Loading...
HomeMy WebLinkAboutTab 1 - ControlLogix CutsCatalogs > Automation Systems Catalog > Programmable Controllers > ControlLogix System > ControlLogix Controllers CONTROLLOGIX CONTROLLERS Introduction Available 1756 Controllers Controller Memory Use Battery Requirements Compatibility Available 1756 Controllers Cat. No. Memory Power Dissipation, Max. Thermal Dissipation, Max. Backplane Current (mA) at 5V Backplane Current (mA) at 24V Available User Memory (Kbytes) I/O Memory Nonvolatile Memory 1756-L55M12 750K bytes 208 K bytes NA 5.6 W 19.1 BTU/hr 1230mA 14mA 1756-L55M13 1536K bytes 208 K bytes NA 5.6 W 19.1 BTU/hr 1230mA 14mA 1756-L55M14 3584K bytes 208 K bytes NA 5.7 W 19.4 BTU/hr 1250mA 14mA 1756-L55M16 7680K bytes ‡ 208 K bytes NA 6.3 W 21.5 BTU/hr 1480mA 14mA 1756-L55M22 750K bytes 208 K bytes 750 Kbytes 5.6 W 19.1 BTU/hr 1230mA 14mA 1756-L55M23 1536K bytes 208 K bytes 1.5 Mbytes 5.6 W 19.1 BTU/hr 1230mA 14mA 1756-L55M24 3584K bytes 208 K bytes 3.5 Mbytes 5.7 W 19.4 BTU/hr 1250mA 14mA 1756-L61 2048K bytes 478 K bytes 64 Mbytes CompactFlash§ 3.5 W 11.9 BTU/hr 1200mA 14mA 1756-L61S 2048 KB Standard 1024 KB Safety 478 KB 64 MB CompactFlash 3.5 W 11.9 BTU/hr 1200mA 14mA 1756-L62 4096K bytes 478 K bytes 64 Mbytes CompactFlash§ 3.5 W 11.9 BTU/hr 1200mA 14mA 1756-L62S 4096 KB Standard 1024 KB Safety 478 KB 64 MB CompactFlash 3.5 W 11.9 BTU/hr 1200mA 14mA 1756-L63 8196K bytes 478 K bytes 64 Mbytes CompactFlash§ 3.5 W 11.9 BTU/hr 1200mA 14mA 1756-L64 16,384 K bytes 478 K bytes 64 Mbytes CompactFlash§ 3.5 W 11.9 BTU/hr 1200mA 14mA 1756-L60M03SE 478 K bytes 64 Mbytes CompactFlash§ 8.5 W 11.9 BTU/hr 1960 mA 6mA 1756-LSP NA - Safety Partner NA NA 3.5 W 11.9 BTU/hr 1200mA 14mA Data and Logic memory stores: tags other than I/O, produced, or consumed tags; logic routines; and communication with OPC/DDE tags Page 1 of 2ControlLogix Controllers 12/30/2008http://www.ab.com/en/epub/catalogs/12762/2181376/2416247/360807/1837516/tab2.html The 1756-L6x controller executes ladder scans almost twice as fast as the 1756-L55 controllers and executes function block, REAL data type math, and motion instructions four to five times faster than the 1756-L55 controllers. The 1756-L60M03SE controller combines a 1756-L6x controller and a SERCOS motion module in a two-slot module. This controller is ideal for small motion systems and can control three SERCOS axes with the included interface. This controller can control as many as six axes if you add an additional motion module. that use RSLinx software. I/O memory stores: I/O tags, produced tags, consum ed tags, communication via Message (MSG) instructions, communication with workstations, and communication with OPC/DDE tags that use RSLinx software. ‡No more than 3500 Kbytes of data. §Requires a 1784-CF64 Industrial CompactFlash card . The 1756-L60M03SE is a 1756-L60 ControlLogix contr oller with an embedded 1756-M03SE SERCOS interface. This is a 2-slot module. Select a Controller for a Redundant Controller System If you are designing a redundant controller system, consider: redundant controller systems support one or two 1756-L55 controllers or one 1756-L6x controller in each redundant chassis. data is buffered in the secondary controller, so twice as much data memory space is required in the controller. the redundant controllers must be on a ControlNet network. Select a Controller for a Safety System If you are designing a safety controller system, consider: SIL 2 safety systems use standard ControlLogix controllers. See Using ControlLogix in SIL 2 Applications Safety Reference Manual, publication 1756-RM001. SIL 3 safety systems use GuardLogix controllers (1756-L61S, 1756-L62S) and the Safety Partner (1756-LSP). See GuardLogix Controllers Systems Safety Reference Manual, publication 1756-RM093. Copyright © 2008 Rockwell Automation, Inc.All Rig hts Reserved. Page 2 of 2ControlLogix Controllers 12/30/2008http://www.ab.com/en/epub/catalogs/12762/2181376/2416247/360807/1837516/tab2.html Catalogs > Automation Systems Catalog > Programmable Controllers > ControlLogix System > ControlLogix Chassis CONTROLLOGIX CHASSIS Introduction 1756 Chassis Minimum Spacing Requirements Mounting Dimensions 1756 Chassis All of the chassis are designed for back-panel mounting. Use the slot filler module, 1756-N2, to fill empty slots. Copyright © 2008 Rockwell Automation, Inc.All Rig hts Reserved. Cat. No. Weight, Approx. Dimensions (HxWxD), Approx. Cabinet Size (HxWxD) Backplane Current (mA) 1756-A4 0.75 kg (1.7 lb) 137 x 263 x 145 mm (5.4 x 10.4 x 5.8 in.) 508 x 508 x 203 mm (20 x 20 x 8 in.) 4.0 @ 3.3V dc 15.0A @ 5V dc 2.8A @ 24V dc 1756-A7 1.10 kg (2.4 lb) 137 x 368 x 145 mm (5.4 x 14.5 x 5.8 in.) 508 x 610 x 203 mm (20 x 24 x 8 in.) 1756-A10 1.45 kg (3.2 lb) 137 x 483 x 145 mm (5.4 x 19.0 x 5.8 in.) 508 x 762 x 203 mm (20 x 30 x 8 in.) 1756-A13 1.90 kg (4.2 lb) 137 x 588 x 145 mm (5.4 x 23.2 x 5.8 in.) 610 x 762 x 203 mm (24 x 30 x 8 in.) 1756-A17 2.20 kg (4.8 lb) 137 x 738 x 145 mm (5.4 x 29.1 x 5.8 in.) 762 x 914 x 203 mm (30 x 36 x 8 in.) Certifications: UL, CSA (Class I, Division 2, Group A, B, C, D), CE, FM Page 1 of 1ControlLogix Chassis 12/30/2008http://www.ab.com/en/epub/catalogs/12762/2181376/2416247/360807/2387363/tab2.html Catalogs > Automation Systems Catalog > Programmable Controllers > ControlLogix System > ControlLogix Chassis CONTROLLOGIX CHASSIS Introduction 1756 Chassis Minimum Spacing Requirements Mounting Dimensions Mounting Dimensions Right-side View of Chassis 1756-A4 with Power Supply 1756-A7 with Power Supply Page 1 of 3ControlLogix Chassis 12/30/2008http://www.ab.com/en/epub/catalogs/12762/2181376/2416247/360807/2387363/tab4.html 1756-A10 with Power Supply 1756-A13 with Power Supply Page 2 of 3ControlLogix Chassis 12/30/2008http://www.ab.com/en/epub/catalogs/12762/2181376/2416247/360807/2387363/tab4.html 1756-A17 with Power Supply Copyright © 2008 Rockwell Automation, Inc.All Rig hts Reserved. Page 3 of 3ControlLogix Chassis 12/30/2008http://www.ab.com/en/epub/catalogs/12762/2181376/2416247/360807/2387363/tab4.html Catalogs > Automation Systems Catalog > Programmable Controllers > ControlLogix System > Power Supplies POWER SUPPLIES Introduction Standard Power Supply Redundant Power Supply Standard Power Supply You mount a standard power supply directly on the left end of the chassis, where it plugs directly into the backplane. The power supply you select can determine which chassis you can use. Attribute Power Supplies 1756- PA72/C 1756- PA75/B 1756- PB72/C 1756- PB75/B 1756-PC75/B 1756-PH75/B Power Supply Input Voltage, Nom. 120/240 V ac 120/240 V ac 24V dc 24V dc 48V dc 125V dc Operating Voltage Range 85…265V ac 85…265V ac 18...32V dc 18...32V dc 30…60V dc 90…143V dc Input Power, Max. 100V A / 100 W 100V A / 100 W 95 W 95 W 95 W 95 W Input Frequency Range 47…63 Hz 47…63 Hz dc dc dc dc Current Capacity, Max. 1.5 A @ 1.2V dc 4.0 A @ 3.3V dc 10.0A‡ @ 5V dc 2.8A‡ @ 24V dc 1.5 A @ 1.2V dc 4.0 A @ 3.3V dc 13.0A‡ @ 5V dc 2.8A‡ @ 24V dc 1.5 A @ 1.2V dc 4.0 A @ 3.3V dc 10.0A‡ @ 5V dc 2.8A‡ @ 24V dc 1.5 A @ 1.2V dc 4.0 A @ 3.3V dc 13.0A‡ @ 5V dc 2.8A‡ @ 24V dc 1.5 A @ 1.2V dc 4.0 A @ 3.3V dc 13A‡ @ 5V dc 2.8A‡ @ 24V dc 1.5 A @ 1.2V dc 4.0 A @ 3.3V dc 13A‡ @ 5V dc 2.8A‡ @ 24V dc Power Supply Output Current Rating 75 W @ 60 °C (140 °F) 75 W @ 60 °C (140 °F) 75 W @ 60 °C (140 °F) 75 W @ 60 °C (140 °F) 75 W @ 60 °C (140 ° F) 75 W @ 60 °C (140 ° F) Hold Up Time 5 cycles @ 85V ac, 50/60 Hz 6 cycles @ 120V ac, 50/60 Hz 6 cycles @ 200V ac, 50/60 Hz 6 cycles @ 240V ac, 50/60 Hz 35 ms @ 18 V dc 40 ms @ 24 V dc 40 ms @ 32 V dc 50 ms @ 30…60V dc nom 50 ms @ 90…143V dc nom§ Chassis Compatibility Series A Series B Series B Series A Series B Series B Series B Series B Mounting Location Left side of 1756 chassis Left side of 1756 chassis Left side of 1756 series B chassis Left side of 1756 series B chassis Certifications: UL, CSA (Class I, Division 2, Group A, B, C, D), CE, FM, C-Tick The hold up time is the time between input voltage removal and dc power failure. Input may drop to 16V for a maximum of two minutes each hour for motor starting. Standard Power Load and Transformer Sizing Use these graphs to determine the input power requirements for the supplies, given the power they are providing to the modules in the chassis. The vertical axis of each graph shows the backplane power consumed by all of the modules in the chassis; the horizontal axis shows input power requirements of the power supply. To use the graphs: Page 1 of 2Power Supplies 12/30/2008http://www.ab.com/en/epub/catalogs/12762/2181376/2416247/360807/1837526/tab2.html 1. Add all of the backplane power (watts) for all of the modules in the chassis. 2. Find the number from step 1 on the vertical axis. 3. Follow that value to the right until it intersects the line on the graph. 4. Find the associated input power rating consumed by the power supply on the horizontal axis. For example, if the power consumption of all of the modules in the chassis is 30 watts, a 1756-PB75/B consumes approximately 40 watts of Real Power. Copyright © 2008 Rockwell Automation, Inc.All Rig hts Reserved. Page 2 of 2Power Supplies 12/30/2008http://www.ab.com/en/epub/catalogs/12762/2181376/2416247/360807/1837526/tab2.html Catalogs > Automation Systems Catalog > Programmable Controllers > ControlLogix System > Networks NETWORKS Introduction Available Networks EtherNet/IP Network ControlNet Network DeviceNet Network Safety Networks DH+ and Remote I/O Networks FOUNDATION Fieldbus Network Serial Network DH-485 Network EtherNet/IP Network The Ethernet Industrial (EtherNet/IP) network protocol is an open industrial-networking standard that supports both real-time I/O messaging and message exchange. It emerged due to the high demand for using the Ethernet network for control applications. The EtherNet/IP network uses off-the-shelf Ethernet communication chips and physical media. The EtherNet/IP network provides excellent drive and I/O control performance along with HMI information processing and many commercial technologies. Select an EtherNet/IP Interface Select the appropriate controller and EtherNet/IP interface depending on the application and how the controller interacts with the devices. If your application Select this interface Description Controls I/O modules Requires an adapter for disibuted I/O on EtherNet/IP links Communicates with other EtherNet/IP devices (messages) Bridges EtherNet/IP links to route messages to devices on other networks 1756-EN2F 1756-EN2T 1756-ENBT The EtherNet/IP communication module: controls I/O over an EtherNet/IP network. acts as an adapter for distributed I/O on remote EtherNet/IP links. routes messages to devices on other networks. Requires remote access via an Internet browser to tags in a local ControlLogix controller Communicates with other EtherNet/IP or generic Ethernet devices (messages) 1756-EWEB The enhanced Web-server module provides Internet browser access so you can monitor and modify data remotely via XML Web pages. The Web- server module supports: data access (read and write) to ControlLogix controllers. bridging and routing of messages. Page 1 of 3Networks 12/30/2008http://www.ab.com/en/epub/catalogs/12762/2181376/2416247/360807/1837522/tab3.html Bridges EtherNet/IP links to route messages to devices on other networks custom Web pages. email capability. open socket services. EtherNet/IP Interface Specifications Cat. No. Communication Rate Connections Power Dissipation, Max. Backplane Current (mA) at 5V Backplane Current (mA) at 24V 1756-EN2F 10/100 Mbps Each module supports a maximum of: 128 TCP/IP connections. 256 Logix connections (I/O and information). 5.1 W 1 A 3 mA 1756-EN2T 5.1 W 1 A 3 mA 1756-ENBT 10/100 Mbps Each module supports a maximum of: 64 TCP/IP connections. 128 Logix connections (I/O and information). 3.65 W 700mA 3mA 1756-EWEB 3.65 W 700 mA 3 mA Certifications: UL, CSA (Class I, Division 2, Group A, B, C, D), CE, FM, C-Tick Typical EtherNet/IP Configuration Page 2 of 3Networks 12/30/2008http://www.ab.com/en/epub/catalogs/12762/2181376/2416247/360807/1837522/tab3.html Copyright © 2008 Rockwell Automation, Inc.All Rig hts Reserved. Page 3 of 3Networks 12/30/2008http://www.ab.com/en/epub/catalogs/12762/2181376/2416247/360807/1837522/tab3.html Catalogs > Automation Systems Catalog > Programmable Controllers > ControlLogix System > 1756 ControlLogix I/O 1756 CONTROLLOGIX I/O Introduction Digital I/O Analog I/O Specialty I/O HART Smart Instrumentation Removable Terminal Blocks Digital I/O The 1756 digital I/O modules support these features. Variety of voltage interface capabilities Isolated and non-isolated module types Point-level output fault states Direct-connect or rack-optimized communication Field-side diagnostics on select modules In addition, you can select these types of digital I/O modules. Digital I/O Type Description Diagnostic These modules provide diagnostic features to the point level. These modules have a D at the end of the catalog number. Electronic fusing These modules have internal electronic fusing to prevent too much current from flowing through the module. These modules have an E at the end of the catalog number. Individually isolated These modules have individually isolated inputs or outputs. These modules have an I at the end of the catalog number. 1756 Digital ac Input Modules Cat. No. Number of Inputs Voltage, On-State Input, Nom. Operating Voltage Input Delay Time, ON to OFF Current, On-State Input, Min. Current, On-State Input, Max. Current, Off-State Input, Max. Removable Terminal Block Housing Backplane Current (mA) at 5V Backplane Current (mA) at 24V Power Dissipation, Max. 1756-IA8D 8 diagnostic 120V ac 79...132V ac Hardware: 8 ms, max (plus filter time) Programmable filter: 9 ms or 18 ms 5 mA @ 79V ac 16 mA @ 132V ac 2.5 mA 1756-TBNH 1756-TBSH 100mA 3mA 4.5 W @ 60 °C 1756-IA16 16 120V ac 74...132V ac Hardware: 8 ms, max (plus filter time) Programmable filter: 9 ms or 18 ms 5 mA @ 74V ac 13 mA @ 132V ac 2.5 mA 1756-TBNH 1756-TBSH 105mA 2mA 5.8 W @ 60 °C 1756-IA16I 16 individually isolated 120V ac 79...132V ac Hardware: 8 ms, max (plus filter time) Programmable filter: 9 ms or 18 ms 5 mA @ 79V ac 47…63Hz 15 mA @ 132V ac, 47…63HZ 2.5 mA 1756-TBCH 1756-TBS6H 125mA 3mA 4.9 W @ 60 °C 1756-IA32 32 120V ac 74...132V ac Programmable filter: 9ms & 18 ms 5 mA @ 74V ac 10 mA @ 132V ac 2.5 mA 1756-TBCH 1756-TBS6H 165 mA 2 mA 6.1 W @ 60°C 1756-IM16I 16 individually isolated 240V ac 159...265V ac Hardware: 8 ms, max (plus filter time) Programmable filter: 9 ms or 18 ms 5 mA @ 159V ac, 60Hz 13 mA @ 265V ac, 60Hz 2.5 mA 1756-TBCH 1756-TBS6H 100mA 3mA 5.8 W @ 60 °C 1756-IN16 16 24V ac 10...30V ac Hardware: 10 ms, max (plus filter time) Programmable filter: 9 ms or 18 ms 5 mA @ 10V ac, 60 Hz 1.2 mA @ 30V ac, 60 Hz 2.75 mA 1756-TBNH 1756-TBSH 100mA 2mA 5.1 W @ 60 °C Page 1 of 41756 ControlLogix I/O 12/30/2008http://www.ab.com/en/epub/catalogs/12762/2181376/2416247/360807/2284181/tab2.html 1756 Digital ac Output Modules Cat. No. Number of Outputs Voltage Category Operating Voltage Output Current Rating, per Point, Max. Output Continuous Current per Module, Max. Removable Terminal Block Housing Backplane Current (mA) at 5V Backplane Current (mA) at 24V Power Dissipation, Max. 1756-OA8 8 120/240V ac 74...265V ac 2 A @ 60 °C (Linear derating) 5 A @ 30 °C (Linear derating) 4 A @ 60 °C (Linear derating) 1756-TBNH 1756-TBSH 200mA 2mA 5.1 W @ 60 °C 1756-OA8D 8 diagnostic 120V ac 74...132V ac 1 A @ 30 °C (Linear derating) 0.5 A @ 60 °C (Linear derating) 8 A @ 30 °C (Linear derating) 4 A @ 60 °C (Linear derating) 1756-TBNH 1756-TBSH 175mA 250mA 5.3 W @ 60 °C 1756-OA8E 8 electronic fusing 120V ac 74...132V ac 2 A @ 60 °C 8 A @ 30 °C (Linear derating) 4 A @ 60 °C (Linear derating) 1756-TBNH 1756-TBSH 200mA 250mA 5.5 W @ 60 °C 1756-OA16 16 120/240V ac 74...265V ac 0.5 A @ 60 °C 4 A @ 60 °C 1756-TBNH 1756-TBSH 400mA 2mA 6.5 W @ 60 °C 1756-OA16I 16 individually isolated 120/240V ac 74...265V ac 2 A @ 30 °C (Linear derating) 1 A @ 60 °C (Linear derating) 5 A @ 30 °C (Linear derating) 4 A @ 60 °C (Linear derating) 1756-TBCH 1756-TBS6H 300mA 3mA 5.5 W @ 60 °C 1756-ON8 8 24 V ac 10...30V ac 2 A @ 60 °C 5 A @ 30 °C 4 A @ 60 °C (Linear derating) 1756-TBNH 1756-TBSH 200mA 2mA 5.1 W @ 60 °C 1756 Digital dc Input Modules Cat. No. Number of Inputs Voltage, On-State Input, Nom. Operating Voltage Input Delay Time, ON to OFF Current, On- State Input, Min. Current, On- State Input, Max. Current, Off- State Input, Max. Removable Terminal Block Housing Backplane Current (mA) at 5V Backplane Current (mA) at 24V Power Dissipation, Max. 1756-IB16 16 12/24V dc sink 10...31.2V dc 2 ms hardware + filter time (0, 1, 2, 9, or 18 ms) 2.0 mA @ 10V dc 10 mA @ 31.2V dc 1.5 mA 1756-TBNH 1756-TBSH 100mA 2mA 5.1 W @ 60 ° C 1756-IB16D 16 diagnostic 12/24V dc sink 10...30V dc 4 ms hardware + filter time (0, 1, 2, 9, or 18 ms) 2 mA @ 10V dc 13 mA @ 30V dc 1.5 mA/point 1756-TBCH 1756-TBS6H 150mA 3mA 5.8 W @ 60 ° C 1756-IB16I 16 individually isolated 12/24V dc sink/source 10...30V dc 4 ms hardware + filter time (0, 1, 2, 9, or 18 ms) 2 mA @ 10 V dc 10 mA @ 30V dc 1.5 mA 1756-TBCH 1756-TBS6H 100mA 3mA 5 W @ 60 °C 1756-IB16ISOE 16 individually isolated; sequence of events 24/48V dc sink/source 10...55V dc 50 µs hardware + filter time (0...50 ms) 5.5 mA @ 55V dc 2 mA @ 10V dc 1.5 mA 1756-TBCH 1756-TBS6H 275 mA 2 mA 5.5 W @ 60 ° C 1756-IB32 32 12/24V dc sink 10...31.2V dc 420 µs + filter time (0, 1, 2, 9, or 18 ms) 2 mA 5.5 mA 1.5 mA 1756-TBCH 1756-TBS6H 120 mA 2mA 6.2 W @ 60 ° C 1756-IC16 16 48V dc sink 30...60V dc 4 ms hardware + filter time (0, 1, 2, 9, or 18 ms) 2 mA @ 30V dc 7 mA @ 60V dc 1.5 mA 1756-TBNH 1756-TBSH 100mA 3mA 5.2 W @ 60 ° C Page 2 of 41756 ControlLogix I/O 12/30/2008http://www.ab.com/en/epub/catalogs/12762/2181376/2416247/360807/2284181/tab2.html 1756-IG16 16 (8 points/common) 5V dc TTL source 4.5...5.5V dc .25 ms hardware + filter time (0, 1, 2, 9, or 18 ms) — — 4.1 mA 1756-TBNH 1756-TBSH 110mA 2mA 1.4 W @ 60 ° C 1756-IH16I 16 individually isolated 125V dc sink/source 90...146V dc 6 ms hardware + filter time (0, 1, 2, 9, or 18 ms) 1 mA @ 90V dc 3 mA @ 146V dc 0.8 mA 1756-TBCH 1756-TBS6H 125mA 3mA 5 W @ 60 °C 1756-IH16ISOE 16 individually isolated; sequence of events 125V dc sink/source 90...140V dc 75 µs hardware + filter time (0...50 ms) 1.15 mA @ 90V dc 1.85 mA @ 140V dc 0.3 mA 1756-TBCH 1756-TBS6H 275 mA 2 mA 5.5 W @ 60 ° C 1756-IV16 16 12/24V dc source 10...30V dc 2 ms hardware + filter time (0, 1, 2, 9, or 18 ms) 2.0 mA @ 10V dc 10 mA @ 30V dc 1.5 mA 1756-TBNH 1756-TBSH 110mA 2mA 5.41 W @ 60 ° C 1756-IV32 32 12/24V dc source 10...30V dc 2 ms hardware + filter time (0, 1, 2, 9, or 18 ms) 2 mA @ 10V dc 3.5 mA @ 30V dc 1.5 mA 1756-TBCH 1756-TBS6H 120mA 2mA 4.1 W @ 60 ° C 1756 Digital dc Output Modules Cat. No. Number of Outputs Voltage Category Operating Voltage Output Current Rating, per Point, Max. Output Continuous Current per Module, Max. Removable Terminal Block Housing Backplane Current (mA) at 5V Backplane Current (mA) at 24V Power Dissipation, Max. 1756-OB8 8 12/24V dc source 10...30V dc 2.0 A @ 60 °C 8.0 A @ 60 °C 1756-TBNH 1756-TBSH 165mA 2mA 2.5 W @ 60 °C 1756-OB8EI 8 electronically fused, individually isolated 12/24V dc source 10...30V dc 2 A @ 60 °C 16.0 A @ 55 °C (Linear derating) 10.0 A @ 60 °C 1756-TBCH 1756-TBS6H 250mA 2mA 4.7 W @ 60 °C 1756-OB8I 8 individually isolated 12/24V dc source 10...30V dc 2.0 A @ 60 °C 16.0 A @ 60 °C 1756-TBCH 1756-TBS6H 165 mA 2mA 4.6W A @ 60 °C 1756-OB16D 16 diagnostic 24V dc source 19.2...30V dc 2 A @ 30 °C (Linear derating) 1 A @ 60 °C (Linear derating) 8 A @ 30 °C (Linear derating) 4 A @ 60 °C (Linear derating) 1756-TBCH 1756-TBS6H 250mA 140mA 3.3 W @ 60 °C 1756-OB16E 16 electronically fused 12/24V dc source 10...31.2V dc 1 A @ 60 °C 8 A @ 60 °C 1756-TBNH 1756-TBSH 250mA 2mA 4.1 W @ 60 °C 1756-OB16I 16 individually isolated 12/24V dc sink/source 10...30V dc 2 A @ 30 °C (Linear derating) 1 A @ 60 °C (Linear derating) 8 A @ 30 °C (Linear derating) 4 A @ 60 °C (Linear derating) 1756-TBCH 1756-TBS6H 350mA 3mA 3.6 W @ 60 °C 1756-OB16IS 16 individually isolated; 8 scheduled 12/24V dc sink/source 10...30V dc 2 A @ 30 °C 1 A @ 60 °C (Linear derating) 8 A @ 30 °C 4 A @ 60 °C (Linear derating) 1756-TBCH 1756-TBS6H 350mA 2.5mA 3.6 W @ 60 °C 1756-OB32 32 12/24V dc source 10...31.2V dc 0.5 A @ 50 °C (Linear derating) 0.35 A @ 60 ° C 16 A @ 50 °C (Linear derating) 10 A @ 60 °C 1756-TBCH 1756-TBS6H 300mA 2mA 4.8 W @ 60 °C 1756-OC8 8 48V dc source 30...60V dc 2.0 A @ 60 °C 8.0 A @ 60 °C 1756-TBNH 1756-TBSH 165mA 2mA 4.9 W @ 60 °C 1756-OG16 16 5V dc TTL 4.5...5.5V dc 24 mA @ 60 °C 384 mA @ 60 °C 1756-TBNH 1756-TBSH 210mA 2mA 1.5 W @ 60 °C 1756-OH8I 8 120V dc 90...146V dc 2 A @ 60 °C 8 A @ 60 °C 1756-TBCH 210mA 2mA 3.3 W @ 60 °C Page 3 of 41756 ControlLogix I/O 12/30/2008http://www.ab.com/en/epub/catalogs/12762/2181376/2416247/360807/2284181/tab2.html individually isolated sink/source 1756-TBS6H 1756-OV16E 16 electronically fused 12/24V dc sink 10...30V dc 1 A @ 60 °C 8 A @ 60 °C 1756-TBNH 1756-TBSH 210mA 2mA 6.72 W @ 60 °C 1756-OV32E 32 electronically fused 12/24V dc sink 10...30V dc 0.5 A @ 50 °C (Linear derating) 0.35 A @ 60 ° C 16.0 A @ 50 °C (Linear derating) 10.0 A @ 60 °C 1756-TBCH 1756-TBS6H 390mA 2mA 5.88 W @ 60 °C 1756 Digital Contact Output Modules Copyright © 2008 Rockwell Automation, Inc.All Rig hts Reserved. Cat. No. Number of Outputs Output Delay Time, ON to OFF, Max. Type of Contact Output Operating Voltage Output Current Removable Terminal Block Housing Backplane Current (mA) at 5V Backplane Current (mA) at 24V Power Dissipation, Max. 1756-OW16I 16 individually isolated 10 ms 16 N.O. 10...265V ac 5...150V dc 2 A @ 5… 30V dc 0.5 A @ 48V dc 0.25 A @ 125V dc 2 A @ 125/240V ac 1756-TBCH 1756-TBS6H 150mA 150mA 4.5 W @ 60 °C 1756-OX8I 8 individually isolated 13 ms 1 set of form-C contacts for each output 10...265V ac 5...150V dc 2 A @ 5… 30V dc 0.5 A @ 48V dc 0.25 A @ 125V dc 2 A @ 125/240V ac 1756-TBCH 1756-TBS6H 100mA 100mA 3.1 W @ 60 °C Page 4 of 41756 ControlLogix I/O 12/30/2008http://www.ab.com/en/epub/catalogs/12762/2181376/2416247/360807/2284181/tab2.html Catalogs > Automation Systems Catalog > Programmable Controllers > ControlLogix System > 1756 ControlLogix I/O 1756 CONTROLLOGIX I/O Introduction Digital I/O Analog I/O Specialty I/O HART Smart Instrumentation Removable Terminal Blocks Analog I/O The 1756 analog I/O modules support these features. On-board data alarming Scaling to engineering units Real-time channel sampling IEEE 32-bit floating point or 16-bit integer data formats 1756 Analog Modules Cat. No. Number of Inputs Number of Outputs Resolution Sensors Supported Removable Terminal Block Housing Backplane Current (mA) at 5V Backplane Current (mA) at 24V Power Dissipation, Max. 1756-IF8 8 single- ended,4 differential,2 high-speed differential,, — 16 bits ±10.25V 0...5.125V 0...10.25V 1756-TBCH 1756-TBS6H 150mA 40mA 1.73 W - Voltage 2.33 W - Current 1756-IF6CIS 6 isolated, current sourcing — 16 bits 0...21mA Range 1756-TBNH 1756-TBSH 250mA 275mA 5.1 W @ 60 ° C 1756-IF6I 6 isolated — 16 bits ±10.5V 0...5.25V 0...10.5V 1756-TBNH 1756-TBSH 250mA 100mA 3.7 W - Voltage 4.3 W - Current 1756-IF16 8 differential,4 high-speed differential,16 single- ended,, — 16 bits ±10.25V 0...5.125V 0...10.25V 1756-TBCH 1756-TBS6H 150mA 65mA 2.3 W - Voltage 3.9 W - Current 1756-IF4FXOF2F 4 high-speed, sub- millisecond, differential 2 high- speed voltage or current 14 bits Inputs ±10.5V 0...5.25V 0...10.5V Outputs ±10.5V 1756-TBCH 1756-TBS6H 375mA 100mA 4.3 W - Voltage 4.7 W - Current 1756-IR6I 6 isolated RTD — 16 bits 100, 200, 500, 1000 Platinum, alpha=385 100, 200, 500, 1000 1756-TBNH 1756-TBSH 250mA 125mA 4.3 W Page 1 of 21756 ControlLogix I/O 12/30/2008http://www.ab.com/en/epub/catalogs/12762/2181376/2416247/360807/2284181/tab3.html Copyright © 2008 Rockwell Automation, Inc.All Rig hts Reserved. Platinum, alpha=3916 120 Nickel, alpha=672 100, 120, 200, 500 Nickel, alpha=618 10 Copper 1756-IT6I 6 isolated thermocouple 1 CJC — 16 bits -12 mV... +78 mV -12 mV... +38 mV Thermocouples: B, E, J, K, R, S, T, N, C 1756-TBNH 1756-TBSH 250mA 125mA 4.3 W 1756-IT6I2 6 isolated thermocouple 2 CJC — 16 bits -12 mV... +78 mV -12 mV... +38 mV Thermocouples: B, E, J, K, R, S, T, N, C, L, D 1756-TBNH 1756-TBSH 200mA 120mA 3.9 W 1756-OF4 — 4 voltage or current 15 bits — 1756-TBNH 1756-TBSH 150mA 120mA 3.25 W - 4 channel current 1756-OF6CI — 6 isolated current 13 bits — 1756-TBNH 1756-TBSH 250mA 300mA 5.5 W (0…550 loads) 6.1 W (551… 1000 loads) 1756-OF6VI — 6 isolated voltage 14 bits — 1756-TBNH 1756-TBSH 250mA 175mA 4.85 W 1756-OF8 — 8 voltage or current 15 bits — 1756-TBNH 1756-TBSH 150mA 210mA 4.92 W - 4 channel current Page 2 of 21756 ControlLogix I/O 12/30/2008http://www.ab.com/en/epub/catalogs/12762/2181376/2416247/360807/2284181/tab3.html