Loading...
HomeMy WebLinkAboutTab 2 - Allen Bradley Power Supply1 Publication 1606-AP013A-EN-E March 2003 • World-wide approvals ( ) for industry, factory mutual rating • Input: AC 230/115V, DC 240...375V • Output: 24...28V/240 W • Power boost up to 288W • High overload current, no switch-off • Robust mechanics and EMC Application Note 1606-XL240E Input Efficiency, Reliability etc. Start / Overload Behavior Output Input voltage AC 100...120/200...240V (switchable), 47...63Hz (AC 85...132/176...264V, DC 240...375V) Note: At DC input, always leave the switch in the 230V position Input current <6A (switch in 115V position) <2.6A (switch in 230V position) • DCin at open output 8mA (preserves battery sources) Inrush current typ. <30A at AC 264V and cold start If you intend to protect the primary side of the power supply with a fuse or a circuit breaker, a 10 A slow acting fuse (HBC) or a supplementary protector 1492- SPU1C100 is recommended. In order to meet local requirements, please consult lo- cal codes and regulations for proper installation. Transient handling Transient resistance acc. to VDE 0160 / W2 (750V/ 1.3ms), for all load conditions. Hold up time >25ms at AC 196V, 24V/10A (see diagram) Efficiency typ. 90% (AC 230V, 24V/10A) Losses typ. 26.7W (AC 230V, 24V/10A) MTBF 425.000h acc. to Siemensnorm SN 29500 (24V/10A, AC 230V, Tamb = +40°C) Life cycle (electrolytics) The unit exclusively uses longlife electrolytics, speci- fied for +105°C. Startup delay typ. 0.1s Rise time ca. 5...20ms, depending on load Overload Behavior • Special Overload Design (see diagram) – no disconnection, no hiccup if overloaded – high overload current (up to 1.6 INom), Vout is grad- ually reduced with increasing current. • 20% power boost – 12A short-term, at 45°C or forced cooling even con- tinuous Advantages: • High short-circuit current, giving large ‘start-up window’: unit starts reliably even with awkward loads (DC-DC converters, motors). • No ‘sticking’ such as can occur with fold-back characteristics • Secondary fuses operate more reliably Output voltage DC 24...28V, adjustable by (covered) front panel poten- tiometer; preset: 24.5V ±0.5% Adj. range guaranteed Output noise suppression Radiated EMI values below EN50081-1, even when us- ing long, unscreened output cables. Ambient temperature range Tamb Operation: 0°C...+70°C (>60°C: Derating) Storage: -25°C...+85°C Rated continuous loading with convection cooling •Tamb=0°C - 60°C •Tamb=0°C - 45°C 24V/10A (240W) resp. 28V/8.6A (240W) 24V/12A (288W) resp. 28V/10.3A (288W) short-term also at 60°C Output is protected against short-circuit, open circuit and overload Derating typ. 6W/K (at Tamb= +60°C...+70°C) Voltage regulation better than 2% Vout overall Ripple / Noise <30mVPP, (20MHz bandwidth, 50Ω measurement) Overvolt. protection typ. 35V Parallel operation yes, load sharing available on request Power back immunity 34V Front panel indicator Green LED on front panel Publication 1606-AP013A-EN-E March 2003  2003 Rockwell International. All Rights Reserved. Printed in US 2 Application Note www.rockwellautomation.com Corporate Headquarters Rockwell Automation, 777 East Wisconsin Avenue, Suite 1400, Milwaukee, WI, 53202-5302 USA, Tel: (1) 414.212.5200, Fax: (1) 414.212.5201 Headquarters for Allen-Bradley Products, Rockwell Software Products and Global Manufacturing Solutions Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444Europe: Rockwell Automation SA/NV, Vorstlaan/Boulevard du Souverain 36-BP 3A/B, 1170 Brussels, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640 Asia Pacific: Rockwell Automation, 27/F Citicorp Centre, 18 Whitfield Road, Causeway Bay, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846 Headquarters for Dodge and Reliance Electric Products Americas: Rockwell Automation, 6040 Ponders Court, Greenville, SC 29615-4617 USA, Tel: (1) 864.297.4800, Fax: (1) 864.281.2433Europe: Rockwell Automation, Brühlstraße 22, D-74834 Elztal-Dallau, Germany, Tel: (49) 6261 9410, Fax: (49) 6261 1774 Asia Pacific: Rockwell Automation, 55 Newton Road, #11-01/02 Revenue House, Singapore 307987, Tel: (65) 351 6723, Fax: (65) 355 1733 Construction / Mechanics Housing dimensions and Weight • W x H x D • Free space for ventilation •Weight 120mm x 124mm x 102mm (+ DIN rail) above/below 25mm recommended left/right 15mm recommended 980g Design advantages: • All connection blocks are easy to reach as mounted at the front panel. Wire Size Input/Output: • Stranded 20...10 AWG (0.5...4 mm²), Solid 20...10 AWG (0.5...6 mm²) Tightening Torque: 7 lbs in (0.8 Nm) recommended Efficiency (typ.) Hold-up time (typ., at Vout=24V) Output characteristic (min.) Specifications valid for 230V AC input voltage, +25°C ambient temperature, and 5 min run-in time, unless otherwise stated. They are subject to change without prior notice. 0 4 8 12 16 20 24 28 32 0 5 10 15 20 25Output voltage Vout [VOutput current Iout [A] Tamb = 60°C / 45°C / 25°C / 0°C 84 85 86 87 88 89 90 91 92 93 94 95 3 5 7 9 11 13 230 V ACin / 28 V DCout 230 V ACin / 24 V DCout Output current Iout [A]Efficiency [%]Vout range 0 10 20 30 40 50 60 70 80 90 100 210 230 250 270 290 310 330 350 370 390 Input voltage VDCin [V]Hold-up time [ms]Partial load DCin Nominal load Power Boost 0 10 20 30 40 50 60 80 100 120 140 160 180 200 220 240 Input voltage VACin [V]Hold-up time [ms]Power Boost Switch pos. 115V ACinSwitch pos. 230V Nominal load Nom. load Partial load Power Boost Partial load with Partial Load = 120W Nominal Load = 240W Power Boost = 288W