARE SHOWN IN LIGHT LINE WEIGHTS OR AS SCREENED BACKGROUND. NEW STRUCTURES OR FACILITIES ARE SHOWN IN HEAVY LINE WEIGHTS. CONSTRUCTION NOTES: 1.ALL IMPROVEMENTS ON THIS PROJECT SHALL BE COMPLETED IN ACCORDANCE WITH THE MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS, 6TH EDITION DATED APRIL 2010 (MPWSS); THE CITY OF BOZEMAN MODIFICATIONS TO THE MPWSS; THE CITY OF BOZEMAN DESIGN STANDARDS AND SPECIFICATIONS POLICY; AND THE PROJECT SPECIFICATIONS. 2.CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE DIVISION OF INDUSTRIAL REGULATIONS (OSHA) SAFETY STANDARDS. IF REQUESTED BY THE INSPECTOR, THE CONTRACTOR SHALL PROVIDE PROOF OF A PERMIT FROM SAID DIVISION. 3.THE CONTRACTOR'S OPERATIONS SHALL BE CONFINED WITHIN THE PROJECT LIMITS. MATERIALS AND EQUIPMENT SHALL BE STORED ON THE PROJECT SITE WHERE APPROVED BY THE OWNER. IT SHALL BE UNDERSTOOD THAT THE RESPONSIBILITY FOR PROTECTION AND SAFEKEEPING OF EQUIPMENT AND MATERIALS ON OR NEAR THE SITE WILL BE ENTIRELY THAT OF THE CONTRACTOR AND THAT NO CLAIM SHALL BE MADE AGAINST THE OWNER BY REASON OF ANY ACT OF AN EMPLOYEE OR TRESPASSER. 4.CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION. ANY DISCREPANCIES FOUND ARE TO BE BROUGHT TO THE ENGINEER'S ATTENTION PRIOR TO COMMENCEMENT OR CONTINUATION OF CONSTRUCTION ACTIVITIES. 5.REFERENCE ALL SURVEY MONUMENTS, SECTION CORNERS, 1/4 CORNERS, AND PROPERTY CORNERS PRIOR TO BEING DISTURBED BY CONSTRUCTION. ANY MONUMENTS AND CORNERS DISTURBED DURING CONSTRUCTION SHALL BE REPLACED BY A PROFESSIONAL LAND SURVEYOR (PLS) REGISTERED IN THE STATE OF MONTANA. 6.A PRE-CONSTRUCTION MEETING (AS REQUIRED) SHALL BE HELD WITH THE CITY OF BOZEMAN, GENERAL CONTRACTOR, SITE SUBCONTRACTOR, MONTANA DEPARTMENT OF TRANSPORTATION (MDT), AND MORRISON-MAIERLE, INC. PRIOR TO THE START OF CONSTRUCTION. 7.THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND THE CITY, COUNTY, AND/OR STATE INSPECTOR 48 HOURS PRIOR TO COMMENCING CONSTRUCTION AND 24 HOURS IN ADVANCE OF SPECIFIC INSPECTION NEEDS DURING THE COURSE OF THE WORK. ALL WORK SHALL BE PERFORMED DURING NORMAL WORKING HOURS AND SUBJECT TO THE AVAILABILITY OF AN INSPECTOR AND APPROVED BY THE ENGINEER. THE CONTRACTOR WILL BE BILLED FOR SAID INSPECTION SERVICES AS PROVIDED IN THE MOST RECENTLY ADOPTED FEES FOR SUCH SERVICES. 8.THE CONTRACTOR SHALL PERFORM ALL CONSTRUCTION ACTIVITIES IN A MANNER TO MINIMIZE INCONVENIENCE TO THE ADJACENT BUSINESSES AND/OR RESIDENCES. 9.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL PUBLIC AND PRIVATE PROPERTY INSOFAR AS IT MAY BE AFFECTED BY THESE OPERATIONS, ALL COSTS FOR PROTECTING, REMOVING, AND RESTORING EXISTING IMPROVEMENTS SHALL BE BORNE SOLELY BY THE CONTRACTOR. 10.THE CONTRACTOR SHALL AT ALL TIMES TAKE WHATEVER MEASURES ARE NECESSARY TO ASSURE THE PROPER CONTAINMENT AND DISPOSAL OF POLLUTANTS ON THE SITE IN ACCORDANCE WITH ANY AND ALL APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS. 11.THE CONTRACTOR SHALL IMMEDIATELY CLEAN UP ANY CONSTRUCTION MATERIALS INADVERTENTLY DEPOSITED ON EXISTING STREETS, SIDEWALKS, OR OTHER PUBLIC RIGHTS-OF-WAY AND MAKE SURE STREETS AND WALKWAYS ARE CLEANED AT THE END OF EACH WORKING DAY. 12.CONSTRUCTION WORK ZONE TRAFFIC SIGNS SHALL BE FURNISHED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH APPLICABLE REQUIREMENTS OF THE REGULATORY AGENCIES HAVING JURISDICTION. A TRAFFIC CONTROL PLAN, PREPARED BY THE CONTRACTOR, MAY BE REQUIRED BY THE CITY OR STATE. "CONSTRUCTION AHEAD" WARNING SIGNS ARE TO TO BE INSTALLED ALONG ADJACENT ROADS OR DRIVEWAYS. FLASHERS WITH CAUTION TAPE ARE TO BE INSTALLED WHERE ANY CONSTRUCTION ACTIVITY CROSSES A SIDEWALK OR PEDESTRIAN PATH IN ACCORDANCE WITH THE SPECIFICATIONS AND ANY OR ALL LOCAL REGULATIONS. 13.NO STOPPING, PARKING, OR STORING OF CONSTRUCTION MATERIALS IN THE PUBLIC STREETS, FLOOD WAY OR ANY DRIVEWAY IS ALLOWED. 14.THE CONTRACTOR SHALL RESTORE ALL ROADWAY SURFACES TO EQUAL OR BETTER CONDITION THAN EXISTED PRIOR TO EXCAVATION AS DETERMINED BY AGENCY, OWNER, AND/OR ENGINEER. 15.ASPHALT, CONCRETE CURB, AND SIDEWALK SHALL BE SAW CUT OR NEAT CUT AS APPROVED BY THE ENGINEER. 16.THE CONTRACTOR SHALL UTILIZE COMPACTION EQUIPMENT SUITABLE FOR THE SOIL TYPES AND SURFACE MATERIALS ENCOUNTERED ON THE PROJECT. 17.SUBGRADE, SUB-BASE, BASE, AND SURFACE COURSE COMPACTION SHALL CONFORM TO ALL APPLICABLE SPECIFICATIONS NOTED IN THE MPWSS; CITY OF BOZEMAN STANDARD MODIFICATIONS TO THE MPWSS; CITY OF BOZEMAN DESIGN STANDARDS AND SPECIFICATIONS POLICY; AND/OR THE GEOTECHNICAL INVESTIGATION. 18.CONCRETE SHALL BE CLASS M-4000 UNLESS OTHERWISE SPECIFIED. 19.NO CURB AND GUTTER SHALL BE PLACED WITHOUT A FINAL FORM INSPECTION BY THE OWNER OR HIS AUTHORIZED REPRESENTATIVE. 20.CONTRACTION JOINTS SHALL BE CONSTRUCTED BY SAWING OR SCORING. WHEN SCORING, A TOOL SHALL BE USED THAT WILL LEAVE CORNERS ROUNDED AND TO DESTROY AGGREGATE INTERLOCK FOR SPECIFIED MINIMUM DEPTH. 21.GRADE ELEVATIONS INDICATED BY "XX.XX" ON PLANS ARE +4900' TO PROJECT DATUM. 22.SIDE SLOPES FROM DRIVE AND PARKING AREAS SHALL BE 4:1 MAX UNLESS OTHERWISE SPECIFIED. 23.CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT THERE IS A CONSTRUCTION PERMIT APPROVED BY THE MONTANA DEPARTMENT OF ENVIRONMENTAL QUALITY (MDEQ) OR LOCAL GOVERNING AGENCY AS APPROPRIATE FOR THE CONTROL OF STORM WATER RUNOFF. IF THERE IS NOT AN APPROVED PERMIT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING THE NECESSARY APPROVALS FROM MDEQ OR THE LOCAL GOVERNING AGENCY. GENERAL UTILITY NOTES: 1.THE LOCATION, DEPTH, AND SIZE OF EXISTING UTILITIES SHOWN ON THESE PLANS IS APPROXIMATE. THE CONTRACTOR SHALL FIELD VERIFY THE EXISTENCE, LOCATION, DEPTH, SIZE, LINE, AND GRADE OF EXISTING UTILITY CONNECTIONS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY DAMAGE TO THE EXISTING FACILITIES DUE TO FAILURE TO LOCATE OR PROVIDE PROPER PROTECTION WHEN LOCATION IS KNOWN. 2.LOCATION OF SITE UTILITIES SHALL BE VERIFIED BY GENERAL CONTRACTOR AND THE UTILITY COMPANY PROVIDING SERVICE. ANY PROPOSED ADJUSTMENTS TO DRY UTILITY LOCATION SHALL BE COORDINATED WITH UTILITY COMPANIES. 3.PRIOR TO SUBMITTING PIPING DRAWINGS FOR ANY NEW PIPE THAT IS TO CONNECT TO AN EXISTING PIPE OR STRUCTURE, THE CONTRACTOR SHALL EXPOSE THE EXISTING PIPE OR STRUCTURE TO VERIFY ITS EXACT LOCATION, SIZE, MATERIALS, INVERT ELEVATIONS, AND GRADE. 4.THE CONTRACTOR SHALL NOTIFY THE MONTANA ONE CALL CENTER / UDIG @ 811 OR (800) 551-8344 FOR ON-SITE UTILITY LOCATION. ALL EXISTING UTILITIES SHALL BE MARKED BEFORE DIGGING. 5.SITE TO BE ROUGH GRADED PRIOR TO INSTALLATION OF UTILITIES TO ASSURE 6.5 FEET (78 INCHES) OF MINIMUM COVER ON BURIED WATER PIPING OR DEEPER AS SPECIFIED. IF 6.5 FEET OF MINIMUM COVER CANNOT BE OBTAINED, INSULATION OF BURIED WATER PIPING MAY BE REQUIRED. 6.GENERAL CONTRACTOR SHALL HAVE APPROVAL OF ALL GOVERNING AGENCIES HAVING JURISDICTION OVER ANY UTILITY SYSTEM PRIOR TO INSTALLATION. 7.CONTRACTOR TO COORDINATE WITH CITY ENGINEER PRIOR TO CONNECTING TO EXISTING WATERLINES OWNED AND MAINTAINED BY THE CITY OF BOZEMAN. 8.ALL WATER VALVES OWNED AND OPERATED BY THE CITY OF BOZEMAN SHALL BE OPERATED BY CITY OF BOZEMAN WATER DEPARTMENT PERSONNEL ONLY. 9.SEWER AND WATER CONNECTIONS SHALL BE PERFORMED BY A LICENSED PLUMBER. 10.GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR ALL TAP AND TIE IN FEES REQUIRED, AS WELL AS THE COST OF UNDERGROUND SERVICE CONNECTIONS TO THE BUILDING. 11.ALL SANITARY SEWER AND STORM DRAIN PIPING SHALL BE SDR 35 PVC, IN ACCORDANCE WITH ASTM D 3034, UNLESS OTHERWISE NOTED. 12.FIRE SERVICE PIPE MATERIAL SHALL BE CLASS 51 DUCTILE IRON MEETING AWWA C151. DOMESTIC WATER SERVICE PIPE MATERIAL SHALL BE TYPE K ANNEALED COPPER MEETING AWWA STANDARD C800. 13.DIMENSIONS SHOWN ARE TO CENTERLINE OF PIPE OR FITTING. 14.THE PIPE GRADES SHOWN ARE CALCULATED FROM ACTUAL DISTANCES, EDGE OF MANHOLE TO EDGE OF MANHOLE FOR BOTH SANITARY SEWER AND STORM DRAIN AS APPLICABLE. THE DISPLAYED PIPE LINEAL FEET REFLECTS THE DISTANCE FROM CENTER OF MANHOLE TO CENTER OF MANHOLE ON ALL GRAVITY PIPING. 15.LAY PIPE TO UNIFORM GRADE BETWEEN INDICATED ELEVATION POINTS. 16.SIZE OF FITTINGS SHOWN ON DRAWINGS SHALL CORRESPOND TO ADJACENT STRAIGHT RUN OF PIPE, UNLESS OTHERWISE INDICATED. TYPE OF JOINT AND FITTING MATERIAL SHALL BE THE SAME AS SHOWN FOR ADJACENT STRAIGHT RUN OF PIPE. 17.THRUST BLOCKS ARE NOT GENERALLY SHOWN ON THE DRAWINGS. ALL BURIED PIPING SPECIFIED TO BE PRESSURE TESTED, EXCEPT WELDED, GROOVED END, OR SCREWED PIPING, SHALL BE PROVIDED WITH THRUST PROTECTION AT ALL DIRECTION CHANGES, UNLESS OTHERWISE NOTED. 18.ALL VALVES SHALL BE INSTALLED WITH THRUST BLOCKING AND VALVE BOXES IN ACCORDANCE WITH MPWSS AND CITY OF BOZEMAN STANDARDS. 19.VALVE BOXES REQUIRED FOR ALL VALVES IN A BURIED SERVICE. 20.ALL FITTINGS, INCLUDING BENDS EQUAL TO OR GREATER THAN TWENTY-TWO AND ONE-HALF DEGREES ƒ  TEES, AND PLUGS, SHALL BE THRUST BLOCKED IN CONFORMANCE WITH MPWSS OR MUST HAVE MECHANICALLY RESTRAINED JOINTS WHERE INDICATED ON THE PLANS. 21.ALL WATER, STORM DRAIN, AND SANITARY SEWER LEADS TO BUILDING SHALL END 5 FEET OUTSIDE THE BUILDING LIMITS AND SHALL BE PROVIDED WITH A TEMPORARY PLUG AT END. 22.FIRE SERVICE LINE SHALL BE INSTALLED FROM MAIN TO OS&Y VALVE INSIDE BUILDING (REFER TO ARCHITECTURAL PLANS) BY SITE UTILITY CONTRACTOR. 18.REFER TO BUILDING PLAN FOR LOCATION OF SEWER, DOMESTIC, FIRE, ROOF DRAIN (AS APPLICABLE), AND IRRIGATION CONNECTIONS. 19.GENERAL CONTRACTOR TO TRENCH FOR DRY UTILITIES (NATURAL GAS, ELECTRIC, POWER, CABLE, AND CONDUIT). DRY UTILITIES TO BE INSTALLED AS NOTED IN AGREEMENT(S) WITH THE UTILITY COMPANY OR COMPANIES. 20.THE CONTRACTOR SHALL ADJUST ALL NEW AND EXISTING VALVE BOXES, CURB BOXES, AND MANHOLES TO FINAL GRADE UPON COMPLETION OF ALL CONSTRUCTION. ANY BOXES OR MANHOLES DAMAGED OR OTHERWISE DISTURBED BY THE CONTRACTOR OR ANY SUBCONTRACTOR SHALL BE REPAIRED AT THE EXPENSE OF THE CONTRACTOR. THIS WORK SHALL BE INCIDENTAL TO THE PROJECT. SEPARATE PAYMENT WILL NOT BE MADE. (406) 582-3200 (406) 582-2260 252 W WWW W W W W W SSSSSSSSSSNG NG NG NG NG NG NG NG NG NG NG NG NG NG NG ////////////////////////////////////////////////////////////////////////////////////////////////////////////////// /////////////////////////// // ////////////////////////////////////////////////////////////////////////////////// /// ////////////////////////////////////////// ///////////////////////////BT BT BT BT BT BT BT BT BT BT BT BT BT BT BTBT BP BP BP BP BP BP BP BP BP BP BP BP BPBP BP BP BPDEMOLITION PLAN SOUTH TOWNE SQUARE ˆ 2880 Technology Blvd. W. Bozeman, MT 59718 Phone: (406) 587-0721 Fax: (406) 922-6702 SHEET NUMBER PROJECT NUMBER DRAWING NUMBER DRAWN BY: CHK'D. BY: APPR. BY: DATE: Q.A. REVIEW DATE: BY: COPYRIGHT MORRISON-MAIERLE, INC.,2012 VERIFY SCALE! THESE PRINTS MAY BE REDUCED. LINE BELOW MEASURES ONE INCH ON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY! REVISIONS DATEDESCRIPTIONNO.BY N:\5063\002\ACAD\FinalSitePlan\SouthTowneSquare.dwg Plotted by jim ullman on Aug/6/2012 5063.001 3 C2.0 BOZEMAN MONTANA JAU ??? ??? 06/2012 KAGY BLVD.SOUTH 3RD AVENUEDEMOLITION AREA DEMOLITION NOTES: 1.CONTRACTOR IS TO WORK OUT A PHASING PLAN WITH OWNER PRIOR TO STARTING DEMOLITION. 2.CONTRACTOR TO APPLY FOR AND RECEIVE APPROVALS FOR ALL NECESSARY CONSTRUCTION PERMITS REQUIRED FROM MONTANA DEPARTMENT OF ENVIRONMENTAL QUALITY (MDEQ) AND THE CITY OF BOZEMAN. 3.OWNER IS RESPONSIBLE FOR SALVAGING EXISTING LANDSCAPING LOCATED IN THE DEMOLITION AREA PRIOR TO THE START OF DEMOLITION. 4.EXISTING LIGHT POLE LOCATED IN THE DEMOLITION AREA ARE TO BE SALVAGED AND RELOCATED BY THE CONTRACTOR. 5.EXISTING CHURCH FOUNDATION SHALL REMAIN IN PLACE. FINAL FINISH GRADE ELEVATION ALLOWS SAID FOUNDATION TO REMAIN. 6.EXISTING TRASH ENCLOSURES ARE TO BE SALVAGED BY THE OWNER. 7.CONTRACTOR TO USE A METHOD TO NEAT CUT THE SAW CUT LINE. 8.THE CONTRACTOR SHALL COORDINATE WITH THE OWNER FOR A LOCATION TO HAUL AND STORE OVERBURDEN MATERIAL. 253 W WWW W W W W W SSSSSSSSSSNG NG NG NG NG NG NG NG NG NG NG NG NG NG NG BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BTBP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP C C C C C C C C C C C C C CC CCCSITE PLAN SOUTH TOWNE SQUARE ˆ 2880 Technology Blvd. W. Bozeman, MT 59718 Phone: (406) 587-0721 Fax: (406) 922-6702 SHEET NUMBER PROJECT NUMBER DRAWING NUMBER DRAWN BY: CHK'D. BY: APPR. BY: DATE: Q.A. REVIEW DATE: BY: COPYRIGHT MORRISON-MAIERLE, INC.,2012 VERIFY SCALE! THESE PRINTS MAY BE REDUCED. LINE BELOW MEASURES ONE INCH ON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY! REVISIONS DATEDESCRIPTIONNO.BY N:\5063\002\ACAD\FinalSitePlan\SouthTowneSquare.dwg Plotted by jim ullman on Aug/6/2012 5063.001 4 C3.0 BOZEMAN MONTANA JAU ??? ??? 06/2012 KAGY BLVD.SOUTH 3RD AVENUE254 W WWWWW W W W W W W W W SSSSSSSSSSSSSSSSNG NG NG NG NG NG NG NG NG NG NG NG NG NG NG NG NG NG NG NG NG NG NG BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP CURB INLET #1 TBC=07.33 12" IE(SE)=04.30 CURB INLET #2 TBC=05.83 12" IE(NW)=02.78 STORM MH #1 RIM EL=05.92 12"IE(NW)=03.15 12"IE(SE)=02.52 24"IE(SW)=00.60 STORM MH #2 RIM EL=06.00 12"IE(W)=99.75 12"IE(SE)=03.60 STORMTECH INFILTRATION/DETENTION SYSTEM (16 MODULES) INSPECTION PORT IE OUT=03.40 ƒ%(1' SW A L E T O S T R E A M 0 . 6 % M I N . S L O P E 30 LF 12" PERF HDPE @ 0.00% SLOPE (IE=00.01) 26 LF 12" HDPE @ 1.00% SLOPE 26 LF 12" HDPE @ 4.42% SLOPE 6 LF 24" HDPE @ 0.00% SLOPE 26 LF 12" HDPE @ 1.00% SLOPE 20 LF 12" HDPE @ 1.00% SLOPE CURB INLET #3 TBC=06.05 FG=05.60 DRY WELL ISOLATOR ROW SSSSSSSSGRADING PLAN SOUTH TOWNE SQUARE ˆ 2880 Technology Blvd. W. Bozeman, MT 59718 Phone: (406) 587-0721 Fax: (406) 922-6702 SHEET NUMBER PROJECT NUMBER DRAWING NUMBER DRAWN BY: CHK'D. BY: APPR. BY: DATE: Q.A. REVIEW DATE: BY: COPYRIGHT MORRISON-MAIERLE, INC.,2012 VERIFY SCALE! THESE PRINTS MAY BE REDUCED. LINE BELOW MEASURES ONE INCH ON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY! REVISIONS DATEDESCRIPTIONNO.BY N:\5063\002\ACAD\FinalSitePlan\GRADINGPLAN.dwg Plotted by jim ullman on Aug/6/2012 5063.002 5 C4.0 BOZEMAN MT CJF MGH MGH 07/2012 T CATCH CURB SPILL CURB TRANSITION CURB (T) LEGEND NOTES 1.ALL STORM DRAIN MANHOLES SHALL BE 48-INCH DIAMETER, CONSTRUCTED PER CITY OF BOZEMAN STANDARD DETAILS. 0$1+2/(6,1',&$7,1*³5,0 ´6+$//+$9(62/,'&29(567+26(,1',&$7,1*³*5$7( ´6+$//+$9(6/277(' *5$7(' &29(56$1'7+26(,1',&$7,1*³7%& ´6+$//+$9(&85%,1/(77<3(6/277('&29(56 2.ALL STORM DRAIN INLETS SHALL BE 36-INCH DIAMETER, CONSTRUCTED PER CITY OF BOZEMAN STANDARD DETAIL #02720-1. 3.DETENTION POND (UNDERGROUND STORAGE): - BASE ELEV. MODULES = 00.60 (LEVEL) - MAX. SUBGRADE ELEV. = 00.00 - 10-YR WSEL = 03.50 - 10-YR STORAGE VOLUME(MIN) = 979 C.U. FT. SEE SHEET C7.1 FOR UNDERGROUND STORAGE DETAILS 4.SPOT ELEVATIONS ALONG CURB LINES AND SIDEWALK EDGES ARE TOP BACK OF CURB (TBC) AND TOP OF SIDEWALK ELEVATIONS. SUBTRACT 0.50' (SPILL CURB) OR 0.37' (CATCH CURB) TO OBTAIN EDGE OF GUTTER (EG) ELEVATION AT THE ASPHALT/GUTTER LINE. DRY WELL NOTES 1.EXCAVATE A 15' SQUARE BASE AREA CENTERED ON THE DRY WELL. PLACE NON-WOVEN GEOTEXTILE FABRIC IN 7+(%27720$1'6,'(62)7+((;&$9$7,21$1',167$//7+('5<:(//%$&.),//:,7+ô´72´&586+(' :$6+('$1*8/$56721(72´%(/2:),1,6+('*5$'(52&.),//6+$//%()8//<:5$33(',1*(27(;7,/( 21%277206,'(6$1'723:,7+´0,1,08029(5/$3 2.NON-WOVEN GEOTEXTILE FABRIC FOR DRY WELL SHALL BE GEOTEX 601 AS MANUFACTURED BY PROPEX GEOSYNTHETICS AND SUPPLIED BY ROSCOE STEEL, OR ENGINEER-APPROVED EQUAL. 3.'5<:(//6+$//%(´',$0(7(5&21&5(7(:,7+)/$7723$1'6/277('%$55(/6(&7,216$6 MANUFACTURED BY ANDERSON PRECAST & SUPPLY, OR ENGINEER-APPROVED EQUAL. BASE SLAB SHALL HAVE ´72´',$0(7(523(1,1*7+528*+7+(&(17(5727$/+(,*+76+$//%()((70,1,080 4.GRADE TO DRAIN TOWARD DRY WELL INLET IN ALL DIRECTIONS. MAKE SMOOTH GRADE TRANSITIONS, WITH NO ABRUPT GRADE CHANGES. SAW CUT LINE GRADE BREAK 255 SOUTH TOWNE SQUARE ˆ 901 Technology Blvd. Bozeman, MT 59718 Phone: (406) 587-0721 Fax: (406) 587-1176 SHEET NUMBER PROJECT NUMBER DRAWING NUMBER DRAWN BY: CHK'D. BY: APPR. BY: DATE: Q.A. REVIEW DATE: BY: COPYRIGHT MORRISON-MAIERLE, INC.,2012 VERIFY SCALE! THESE PRINTS MAY BE REDUCED. LINE BELOW MEASURES ONE INCH ON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY! REVISIONS DATEDESCRIPTIONNO.BY N:\5063\002\ACAD\FinalSitePlan\C5.0-C5.1_Details.dwg Plotted by jim ullman on Aug/6/2012 5063.002 6 C5.0 BOZEMAN MONTANA JAU 07/2012 SITE DETAILS 256 MIN. 6" ô - 2 INCH CLEAN, CRUSHED, ANGULAR STONE SC-740 END CAP 30" 12" MIN. TYP.51" 6" 96" MAX. 18" MIN. FOR UNPAVED INSTALLATION WHERE RUTTING FROM VEHICLES MAY OCCUR, INCREASE COVER TO 24 INCHES PAVEMENT MIN. WRAP ENTIRE ROCK SECTION IN ADS 601 GEOTEXTILE OR EQUAL CHAMBERS SHALL MEET THE DESIGN REQUIREMENTS AND SAFETY FACTORS SPECIFIED IN SECTION 12.12 OF THE LATEST EDITION OF THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS. LOADS SHALL BE CALCULATED IN ACCORDANCE WITH SECTION 3 (AASHTO) AND SHALL INCLUDE H20 DESIGN TRUCK, IMPACT FACTOR, MULTIPLE PRESENCE FACTOR, AND LANE LOAD. SC-740 CHAMBER 6" 90.7" ACTUAL LENGTH 85.4" INSTALLED NOMINAL CHAMBER SPECIFICATIONS SIZE (W x H x INSTALLED LENGTH) CHAMBER STORAGE MINIMUM INSTALLED STORAGE WEIGHT 30.0" 51.0" x 30.0" x 85.4" 45.9 CUBIC FEET 74.9 CUBIC FEET 75 LBS. 51" ACCEPTS 4" SCH 40 PIPE FOR INSPECTION PORT 8" 2FT MIN. SUMP BED PERIMETER TO OUTLET CONTROL STRUCTURE BB A A PERFORATED UNDERDRAIN PIPE AASHTO M288 CLASS 2 NON-WOVEN GEOTEXTILE [3,3(‘0,1 STONE BEDDING UNDER DRAINAGE PIPE (PER DESIGN) SECTION A_A FOUNDATION STONE BENEATH CHAMBER STORMTECH CHAMBER NUMBER AND SIZE OF UNDERDRAINS PER ENGINEER DESIGN STORMTECH CHAMBER PERFORATED UNDERDRAIN PIPE AASHTO M288 CLASS 2 NON-WOVEN GEOTEXTILE [3,3(‘0,1 STONE BEDDING UNDER DRAINAGE PIPE (PER DESIGN) SECTION B_B FOUNDATION STONE BENEATH CHAMBER STORMTECH LLC ("STORMTECH") REQUIRES INSTALLING CONTRACTORS TO USE AND UNDERSTAND STORMTECH'S LATEST INSTALLATION INSTRUCTIONS PRIOR TO BEGINNING SYSTEM INSTALLATION. OUR TECHNICAL SERVICES DEPARTMENT OFFERS INSTALLATION CONSULTATIONS TO INSTALLING CONTRACTORS. CONTACT OUR TECHNICAL SERVICES REPRESENTATIVE AT LEAST 30 DAYS PRIOR TO SYSTEM INSTALLATION TO ARRANGE A PRE-INSTALLATION CONSULTATION. OUR REPRESENTATIVES CAN THEN ANSWER QUESTIONS OR ADDRESS COMMENTS ON THE STORMTECH CHAMBER SYSTEM AND INFORM THE INSTALLING CONTRACTOR OF THE MINIMUM INSTALLATION REQUIREMENTS BEFORE BEGINNING THE SYSTEM'S CONSTRUCTION. CALL 1-888-892-2694 TO SPEAK TO A TECHNICAL SERVICE REPRESENTATIVE OR VISIT WWW.STORMTECH.COM TO RECEIVE A COPY OF OUR INSTALLATION INSTRUCTIONS. STORMTECH'S REQUIREMENTS FOR SYSTEMS WITH PAVEMENT DESIGN (ASPHALT, CONCRETE PAVERS, ETC.): MINIMUM COVER IS 18 INCHES NOT INCLUDING PAVEMENT; MAXIMUM COVER IS 96 INCHES INCLUDING PAVEMENT. FOR INSTALLATIONS THAT DO NOT INCLUDE PAVEMENT, WHERE RUTTING FROM VEHICLES MAY OCCUR, MINIMUM REQUIRED COVER IS 24 INCHES, MAXIMUM COVER IS 96 INCHES. THE CONTRACTOR MUST REPORT ANY DISCREPANCIES WITH CHAMBER FOUNDATION MATERIALS BEARING CAPACITIES TO THE DESIGN ENGINEER. AASHTO M288 CLASS 2 NON-WOVEN GEOTEXTILE (FILTER FABRIC) MUST BE USED AS INDICATED IN THE PROJECT PLANS. STONE PLACEMENT BETWEEN CHAMBERS ROWS AND AROUND PERIMETER MUST FOLLOW INSTRUCTIONS AS INDICATED IN THE MOST CURRENT VERSION OF STORMTECH'S INSTALLATION INSTRUCTIONS. BACKFILLING OVER THE CHAMBERS MUST FOLLOW REQUIREMENTS AS INDICATED IN THE MOST CURRENT VERSION OF STORMTECH'S INSTALLATION INSTRUCTIONS. THE CONTRACTOR MUST REFER TO STORMTECH'S INSTALLATION INSTRUCTIONS FOR A TABLE OF ACCEPTABLE VEHICLE LOADS AT VARIOUS DEPTHS OF COVER. THIS INFORMATION IS ALSO AVAILABLE AT STORMTECH'S WEBSITE: WWW.STORMTECH.COM. THE CONTRACTOR IS RESPONSIBLE FOR PREVENTING VEHICLES THAT EXCEED STORMTECH'S REQUIREMENTS FROM TRAVELING ACROSS OR PARKING OVER THE STORMWATER SYSTEM. TEMPORARY FENCING, WARNING TAPE AND APPROPRIATELY LOCATED SIGNS ARE COMMONLY USED TO PREVENT UNAUTHORIZED VEHICLES FROM ENTERING SENSITIVE CONSTRUCTION AREAS. THE CONTRACTOR MUST APPLY EROSION AND SEDIMENT CONTROL MEASURES TO PROTECT THE STORMWATER SYSTEM DURING ALL PHASES OF SITE CONSTRUCTION PER LOCAL CODES AND DESIGN ENGINEER'S SPECIFICATIONS. STORMTECH PRODUCT WARRANTY IS LIMITED. SEE CURRENT PRODUCT WARRANTY FOR DETAILS. TO ACQUIRE A COPY CALL STORMTECH AT 1-888-892-2694 OR VISIT WWW.STORMTECH.COM. CHAMBER SYSTEM DESIGN MUST BE IN ACCORDANCE WITH STORMTECH DESIGN MANUAL. 6. 7. 8. 9. 10. STORMTECH GENERAL NOTES 11. 1. 2. 3. 4. 5. SOUTH TOWNE SQUARE ˆ 901 Technology Blvd. Bozeman, MT 59718 Phone: (406) 587-0721 Fax: (406) 587-1176 SHEET NUMBER PROJECT NUMBER DRAWING NUMBER DRAWN BY: CHK'D. BY: APPR. BY: DATE: Q.A. REVIEW DATE: BY: COPYRIGHT MORRISON-MAIERLE, INC.,2012 VERIFY SCALE! THESE PRINTS MAY BE REDUCED. LINE BELOW MEASURES ONE INCH ON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY! REVISIONS DATEDESCRIPTIONNO.BY N:\5063\002\ACAD\FinalSitePlan\C5.0-C5.1_Details.dwg Plotted by jim ullman on Aug/6/2012 5063.002 7 C5.1 BOZEMAN MONTANA JAU 07/2012 STORM TECH DETAILS 257 NEW SITE PLAN PHOTOMETRIC CALCULATIONS SOUTH TOWNE SQUARE FIGURE NUMBER ˆ PROJECT NO.DRAWN BY: CHK'D. BY: APPR. BY: DATE: COPYRIGHT MORRISON-MAIERLE, INC.,2012 2880 Technology Blvd. W. Bozeman MT 59718 Phone: (406) 587-0721 Fax: (406) 922-6702 N:\5063\002\Design Docs\Calcs\Electrical - Lighting\Photometric Calculations-NEW.dwg Plotted by jim ullman on Aug/9/2012 7/10/2012 CDZ CDZ JPT BOZEMAN PH1.0 MONTANA 5063.002 258 259 260 261 262