Loading...
HomeMy WebLinkAboutTab 3 - Pall SoftwarePall Supplied Software Versions Description Version Patches Rockwell Logix 5000 16.81 Rockwell RSLinx 2.54 Rockwell RSNetworx for ControlNet 9.0 Wonderware InTouch 10.1 01 InTouch Driver (DASABCIP)Latest PC Anywhere 12.5 With RSLogix™ 5000 Enterprise Series software, you need only one software package for sequential, process, drive, and motion control programming. This environment is common to the Allen-Bradley® Logix5000 platforms: ControlLogix®, FlexLogix™, CompactLogix™, and SoftLogix5800™, as well as PowerFlex® 700S with DriveLogix™. WHAT'S NEW IN VERSION 15: • support for the S88 phase state model via the PhaseManager™ feature • support for 100 programs and phases per task in ControlLogix and SoftLogix5800 controllers • ability to add 1756 I/O modules during runtime in the local chassis and remotely via ControlNet™ and EtherNet/IP™ • ability to add a new user-defined datatype (UDT) and delete an unreferenced UDT at runtime • more granular security actions for RS Security Server • improved configuration for the PIDE function block • configurable report margins • ability to open a copy of a locked project • filter capability added to tag browser • improved CSV tag import/export includes all attributes • verification of controller serial number on download • enhanced I/O tree view shows chassis and network objects • ability to create a favorites list in the Select Module dialog • ability to enter descriptions in Asian languages RSLogix 5000 Enterprise Series software is available in English, French, German, Italian, Portuguese, and Spanish. Translations include online help, software menus, and dialog boxes. FLEXIBLE, EASY-TO-USE EDITORS One controller project can include multiple routines using these languages: PRODUCT PROFILE 9324 SERIES RSLOGIX 5000 ENTERPRISE SERIES PROGRAMMING SOFTWARE Use this editor: To: relay ladder y develop traditional PLC applications y manage motion and servo control needs y perform messaging and serial communications function block diagram y create flow representations of your application y use specialized process and drive control blocks built in to the environment y develop process and drive control strategies structured text y use a textual-based language for complex mathematical operations y take advantage of the same functions and instructions offered in relay ladder and function block diagram y maintain PLCopen cross-reusability certification sequential function chart y use a highly-visual language to manage program and routine execution y sequence machine states y more easily program machines with repetitive operations The software fully uploads the program logic, including tag names, directly from a controller. This simplifies maintenance because you can always obtain the original source directly from the controller. When you download an application into a controller, the software determines whether the controller firmware is compatible. If not, the software helps you locate the firmware and then updates the controller as part of the download process. You can easily reuse application code across Logix5000 platforms by changing the controller properties of a project. INTUITIVE PROGRAMMING ENVIRONMENT The software displays the IEC 61131-3 compliant, multi-tasking, operating system of a Logix controller as a graphical tree with tasks, programs, and routines. Multiple users can simultaneously monitor and edit the contents of a running Logix5000 controller. Drag-and-drop to move instructions, logic, routines, programs, and tasks, within a single project or between copies of RSLogix 5000 Enterprise Series software, to create project libraries. You can also move program elements between the RSLogix 5 and RSLogix 500 software packages. The software automatically searches for tag descriptions if they are not provided. An alias tag, array tag, or custom data type leverages the descriptions from its base tag or the data type. With custom data types, the software concatenates the tag's root description with the datatype's member description. This creates a very specific description, saves you development time, and improves the resulting documentation. ROBUST, SPECIALIZED INSTRUCTION SET In addition to standard instructions, the software includes: • industry-specific instructions for process, drive, and motion applications. • ASCII instructions to manipulate string data. • message instructions to send and receive data across different devices. • sequential function chart components to structure your application. POWERFUL DATA EDITOR Programs created by the software use IEC 61131-3 compliant, symbolic data addressing. Create a tag by assigning a name and defining the data type. This provides self-documented logic and eliminates the need to memorize the controller’s memory layout. Each tag is stored individually in the controller, so you can create new tags while online with a controller in Run mode. You can create: • tags that are accessible by a single program or accessible by all the programs within the controller. • customized data types by combining multiple data elements into a structure. • arrays of any data type or data structure. RSLinx® software can access the tag list, online in the controller or offline in the software file, and make the tag list available to other software packages. INTEGRATED PROCESS CONTROL y The PhaseManager option embeds an Equipment Phase state model in RSLogix 5000 software that is consistent with ISA-88.01 (S88) equipment and recipe models for batch control and PackML (and Make2Pack) guidelines for machine control applications, encouraging modular code design and code reuse. Firmware functionality enforces the state model. The PhaseManager option also supports premier integration with RSBizWare™ Batch software. y An integrated set of process control instructions is available with function block diagram and structured text languages. Embed structured text in sequential function charts to create simple batch procedures. y The PIDE autotuner simplifies startup by setting gains automatically. y The ActiveX™ and standard RSView™ faceplates streamline development and maintenance by linking control loops to user interface displays. Take advantage of the software to address your batch and continuous process applications. HIGHLY-INTEGRATED MOTION CAPABILITIES The software provides built-in, highly-integrated motion support. A single hardware and software platform meets your combined motion and programmable controller needs. The motion configuration wizard leads you through the parameters of a motion axis. While online, use the built-in marker test, direction test, and auto-tune features to reduce axis setup time. PROTECT YOUR APPLICATION The software comes with a standalone version of the Rockwell Software Security Server for multiple-user, multiple-level password protection for your controller both online and offline. You assign: • full controller access. • read only access. • code read and data read/write access. The software also includes source protection for individual routines. You can restrict individual routines from viewing, editing, printing, and exporting. SUPERIOR DIAGNOSTIC CAPABILITIES The software uses the RSView32 TrendX™ component found in other Rockwell Software products, such as RSView® Enterprise Series software, to provide graphical, real-time data histograms for diagnostic and monitoring functions. Trend as many as eight separate values together. Multiple trends can be active simultaneously. OPEN ACCESS TO PROJECT CONTENTS You can access various portions of your project by: • Windows® Clipboard – cut/copy/paste code and information between RSLogix 5000 Enterprise Series software and other Windows-based tools. • Import/Export Tag Definitions – the Comma Separated Value (CSV) export extracts tags for use by third-party tools such as Microsoft® Excel®. • Full Project Import/Export – this ASCII representation of a controller project provides access to create and manipulate the project using other text editors. • Ladder Diagram Rung Partial Import/Export – this XML-based, ASCII file contains user-selected rungs and their rung comments, tags, and data type definitions. This lets you create external libraries of code that can be imported. RSLOGIX 5000 ENTERPRISE SERIES SOFTWARE REQUIREMENTS Description Value personal computer Pentium®II 450 MHz minimum Pentium III 733 MHz (or better) recommended software requirements Supported operating systems: • Microsoft Windows XP Professional version 2002 (with Service Pack 1 or 2) or XP Home version 2002 • Microsoft Windows 2000 Professional with Service Pack 1, 2, or 3 • Microsoft Windows Server 2003 RAM 128 Mbytes of RAM minimum 256 Mbytes of RAM recommended hard disk space 100 Mbytes of free hard disk space (or more based on application requirements) video requirements 256-color VGA graphics adapter 800 x 600 minimum resolution (True Color 1024 x 768 recommended) Publication 9324-PP001F-EN-P – December 2005 — Supersedes Publication 9324-PP001E-EN-P – September 2005 Copyright ©2005 Rockwell Automation, Inc. All Rights Reserved. Printed in USA. ✶Replace “xx” in the catalog number with the appropriate language designation: EN=English, FR=French, DE=German, IT=Italian, PT=Portuguese, and ES=Spanish. 7 As of RSLogix 5000 programming software version 12. ‡As of RSLogix 5000 programming software version 10.02. §A multiple language editor package is available as 9324-RLDMLPE. It contains the function block, sequential function chart, and structured text editors at a reduced price. ♣To run RSLinx Professional on a PC, the RSLogix 5000 Professional activation key must be installed on the PC's hard drive. RSLinx will start in Lite mode if the RSLogix Professional activation key is installed on a different drive (i.e, floppy drive, or network drive). ➤RSNetWorx for ControlNet is available as 9357-CNETL3. RSNetWorx for DeviceNet is available as 9357-DNETL3. RSNetWorx for EtherNet/IP is available as 9357-ENETL3. They are available together as 9357-ANETL3. a The multiple language editor package (9324-RLDMLPE) is not the same as an upgrade, but it extends the programming languages to match those in a Full package. This package includes two activation keys: one for the Mini Edition (9324-RLD200xxE) and the other for the multiple language editor (9324-RLDMLPE) ™As of RSLogix 5000 programming software version 15 ControlLogix, FlexLogix, CompactLogix, DriveLogix, ProcessLogix, PowerFlex, SoftLogix5800, Allen-Bradley, DriveExecutive, RSBizWare, RSLinx, RSLogix, RSNetWorx, RSView, RSview32, RSView32 TrendX, and Rockwell Software are trademarks of Rockwell Automation. ControlNet is a trademark of ControlNet International, Ltd. DeviceNet is a trademark of the Open DeviceNet Vendor Association. Ethernet and EtherNet/IP are trademarks of Digital Equipment Corporation, Intel, and Xerox Corporation. ActiveX, Excel, Microsoft, Windows, Windows NT, Windows 2000, and Windows XP are registered trademarks of Microsoft in the U.S. and other countries. SELECT THE PROGRAMMING PACKAGE Available Features Logix5000 controllers supported Relay ladder diagram editor§ Function block diagram editor 9324-RLDFBDENE§ Sequential function chart editor 9324-RLDSFCE§ Structured text editor 9324-RLDSTXE§ PhaseManager 9324-RLDPME™ Highly-integrated motion Graphical trending DriveExecutive™ Lite 9303-4DTE01ENE PIDE function block autotune 9323-ATUNEENE RSLogix Architect 9326-LGXARCHENE™ RSLogix Emulate 5000 and RSTestStand Lite 9310-WED200ENE Logix CPU security tool Routine source protection tool Standalone security server explorer RSLinx RSNetWorx for ControlNet RSNetWorx for DeviceNet RSNetWorx for EtherNet/IP➤ FBD ActiveX faceplates Tag data upload/download tool RSLogix 5000 project compare tool Tag custom data monitor tool RSView demo (50 tags/2 hours) Upgrades Service 9324-RLD000xxE✶7 Mini 9324- RLD200xxE✶ Lite 9324- RLD250xxE✶Standard 9324- RLD300xxE✶Standard/NetWorx 9324-RLD300NXxxE✶♣ Full 9324- RLD600xxE✶‡ Professional 9324-RLD700NXxxE✶♣ all7 CompactLogix FlexLogix CompactLogix FlexLogix all all all‡all view only fully supported fully supported fully supported fully supported fully supported fully supported view only upload/download only fully supported upload/download only upload/download only fully supported fully supported view only upload/download only fully supported upload/download only upload/download only fully supported fully supported view only upload/download only fully supported upload/download only upload/download only fully supported fully supported view only available separately available separately available separately available separately included included view only upload/download only upload/download only fully supported fully supported fully supported fully supported fully supported fully supported™fully supported™fully supported fully supported fully supported fully supported available separately available separately available separately included included included included available separately available separately available separately available separately available separately available separately included available separately available separately available separately available separately available separately available separately included available separately na na available separately available separately available separately included included included included included included included included included included included included included included included included included included included included included included Lite included Lite included Lite included Lite included Lite included Lite included Professional included♣ available separately available separately available separately available separately included available separately included included included included included included included included included included included included included included included included included included included included included included included included included included included included included available separately available separately available separately available separately available separately available separately included to Standard: 9324-RLD0U3xxE to Full: 9324-RLD0U6xxE to Professional: 9324-RLD0U7xxE to Standard: 9324-RLD2U3xxE to Professional: 9324-RLD2U7xxE to Full: 9324-RLD25U6xxE to Professional: 9324-RLD25U7xxE to Professional: 9324-RLD3U7xxE to Full: multi-language packa na to Professional: 9324-RLD6U7xxE na RS Linx™is a complete communication server providing plant floor device connectivity for a wide variety of Rockwell Software applications such as RSLogix 5, RSLogix 500, RSLogix 5000, RSView32, and RSSql. In addition, several open interfaces are provided for third-party HMI, data collection and analysis packages or custom client application software. RSLinx is an OPC®- compliant data server supporting the OPC Data Access 2.05 specifications. OPC is the standard for plant floor communications between data servers and client applications. RSLinx provides an OPC custom interface for C/C++ clients and an OPC Automation interface for VB/VBA clients. RSLinx also supports multiple DDE formats (AdvanceDDE, XL_TBL, CF_TXT) for clients such as Microsoft® Excel. RSLinx supports the integration of plant floor devices to supply chain and business decision software applications using products like RSSql. RSLinx can support multiple software applications simultaneously communicating to devices on many different networks. From Anywhere to Anywhere You can virtually communicate from anywhere to anywhere using RSLinx. The product provides a user-friendly graphical interface for navigating through your network hierarchy. This includes routing over the office Ethernet network through a ControlLogix Gateway to get to your control networks and devices on the plant floor. Select a device and right mouse click to access a variety of integrated configuration and monitoring tools such as configuration for the 1756-DHRIO module, Ladder Viewer for PLC-5®, SLC, or MicroLogix®family processors, or a Data Monitor for viewing data out of any ControlLogix, PLC-5, SLC-5, or MicroLogix family controllers. A complete set of communication drivers is provided for your networking needs from older legacy Allen-Bradley networks supported by remote routing through 1785-KA, 1785-KA5, 5130-KA, and 5820-EI to the newer more capable ControlLogix Gateways. Communication hardware such as PCMCIA, serial port, or PC-based network card is supported. The table below lists the supported device/networks: • Ethernet to PLC-5 / SLC-5 / 5820-EI / 1756-ENB • Ethernet/IP CIP Protocol • 1784-KTX(D) / PKTX(D) / PCMK / KT / KT2 to DH+ • 1784-KTX(D) / PKTX(D) / PCMK to DH-485 • 1784-KTCX to ControlNet ™ • 1784-PCC to ControlNet • 1784-PCIC(S) to ControlNet • 1784-PCD / PCIDS to DeviceNet™(Windows NT®) • RS-232 Serial (DF1) to 1770-KF2 / 1785-KE to DH+ • RS-232 Serial (DF1) to 1770-KF3 / 1747-KE / 1747-PIC to DH-485 Technical Data RSLinx • RS-232 Serial (DF1) to PLC-5, SLC-5, MicroLogix, PanelView™ • RS-232 Serial (DF1) to 1770-KFC to ControlNet • RS-232 Serial (DF1) to 1770-KFD to DeviceNet • RS-232 Serial (DF1) to ControlLogix • DF1 Polling Master (RS-232 serial) • DF1 Slave (RS-232 Serial) • SoftLogix 5™Controller • SoftLogix 5800 Controller • Remote Devices via RSLinx Gateway ™ RSWho RSWho is the network browse interface providing a single window to view all configured network drivers. The multi-pane window allows navigation through network hierarchy in the left pane while displaying device icons along with their status in the right pane. A device that appears with a red X through it indicates a communication status error, such as loss of power to a device or disconnected communication cable. Select a device, right-click, and a context-sensitive menu is displayed to perform such actions as Configure New DDE/OPC topic or displaying diagnostic information. This component has been integrated into many of the Rockwell Software products to provide a consistent, easy to use, graphical interface for device selection. Data Table Monitor You can use RSLinx to view data values in a PLC-5, SLC-5, MicroLogix, CompactLogix, FlexLogix or ControlLogix processors. For a PLC-5 / SLC-5 / MicroLogix device, select a data table file to view from a list of available data table files in the controller. For a ControlLogix processor, view tag information in a hierarchical list as the tags are defined in the target device. Multiple data monitor windows can be displayed at the same time providing an effective trouble-shooting tool. Data Monitor functionality is only available with RSLinx Professional and Gateway. 2 Ladder Viewer RSLinx includes an extremely valuable Ladder Viewer for PLC-5, SLC-5, or MicroLogix controller. Based on the RSLogix™ family of programming software, it allows viewing of the ladder code including symbols, address descriptions and rung comments for an effective and complete diagnostic tool when used on your HMI or data collection station on the production floor. To view a ladder program, simply right-click on a processor and select "View Ladder Code" from the context menu. The control program is uploaded from the device and displayed on the screen. If the matching offline program file exists on the PC, then all associated comments and symbols are also displayed. The Ladder Viewer has the capability to select different program files to view. Use this capability in conjunction with the ability to display multiple viewing windows for effective trouble-shooting. Ladder Viewer functionality is only available with RSLinx Professional and Gateway. Remote Gateway Connectivity RSLinx Gateway extends communications throughout the enterprise. RSLinx clients such as RSLogix 5/500/5000 can connect over Ethernet through an RSLinx Gateway and seamlessly go online to a PLC-5, SLC-5, MicroLogix, or ControlLogix processor residing on a control network accessible by the gateway machine. Another key usage of RSLinx Gateway is to optimize communications between multiple OPC clients and plant floor devices. The benefit of using RSLinx Gateway is that overlapping data requests from multiple clients are consolidated into one request to the controller thus reducing the overall network traffic and burden on the target controller. From a cost perspective, you no longer need a copy of RSLinx running on each client machine. Open Interfaces RSLinx provides connectivity for client applications using OPC or DDE. OPC is the preferred interface for data acquisition applications because it is the standard for factory communications. OLE for Process Control (OPC) OPC is based on Microsoft’s OLE technology and is defined and managed by the OPC Foundation, a coalition of industrial/manufacturing companies of which Rockwell Software is a prominent member. The charter of this group is to provide an industry-standard exchange mechanism optimized for performance. RSLinx is an OPC Data Access 2.05 compliant server providing an OPC custom interface for C/C++ client applications and an OPC Automation interface for VB/VBA client applications. The added benefit provided from RSLinx is its ability to provide several DDE formats in addition to OPC and its DDE/OPC diagnostic information. RSLinx also supports multiple DDE formats (AdvanceDDE, XL_Table, CF_Text) for client connectivity. These interfaces are 3 provided mainly for applications developed prior to the incorporation of OPC in RSLinx and are still the primary mechanism for creating DDE Hot Links in Excel. Data Collection Modes In RSLinx, you create a DDE/OPC Topic as a named alias to a targeted device. This alias name is used when requesting data in a client application through the OPC or DDE interfaces. Each topic has parameters to specify poll rate, communication timeout, and the data collection mode (Polled or Unsolicited). In polled mode, RSLinx does all of the work, so it is easy to make changes and control the communications. Polled mode does however, add to the CPU usage on the PC since RSLinx is constantly polling and increases the communication traffic volume compared to unsolicited mode. In Unsolicited mode, data is sent to RSLinx by a message instruction in the processor. RSLinx waits for a packet from the processor instead of polling. The advantage of this mode is that communication traffic is typically reduced due to the controller determining how often to send the data. Unsolicited mode is a good method of transferring large amounts of data that changes infrequently like when a product or batch completes and the record data needs to be transferred to the client. The disadvantage is that unsolicited mode requires ladder programming to gather and send the data. Custom Applications through SDK (Software Development Kit) RSLinx SDK™ is the Software Development Kit used for creating custom applications utilizing the open interfaces built into RSLinx. It contains development files, sample programs, online documentation, and a copy of RSLinx OEM; everything needed to create custom applications to communicate with devices connected to RSLinx. RSLinx provides a migration patch forward for existing INTERCHANGE™ Software applications.In most cases, an INTERCHANGE software application can be ported to RSLinx directly with minimal changes. Operational Tools RSLinx includes a Backup/Restore utility accessible from the Start menu. This tool saves configured drivers, topics, and configuration settings. This allows you to restore your application in case of a hardware failure or even deploy the configuration to another PC. An EDS Hardware Installation tool is provided for registering a new Electronic Data Sheet (EDS). Electronic Data Sheets are used by RSLinx to determine what to display in RSWho and to resolve device properties. An OPC Test Client is included with RSLinx for the purpose of testing OPC communications. This simple tool allows you to test and validate OPC data communications through RSLinx as an HMI or data-based client would interact. Diagnostic Tools RSLinx includes a wealth of diagnostic information to assist you in analyzing your system. Whether it’s troubleshooting a communication problem or analyzing network throughput, RSLinx provides the information you need. Diagnostics fall into three major categories: Networks, Station, and OPC/ DDE. Networks – Diagnostic counters track server information such as messages sent, messages received, messages acknowledged, communication errors, and timeouts. 4 Performance counters give throughput in terms of packets/second. Station – Diagnostic counters indicate information for a selected station such as messages sent and received, message retries, and packet errors. OPC/DDE – Multiple dialogs for DDE clients, OPC Groups, Optimized Packets, and OPC/ DDE server connections display diagnostic information specific to the category. A Communication event log displays information specific to an OPC/DDE transaction. You can configure RSLinx to save communication events automatically at a specified interval thus providing better diagnostic information when trouble- shooting communication problems. Selecting the Right Package RSLinx is available in multiple packages to meet the demand for a variety of cost and functionality requirements. The following table contains specific information on features supported in each package. 5 FEATURES LITE SINGLE NODE OEM SDK PROFESSIONAL GATEWAY Communication Drivers X X X X X X Integrated ControlLogix Gateway Configuration Tool X X X X X X Driver and Station Diagnostics X X X X X X Device Properties X X X X X X Data Monitor XX Ladder Viewer XX DDE Support (CF_Text, XL_Table, AdvanceDDE) X* X X X X Runtime support for local OPC Client Connection X* X X X X Runtime support for custom ‘C’ API application X X X X OPC Automation Interface Documentation, Samples X Remote OPC Client capability X Remote Gateway Client Connection X *Can only communicate with one device. RSLinx Single Node includes the required functionality to supply communications services for all Rockwell Software products. OPC and DDE interfaces are supported, but to only one device. It does not support applications developed for the RSLinx C Application Programming Interface (API) or direct drivers in HMI applications. RSLinx Single Node is used for the following: • Data acquisition using OPC or DDE to only one device. This includes clients such as RSView32, Microsoft Office™, Visual Basic®, and Web pages. • Ladder logic programming using RSLogix products. • Network and device configuration and diagnostics using RSNetWorx • Configuring 1756-ENET, 1756-ENB, 1756-DHRIO, and 1757- SRM modules. • Browsing networks and getting device information such as firmware revision • Supports client applications using OPC (custom or automation) or DDE (AdvanceDDE, XL_TBL, and CF_TXT). RSLinx OEM includes the required functionality to supply communications services for all Rockwell Software products. OPC and DDE clients are supported for any number of devices. It also supports applications developed for the RSLinx C Application Programming Interface (API). RSLinx OEM Versions 2.30 or later support DDE formats XL_TBL and CF_TXT in addition to AdvanceDDE. RSLinx OEM is used for the following: • Data acquisition using OPC or DDE to any number of devices. This includes clients such as RSView32, RSSql, Microsoft Office, Visual Basic, and Web pages. • Ladder logic programming using RSLogix products. • Network and device configuration and diagnostics using RSNetWorx • Configuring 1756-ENET, 1756-ENB, 1756-DHRIO, and 1757- SRM modules. • Browsing networks and getting device information such as firmware revision • Supports client applications using OPC (custom or automation), DDE (AdvanceDDE, XL_TBL, and CF_TXT), or custom applications developed for the RSLinx C API. RSLinx Professional includes the required functionality to supply communications services for all Rockwell Software products. OPC and DDE clients are supported for any number of devices. It also supports applications developed for the RSLinx C Application Programming Interface (API). Additionally, RSLinx Professional contains a data monitor for PLC, SLC, MicroLogix and ControlLogix-based controllers and a ladder logic viewer for PLC and SLC based controllers. RSLinx Professional is great for maintenance and diagnostics. Access your data and ladder logic within RSLinx! RSLinx Professional is used for the following: • Monitoring PLC, SLC, MicroLogix, or ControlLogix data table value directly from RSLinx. • Monitoring ladder logic of PLC, SLC, or MicroLogix family processors directly from RSLinx. • Data acquisition using OPC or DDE to any number of devices. This includes clients such as RSView32, RSSql, Microsoft Office, Visual Basic, and Web pages running on the same PC. • Ladder Logic programming using RSLogix products. • Network and device configuration and diagnostics using RSNetWorx. • Configuring 1756-ENET, 1756-ENB, 1756-DHRIO, and 1757- SRM modules. • Supports client applications using OPC (custom or automation), DDE (AdvanceDDE, XL_TBL, and CF_TXT), or custom applications developed for the RSLinx C API. 6 RSLinx Gateway extends RSLinx-based communications throughout the enterprise by connecting clients over TCP/IP networks. Programming and configuration products such as RSLogix and RSNetWorx use a local RSLinx connection via RSLinx Gateway to communicate to plant floor networks and devices. Remote HMI applications such as RSView32 can use remote OPC to communicate through RSLinx Gateway for data collection. This allows you to have multiple distributed computers performing data collection through an RSLinx Gateway to automatically optimize all OPC communications on the subnets connected to the processors. In addition to the capabilities provided in the RSLinx Professional version, RSLinx Gateway offers remote connectivity to: • Multiple RSView32 clients accessing data through one RSLinx Gateway (remote OPC). • Remote PC running RSLogix connecting to a plant network over a modem for online program changes. • Remote Microsoft Office applications displaying plant floor data such as Excel. • A web page displaying plant floor data when the web server and RSLinx are on separate computers. • Supports client applications using local or remote OPC (custom or automation) • Local DDE (AdvanceDDE, XL_TBL, and CF_TXT), or custom applications developed for the RSLinx C API. RSLinx Software Development Kit (SDK)includes documentation and technical support for developing OPC or C- API clients to RSLinx. OPC clients are developed for data acquisition, while C-API clients are typically used for device configuration. A copy of RSLinx OEM is also supplied with RSLinx SDK. When developing OPC clients to RSLinx, you can use the OPC automation interface for developing a VB/VBA client application or the OPC custom interface for developing a C/C++ client application. RSLinx SDK is used to: • Develop a VB/VBA client using the OPC Automation Interface. With SDK you get documentation on how to use Automation Interface, development support, and samples. • Develop a C/C++ client using the OPC Custom interface. • Develop a client using RSLinx C-API by providing access to libraries and documentation. • Build solutions using RSLinx, which makes it a great resource for OEMs. • Supports direct programming to RSLinx OEM, RSLinx Professional, and RSLinx Gateway. • Supports OPC programming to RSLinx Single Node, RSLinx OEM, RSLinx Professional, and RSLinx Gateway Web Based Answer Station RSLinx Answer Station has been added to the RSLinx "Help" menu. This site is a handy resource to the most up-to-date information about RSLinx products and their use. You can reach this site directly at http://www.software.rockwell.com/assistance/rslinx/. Catalog Numbers RSLinx Lite This item is only available with other appropriate products 9355-WABSNENE RSLinx Single Node 9355-WABOEMENE RSLinx OEM 9355-WABENE RSLinx Professional 9355-WABGWENE RSLinx Gateway 9355-WABCENE RSLinx SDK Updates are also available by calling Technical Services 7 Technical Specifications • Pentium®100 MHz processor (faster processors will improve performance) • 32 MB of RAM minimum (64 MB or more recommended) • 35 MB of available hard disk space (or more based on specific application requirements) • 16-color SVGA display with 800 x 600 or greater resolution • Windows-compatible pointing device RSLinx can be used on any of the following Microsoft operating systems: • Windows XP, Windows 2000 (Workstation, Advanced Server), Windows NT SP3 or later (Workstation or Server), Windows ME, or Windows 98. • RSLinx supports Windows 2000 Terminal Services and Citrix ©2002 Rockwell Software Inc. All rights reserved. Printed in the United States of America. RSLinx, RSLogix, RSLogix 5, RSLogix 500, RSLogix 5000, RSView32, RSSql, AdvanceDDE, RSLinx Gateway, RSWho, RSLinx SDK, INTERCHANGE, RSLinx OEM, RSNetWorx, and the Rockwell Software logo are trademarks of Rockwell Software Inc. PanelView, SoftLogix, ControlLogix, SLC and SLC-5 are trademarks, and PLC, PLC-5, and MicroLogix are registered trademarks of Rockwell Automation. OPC is a registered trademark of the OPC Foundation. Microsoft, Windows, Visual Basic, Windows NT, and Windows 95/98/2000/ME are registered trademarks of the Microsoft Corporation. ControlNet is a trademark of ControlNet International, Ltd., DeviceNet is a trademark of Open DeviceNet Vendors Association, Inc. Pentium is a registered trademark of Intel Corporation. All other trademarks are the property of their respective holders and are hereby acknowledged. Doc ID LINX-TD001C-EN-P Rockwell Software For more information on the latest pricing or a demonstration of any Rockwell Software package, please contact your local Rockwell Automation sales office or Allen-Bradley distributor. For the very latest on Rockwell Software products, visit our website at: www.software.rockwell.com T he NetLinx™Open Network Architecture is the Rockwell Automation strategy of using open networking technology for seamless, top-floor to shop-floor integration. NetLinx is founded upon the use of the producer/consumer model of data exchange, where data is identified rather than attached to explicit source and destination addresses. Based on this identification process, receivers determine whether or not they are to consume and process a particular message. This model provides superior support for seamless data sharing and the most efficient mechanism by which input and output data exchanges can occur. The NetLinx architecture includes the DeviceNet™, ControlNet™, and EtherNet/IP™networks. These three networks speak a common language (Control and Information Protocol - CIP) and share a universal set of communication services that can be seamlessly integrated into an automation system that includes anything from the simplest device to the Internet, helping you to improve flexibility, reduce installation costs, and increase productivity. And since the ControlNet, DeviceNet and EtherNet/IP networks use a common application layer protocol, they also support real-time I/O messaging, configuration and diagnostics over the same network – resulting in faster start- ups and superior diagnostics. RSNetWorx™software configures and manages the communications between those devices on the DeviceNet, ControlNet, or EtherNet/IP networks. A version of RSNetWorx is available for each of these networks, allowing you to take maximum advantage of the synergy between the networks while also leveraging the unique characteristics of each network. Additionally, each RSNetWorx package can be paired with the optional new RSNetWorx MD add-on, providing you with advanced maintenance and diagnostics capabilities. Together, this unified design, configuration, and maintenance strategy allows you to achieve maximum productivity with your network installation and greatly reduce the learning curve associated with deploying and maintaining an automation application. RSNetWorx Common Features RSNetWorx for DeviceNet, ControlNet, and EtherNet/IP provide you with many common features. Using RSNetWorx, you can: • Browse a network automatically and determine what is present on that network via the industry-leading RSLinx communication package (the RSNetWorx installation CD- ROM includes RSLinx). • Use the Electronic Data Sheet (EDS) services provided by the software to configure device parameters and to install support for new devices. The EDS subsystem enables multi-vendor interoperability on each of the networks. • Define the input/output information exchanges that will take place on the network. • Configure peer data exchanges (for example, controller to controller). Technical Data RSNetWorx & RSNetWorx MD for DeviceNet, ControlNet, and EtherNet/IP The new RSNetWorx MD add-on is available for RSNetWorx for DeviceNet, ControlNet, and EtherNet/IP! • Maintain complete control over the mapping of information being exchanged between your controller and devices on the network. The software has “auto-map” capabilities that will automatically perform this mapping for you, or you can manually adjust the mapping. • Define the components of your network (including chassis- based devices) in two different ways: offline and online. In “online” mode, you can either drag and drop devices to the network or let the software determine the actual devices that are present on the network. In “offline” mode, you can drag and drop devices into the network view to specify the devices that will be present on a physical network. When complete, you save this configuration to a file that can subsequently be downloaded to the actual network. • Recover from hardware failures in a straightforward and consistent manner using single commands to upload or download individual devices, or the whole network. • Increase your productivity by viewing error, warning, and informational messages immediately and taking corrective action steps that are available for all messages. • Utilize a common graphical user interface (GUI), including common controls, views, toolbar icons and menu items, increasing your efficiency with each product. • Store an entire configuration in a single file. This provides for easier management of your network configurations. • Produce HTML-formatted reports for scanner, device, and network configuration settings, which can easily be incorporated into your system documentation. • Utilize the RSNetWorx Answer Station (available from the RSNetWorx Help menu), which is a handy resource to the most up-to-date information about RSNetWorx and its uses. You can reach this site directly at http://www.software.rockwell.com/assistance/rsnetworx/. • View a comprehensive product tutorial to help you get the most value from the software as quickly as possible. • Access online versions of related software and hardware manuals directly from RSNetWorx. • Leverage a comprehensive online help system to improve your experience with the software. • Obtain a network-wide health assessment of your network, easily determine the source and severity of diagnosed conditions, and view corrective action information that will lead you through the steps needed to resolve the problem (via the RSNetWorx MD add-on). RSNetWorx MD - You don’t analyze the diagnostic data, MD does! RSNetWorx MD is a Maintenance and Diagnostic subsystem that provides automatic diagnostic analysis and troubleshooting information for the DeviceNet, ControlNet, 2 The EDS Wizard allows you to easily add new EDS files and retrieve updated EDS files from the Web and/or your local computer to support devices on DeviceNet, ControlNet, and EtherNet/IP. Define the devices on your network online or offline using a common graphical user interface. and EtherNet/IP networks. RSNetWorx MD is informed of the available diagnostic data via network and device specific data files, so you don’t configure any device specific diagnostic information within RSNetWorx MD; it is simply installed with RSNetWorx. All diagnostic analysis occurs via any communication path supported by RSLinx (including local connections to the target network as well as any remote routes provided by RSLinx Gateway, Ethernet to ControlLogix Gateway, and Passthrough drivers). And best of all, RSNetWorx MD does not require you to be a network protocol or device expert! As an add-on to the standard RSNetWorx packages, the advanced maintenance and diagnostic features are coupled with the proven configuration management features already provided by RSNetWorx, resulting in the most capable network management software package on the market! The RSNetWorx MD add-on provides many additional features to those already available with RSNetWorx for DeviceNet, ControlNet, and EtherNet/IP. Using RSNetWorx MD, you can: • Query devices on your network automatically for diagnostic attributes, distilling the results of that scan into Normal, Warning, or Error indicators on the RSNetWorx MD user interface. • Troubleshoot faulted diagnostic attributes, providing device diagnostic information as well as corrective action procedures. • View a historical diagnostic log within the Message view in RSNetWorx. When RSNetWorx MD detects diagnostic events, time-stamped notifications are displayed in the Message view. These notifications include the detection of Warning or Error diagnostic conditions, as well as transitions back to the Normal state. • Configure a particular device directly from the Troubleshooter dialog, as well as the classic method of using the main RSNetWorx interface. • Navigate large networks (containing numerous deviceswith complex diagnostics) quickly and easily through diagnostic accelerators to find the next or previous fault. • View connection diagnostic information for the devices on your network (ControlNet and EtherNet/IP only). • View physical media diagnostic information for the devices on your network (ControlNet only). • Increase or decrease the diagnostic timing rate (amount of time between queries of the devices on your network), controlling the network bandwidth consumed by diagnostics. • Launch associated applications (for example, RSLogix 5000, DriveExecutive Lite, Scanlist Configuration Tool, etc.) directly from the Troubleshooter dialog so that you can quickly resolve the specific problem. 3 The most severe diagnostic health indication is bubbled up to the highest level in the tree so you can immediately see if there are any problems on the network. Just a click away from the problem notification is a wealth of information that describes the issue in more detail and defines corrective action steps. RSNetWorx for DeviceNet The DeviceNet network is an open low-level network that provides connections between simple industrial devices (such as sensors and actuators) and higher-level devices (such as PLC controllers and computers). The DeviceNet network uses the proven Control and Information Protocol (CIP) to provide the control, configure, and data collection capabilities for industrial devices. The DeviceNet network is a flexible network that works with devices from multiple vendors. In addition to the common RSNetWorx and RSNetWorx MD capabilities mentioned earlier, with RSNetWorx for DeviceNet you can: • Define configuration settings for devices on the DeviceNet network through a convenient property page interface driven by EDS files for multi-vendor interoperability. • Configure scanners (Rockwell Automation and third party) that use the Allen Bradley DeviceNet libraries. • Control over the mapping of information being exchanged between your controller and devices on the network down to the bit level. • Configure all of the properties of chassis-based devices from a simple property page interface. • Configure the Automatic Device Replacement (ADR) feature that is present within select Rockwell Automation DeviceNet scanners. ADR allows the scanner to automatically restore configuration data to a device, once a failed device has been replaced on the network. • Take advantage of the Producer/Consumer model of information exchange employed by DeviceNet to share inputs between multiple controllers. • Access DeviceNet networks (via RSLinx) that you are directly connected to, or you can route to Ethernet or ControlNet. Additionally, with PLC-5®and SLC controllers you can “pass through” the backplane to the DeviceNet scanner and out onto the DeviceNet network. • Use the Quick Connect feature, which allows a faster connection time between a Quick Connect supported scanner and a Quick Connect supported slave device. For more information, see the ODVA specification. • Use the Faulted Address Recovery (FAR) feature, which allows you to recover any devices that support the faulted node recovery protocol with duplicate node addresses on your DeviceNet network. In addition, you can customize the criteria for detecting faulted devices and “blink” the network LEDs on DeviceNet devices so that they can be easily located on your control system. 4 Scanner configuration is simple using the convenient property page interface. Define and configure chassis-based DeviceNet devices quickly and easily. RSNetWorx for ControlNet The ControlNet network is an open, state-of-the-art control network that meets the demands of real-time, high-throughput applications. The ControlNet network uses the proven Control and Information Protocol (CIP) to combine the functionality of an I/O network with a peer-to-peer network, providing high- speed performance for both functions. A ControlNet network gives you deterministic, repeatable transfers of all mission-critical control data in addition to supporting transfers of non-time-critical data. Program uploads, downloads, and messaging do not interfere with the scheduled delivery of data. In addition to the common RSNetWorx and RSNetWorx MD capabilities mentioned earlier, with RSNetWorx for ControlNet you can: • Configure scanners such as PLC-5C’s and 1747-SCNR’s, as well as third party scanners, that support and implement the ControlNet open specification for scanner configuration. • Configure and manage network-wide parameters that are shared by all devices. • Configure multiple types of connections, including Exclusive Owner, Input Only, Listen Only, and Redundant. • View input and output data (for example, field wiring or voltage settings). • View device and network utilization to maintain device and network efficiency. • View the connections to/from a target device, helping you to solve design time issues by accessing the control information. • Quickly configure and maintain your network by leveraging the Keeper Status and Scanner Signature Status dialogs. • Integrate offline with RSLogix 5000 (version 12 or later) so that ControlNet configurations that include ControlLogix processors can be validated offline. • Support a PLC-5 Hot Backup system, which transfers process control to a secondary system without interrupting the machine and/or process operation (guarding your application against shutdowns caused by a processor failure). • Configure media options (copper, fiber, fiber ring) and media redundancy. • Perform deterministic, repeatable transfers of data to/from digital and analog I/O. • View the results of the network-wide coordinated schedule generated by RSNetWorx to control when information exchanges occur. 5 Configure network-wide parameters, including physical media, which are recognized by all of the ControlNet devices on your network. Insert, modify and delete connections between ControlNet devices. • Create, modify, and delete connection entries in a scanner with a scanlist (for example, a PLC-5C processor, 1747 scanner, or third-party scanner) via the Scanlist Configuration Tool. In addition, you can establish connections among other devices and their respective I/O components (identifying data types, sizes, and timing intervals) and then map that information to the data table. • Establish multicast of inputs, outputs, and peer-to-peer data for improved network efficiency. • Take advantage of the Producer/Consumer model of information exchange to enable shared inputs and redundant owners of outputs. RSNetWorx for Ethernet I/P The EtherNet/IP network is an open industrial networking standard that supports both real-time I/O messaging and message exchange. This network utilizes commercial, off-the- shelf Ethernet hardware (for example, switches and routers) and is fully compatible with the Ethernet TCP/IP protocol suite. This network also uses the proven Control and Information Protocol (CIP) to provide control, configuration, and data collection capability. In addition to the common RSNetWorx and RSNetWorx MD capabilities mentioned earlier, with RSNetWorx for EtherNet/IP you can: • Configure third party scanners that support and implement the EtherNet/IP open specification for scanners. • Configure the devices on your network using host names or IP addresses. • Configure multiple types of connections, including Exclusive Owner, Input Only, Listen Only, and Redundant. • View input and output data (for example, field wiring or voltage settings). • Create, modify, and delete connection entries in a scanner with a scanlist (for example, an EtherNet/IP scanner) via the Scanlist Configuration Tool. • View the connections to/from a target device, helping you to solve design time issues by accessing the control information. • Establish multicast of inputs and peer-to-peer data for improved network efficiency. • Define and configure chassis-based devices quickly and easily with an improved graphical user interface. • Take advantage of the Producer/Consumer model of information exchange to enable shared inputs and redundant owners of outputs. • Establish a network configuration that can be diagnosed using RSNetWorx MD, which provides vital troubleshooting content that you can use to keep your automation system up and running efficiently. 6 Using the Scanlist Configuration Tool, configure and view the status of EtherNet/IP connections. Chassis configuration is painless using the step-by-step interface. Hardware Requirements The following are Hardware Requirements for using RSNetWorx: • Intel®Pentium®microprocessor • CD-ROM drive • 3.5-inch disk drive • 16-color VGA graphics adapter with 640 x 480 or greater resolution (800 x 600 resolution recommended) • Mouse or other Windows ®-compatible pointing device • See the following table for minimum RAM and hard disk space requirements: 7 DeviceNet ControlNet EtherNet/IP Minimum RAM 32 MB of RAM 32 MB of RAM 32 MB of RAM Hard disk space 1, 2 65 MB of available space on the hard drive; 105 MB if you want to install all of the options available; an additional 125 to 460 MB to install the EDS files (depending on the sets of EDS files that you install). 1. As future revisions of RSNetWorx are released, these requirements may change. 2. These sizes are based on a Microsoft FAT file system. A Microsoft NTFS file system will use much less space. 95 MB of available hard disk space; 148 MB if you want to install all of the options available; an additional 20 to 45 MB to install the EDS files (depending on the sets of EDS files that you install). 99 MB of available hard disk space; 105 MB if you want to install all of the options available; an additional 9 to 20 MB to install the EDS files (depending on the sets of EDS files that you install). Software Requirements The following are Software Requirements for using RSNetWorx: • RSNetWorx software can be used with Microsoft Windows 98, Microsoft Windows ME, Microsoft Windows NT 4.0 (Service Pack 6 or later), Microsoft Windows 2000, Windows 2000 Terminal Server, Microsoft Windows XP, and Citrix operating systems. Contact Rockwell Automation Technical Support if you require support for the Microsoft Windows 95 operating system. • RSLinx version 2.40 (or later). • RSLogix 5 version 4.0 (or later); version 5.50 (or later) recommended. • RSLogix 5000 version (any version) for online integration; version 12 (or later) for offline integration on ControlNet. • Abobe™Acrobat™Reader installed to use the product manuals feature. You can install the reader from the RSNetWorx CD. • Microsoft Internet Explorer 4.0 (or later) to use the online help. ©2002 Rockwell Software Inc. All rights reserved. Printed in the United States of America. RSNetWorx , RSLinx, and the Rockwell Software logo are trademarks of Rockwell Software Inc. Microsoft, Windows, Windows NT, and Windows 95/98/2000/ME are registered trademarks of the Microsoft Corporation. DeviceNet is a trademark of Open DeviceNet Vendors Association, Inc. Pentium is a registered trademark of Intel Corporation. All other trademarks are the property of their respective holders and are hereby acknowledged. Doc ID NETWRX-TD001A-EN-P Rockwell Software For more information on the latest pricing or a demonstration of any Rockwell Software package, please contact your local Rockwell Automation sales office or Allen-Bradley distributor. For the very latest on Rockwell Software products, visit our website at: www.software.rockwell.com Cabling and Installation Options When installing and commissioning your DeviceNet, ControlNet, or EtherNet/IP networks, please consult the following manuals or more information: •DeviceNet - DeviceNet Cable System Planning and Installation Manual (DN-6.7.2) •ControlNet - ControlNet Coax Cable System Planning and Installation Manual (1786-6.2.1) •EtherNet/IP - EtherNet/IP Media Planning and Installation Manual (ENET-IN001A-EN-P) Catalog Numbers Configuration only RSNetWorx for DeviceNet 9357-DNETL3 RSNetWorx for ControlNet 9357-CNETL3 RSNetWorx for EtherNet/IP 9357-ENETL3 RSNetWorx products are also available in various bundled offerings. These bundles include all RSNetWorx Configuration only products and all RSNetWorx Configuration plus Maintenance and Diagnostics products. In addition, you can also purchase RSNetWorx bundled with your favorite RSLogix editor (5, 500, or 5000). Add-ons are also available to update your existing RSNetWorx Configuration only product to include the Maintenance and Diagnostics functionality. Please contact your Rockwell Automation distributor to select the product offering that is right for you. Configuration plus Maintenance and Diagnostics RSNetWorx MD for DeviceNet 9357-DNETMD3E RSNetWorx MD for ControlNet 9357-CNETMD3E RSNetWorx MD for EtherNet/IP 9357-ENETMD3E 26561 Rancho Parkway South Lake Forest, CA 92630 U.S.A. Tel 949-727-3200 Fax 949-727-3270 www.wonderware.com © 2008 Invensys Systems, Inc. All rights reserved. No part of the material protected by this copyright may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, broadcasting, or by any information storage and retrieval system, without permission in writing from Invensys Systems, Inc. Invensys, Wonderware, ArchestrA, Factelligence, IntelaTrac, InBatch, InControl, IndustrialSQL Server, InSQL, InTouch, InTrack, QI Analyst, SCADAlarm SuiteLink, SuiteVoyager, WindowMaker, WindowViewer are trademarks and registered trademarks of Invensys plc, its subsidiaries and affiliated companies. All other brands and product names may be the trademarks or service marks of their respective owners. PN 15-0196 Rel. 11/08 © 2008 Invensys Systems, Inc. All rights reserved. No part of the material protected by this copyright may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, broadcasting, or by any information storage and retrieval system, without permission in writing from Invensys Systems, Inc. Invensys, Wonderware, ArchestrA, Factelligence, IntelaTrac, InBatch, InControl, IndustrialSQL Server, InSQL, InTouch, InTrack, QI Analyst, SCADAlarm SuiteLink, SuiteVoyager, WindowMaker, WindowViewer are trademarks and registered trademarks of Invensys plc, its subsidiaries and affiliated companies. All other brands and product names may be the trademarks or service marks of their respective owners. InTouch Brochure.qxd:InTouch Brochure 12/1/08 3:20 PM Page 16 InTouch Brochure.qxd:InTouch Brochure 12/1/08 3:18 PM Page 1 InTouch Brochure.qxd:InTouch Brochure 12/1/08 3:18 PM Page 2 Powerful and Sophisticated, Easy to Use Already established as the world’s favorite HMI and used in over one-third of the world’s plants, in virtually every country and industry, Wonderware InTouch software raises the bar for excellence with a host of features and capabilities, including: InTouch software enables engineers to become more productive and creative, in building compelling, intuitive, secure, reliable and maintainable HMI, SCADA and MES applications while reducing application development costs. Wonderware InTouch software leaps onto your screen with breakthrough technology, amazing graphic capabilities and comprehensive functionality delivered with Wonderware’s legendary ease of use. The award winning Wonderware InTouch Human Machine Interface (HMI) continues to outshine the competition with intuitive user interaction, robust runtime functionality, seamless integration with the Wonderware System Platform and unparalleled investment protection. InTouch software is an open and extensible HMI with cutting-edge graphical capabilities providing incredible power and flexibility for application design with connectivity to the broadest range of systems and devices in the industry. Whether you’re an engineer or an operator, an end-user or a system integrator, an OEM or a VAR, Wonderware InTouch HMI gives you the breakthrough capabilities you need, to realize your own breakthrough improvements in operational and engineering productivity. Your Breakthrough Solution for Enterprise-wide Visualization and HMI Vibrant, resolution-independent ArchestrA graphic capabilities, for realism, clarity and attention Versatile, user-friendly, multi-user development and editing environment for collaborative engineering productivity Powerful self–contained ArchestrA graphical symbols with integrated scripting and connectivity to preserve engineering effort through re-use and standardization Unprecedented power and flexibility with comprehensive scripting and graphical animation capabilities enables software engineers as well as non-programmers and novices to quickly customize application functions Complete control with the Wonderware Development Studio, providing a single consistent environment for centralized management and remote deployment of HMI applications everywhere, including the new Wonderware Compact Panels. Incredible scalability from simple single-node HMI to enterprise-wide supervisory solutions using the Wonderware System Platform Comprehensive library of pre-built, eye- popping graphical symbols and faceplates Built-in features for consistent handling and visualization of data quality Complete backwards compatibility with existing InTouch software applications Operational features that provide clear, clutter free, accurate and compelling visualization, while greatly expanding the amount of information available InTouch Brochure.qxd:InTouch Brochure 12/1/08 3:18 PM Page 3 Breakthrough Visualization Capabilities InTouch software empowers you to quickly and easily develop custom graphical views of your real-time industrial processes. InTouch software provides a comprehensive range of graphics primitives from which graphical symbols may be created, including arcs, chords, pies, curves and Microsoft Windows®common controls, as well as the ability to create complex shapes by combining simpler shapes together. Advanced graphic attribute manipulation enables extremely powerful and precise control, via built-in animation or scripting of an incredible range of graphic attributes including transparency, smooth shading, fill style, line style, orientation, size, position and visibility enabling engineers to exercise their imagination and creativity to represent automation environments with style, utility and efficiency. InTouch software comes equipped with an extensible ArchestrA symbol library containing over 500 professionally designed ArchestrA graphic symbols, most with customizable ‘intelligence’ already incorporated, giving you drag-and-drop access to pre-built engineering components. Library symbols may be used out-of- the-box or customized as needed. You may add your own new or modified symbols, or you may create your own special libraries of symbols to suit your engineering and development requirements. Ready-to-use Symbol Library InTouch Brochure.qxd:InTouch Brochure 12/1/08 3:19 PM Page 4 Consistent built-in primitives for quality provide quality information for acquired data in a consistent form making it extremely easy to view and act upon changes in data quality. The InTouch graphics environment offers incredible power and choice to use or mix together vector graphics, bitmap graphics, library symbols, .NET controls and legacy ActiveX controls. ArchestrA symbols directly support embedded .NET controls, giving you the freedom for unrestricted application extensibility without programming. They also offer access to standard controls such as Web browsers, desktop applications, mapping tools, ERP components and any other application which provides .NET compliant controls. Versatility and Extensibility ArchestrA symbols directly support embedded .NET controls, giving you the freedom for unrestricted application extensibility without programming. InTouch Brochure.qxd:InTouch Brochure 12/1/08 3:19 PM Page 5 Conveyor Specialist Tank Specialist Machine Specialist Concurrent Development The Wonderware Development Studio preserves and expands the legendary ease of use and now includes a common Integrated Development Environment (IDE) for both the Wonderware System Platform and InTouch HMI. This enables engineers and developers to create applications of unprecedented power, flexibility and scalability, from the smallest HMI application to the largest enterprise automation network-all within a single consistent toolset. The feature-rich ArchestrA IDE found in both InTouch HMI and System Platform provides powerful multi-user features, check- out and check-in of objects and symbols under development, and graphical feedback to developers of significant changes. The ArchestrA IDE provides access to rapid propagation of changes throughout an application and even across multiple networked PC nodes. One Powerfully Simple Development Environment The ArchestrA IDE provides powerful multi-user features, check-out and check-in of objects and symbols under development, and graphical feedback to developers of significant changes by team members. InTouch Brochure.qxd:InTouch Brochure 12/1/08 3:19 PM Page 6 Standardize, Organize, Customize InTouch HMI enables you to quickly create applications that adhere to company standards yet are versatile enough to be deployed strategically throughout an organization using the best-suited devices. InTouch software provides a powerful hierarchical project viewer allowing the InTouch HMI tag database to be logically managed in organized groups to simplify the creation and maintenance of InTouch HMI applications. Dynamic resolution conversion provides real- time scaling between screen resolutions, so you can view and develop InTouch applications on a variety of screen resolutions without having to convert the application. The powerful QuickScript Editor enables you to extend and customize applications to address specific system requirements whether you are an expert software engineer or a non-programmer. Scripts can be configured to execute based on numerous parameters, such as specific process conditions, data changes, application and windows events, keyboard strokes and ActiveX or .NET control events. Users also can develop a library of scripts that can be re-used to simplify the application resulting in decreased initial engineering and application maintenance time, as well as deployment. With features like InTouch Fast Switch from development mode to runtime mode, and instant previews in the ArchestrA symbol editor, developers can quickly determine how their applications will look and behave before deploying them into a production environment. Organize and view plant functionality and operations. The InTouch HMI tag database is logically managed in organized groups to simplify the creation and maintenance of InTouch applications. InTouch Brochure.qxd:InTouch Brochure 12/1/08 3:19 PM Page 7 Comprehensive graphic toolbox unleashes your creativity. Every graphic element and sub-group is individually editable providing tremendous control of your graphics with absolute ease. InTouch Brochure.qxd:InTouch Brochure 12/1/08 3:19 PM Page 8 Every attribute of your graphic can be individually animated. InTouch Brochure.qxd:InTouch Brochure 12/1/08 3:19 PM Page 9 Actionable Intelligence Knowledge is power; and sophisticated, intelligent and interactive graphics that accurately communicate the right information are the key to this knowledge. Powerful, intelligent graphics capabilities provide context to data, enable faster analysis, and facilitate better and more rapid understanding of displayed information. Operators are presented the right information, at the right time, and in the right format.This empowers you to make timely, informed decisions, take corrective actions to reduce costs and operational incidents, and improve productivity across the entire operation. You will be able to take advantage of robust, reliable, consistent HMI solutions with clutter-free screens and intelligent size- scalable faceplates. InTouch data aware controls, intelligent graphical objects and built-in provision of quality information, plus robust .NET controls give you intuitive, accurate and consistent visualization of operational processes making you more productive, efficient and effective. Dynamic symbol scaling, “Tooltips” and “mouse-over” capabilities enable you to obtain more information, more quickly about operational conditions in streamlined, uncluttered screens that provide focus to the task at hand. Great multi-monitor support enables you to construct comprehensive multi-screen HMI applications with precise control of visualization and interaction Great multi-monitor support enables you to construct comprehensive multi- screen HMI applications with precise control of visualization and interaction. InTouch Brochure.qxd:InTouch Brochure 12/1/08 3:19 PM Page 10 React and Respond in Real-Time Timely visibility to system alarms and the ability to acknowledge them promptly can significantly reduce costly downtime, enable faster responses in critical situations, and provide opportunities for preemptive resolution of potentially critical situations. Powerful InTouch Software troubleshooting tools include: InTouch software also provides runtime configurable tools to enable users to quickly determine the nature and location of an alarm, with options for supporting fast analysis and response to alarm conditions. Distributed Alarm Display – provides comprehensive summary information of current alarms Database View Control – displays a historical view of alarms for analysis and incident review Alarm Viewer Control – an ActiveX control that provides both current summary and historical session alarm information InTouch provides quick, accurate visibility to system alarms and significantly enables faster responses in critical situations. InTouch Brochure.qxd:InTouch Brochure 12/1/08 3:19 PM Page 11 Connect and Collect InTouch software can connect to virtually any industrial automation and information system and devices using hundreds of available I/O and OPC servers that are designed to work with Wonderware products. The InTouch HMI is capable of serving as an OPC client or an OPC server, and Wonderware servers provide access to InTouch application data through: OPC technology Wonderware SuiteLink protocol Microsoft DDE communications Third-party developers also can use the ArchestrA DA Server toolkit to create additional servers that incorporate one or all of the communication methods listed above. IT Friendly, Manageable, Secure, Extensible, Industry Standard InTouch software makes it easier, more time efficient and less costly for you to manage HMI applications in larger deployments. InTouch software is IT-friendly with a centralized application management environment, a robust centralized security model, extensibility capabilities and built-in diagnostics. InTouch software is easy to manage, secure and support with its data aware controls featuring built in primitives for data security, quality, and status as well as support for .NET controls, support for Terminal Services, Office 2007 and Microsoft Vista. InTouch HMI gives you flexibility with support for existing InTouch HMI applications alongside new graphics so you can upgrade one node at a time at your own pace. InTouch software enables you to utilize industry-leading standards, as well as adopt your own internal standards, which can be used throughout your operation, ensuring consistency, minimizing customizations and reducing the risk of unplanned incidents. Create International Applications for Global Use InTouch software is fully supported in English, German, French, Japanese and Simplified Chinese, with additional languages available and supported around the world by local distributors. Support for UTC time, local time, time offsets, and daylight savings time greatly simplify the task of creating global applications. InTouch software leverages Microsoft Tablet PC features such as inking and annotation enabling you to write values and notes in your own handwriting. InTouch Brochure.qxd:InTouch Brochure 12/1/08 3:19 PM Page 12 Architectural Flexibility and Complete Scalability InTouch software can be used as self-contained, standalone visualization stations or as an integrated part of the Wonderware System Platform distributed architecture. A Terminal Services edition of InTouch software is available which can support multiple Terminal Services sessions from a single server on appropriately configured hardware. As the easiest to learn HMI in the industry, you can always start small and very quickly create a running application in production. When you are ready to expand, leverage the flexible and scalable ArchestrA software architecture to increase system size and complexity at your discretion to meet future requirements. Scalability from a single low end /low price node to over 400 networked PCs. Start with one node and be prepared to expand to 1 million I/O. Unequaled Investment Protection Wonderware’s continuing uncompromising and unequaled history of continuous support of our customers existing investments, InTouch applications created with the very first HMI version can be upgraded and used with the very latest InTouch software with ease. All of the features of InTouch ArchestrA graphics work in concert with the full range of capabilities available with earlier versions of InTouch software. Existing InTouch HMI applications can be upgraded to InTouch HMI and work with no modifications whatsoever! InTouch HMI provides the capabilities to modify and extend these applications with all of the new features whenever you want or need to do so. Security Where, When and How You Need It InTouch software provides a selection of integrated security models and options to match your requirements, including: Access-Level Password Security – limits user capabilities in the InTouch HMI application based on areas of responsibility and authority Microsoft Windows Authentication – grants permissions to InTouch HMI users authenticated on a domain controller or local computer, based on user identity and group affiliations Data Level Security – customers who have adopted the Wonderware System Platform also enjoy secure integration from InTouch software all the way down to the level of each data element or attribute. FDA 21 CFR Part 11 Functionality – built-in authentication fields, security script functions and variables make it easier for users to comply with government regulations InTouch Read Only Software – a view-only runtime version of the InTouch application which prevents changing data or execution of controlsInTouch software makes it easier, more time efficient and less costly for you to manage HMI applications in larger deployments. InTouch Brochure.qxd:InTouch Brochure 12/1/08 3:19 PM Page 13 Breakthrough Architecture—No Limits Used together, the InTouch HMI and Wonderware System Platform provide an information and automation application environment of unprecedented power, scalability and ease of use; significantly greater than the sum of the parts. The integration of the ArchestrA IDE and the new graphics capabilities of InTouch HMI provide a smooth upgrade path for InTouch software users into the world of ArchestrA applications and the Wonderware System Platform. The upgrade path offers users the benefits of scalability and increased functionality without sacrificing prior investments in InTouch HMI application development. While the Wonderware System Platform is not required to run InTouch software, it’s the ultimate add-on for InTouch software that will redefine your expectations for a supervisory system: ArchestrA Graphics and Application Objects – the powerful component objects within the System Platform encapsulate InTouch ArchestrA graphics along with application logic, I/O, history and data storage, enabling drag-and-drop solution engineering. This is an incredible time saver, which also improves the consistency and maintainability of applications. Common Plant Model – moves beyond the simple tag databases of traditional HMIs. As a logical representation of physical equipment and processes, the common plant model of the Wonderware System Platform abstracts equipment and systems into a more powerful and productive application development environment with extensive benefits for engineering reusability and reduced lifecycle cost. Managed Applications – enable easy and robust remote application deployment and management from a centralized environment, with change propagation across your entire network. Extensible Universal Application Platform – builds on the rich graphic capabilities of InTouch HMI to extend into all types of plant and industrial applications. Automatic Configuration of System-Wide Functions – so that information is configured once centrally, and can be re-used for any application that needs it, including graphics, history, alarm and event functions, security, logic, scripting, inputs and outputs. Common Namespace – across a Wonderware System Platform separates application code from device communications so both can be easily managed and updated, allowing re-use on any machine or application. Extended Data Security and Status Indication – builds on the capabilities inherent in InTouch software. The Wonderware System Platform extends the level of granularity in the definition and response for data security and status indication in a system. Wonderware Production & Performance Management Modules – provide a comprehensive set of functional modules that can extend the Wonderware System Platform to fit any production or performance management need. These modules help customers optimize equipment operations and performance, improve manufacturing quality, enforce manufacturing and batch execution as well as integrate plant application to enterprise systems. World-class Customer Support & Services The Wonderware Customer Support Services Program makes it easy to learn, stay current, gain access to best practices and get assistance from the leading support team in the industry. This program includes access to our extensive online knowledge base center, security center, and web based training. To learn more about this valuable program contact your local sales representative. InTouch Brochure.qxd:InTouch Brochure 12/1/08 3:19 PM Page 14 InTouch Brochure.qxd:InTouch Brochure 12/1/08 3:19 PM Page 15 Symantec pcAnywhere™ 12.5 Industry-leading remote control solution for faster help desk support and issue resolution Data Sheet: Client and Systems Management Confidence in a connected world.Page 1 of 3 Overview As remote offices and telecommuting become more prevalent, the ability to manage devices from virtually any location is quickly changing from a luxury to a necessity. Symantec pcAnywhere™, a leading remote control solution, helps organizations access and securely manage remote computers to resolve issues quickly. pcAnywhere supports multiple platforms for both host and remote systems, including Windows® (including Vista® and Windows Server® 2008), Linux®, and Mac®. Systems can also be securely accessed from Windows Mobile®/Pocket PC devices and Web browsers. pcAnywhere 12.5 allows you to easily connect to mission-critical servers and endpoint devices, ensuring complete control—even if your building becomes inaccessible. Features and benefits •Provides a feature-rich, secure, reliable remote control solution to accelerate resolution of help desk calls. •Offers heterogeneous host and remote platform support across Windows, Linux, and Mac OS X. All hosts can also be accessed from Microsoft® Pocket PC devices or Web browsers. •Supports 64-bit environments. •Gateway option enables real-time discovery of and connection to multiple devices behind firewalls and NAT devices, which mitigates private and dynamic IP challenges, and minimizes port opening and forwarding. •Host invitation feature simplifies the process of hosts establishing a reverse connection from behind firewalls and NAT devices. •User interface provides simple, graphical, task-based options. You can also combine the pcAnywhere Manager with all active sessions into a single window. •Mobile remote management tools reduce the steps, bandwidth, and time required for remote troubleshooting and issue resolution from Pocket PC and Pocket PC Phone devices. •The Symantec pcAnywhere Access Server option facilitates the discovery of and connection to multiple pcAnywhere hosts from anywhere—regardless of location or network configuration. (Sold separately; works in conjunction with pcAnywhere 12.x.) •AES encryption algorithm provides users with a choice of all available cipher strengths (128-bit, 192-bit, and 256-bit) in addition to the currently offered RC4 symmetric algorithm and other options (pcAnywhere encoding, public key, or none). pcAnywhere encryption is FIPS 140-2 validated. •Supports multiple authentication methods so you can use existing network authentication user names and passwords. •Windows PE support allows you to use a pcAnywhere Thin Host within Windows PE operating system. Data Sheet: Client and Systems Management Symantec pcAnywhere™ 12.5 Confidence in a connected world.Page 2 of 3 •Symantec pcAnywhere Mobile™ permits a connection to and remote control of a standard pcAnywhere host from a current market-standard Pocket PC device over any TCP/IP connection, including wireless (cellular, Bluetooth®, and WiFi). Users can be away from their desktops while still having access to their computers via pcAnywhere. •Bandwidth auto-detect allows users to optionally detect the actual connection speed of each connection, and adjust settings that affect performance during lower bandwidth connections. •Symantec Packager simplifies pcAnywhere installation and setup, and allows administrators to tailor the solution to best fit the needs of their organization. System requirements Symantec pcAnywhere Windows Host, Remote and Gateway •Windows Vista (Home Basic, Home Premium, Business, Enterprise, Ultimate) •Windows XP (Home, Pro, TabletPC, and Media Center) •Windows XP Embedded and Windows Embedded for POS •Windows 2000 (Professional, Server, Advanced Server) •Windows Server 2003 (Standard and Enterprise) •Windows Server 2008 (Standard and Enterprise) •pcAnywhere Host and Gateway are supported on Windows x64 (AMD64 or EM64T processors only) where applicable Required for all Windows installations •233 MHz or faster processor •128 MB of RAM •35 MB of available hard disk space •CD or DVD drive •Microsoft Internet Explorer® 6.0 SP1 or later Symantec pcAnywhere CrossPlatform Symantec pcAnywhere CrossPlatform Remote •Java™ Runtime Environment 1.4.2 or later •Red Hat® Enterprise Linux® ES or WS 3.0 or 4.0, SUSE™ Enterprise Desktop 9 or 10, or OpenSUSE 10.0 or 10.1 •Mac OS X 10.4 or later (PowerPC® G4 or G5 or Intel® processor) •Windows 2000 or later Symantec pcAnywhere Linux Host •Red Hat Enterprise Linux ES or WS 3.0 or 4.0, SUSE Enterprise Desktop 9 or 10, OpenSUSE 10.0 or 10.1, SUSE Enterprise Server 9 or 10 •KDE® or GNOME™ Symantec pcAnywhere Mac OS X Host •Mac OS X 10.4 or later (PowerPC G4 or G5 or Intel processor) Symantec pcAnywhere Web Remote™ •Java Runtime Environment 1.4.2 or later •Internet Explorer, Mozilla Firefox®, or Safari® Data Sheet: Client and Systems Management Symantec pcAnywhere™ 12.5 Confidence in a connected world. Page 3 of 3 pcAnywhere Mobile •Windows Mobile 2003 SP1 for Pocket PC/Pocket PC Phone Edition or later •1 MB of available RAM for installation •Symantec Packager •Windows Vista (Business, Enterprise, Ultimate) •Windows XP (Professional) •Windows 2000 (Professional, Server, Advanced Server) •Windows Server 2003 (Standard and Enterprise) •Windows Server 2008 (Server and Enterprise) More information Visit our website http://www.symantec.com/business/pcanywhere To speak with a Product Specialist in the U.S. Call toll-free 1 (800) 745 6054 To speak with a Product Specialist outside the U.S. For specific country offices and contact numbers, please visit our website. About Symantec Symantec is a global leader in providing security, storage, and systems management solutions to help businesses and consumers secure and manage their information. Headquartered in Cupertino, Calif., Symantec has operations in more than 40 countries. More information is available at www.symantec.com. Symantec World Headquarters 20330 Stevens Creek Blvd. Cupertino, CA 95014 USA +1 (408) 517 8000 1 (800) 721 3934 www.symantec.com Copyright © 2008 Symantec Corporation. All rights reserved. Symantec, the Symantec logo, and pcAnywhere are trademarks or registered trademarks of Symantec Corporation or its affiliates in the U.S. and other countries. Other names may be trademarks of their respective owners.10/08 14549846 Powering intelligent plant decisions in real time. Analyze OptimizeVisualize TM OVERVIEW Wonderware leads the industry with the broadest set of connectivity options to control hardware and communications protocols needed to support supervisory, plant performance, and production management systems. Connectivity, communications and ease of use are hallmarks of Wonderware's broad line of Device Integration products, which include DAServers (Data Access Servers), Device Integration (DI) Objects, Proxy Objects, I/O Servers, FactorySuite (FS) Gateway, Tag Creators and more. Wonderware's device integration offerings continuously grow and evolve, with new products and enhanced features, such as powerful diagnostics, redundant communications, data level security, native OPC®connectivity and improved deployment capabilities. DEVICE INTEGRATION FEATURES AND BENEFITS Outstanding Integration. DAServers and I/O Servers provide optimum integration with FactorySuite components. Security.ArchestrA Security in FactorySuite A2 Products extends to the data level, so reads and writes to devices and external systems do not have to be customized using scripts. Ease of Use.Thanks to Wonderware'sMicrosoft Management Console DAServer Manager, DAServers can be activated, deactivated, configured and monitored locally or from remote nodes. Built-in Diagnostics.DAServers increase the availability of built-in system diagnostics, for prompt troubleshooting and optimization. Expandable.DAServers are designed for the future. Their unique architecture allows for the easy integration of new client protocols as they emerge. Support For OPC.Wonderware'sFactorySuite A2 product family, enabled by Invensys' ArchestrA™ architecture, provides native client connectivity to OPC Servers. CONNECTIVITY Wonderware has an impressive library of Device Integration solutions for interfacing to a broad range of control and sensor devices on the plant floor… and beyond. More than 800 servers are currently available from Wonderware and more than 100 partner companies, providing connections to PLCs, RTUs, DCSs, flow controllers, loop controllers, scales, gauges, bar code readers and other hardware devices from the biggest names in industrial automation — including Allen- Bradley, Siemens, Modicon and many others. Device Integration Solutions Device Integration Solutions from Wonderware A complete set of connectivity solutions for Industrial Automation Device Integration Solutions DASERVERS The latest addition to Wonderware's DeviceIntegration product family, DAServers, aredesigned to provide simultaneousconnectivity between plant floor devices andmodern DDE, SuiteLink™ and/or OPC basedclient applications. DAServers upport the OPCData Access 2.05 specification and offeradditional features beyond the standard,including powerful diagnostics and remoteconfiguration capabilities. Wonderware constantly adds new and enhanced Device Integration products to our server library. An up-to-date, searchable database of Wonderware and third-party servers is available on Wonderware's corporate web site at: www.wonderware.com/products/connectivity TAKING DEVICE INTEGRATIONTO THE NEXT LEVEL With Wonderware's Industrial ApplicationServer the level of Device Integration isgreatly expanded. This is being done with the introduction of Device Integration (DI)Objects and Proxy Objects. Device Integration (DI) Objects work with DAServers and are designed for applications that connect to Wonderware's Industrial Application Server. They represent the application's network and devices, and mirror the actual device hierarchy. PROXY OBJECTS A Proxy Object is an Automation Object thatrepresents an actual product for the purposeof device integration with the IndustrialApplication Server. For example, there is aProxy Object that enables the IndustrialApplication Server to access an OPC server. The InTouch Proxy Object allows an Industrial Application Server user to browse the Tag Database of an InTouch application and import its data. Extending this functionality, a Proxy Object can represent just about any HMI product. As a result, an Industrial Application Server user can seamlessly integrate HMI products from multiple vendors into one centralized database. EASILY INTEGRATE LEGACY HMI SYSTEMS Wonderware also offers a Proxy Object callediProxy, which enables systems integratorsand end users to tightly integrate GE FanuciFix®and FIX™ 32 HMI installations with theIndustrial Application Server. Using iProxy, auser can consolidate data from existingInTouch, iFIX and FIX 32 databases into onecentralized database. OPEN INTEGRATION Keeping with Wonderware's Tradition of open and easily accessible software products, FactorySuite (FS) Gateway provides a protocol translation capability between SuiteLink/DDE, OPC and InTouch or Industrial Application Server Data Sources. FS Gateway can therefore be used to link legacy SuiteLink/DDE applications into an Industrial Application Server based application or to serve data from InTouch or the Industrial Application Server via OPC. EXTENSIBILITY If a server for your particular device does not yet exist, Wonderware's DAServer Toolkit and Rapid Protocol Modeler (RPM) Kit are available to help you develop your own custom solution. What this means is that every device — on the factory floor or in the field — can connect to Wonderware applications, providing a smooth, uninterrupted flow of data. Contact Wonderware or your local Distributor for information about software products for industrial automation. Wonderware Corporation • 26561 Rancho Parkway South, Lake Forest, CA 92630 • Tel: (949) 727-3200 • Fax: (949) 727-3270www.wonderware.com ©2004 Invensys Systems, Inc. All rights reserved. No part of the material protected by this copyright may be reproduced or utilized in any form or by any means, electronic ormechanical, including photocopying, recording, broadcasting, or by any information storage and retrieval system, without permission in writing from Invensys Systems, Inc. Invensys, Wonderware, InTouch, SuiteLink and ArchestrA are trademarks of Invensys plc, its subsidiaries and affiliated companies. All other brands and product names may bethe trademarks of their respective owners. PN 15-0126 Rev. 8/04